• Title/Summary/Keyword: Target pollutant

Search Result 121, Processing Time 0.024 seconds

The Management Methods of Multi-Purpose Ecological Reservoir by System Thinking - Focused on Anteo Eco Park - (시스템 사고를 통한 다기능 생태저류지의 관리방안 - 광명 안터생태공원을 중심으로 -)

  • Lee, HyunJi;You, Soojin;Chon, Jinhyung
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.18 no.2
    • /
    • pp.1-17
    • /
    • 2015
  • Ecological reservoir is a multifunctional space where provides the functions of retention, animal habitat and improvement of ecosystem health and landscape. The ecological reservoir of Anteo Eco Park located in Gwangmyeong-si has established to functions for water purification, maintenance of healthy aquatic ecosystem. Because the Anteo Eco Park is located in the site where nonpoint pollutant materials flow in, Anteo Eco Park has potential factors which aquatic ecosystem health deteriorates and damages the habitat of golden frog(Rana plancyi chosenica) which is restoration target species. Therefore, the purpose of this study is to suggest the plan to manage the variables which impede the right functions of aquatic ecosystem by understanding the causal loop diagram for the change of water quality environment and the interaction of predator-prey through system thinking. The results are as follows. First, the study showed that the individual number of golden frog which is an indicator species of Anteo Eco Park is threatened by snakeheaded fish, which is an upper predator. Therefore, balanced food chain should be hold to protect golden frog by capturing the snakeheaded fish which is individual number's density is high, and the monitoring management of the individual number for predator(snakeheaded fish)-prey(golden frog) should be performed. Second, the study represented that water pollution and carnification is caused by the sediment as the dead body of the large emergent vegetation in the winter cumulates as sediment. Ecological reservoir in Anteo Eco Park has been managed by eliminating the dead body of the large emergent vegetation, but the guideline for the proper density maintenance of vegetation community is additionally needed. Lastly, the study showed that aquatic ecosystem of Anteo Eco Park where is contaminated from the inflow of nonpoint pollutants affects the individual number's decline of golden frog and snakeheaded fish. Accordingly, the creation of a buffer area and a substitution wetland is needed in the periphery of the Anteo Eco Park to control the inflow of nonpoint pollutants including organic matters, nutrients and heavy metals. This study will be helpful that Anteo Eco Park improves the regional landscape and maintain healthy aquatic ecosystem space for the park visitors including local residents.

Pollutants Characteristics of Surface Runoff from the Industrial Complex (산업공단에서의 지표유출수 오염물질 특성)

  • Kim, Youn-Kwon;Shin, Eung-Bai;Lee, Doo-Jin;Pae, Yo-sop;Yoon, Hyun-Sik
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.4
    • /
    • pp.689-698
    • /
    • 2000
  • The quality of stormwater runoff has been a major concern in water quality preservation. Characteristics of heavy metals and conventional pollutants in surface runoff from industrial complex, during the first flush, were not completely understood, Generally, separated sewer system is known for their water quality with untreated wastewater during storm events. In this study, the quality and characteristics of surface runoff from the industrial complex were investigated. The target area in the industrial complex catchment was divided 4 sub-areas, and the quality of stormwater runoff from the selected drainage areas was investigated using a grab sampling method. The petro-chemical industry and the junkyard discharged relatively high concentration of conventional pollutants, such as BOD, COD, SS, and TN through the first flush runoff samples. On the other hand, a higher level of heavy metals was found in the first flush runoff from the metal-mechanical industry and the scrap storage yard. For metals, Fe, Zn and Cu were the most prevalent species found in the first flush runoff from all sites for every surface runoff samples, while Pb, As, Cd, Cr and Ni were the least prevalent species and Hg was not found in any sample at any site. These results suggest that the nature of pollutants in surface runoff from the industrial complex was related to the type of industry, and the concentration of pollutants was determinated by the degree of exposed pollutant sources and the characteristic of rainfall events at the sites.

  • PDF

Characteristics of a Wet Air Cleaning System for Removal of Air Pollutants (습식 공기청정장치의 공기오염물질 제거 특성)

  • Bae, Gwi-Nam;Kim, Yong Pyo;Baik, Nam Jun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.1
    • /
    • pp.21-31
    • /
    • 2000
  • Performance characteristics of a wet air cleaning system were investigated experimentally, and discussed in relation with physicochemical properties of the target pollutants. The system is composed of an air cleaner, a separator, and a medium filter. Removal efficiency of the system was measured for ambient particles and gaseous air pollutants: $SO_2$, NO, $NO_2$, HCHO, and $NH_3$. For particle removal test, particles were introduced into the system through a fan, and the particle size distribution was measured at three locations by using two laser particle counters. Particle removal efficiency for each system component was obtained from the particle size distribution. It was found that the separator primarily removed coarse particles greater than $5{\mu}m$ in diameter, and that the medium filter mainly removed fine particles less than $5{\mu}m$ in diameter. For gas removal test, air with gaseous air pollutant was injected into the outlet of the fan, and the concentration was measured both at the upstream of the air cleaner and at the downstream of the separator. It was found that the gaseous species with high Henry's law coefficients, such as $SO_2$, HCHO, and $NH_3$, showed high removal efficiency, but the gaseous species with low Henry's law coefficients, such as NO and $NO_2$, showed low removal efficiencies. It was also found that negative ions were generated from the air cleaner.

  • PDF

Characteristics of pollutant emission from wallpapers - Around TVOC and HCHO - (벽지에서 발생되는 오염물질 방출특성 - TVOC와 HCHO를 중심으로 -)

  • Jang, Seong-Ki;Kim, Mi-Hyun;Lee, Hong-Suk;Lim, Jun-Ho;Jang, Mee;Seo, Soo-Yun
    • Analytical Science and Technology
    • /
    • v.18 no.6
    • /
    • pp.542-551
    • /
    • 2005
  • This study is to investigate the characteristics of emission concentration according to wallpaper sort and emission time using small chamber method. The target compounds included 45 VOCs and formaldehyde, which were respectively determined by adsorption sampling and thermal desorption coupled with GC/MS method, and by sampling in DNPH cartridge and HPLC method. The emission factor of TVOC and HCHO was detected to $1.1mg/m^2{\cdot}h$ and $0.01mg/m^2{\cdot}h$ respectively, and the wallpapers of 25 satisfied emission standard. TVOC emission factor appeared in order of the concentration of PVC, natural, and Non-PVC wallpaper, while HCHO was detected very low concentration without relation to wallpaper sort. The paraffin hydrocarbons appeared to be the most contributable class of hydrocarbons in terms of their concentrations, followed by aromatics, and olefins, halogenated hydrocarbons was not detected. PVC wallpapers plentifully emitted TVOC above other wallpapers, and toluene was showed higher concentration of 10 times than natural wallpaper. In addition to, emission factor according to elapse was gradually decreased.

Evaluation of Decomposition Characteristics of Organochlorine Pesticides Using Thermal Method (열적방법을 활용한 유기염소계 폐농약의 분해 특성 평가)

  • Kwon, Eun-Hye;Yoon, Young-Sam;Bea, Ji-Su;Jeon, Tae-Wan;Lee, Young-Ki
    • Journal of Korea Society of Waste Management
    • /
    • v.35 no.8
    • /
    • pp.744-753
    • /
    • 2018
  • The Stockholm Convention, which was adopted in Sweden in 2001 to protect human health and the environment, includes regulations for Persistent Organic Pollutant Rotors such as toxic and bioaccumulatives. Currently, there are 28 types of materials. This prohibits and limits the production, use, and manufacture of products. Korea is a member of the Convention, and it is necessary to prepare management and treatment plans to address the POP trends. Thus, we experimentally investigate whether the environmentally stable incineration is achieved when the sample is thermally treated using the Lab-scale (1 kg/hr). The target samples is pesticides in liquid phase and solid phase. In this study, organic chlorinated pesticides and their thermal characteristics were analyzed. We calculated the theoretical air volume based on the element analysis results. Because the interior of the reactor is small, more than 10 times of the air ratio was injected. The retention time was set to at least 4 seconds using a margin. The incineration temperature was $850^{\circ}C$ and $1100^{\circ}C$. Thus, we experimentally investigated whether the environmentally stable incineration was achieved when the sample was thermally treated using the Lab-scale (1 kg/hr). We analyzed five types of exhaust gas; the 02 concentration was high, but the CO amount decreased. Complete combustion is difficult because of the small size of the furnace due to the nature of Lab-scale. The organic chlorine-containing pesticide had an average decomposition rate of 99.9935%. Considering the decomposition rates of organic chlorine-containing pesticide in this study, the incineration treatment at over 2 ton/hour, which is typical for a conventional incinerator, is possible. Considering the occurrence of dioxins and unintentional persistent organic pollutants, it can operate at more than $1,100^{\circ}C$.

A Study on Green Space Location Selection to Reduce Particulate Matter by Projecting Distributions of Emission Source and Vulnerable Groups - focusing on Seongdong-gu, Seoul - (미세먼지 배출원과 취약계층 분포 추정을 통한 미세먼지 저감 녹지 입지 선정 연구 - 서울시 성동구를 대상으로 -)

  • Shin, Ye-Eun;Park, Jin-Sil;Kim, Su-Yeon;Lee, Sang-Woo;An, Kyung-Jin
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.24 no.1
    • /
    • pp.53-68
    • /
    • 2021
  • The study aims to propose a locating method of green space for reducing Particulate Matter (PM) in ambient air in conjunction with its source traces and vulnerable groups. In order to carry out the aims and purposes, a literature review was conducted to derive indicators of vulnerable area to PM. Based on the developed indicators, the vulnerable areas and green spaces creation strategies for each cluster were developed for the case of Seongdong-gu, Seoul. As a result, six indicators for vulnerability analysis were came out including the vulnerable groups (children's facilities, old people's facilities), emission sources (air pollutant emission workplaces, roads), and environmental indicators (particulate matter concentration, NDVI). According to the six selected indicators, the target area was divided into 39 hexagons and analyzed to result the most vulnerable areas to particulate matter. As a result of comprehensive vulnerability analysis, the Seongsu-dong area was found to be the most vulnerable to particulate matter, and 5 clusters were derived through k-means cluster analysis. Cluster 1 was analyzed as areas that most vulnerable to particulate matter as a result of the comprehensive analysis, therefore urgent need to create green spaces to reduce particulate matter. Cluster 2 was areas that mostly belonged to the Han River. Cluster 3 corresponds to the largest number of hexagons, and since many vulnerable groups are distributed, it was analyzed as a cluster that required the creation of a green spaces to reduce particulate matter, focusing on facilities for vulnerable groups. Three hexagons are included in cluster 4, and the cluster has many roads and lacks vegetation in common. Cluster 5 has a lot of green spaces and is generally distributed with fewer vulnerable groups and emission sources; however, it has a high level of particulate matter concentration. In a situation where various green spaces creation projects for reducing particulate are being implemented, it is necessary to consider the vulnerable groups and emission sources and to present green space creation strategies for each space characteristic in order to increase the effectiveness of such projects. Therefore, this study is regarded as meaningful in suggesting a method for selecting a green area for reducing PM.

Study on Gas Concentration Measurement of O2 and NO Using Calibration-free Wavelength Modulation Spectroscopy in Visible and Mid-Infrared Region (가시광선과 중적외선 영역의 무보정 파장 변조 분광법을 이용한 O2와 NO 가스 농도 측정에 관한 연구)

  • Aran Song;Geunhui Ju;Kanghyun Kim;Jungho Hwang;Daehae Kim;Changyeop Lee
    • Journal of the Korean Institute of Gas
    • /
    • v.27 no.1
    • /
    • pp.70-77
    • /
    • 2023
  • Air environment regulations have been strengthened due to increasing air pollutant emissions, the target of reducing emissions has increased and interest in gas measurement methods is also increasing. The sampling method is mainly used, but due to the spatial and temporal measurement limitations, the laser absorption spectroscopy which is a real-time and in-situ method is in the spotlight. In this study, we studied the wavelength modulation spectroscopy and described the calibration-free algorithm. The developed algorithm was modified to reflect 46 multi-absorption lines and was applied to light absorption signal analysis in visible and mid-infrared regions. In addition, the difference between the modulation parameters of laser was analyzed. As a result of reviewing the performance through O2 and NO gas measurement experiments of various concentration conditions, the linearity was R2O2=0.99999 and R2NO=0.99967.

Geochemical Characteristics of Soil Solution from the Soil Near Mine Tailing Dumps and the Contamination Assessment in Duckum Mine (토양수의 자구화학특성에 따른 금속폐광산 광미야적장주변 토양오염평가: 덕음광산)

  • 이상훈;정주연
    • Economic and Environmental Geology
    • /
    • v.37 no.1
    • /
    • pp.61-72
    • /
    • 2004
  • The soil samples were collected from the paddy field near the mine tailing dumps in the abandoned Duckum mine in Korea. In the laboratory, the soil solution was extracted from the soil using centrifuge, and analysed for the chemical composition. Physical and chemical soil properties were also analysed. Kaolinite is the main clay minerals in the paddy soil and the CEC value is therefore relatively low. Nearly all soil samples show enrichment in their trace elemental concentrations(Cd, Cu, Pb and Zn) compared with natural background level. Some soil samples exceed the soil remediation intervention values for Cd, Pb and Zn and target value for Cu, when compared with Dutch standard, whereas As, Ni and Cr are in normal range. Lead concentrations in some samples near the mine tailing dumps also exceed the standard for remediation act for agricultural area set by Korean soil conservation law. The trace elemental concentrations are higher in the paddy soil nearer the mine tailing dumps and lower for the samples from distance. Similar trend with distance is found for the soil solution chemistry but the decrease with distance from the mine tailing dumps are sharper than the changes in soil chemistry. Cadmium, Cu and Pb concentrations in the soil solution are very low, ranging from a tenth and hundredths to a maximum of several mg/l, whereas their concentrations in soils are highly enriched for natural background. Most of the trace elements are thought to be either removed by reduced iron sulphides or iron oxides, depending on the redox changes. Geochemical equilibrium modelling indicate the presence of solubility controlling solid phases for Cd and Pb, whereas Zn and Cu might have been controlled by adsorption/desorption processes. Although pollutants migration through solution phase are thought to be limited by adsorption onto various Fe, Mn solid phases, the pollutants exist as easily releasable fractions such as exchangeable site. In this case, the paddy soil would act as pollutant pool, which will supply to plants in situ. whenever the geochemical conditions favour.

Applicability Analysis of the HSPF Model for the Management of Total Pollution Load Control at Tributaries (지류총량관리를 위한 HSPF 모형의 적용성 분석)

  • Song, Chul Min;Kim, Jung Soo;Lee, Min Sung;Kim, Seo Jun;Shin, Hyung Seob
    • Ecology and Resilient Infrastructure
    • /
    • v.9 no.1
    • /
    • pp.1-14
    • /
    • 2022
  • The total maximum daily load (TMDL) implemented in Korea mainly manages the mainstream considering a single common pollutant and river discharge, and the river system is divided into unit watersheds. Changes in the water quality of managed rivers owing to the water quality management in tributaries and unit watersheds are not considered when implementing the TMDL. In addition, it is difficult to consider the difference in the load of pollutants generated in the tributary depending on the conditions of the water quality change in each unit watershed, even if the target water quality was maintained in the managed water system. Therefore, it is necessary to introduce the total maximum load management at tributaries to manage the pollution load of tributaries with a high degree of pollution. In this study, the HSPF model, a watershed runoff model, was applied to the target areas consisting of 53 sub-watersheds to analyze the effect of water quality changes the in tributaries on the mainstream. Sub-watersheds were selected from the three major areas of the Paldang water system, including the drainage basins of the downstream of the South Han-River, Gyeongan stream, and North Han-River. As a result, BOD ranged from 0.17 mg/L to 4.30 mg/L, and was generally high in tributaries and decreased in the downstream watershed. TP ranged from 0.02 mg/L - 0.22 mg/L, and the watersheds that had a large impact on urbanization and livestock industry were high, and the North Han-River basin was generally low. In addition, a pollution source reduction scenario was selected to analyze the change in water quality by the amount of pollution load discharged at each unit watershed. The reduction rate of BOD and TP according to the scenario changes was simulated higher in the watershed of the downstream of the North Han-River and downstream and midstream of the Gyeongan stream. It was found that the benefits of water quality reduction from each sub-watershed efforts to improve water quality are greatest in the middle and downstream of each main stream, and it is judged that it can be served as basic data for the management of total tributaries.

Environmental Assessment and Decision of Remediation Scope for Arsenic Contaminated Farmland Soils and River Deposits Around Goro Abandoned Mine, Korea (토양 정밀 조사에 의한 고로폐광산 주변 비소오염 토양 및 하천퇴적토의 오염도 평가 및 오염 토양 복원 규모 설정)

  • 차종철;이정산;이민희
    • Economic and Environmental Geology
    • /
    • v.36 no.6
    • /
    • pp.457-467
    • /
    • 2003
  • Soil Precise Investigation(SPI) for river deposits and farmland soils around Goro abandoned Zn-mine, Korea was performed to assess the pollution level of heavy metals(As. Pb, Cd, Cu) and to estimate the remediation volume for contaminated soils. Total investigation area was about 950000 $m^2$, which was divided into each section of 1500 $m^2$ corresponding to one sampling site and 545 samples for surface soil(0-10cm in depth) and 192 samples for deep soil(10-30cm in depth) from the investigation area were collected for analysis. Concentrations of Cu, Cd, Pb at all sample sites were shown to be lower than Soil Pollution Warning Limit(SPWL). For arsenic concentration, in surface soils, 20.5% of sample sites(104 sites) were over SPWL(6mg/kg) and 6.7%(34 sites) were over Soil Pollution Counterplan Limit(SPCL: 15mg/kg) suggesting that surface soils were broadly contaminated by As. For deep soils, 10.4% of sample sites(18 sites) were over SPWL and 0.6%(1 site) were over SPCL. Four pollution grades for sample locations were prescribed by the Law of Soil Environmental Preservation and Pollution Index(PI) for each soil sample was decided according to pollution grades(over 15.0 mg/kg, 6.00-15.00 mg/kg, 2.40-6.00 mg/kg, 1.23-6.00 mg/kg). The pollution contour map around Goro mine based on PI results was finally created to calculate the contaminated area and the remediation volume for contaminated soils. Remediation area with over SPWL concentration was about 0.3% of total area between Goro mine and a projected storage dam and 0.9% of total area was over 40% of SPWL. If the remediation target concentration was determined to over background level concentration, 1.1% of total area should be treated for remediation. Total soil volume to be treated for remediation was estimated on the assumption that the thickness of contaminated soil was 30cm. Soil volume to be remediated based on the excess of SPWL was estimated at 79,200$m^3$, soil volume exceeding 40% of SPWL was about 233,700 $m^3$, and soil volume exceeding the background level(1.23 mg/kg) was 290,760 TEX>$m^3$.