• 제목/요약/키워드: Tc-99m pertechnetate

검색결과 66건 처리시간 0.033초

Tc-99m MAG3 신장 스캔시 뇨 누출과 유사한 유리 Tc-99m 과산화테크네슘에 의한 장관내 방사능 (Bowel Activity Caused by Free Tc-99m Pertechnetate Mimicking Urine Leaks during Tc-99m $MAG_{3}$ Renal Scintigraphy)

  • 임석태;김민우;손명희
    • 대한핵의학회지
    • /
    • 제37권2호
    • /
    • pp.135-136
    • /
    • 2003
  • A 43-year-old woman with diabetic nephropathy underwent a Tc-99m MAG3 renal scintigraphy for the evaluation of renal function. Posterior images at 60 minutes demonstrated a migration of radiotracer activity beyond the lower pole of the left kidney, which might be incorrectly interpreted as urine leaks. However, the increased activities were moving along the bowel lumens over time. Another ring-like radioactivity was also seen in the suprasplenic region, and increased with time. These radioactivities were in the gastric fundus and gastrointestinal tract and caused by free Tc-99m pertechnetate.

갑상선환자에서의 5분 $^{99m}Tc-Pertechnetate$ 섭취율과 방사성옥소섭취율의 상관관계 (Correlation between 5-Minute $^{99m}Tc-Pertechnetate$ Uptake and 24-Hour $^{131}I$ Uptake in Patients with Thyroid Disease)

  • 이찬우;원규장;윤현대;조인호;김태년;신동구;이형우;심봉섭;이현우
    • 대한핵의학회지
    • /
    • 제26권2호
    • /
    • pp.280-289
    • /
    • 1992
  • The 20-minute $^{99m}Tc-pertechnetate$ uptake became readily available for routine use and it replaced $^{131}I$ for thyroid imaging. However measuring thyroid uptake during a 5-minute minimizes pertechnetate uptake by the salivary glands and presence of contaminated saliva from those glands in to the pharynx and esophagus. A study was carried out to determine the suitability of the utility of a S-minute and 20-minute interval from administration of $^{99m}Tc-pertechnetate$ to imaging and uptake measurement as a replacement for the 24 hour standard originally established with $^{131}I$, and to evaluate the relationship between 5-minute $^{99m}Tc-pertechnetate$ uptake and other thyroid functions. A 5-minute and 20-minute uptake of $^{99m}Tc-pertechnetate$ were measured in 70 patients with thyroid disease at Yeungnam University Hospital from March 1, 1991 to Feb. 29, 1992. The results were as follows. 1) The 5-minute $^{99m}Tc-pertechnetate$ uptake in Graves' disease, Hashimoto's thyroiditis, simple goiter, non toxic nodular goiter, subacute thyroiditis and euthyroid were 18.2%, 14.6%, 2.8%, 3.2%, 1.2% and 1.1%, respectively. There was a significant difference between the mean of the euthyroid group and the mean of the Graves' disease. So differenciation between them can be easily made. 2) The 5 minute $^{99m}Tc-pertechnetate$ thyroid uptake was well correlated with 24 hour $^{131}I$ thyroid uptake (r=0.75, p<0.001). These data provided an equation for estimating the 24 hour uptake of iodide given the 5 minute pertechnetate uptake: Estimated 24-hour $^{131}I$ thyroid Uptake= 7.188*ln (5 minute $^{99m}Tc-pertechnetate$ uptake)+16.94 3) The 20-minute $^{99m}Tc-pertechnetate$ thyroid uptake was well correlated with 24-hour $^{131}I$ uptake (r=0.72, p<0.001) and 5-minute $^{99m}Tc-pertechnetate$ thyroid uptake (r=0.96, p<0.001). 4) In the Graves' disease, The 5-minute $^{99m}Tc-pertechnetate$ thyroid uptake was well correlated with serum $T_3-resin$ uptake (r=0.46, p<0.01), serum total $T_3$ (r=0.55, p<0.05), serum total $T_4$ (r=0.46, p<0.05). These results suggest that 5-minute ${99m}Tc-pertechnetate$ thyroid uptake has been found at least as useful as 24-hour $^{131}I$ uptake for diagnostic confirmation at our hospital, the logistical advantages of completing the diagnosis. The exam in 5-minutes led us to abandon the 24-hour study in the majority of patients, but the 24-hour $^{131}I$ uptake is still obtained in patients with planned or potential radioiodine therapy.

  • PDF

$^{99m}Tc$-HMPAO 표지효율에 대한 고찰 (Study on Labeling Efficiency of $^{99m}Tc$-HMPAO)

  • 현준호;임현진;김하균;조성욱;김진의
    • 핵의학기술
    • /
    • 제16권2호
    • /
    • pp.131-134
    • /
    • 2012
  • 핵의학검사에서 방사성의약품의 표지효율은 검사의 정확성과 신뢰성 측면에서 중요하다. 보통 Brain SPECT검사에 사용되는 $^{99m}Tc$-HMPAO는 화학적으로 불안정하고 불순물의 발생이 많아 표지효율의 저하가 나타나기 쉽다. 이에 본 연구는 $^{99m}Tc$-HMPAO의 표지효율에 영향을 미치는 인자에 대한 실험을 통해 $^{99m}Tc$-HMPAO 표지 및 사용에 도움이 되고자 한다. Brain SPECT에 사용되는 국산 동아제약의 HMPAO vial을 대상으로 실험하였다. 삼영사의 generator 55.5 GBq (1,500 mCi)를 이용하였고, TLC 측정세트(ITLC-SG, butanone, saline, TLC chamber)와 Radio-TLC 스캐너(Bioscan, AR-2000)를 이용하였다. 첫 번째 실험은 generator에서 1, 8, 16, 24, 28시간 간격을 두고 용출한 $^{99m}Tc$-pertechnetate를 각각 HMPAO와 표지하여 표지효율을 측정하였다. 두 번째 실험은 generator에서 용출한 $^{99m}Tc$-pertechnetate를 0, 1, 3, 6시간경과에 따라 1.85GBq (50mCi)/1 ml를 취하여 HMPAO와 표지하여 표지효율을 측정하였다. 세 번째는 $^{99m}Tc$-HMPAO를 표지 후 0, 30분, 3시간, 5시간, 7시간이 경과했을 때 표지효율을 측정하였다. 첫 번째 실험에서 표지효율은 시간 순으로 95.05%, 94.64%, 94.94%, 95.64%, 96.76%로 나타났다. 두 번째 실험에서는 94.38%, 94.23%, 93.26%, 91.03%로 나타났다. 세 번째 실험에서는 95.76%, 94.17%, 88.19%, 83.6%, 76.86%로 나타났다. 첫 번째 실험에서 generator에서 24시간 후에용출한 $^{99m}Tc$-pertechnetate를 사용 한 표지효율은 비교적 높게 측정되었다. 추가실험을 통하여 임상에서의 사용 가능성에 대한 논의가 필요할 것으로 사료된다. 두 번째 실험에서 시간이 지날수록 표지효율은 다소 감소하였으나 6시간 이후에도 91% 이상으로 높게 측정되었다. 보충실험을 통하여 보완이 필요할 것으로 판단된다. 세 번째 실험에서 시간이 흐를수록 표지효율은 급격하게 감소하였다. 특히, 정확한 검사를 위해 표지후 3시간 이내에 사용하는 것이 좋다고 판단된다.

  • PDF

$^{99m}TC$-Pertechnetate에 의한 출혈성 Meckel 게실의 진단 2예 (Diagnosis of a Bleeding Meckel's Diverticulum Using $^{99m}$Technetium Pertechnetate Scanning - A case report -)

  • 허영수;김재황;권굉보
    • Journal of Yeungnam Medical Science
    • /
    • 제4권1호
    • /
    • pp.129-132
    • /
    • 1987
  • 본 영남대학교 외과학교실 Meckel게실로 인한 출혈을 주소로 입원할 두 경의 환자에서 수술전 $^{99m}TC$-perechnetate의 이용에 의한 성공적 진단을 하고 수술로써 이를 확인 치험하였기에 이에 대한 증례보고와 함께 문헌고찰을 하였다.

  • PDF

Thyroid imaging in 53 cats with hyperthyroidism using technetium-99m as pertechnetate

  • Lee, Young-won
    • 대한수의학회지
    • /
    • 제39권2호
    • /
    • pp.394-397
    • /
    • 1999
  • Thyroid imaging was performed in 53 hyperthyroid cats with technetium-99m as pertechnetate($^{99m}TcO_{4}$). Increased radionuclide accumulation was found in all cats. Thirty-four cats had bilateral enlargements of the thyroid glands and 14 cats had unilateral enlargements. Five cats had multi-focal accumulation of $^{99m}TcO_{4}$ in the ventral neck or mediastinum. Conclusively, nuclear thyroid image is useful method in diagnosis of feline hyperthyroidism.

  • PDF

설하갑상선과 수유중 유방이 Tc-99m Pertechnetate 스캔에 동시에 관찰된 증례 (Simultaneous Visualization of the Sublingual Thyroid and Lactating Breasts with Tc-99m Pertechnetate Scintigraphy)

  • 서지형;성영옥;배진호;정신영;안병철;이재태;이규보
    • 대한핵의학회지
    • /
    • 제39권6호
    • /
    • pp.489-490
    • /
    • 2005
  • Purpose: The thyroglossal duct runs from the base of the tongue to the thyroid. Rarely the thyroid completely fails to migrate and results in ectopic thyroid tissue, which can be demonstrated scintigraphically. A 31-year old female patient was referred for thyroid scintigraphy due to protruding mass at the base of the tongue. She was mildly hypothyroid. Te-99m pertechnetate thyroid scan was performed to rule out ectopic thyroid gland. There showed a focal area of intense tracer uptake in sublingual area, suggesting the sublingual thyroid. In addition there noted diffusely increased tracer uptake in both breasts. The patient delivered a baby 6 months prior to the scan and was on breast-feeding. Free Tc-99m pertechnetate physiologically secrets into the salivary glands, the stomach, the gastrointestinal tract, the genitourinary tract and the mammary glands and sodium-iodide symporter plays a role in the accumulation of free Tc-99m pertechnetate. We report simultaneous visualization of lactating breasts and ectopic thyroid gland in the base of the tongue.

$Al^{3+}$ 존재가 $^{99m}Tc$-MDP의 표지효율과 생체내 분포에 미치는 영향 (Effect of $Al^{3+}$ on Labeling Efficiency and Biodistribution of $^{99m}Tc$-MDP)

  • 장영수;정재민;김영주;곽철은;이동수;정준기;이명철;고창순
    • 대한핵의학회지
    • /
    • 제30권3호
    • /
    • pp.361-366
    • /
    • 1996
  • 본 연구는 $^{99}Mo-^{99m}Tc$ 발생기시스템에서 용출될 수 있는 알루미늄이 $^{99m}Tc$-MDP의 표지효율과 생체내 분포에 어떤 영향을 미치는지를 보기 위한 실험이다. 알루미늄이온 농도 ($0-62.5{\mu}g/ml$)를 증가시킬수록 $^{99m}Tc$-MDP의 표지효율은 급격히 떨어지며 상대적으로 $^{99m}Tc$ pertechnetate와 hydrolyzed reduced $^{99m}Tc$ 부위의 상대적인 양은 증가되었다. $^{99m}Tc$-MDP는 알루미늄 존재하에서도 상당히 안정하였다. 알루미늄에 의해 $^{99m}Tc$-MDP 반응물이 교질을 형성하는지를 보기 위해 $0.22{\mu}m$ syringe filter로 여과한 액은 여과하지 않은 것과 유의한 차이를 나타내지 않았다. 마우스에 대한 생체내 분포실험은 알루미늄에 의해 $^{99m}Tc$-MDP의 표지효율이 떨어지고 $^{99m}Tc$ pertechnetate의 증가로 인해 혈액과 심장의 흡수는 증가하나 간과 뼈의 흡수는 별다른 차이를 나타내지 않았다. 랫트의 골스캔에서는 $5{\mu}g/ml$의 알루미늄농도에서는 영상의 차이가 없으나 $10{\mu}g/ml$ 농도에서는 하복부의 흡수가 높게 나타났다. 이상의 결과는 알루미늄이 $^{99}Mo-^{99m}Tc$ 발생기시스템 칼럼의 용출제한량인 $10{\mu}g/ml$이하에서도 MDP의 표지효율에 상당한 영향을 미칠 수 있다는 것을 보여준다. 따라서$^{99m}Tc$-MDP 골스캔시 연조직에의 흡수가 보이는 경우에도 방사성의약품의 방사화학적 순도에 대한 정도관리가 충분히 이루어 졌다면 $^{99}Mo-^{99m}Tc$ 발생기시스템에서 용출되는 알루미늄에 의한 영향은 배제될 수 있다.

  • PDF

방사선 치료에 따른 $^{99m}Tc$-pertechnetate를 이용한 이하선과 악하선 기능 검사의 유용성 (Usefulness of the Salivary Gland Scan Using $^{99m}Tc$-pertechnetate after Radiotherapy in Patients with Head and Neck Cancer)

  • 김종진;홍인수;이종영;김명순;성기준;박진숙
    • 대한핵의학회지
    • /
    • 제30권3호
    • /
    • pp.325-331
    • /
    • 1996
  • $^{99m}Tc$-pertechnetate를 이용하여 두경부암 환자에서 이하선과 악하선의 방사선 조사 전후 및 추적 검사에서 방사선 조사로 인한 타액선의 기능 변화, 기능저하의 회복 여부, 이하선과 악하선의 방사선에 대한 감수성 차이, 그리고 구강건조증이 있던 환자와 없던 환자 사이의 기능 저하 차이를 객관적으로 평가하고자 하였다. 방사선 치료를 받는 두경부암 환자중 방사성 동위원소를 이용하여 이하선과 악하선 기능 검사를 시행한 19명의 환자를 대상으로 하였다. $^{99m}Tc$-pertechnetate를 이용한 이하선과 악하선 기능 검사는 측정된 방사능치에 의한 섭취 곡선과 구연산으로 자극하였을 때의 평균 배출율에 의한 배출 곡선을 포함하였다. 이하선과 악하선의 섭취 곡선에서는 방사선 치료전보다 치료 1주후에서 증가하였고 치료 2주후와 3주후 그리고 치료 종료시에서는 치료 전과 비슷하거나 약간 증가하였으며 방사선 치료 후에서는 시간이 지날수록 점점 감소하였다. 이하선과 악하선의 배출 곡선에서는 방사선 치료 시작부터 종료시까지는 급격히 감소하였고 방사선 치료 후 1년까지의 검사에서는 배출율이 회복되지 않았다. 이하선과 악하선의 방사선에 대한 감수성 차이는 나타나지 않았고 구강건조증을 호소하는 환자와 호소하지 않는 환자 사이의 이하선과 악하선의 평균 배출율 차이는 발견되지 않았다. $^{99m}Tc$-pertechnetate를 이용한 이하선과 악하선기능 검사로 방사선 치료에 따른 이하선과 악하선의 기능 변화를 객관적으로 평가할 수 있고, 방사선 치료후 1년까지는 이하선과 악하선의 기능 회복이 없어 방사선 치료를 받은 두경부암 환자의 타액선 기능에 관한 예후추정에 도움이 되리라 사료된다.

  • PDF

Dose calibrator 측정 깊이와 용량의 변화에 따른 선량 값의 성향에 대한 고찰 (A Study on the Tendency of Dose value According to Dose calibrator Measurement Depth and Volume)

  • 김진구;함준철;오신현;강천구;김재삼
    • 핵의학기술
    • /
    • 제24권1호
    • /
    • pp.20-26
    • /
    • 2020
  • 핵의학이란 방사성동위원소 추적자를 인체에 투여하여 관심장기에 대한 형태학적인 정보와 생물학적이고 기능적인 정보를 얻고 평가한다. Dose calibrator는 의료기관에서 단일 핵종의 방사능을 측정하기 위해 사용하는 장비이며, 방사성동위원소의 정확한 용량의 투여는 진단과 치료에 중요한 요인이다. 최근 정량분석을 위한 여러 시스템이 개발되고 있고 ERPF (Effective Renal Plasma Flow), GFR (Glomerular Filtration Rate) 등 정량분석이 필요한 검사에 있어서 정확한 투여 용량 및 재현성 있는 측정이 중요해지고 있다. 따라서 본 논문을 통해 Dose calibrator의 측정 깊이와 용량에 따른 선량 값의 성향을 알아보고 적절한 측정 깊이 및 용량에 대해 알아 보고자 한다. 실험에 사용한 Dose calibrator는 CRC-15R과 CRC-15βeta (Capintec, New Jersey, USA)를 사용하였다. 선원으로는 표준선원(Standard source) 137Cs, 133Ba, 57Co를 사용하였고, 방사성 의약품은 99mTc-pertechnetate를 사용하였다. 표준선원은 측정 깊이만 변화하여 0 cm부터 15 cm까지 1 cm 깊이마다 15회씩 측정했고, 99mTc-pertechnetate의 경우에는 1 mL 주사기로 표준선원과 동일한 깊이로 실험을 진행했고, 용량의 변화를 고려하여 0.1 mL, 0.3 mL, 0.5 mL, 0.7 mL, 0.9 mL로 각 깊이마다 15회씩 측정했다. 표준선원인 137Cs, 133Ba, 57Co의 깊이의 변화에서는 모두 깊이에 따른 선량 값의 변화가 통계적으로 유의한 차이가 있었다(p<0.05). 99mTc-pertechnetate도 깊이에 따른 용량의 변화에서 선량 값이 모두 통계적으로 유의한 차이가 있었다(p<0.05). CRC-15R의 표준선원 비교 그래프에서 137Cs, 133Ba, 57Co는 Plateau를 그리기 시작한 2 cm에서 9 cm까지는 각 선원마다 비교시 통계적으로 유의한 차이가 없었다(p>0.05). CRC-15βeta의 표준선원 비교 그래프에서는 Plateau를 그리기 시작한 영역은 3 cm에서 9 cm로 통계적으로 유의한 차이가 없었다(p>0.05). 99mTc-pertechnetate의 그래프는 0.1 mL에서 1 cm에서 7 cm, 0.3 mL와 0.5 mL에서는 0 cm에서 7 cm, 0.7 mL에서는 0 cm에서 6 cm, 0.9 mL에서는 0 cm에서 5 cm에서 통계적으로 유의한 차이가 나타나지 않았다(p>0.05). 본 연구를 통해 방사성동위원소를 환자에게 주입하거나 정도관리를 진행 시 편차가 적고 재현성을 위해 신뢰할 수 있는 구간을 확인 할 수 있었다. 높이에 따른 변화가 가장 적은 Plateau의 구간이 0.3 mL 혹은 0.5 mL의 용량으로 0 cm 에서 7 cm의 깊이에서 측정한다면, 편차를 최소한으로 줄일 수 있을 것으로 사료된다. 표준선원의 경우에는 본 연구의 결과에 따라 장비마다 Plateau의 변화가 가장 적은 구간의 깊이에서 재현성 있게 측정하는 것이 중요하다고 생각된다. 적절한 구간을 찾아서 재현성 있는 검사를 시행하면 검사의 품질향상 및 피폭선량저감 그리고 진단능을 높이는데 이바지 할 것이라고 생각된다.