• Title/Summary/Keyword: Tc-99m-MIBI

Search Result 160, Processing Time 0.035 seconds

Comparison of Ultrasound with $^{99m}-Tc-MIBI$ Scintimammography in the Detection of Breast Cancer (유방암의 진단에서 유방초음파 검사와 $^{99m}-Tc-MIBI$ 유방스캔의 비교)

  • Seok, Ju-Won;Kim, Seong-Jang;Kwak, Hi-Suk;Lee, Jun-Woo;Kim, In-Ju;Kim, Yong-Ki;Bae, Young-Tae;Kim, Dong-Soo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.36 no.3
    • /
    • pp.177-184
    • /
    • 2002
  • Purpose: Ultrasonography and $^{99m}-Tc-MIBI$ scintimammography were validated as useful diagnostic tools for primary breast cancer. However, ultrasound has the problem of low specificity. We compared the diagnostic usefulness of ultrasound with $^{99m}-Tc-MIBI$ scintimammography in the diagnosis of breast cancer. Materials and Methods: This study included 174 patients who had ultrasound and $^{99m}-Tc-MIBI$ scintimammography peformed on breast masses from 1999 to 2000. The pathologic results were obtained by surgery or FNAB. Results: Among the 174 patients, malignant breast disease numbered 117 and benign breast disease numbered 57. Ultrasound revealed 88 TP, 9 FN, 8 FP, 34 TN, and 35 indeterminate cases. $^{99m}-Tc-MIBI$ scintimammography revealed 91 TP, 25 FN, 9 FP, and 48 TN. The sensitivity, specificity, positive predictive value, and negative predictive value of Ultrasound were 66.7%, 44.2%, 67.2%, and 43.6% respectively. The sensitivity, specificity, positive predictive value, and negative predictive value of $^{99m}-Tc-MIBI$ scintimammography were 77.8%, 84.2%, 91%, and 64.9% respectively. Among the 35 indeterminate ultrasound cases, $^{99m}-Tc-MIBI$ scintimammography revealed 13 TP, 15 TN, and 7 FP Conclusion: $^{99m}-Tc-MIBI$ Scintimammography was more sensitive and specific than ultrasound for the detection of primary breast cancer and provided more useful information in cases of indeterminate ultrasound findings.

Usefulness and Comparison of $^{201}TI$-chloride, $^{99}mTc$-MIBI, $^{99}mTc(V)$-DMSA Single Photon Emission Computed Tomography in Distinguishing Lung Cancer from Benign Lesion (폐암과 양성질환의 감별에 $^{201}TI$-chloride, $^{99}mTc$-MIBI, $^{99}mTc(V)$-DMSA 단일광자전산화단층촬영술의 비교 및 가치)

  • Kim, Chang Ho;Chae, Sang Cheol;Park, Jae Yong;Jung, Tae Hoon;Ahn, Byeong Cheol;Lee, Jae Tae
    • Tuberculosis and Respiratory Diseases
    • /
    • v.43 no.5
    • /
    • pp.720-727
    • /
    • 1996
  • Objectives: $^{201}TI$ - chloride, $^{99m}Tc$ - MIBI, $^{99m}Tc$(V) - DMSA SPECT has been used in distinguishing lung cancer from benign lesion. To compare the diagnostic efficacy of SPECT with these tumor - seeking agents, we perfonned three consecutive SPECT using $^{201}TI$, $^{99m}Tc$ - MIBI, $^{99m}Tc$(V) - DMSA in same subjects with a solitary pulmonary lesion. Methods: SPECT was carried out at 10min and 3hr for $^{201}TI$ after injection of 20mCi, and 2hr for $^{99m}Tc$ - MIBI and $^{99m}Tc$(V) - DMSA after injection of 20mCi, respectively, in 37 patients with a solitary pulmonary lesion(27 lung cancer and 10 benign diseases). In patients showing visual uptake on lesion site, we obtained the lesion - to - background(target lesion/contralateral normal lung) uptake ratio from transverse slice for each radionuclide and also calculated the retention index for $^{201}TI$. Results: The diagnostic sensitivity of $^{201}TI$, $^{99m}Tc$ - MIBI and $^{99m}Tc$(V) - DMSA SPECT to lung cancer was 100%, 96% and 73%, and the specificity was 40%, 70% and 70%, respectively. The low specificities for these agents were mainly due to high positive uptake in patients with active pulmonary tuberculosis. There were no significant differences in uptake ratios and retention index between malignant and benign lesions, and among the histologic types of lung cancer. Conclusion : $^{201}TI$ and $^{99m}Tc$ - MIBI showed higher sensitivity than $^{99m}Tc$(V) - DMSA for detecting lung cancer, but was of limited usefulness in distinguishing lung cancer from benign lesion due to low specificity, especially in area with a high prevalence of active pulmonary tuberculosis.

  • PDF

Thallium-201 Scan in Bone and Softtissue Sarcoma - Comparison with Tc-99m-MIBI and Tc-99m-MDP Scan - (악성 골 및 연부조직 종양에서 Tl-201 SCAN의 진단적 효능 - Tc-99m-MIBI 및 Tc-99m-MDP scan과의 비교 -)

  • Shin, Duk-Seop;Cho, Ihn-Ho;Ahn, Jong-Chul;Ahn, Myun-Hwan;Lee, Sang-Ho
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.2 no.1
    • /
    • pp.1-7
    • /
    • 1996
  • PURPOSE : The purpose of this study is to know the ability of detecting malignant tumor tissue by Tl-201 scan, and to compare with that of Tc-99m-MIBI and Tc-99m-MDP scan. MATERIAL AND METHODS : Between February 1994 and December 1995,38 unselected patients with various bone pathologies were studied prospectively. Eighteen had malignant bone and soft tissue pathologies, while twenty had benign. All patients were studied with Tl-201, Tc-99mMIBI and Tc-99m-MDP scan prior to surgical biopsy. PICKER Prism 2000 gamma camera with high resolution parallel hole collimator was used for scanning. To avoid the interaction of isotope, the early(30min.) and delayed phase(3hrs.) of Tl-20l scan was performed first and Tc-99m-MIBI scan was performed after 30 minutes, and then Tc-99m-MDP scan 48 hours later. The scan images were visually evaluated by a blinded nuclear medicine physician. We could find true positive, true negative, false positive and false negative by the comparison of results with those of biopsy. We calculated positive and negative predictive value(%), sensitivity(%), specificity(%) and diagnostic accuracy(%) of each scan. RESULT : The results of each scan were 85.7, 100, 100, 85, 92.1% in Tl-201, 81, 94.1, 94.4, 80, 86.8% in Tc-99m-MIBI and 50, 66.7, 88.9, 20, 52.6% in Tc-99m-MDP scan. As a conclusion, Tl-201 scan was the most specific and accurate method for detecting malignant tumor tissue. Tc-99m-MIBI scan was also good for malignant tumor searching. CONCLUSION : With our results, we can use Tl-201 scan to differentiate benign from malignant tumor, and to evaluate the response of preoperative chemotherapy or radiotherapy, and to determine the residual tumor or local recurrence. For the better result, we need to have a more detail information about false positive cases and a more objective and quantitative reading technique.

  • PDF

Comparison of $^{99m}Tc-MIBI$ Myocardial Uptake at Rest with Reinjection and 24-hour after Reinjection Images of $^{201}Tl$ ($^{201}Tl$$^{99m}Tc-MIBI$에 의한 생존심근의 진단 비교 -재분포영상에 고정관류결손을 보인 환자에서 $^{201}Tl$ 재주사법 및 $^{99m}Tc-MIBI$ 휴식기스캔에 의한 심근섭취 비교-)

  • Bom, Hee-Seung;Kim, Ji-Yeul;Park, Joo-Hyung;Ahn, Young-Keun;Jeong, Myung-Ho;Cho, Jeong-Gwan;Park, Jong-Choon;Kang, Jung-Chaee
    • The Korean Journal of Nuclear Medicine
    • /
    • v.26 no.2
    • /
    • pp.274-279
    • /
    • 1992
  • Clinical role of $^{99m}Tc-MIBI$ myocardial scintigraphy in the diagnosis of coronary artery disease (CAD) is now well accepted, however, the role of it in the identification of viable myocardium in patients with chronic CAD has not yet been clarified. To determine the usefulness of rest-injected $^{99m}Tc-MIBI$ scan as a marker of myocardial viability, the regional uptake of this agent at rest was compared with that of $^{201}Tl$ on reinjection and 24 hours after reinjection images. Subject patients were 13 chronic CAD patients who showed irreversible perfusion defect(s) on standard pharmacologic (dipyridamole) stress-redistribution images. Immediately after the redistribution images were obtained, 37 MBq thallium was injected at rest, and images were reacquired at 10 minutes and 24 hours after reinjection. After then 740 MBq $^{99m}Tc-MIBI$ was injected, and 1 hour later rest MIBI myocardial imaging was performed. Five sets of imagestress, redistribution, reinjection, delayed images of thallium, and rest image of MIBI) were then analyzed qualitatively and quantitatively. Left ventricle was arbitrarily divided into 9 segments (apex, basal and apical portions of anterior, septal, inferior, and lateral walls). Seven patients and 30 regions showed a fixed perfusion defect on the stress-redistribution images. Among 30 regions, 15 showed positive uptakes and 6 showed negative uptakes on both $^{201}Tl$ reinjection/delayed images and $^{99m}Tc-MIBI$ rest images. Five regions showed only thallium uptake and were regarded as viable clinically. Of four regions which showed only $^{99m}Tc-MIBI$ uptake, two were regarded as viable, while the other two were regarded as a nonviable scar tissue clinically. In conclusion, $^{201}Tl$ reinjection technique was more reliable in the identification of viable myocardium. However, the role of $^{99m}Tc-MIBI$ in identification of viable myocardium was still remained to be clarified because 2 of 9 regions showed only $^{99m}Tc-MIBI$ uptake and were regarded as viable tissues.

  • PDF

Unexpected Uptake of Tc-99m MIBI in Thymic Carcinoma: Ring-like Appearance (흉선암종에서 우연히 발견된 환 모양의 Tc-99m MIBI 섭취 증가)

  • Sohn, Myung-Hee;Jeong, Hwan-Jeong;Lim, Seok-Tae;Kim, Dong-Wook;Yim, Chang-Yeol
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.41 no.3
    • /
    • pp.255-257
    • /
    • 2007
  • A 59-year-old man with thymic carcinoma underwent Tc-99m MIBI myocardial SPECT, and Tc-99m MIBI uptake in the mass was unexpectedly found in a planar image. SPECT images of the thorax showed an increased uptake area with central photon deficiency (a ring-like appearance), which reflected central tumor irreversible ischemia or progressing necrosis with peripheral viable tumor tissue.

Tc-99m MIBI and Tl-201 Uptake in a Thymic Carcinoma (악성 흉선종에서 관찰된 Tc-99m MIBI와 Tl-201의 섭취)

  • Hyun, In-Young
    • The Korean Journal of Nuclear Medicine
    • /
    • v.37 no.4
    • /
    • pp.260-261
    • /
    • 2003
  • Tc-99m methoxyisobutylisonitrile (MIBI) and Tl-201/technetium subtraction scintigraphy have been used for localization of abnormal parathyroid gland. The uptake mechanism of tracers has been postulated to be increased cellular density and vascularity, or dependent on the presence of mitochondria-rich cells. However, the uptake of these tracers was not specific for abnormal parathyroid gland. The author report a case of thymic carcinoma that would have been mistaken for carcinoma of parathyroid because of Tc-99m MIBI and Tl-201 uptake.

Diffuse Bone Marrow Uptake of $^{99m}$Tc-MIBI in A Case of Intravascular Large B-cell Lymphoma (혈관내 B 대세포 림프종 환자에서 발견된 $^{99m}$Tc-MIBI의 미만성 골수 섭취)

  • Moon, Seung-Hwan;Oh, So-Won;Paeng, Jin-Chul;Paik, Jin-Ho;Lee, Dong-Soo
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.43 no.4
    • /
    • pp.352-356
    • /
    • 2009
  • Intravascular large B-cell lymphoma (IVLBCL) is a subtype of diffuse large cell lymphoma, characterized by proliferation of lymphoid cells in the intravascular space of various organs without causing a mass effect. Although $^{18}$F-FDG PET is a powerful imaging tool in lymphoma, the usefulness of $^{18}$F-FDG PET in the assessment of IVLBCL is still controversial. $^{99m}$Tc-MIBI, a tumor imaging radiopharmaceutical with a different mechanism from that of $^{18}$F-FDG, has been reported to be also effective in lymphoma. However, there is nearly no report on the efficacy of $^{99m}$Tc-MIBI in the assessment of IVLBCL. We present one case of IVLBCL that showed $^{99m}$Tc-MIBI accumulation in the involved bone marrow as an incidental finding, which was discrepant from that of $^{18}$F-FDG PET.

Adenosine $^{99m}Tc-MIBI$ Scintigraphy in the Diagnosis of Coronary Artery Disease: Comparison with Exercise $^{99m}Tc-MIBI$ Scintigraphy (관상동맥 질환에서의 Adenosine 부하 $^{99m}Tc-MIBI$ 심근 스캔의 진단적 가치 : 운동 부하 $^{99m}Tc-MIBI$ 심근 스캔과의 비교)

  • Kang, Seung-Wan;Woo, Eon-Jo;Chae, Sung-Chull;Jun, Jae-Eun;Park, Wee-Hyun;Chung, Byung-Cheon;Choi, Chung-Il;Lee, Jae-Tae;Lee, Kyu-Bo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.26 no.1
    • /
    • pp.72-81
    • /
    • 1992
  • Pharmacologic coronary vasodilation in conjunction with myocardial scintigraphy has become an accepted alternative to dynamic exercise testing for the diagnosis of coronary artery disease. Although dipyridamole has traditionally been used for this purpose, it causes frequent side effect, which at times can be life-threatening. Moreover, dipyridamole dose not elicit maximal coronary vasodilation in a substantial number of patients receiving the usual i.v. dose. Adenosine is an endogenously produced compound that has significant effects as a coronary vasodilator and rapid onset action and extremely short half-life (< 10 seconds). The diagnostic accuracy and safety profile of adenosine $^{99m}Tc-MIBI$ myocardial scintigraphy were evaluated and comparison with exercise $^{99m}Tc-MIBI$ was performed. Twenty-eight subjects underwent $^{99m}Tc-MIBI$ imaging after adenosine infusion and exercise $^{99m}Tc-MIBI$ imaging. Adenosine was infused intravenously at a dose of 0.14mg/kg/body weight per minute for 6 min and MIBI was injected at 3 minute. Adenosine caused an incerease in heart rate ($64{\pm}12$ at baseline versus $74{\pm}16$ beats/min at peak effect, p<0.001), a mild decrease in systolic and diastolic blood pressure and a slightly increase in PR interval(p; NS). Side effects were reported in 92% of patients and were mostly mild in nature and promptly resolved within 1 or 2 minutes of termination of adenosine infusion. Facial flushing (53%), chest pain (36%), mild dyspnea (39%), headache (21%), throat discomfort (21%) were frequent symptoms. ST segment depression (> 1 mm) and second degree AV block in electrocardiography occured in 11% of the patients, respectively. The overall sensitivity and specificity for individual coronary stenoses in 16 patients underwent coronary angiography were 88% and 95%, respectively. The agreement ratio of segmental perfusion between adenosine and exercise images was 92% (Kappa index=0.82). In conclusion, $^{99m}Tc-MIBI$ myocardial perfusion scintigraphy with intravenous adenosine is a feasible, safe and highly accurate noninvasive technique for the detection of coronary artery disease and results are at least comparable with those of exercise $^{99m}Tc-MIBI$ scintigraphy.

  • PDF

Normal Limits of Left Ventricular Volumes and Ejection Fraction Measured by Gated Myocardial Perfusion SPECT: Comparison of Tc-99m MIBI and Tl-201 (심근 게이트 SPECT로 측정한 좌심실 용적과 구혈률의 정상 값 확립: Tl-201과 Tc-99m MIBI 게이트 SPECT의 비교)

  • Hyun, In-Young;Seo, Jeong-Kee;Kwan, Jun;Park, Keum-Soo;Choe, Won-Sick;Lee, Woo-Hyung
    • The Korean Journal of Nuclear Medicine
    • /
    • v.37 no.3
    • /
    • pp.147-152
    • /
    • 2003
  • Purpose: We evaluated radioisotope and sex-specific differences of normal limits for left ventricle volumes (LWs) and ejection fraction (EF) using myocardial perfusion gated SPECT (g-SPECT). Materials and Methods: Rest Tl-201/post-stress Tc-99m MIBI g-SPECT measurements with acquisitions of 8-frame were evaluated for 70 patients (mean age $55{\pm}14.56%$ female) who either had < 10% pretest likelihood of CAD (n = 12) or had normal coronary angiography (EF > 50%) (n = 58). LVEF, LWs were automatically determined by quantitative gated SPECT using QGS program. Results: Similar results were obtained for mean LVEF between Tc-99m MIBI ($62%{\pm}7%$ and Tl-201 ($63%{\pm}8%$) g-SPECT measurements. In Contrast, Tl-201 g-SPECT had significantly lower LWs values ($EDV;\;74{\pm}23mL,\;ESV;\;28{\pm}14mL$) than Tc-99m MIBI g-SPECT ($EDV;\;82{\pm}25mL,\;ESV;\;32{\pm}15mL$) (p<0.05). Women had significantly lower EDV ($Tc-99m\;MIBI;\;71{\pm}18mL,\;Tl-201;\;65{\pm}17mL$), and ESV values ($Tc-99m\;MIBI;\;27{\pm}10mL,\;Tl-201;\;23{\pm}8mL$) compared with EDV ($Tc-99m\;MIBI;\;96{\pm}27mL,\;Tl-201;\;85{\pm}24mL$), and ESV Values ($Tc-99m\;MIBI;\;40{\pm}17mL,\;Tl-201;\;36{\pm}16mL$) of men (p<0.05). Women had significantly higher LV EF Values ($65%{\pm}7%$) than men ($60%{\pm}8%$) by Tl-201 gated SPECT (p<0.05). Conclusion: These data suggest significant differeuces in normal limits for LWs and EF, according to genders and radiopharmaceutical. Therefore, the evaluation of cardiac function in patients should consider radioisotope and sex-matched normal values.

Assessment of Regional Myocardial Wall Motion by Gated $^{99m}Tc-MIBI$ Myocardial SPECT (게이트 $^{99m}Tc-MIBI$ 심근 SPECT의 심근 분절 운동 평가능력)

  • Kim, S.W.;Lee, D.S.;Kim, S.H.;Hyun, I.Y.;Chung, J.K.;Lee, M.M.;Lee, M.C.;Koh, C.S.
    • The Korean Journal of Nuclear Medicine
    • /
    • v.29 no.4
    • /
    • pp.473-477
    • /
    • 1995
  • Information about regional wall motion obtained with gated $^{99m}Tc-MIBI$ SPECT was compared in 23 subjects(4 normals) to echocardiography or contrast left ventriculography. Gated SPECT study using 20-30 mCi $^{99m}Tc-MIBI$ were aquired lot 8 frames/RR interval (aqusition time=40min.) and processed with Cine Mode computer protocol. Regional wall motion was assessed by visual analysis. The concordance with echocardiography was 88% and with contrast ventriculography was 78%. We conclude that gated $^{99m}Tc-MIBI$ SPECT was effective in assessing the regional wall motion with the information of regional perfusion in one study.

  • PDF