• Title/Summary/Keyword: Target pollutant

Search Result 121, Processing Time 0.025 seconds

A Review of Constructed Wetlands for Water Quality Management in India

  • Farheen, Shaista;Geronimo, Franz Kevin;Guerra, Heidi;Reyes, Nash Jett;Choi, Hyseon;Jeon, Minsu;Kim, Lee-Hyung
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2021.06a
    • /
    • pp.129-129
    • /
    • 2021
  • Constructed wetlands (CW) are artificially developed wetlands that are used to control water pollution. In central India, the field application of CW started on the late 1990s but are mostly focused on wastewater treatment. In this paper, different existing and experimental studies on constructed wetlands were reviewed to be able to determine the current status of wetlands in India to identify the type of CW that is more suitable in managing a specific target pollutant and type of wastewater. Wetlands were categorized into three types: vertical flow, horizontal flow, and hybrid while the wastewater were classified as domestic and industrial. Based on the review, 80% of constructed wetlands are used for treating domestic wastewater while 20% are treating industrial wastewater. Inflow analysis showed that industrial wastewater in hybrid constructed wetland produced the highest average concentration for parameters like COD (2851 mg/L) and BOD (5715 mg/L) while the lowest concentration was TN (13.97 mg/L) found in municipal wastewater. In terms of removing nonpoint source pollutants, it was revealed that vertical flow constructed wetlands (VFCW) are more effective at removing TSS and BOD as compared to horizontal flow constructed wetlands (HFCW) and hybrid constructed wetlands (HCW). HCW were found to be capable of efficiently removing COD and TN. Meanwhile, HFCW showed the highest TP removal among all the types of wetlands. In addition, VFCW were more effective for domestic wastewater while HCW are more effective for treating industrial wastewater. Lastly, there is currently a need to conduct further research on constructed wetlands for industrial wastewater as well as stormwater treatment to be able to gather more data and improve wetland design, performance, and maintenance.

  • PDF

A Study on the Assessment of Pollution Loads at Small Stream in Yeongsan River Watershed (영산강수계 소하천의 오염부하량 평가에 관한 연구)

  • Ha, Don-Woo;Shim, Hongbin;Kim, Haesung;Kim, Yoonsoo;Cho, Sohyun;Song, Chang-Soo;Kang, Taegu;Kim, Yeong-Suk
    • Journal of Korean Society on Water Environment
    • /
    • v.34 no.1
    • /
    • pp.1-9
    • /
    • 2018
  • In this study, the load of the river was calculated by using the actual data of the Yeong-bon C1, Yeong-bon C2, Yeong-bon C3 monitoring points of the Yeong-san river watershed to determine the excess. As a result, the BOD is 75.83 % at the Yeong-bon C1 and the five-year average value is higher than at other points. The Yeong-bon C3 was 72.15 % and Yeong-bon C2 was analyzed as 68.78 %. The five-year average of the T-P was 71.95 % for the Yeong-bon C2 and 69.86 % for the Yeong-bon C3 and 69.16 % for Yeong-bon C1; these levels exceeded the target water quality standards of 50 %. As a result of analyzing the pollutant load, we found that the Yeong-bon C1 has been highly affected by the nonpoint pollution source because the excess rate is high in the upper section of the flow rate. The Yeong-bon C2 showed a high excess rate in the lower part of the flow rate, and it was estimated that the influence of the point pollution source was large. The excess rate of the Yeong-bon C3 is small in the interval deviation, and it was evaluated as being affected by both point and non-point pollution sources. The TMDL monitoring network data were used to estimate the exceed ratio for the target water quality assessment, and the implementation evaluation was made by the flow exceedance probability interval to analyze the monitoring data so that the data could be utilized according to the purpose of the measurement network.

Water Quality Prediction and Forecast of Pollution Source in Milyanggang Mid-watershed each Reduction Scenario (밀양강 중권역 오염부하 전망 및 삭감 시나리오별 하류 수질예측)

  • Yu, Jae-Jeong;Yoon, Young-Sam;Shin, Suk-Ho;Kwon, Hun-Gak;Yoon, Jong-Su;Jeon, Young-In;Kang, Doo-Kee;Kal, Byung-Seok
    • Journal of Environmental Science International
    • /
    • v.20 no.5
    • /
    • pp.589-598
    • /
    • 2011
  • Milyanggang mid-watershed is located in downstream of Nakdong river basin. The pollutants from that watershed have an direct effect on Nakdong river water quality and it's control is important to manage a water quality of Nakdong river. A target year of Milyanggang mid-watershed water environment management plan is 2013. To predict a water quality at downstream of Milyang river, we have investigated and forecasted the pollutant source and it's loading. There are some plan to construction the sewage treatment plants to improve the water quality of Milyang river. Those are considered on predicting water quality. As results, it is shown that the population of Milyanggang mid-watershed is 131,857 and sewerage supply rate is 62.2% and the livestock is 1,775.300 in 2006. It is estimated that the population is 123,921, the sewerage supply rate is 75.5% in 2013. The generated loading of BOD and TP is 40,735 kg/day and 2,872 kg/day in 2006 and discharged loading is 11,818 kg/day and 722 kg/day in 2006 respectively. Discharged loadings were forecasted upward 1.0% of BOD and downward 2.7% of TP by 2013. The results of water quality prediction of Milyanggang 3 site were 1.6 mg/L of BOD and 0.120 mg/L of TP in 2013. It is over the target water quality at that site in 2015 about 6.7% and 20.0% respectively. Consequently, there need another counterplan to reduce the pollutants in that mid-watershed by 2015.

EMC and Unit Loads of Pollutants Generated from Tomato Cultivation during Rainfall (강우시 시설재배지역의 오염물질 유출 EMC 및 원단위 산정)

  • Jeon, Je Chan;Kwon, Koo Ho;Lee, Sang Hyeub;Lee, Jea Woon;Gwon, Heun Gag;Min, Kyung Sok
    • Journal of Wetlands Research
    • /
    • v.15 no.4
    • /
    • pp.555-566
    • /
    • 2013
  • Total maximum daily load enforced in 2004 is a program to evaluate the amount of pollutants by each land use type and manage to meet a target water quality of each waterbody. The many research to calculate runoff load of pollutants by landuse type have been studied. This study was conducted to calculate pollutants EMC, load and unit load in stormwater runoff generated from tomato growing area. Monitoring was conducted about 32 event during 4years and water quality parameters such as BOD, $COD_{Mn}$, TOC, TSS, TN, TP, $NH_3-N$, $NO_3-N$, $PO_4-P$ were analyzed at the laboratory. The average EMC were measured as follows: 9.6 BOD mg/L, 17.2 $COD_{Mn}$ mg/L, 5.5 TOC mg/L, 319.4 TSS mg/L, 4.4 T-N mg/L, 2.6 T-P mg/L, 0.5 $NH_3-N$ mg/L, 0.04 $NO_2-N$ mg/L, 2.6 $NO_3-N$ mg/L, 0.8 $PO_4-P$ mg/L. TN and TP is dichargeed as $NO_3-N$ and particle phosphorus type, respectively.

Evaluation of Eutrophication and Control Alternatives in Sejong Weir using EFDC Model (EFDC 모델에 의한 세종보의 부영양화 및 제어대책 평가)

  • Yun, Yeojeong;Jang, Eunji;Park, Hyung-Seok;Chung, Se-Woong
    • Journal of Environmental Impact Assessment
    • /
    • v.27 no.6
    • /
    • pp.548-561
    • /
    • 2018
  • The objectives of this study were to construct a three-dimensional (3D) hydrodynamic and water quality model (EFDC) for the river reach between the Daecheong dam and the Sejong weir, which are directly affected by Gap and Miho streams located in the middle of the Geum River, and to evaluate the trophic status and water quality improvement effect according to the flow control and pollutant load reduction scenarios. The EFDC model was calibrated with the field data including waterlevel, temperature and water quality collected from September, 2012 to April, 2013. The model showed a good agreement with the field data and adequately replicated the spatial and temporal variations of water surface elevation, temperature and water quality. Especially, it was confirmed that spatial distributions of nutrients and algae biomass have wide variation of transverse direction. Also, from the analysis of algal growth limiting factor, it was found that phosphorous loadings from Gap and Miho streams to Sejong weir induce eutrophication and algal bloom. The scenario of pollutant load reduction from Gap and Miho streams showed a significant effect on the improvement of water quality; 4.7~18.2% for Chl-a, 5.4~21.9% for TP at Cheongwon-1 site, and 4.2~ 17.3% for Chl-a and 4.7~19.4% for TP at Yeongi site. In addition, the eutrophication index value, identifying the tropic status of the river, was improved. Meanwhile, flow control of Daecheong Dam and Sejong weir showed little effect on the improvement of water quality; 1.5~2.4% for Chl-a, 2.5~ 3.8% for TP at Cheongwon-1 site, and 1.2~2.1% for Chl-a and 0.9~1.5% for TP at Yeongi site. Therefore, improvement of the water quality in Gap and Miho streams is essential and a prerequirement to meet the target water quality level of the study area.

Transport of nonpoint source pollutants and stormwater runoff in a hybrid rain garden system (하이브리드 빗물정원 시스템에서의 비점오염물질 및 강우유출수 이송 특성)

  • Flores, Precious Eureka D.;Maniquiz-Redillas, Marla C.;Geronimo, Franz Kevin F.;Alihan, Jawara Christian P.;Kim, Lee-Hyung
    • Journal of Wetlands Research
    • /
    • v.18 no.4
    • /
    • pp.481-487
    • /
    • 2016
  • In this research, a pilot scale hybrid rain garden system was developed in order to investigate the efficiency in the different components of the hybrid rain garden system and at the same time evaluate the initial efficiency of the system in treating urban stormwater runoff prior to its actual use in the field. Experimental runs were conducted using synthetic runoff having target concentrations similar to that of the typical runoff characteristics found in different countries and in Korea. With the employment of the hybrid rain garden system, hydrologic improvement was observed as the system demonstrates an approximately 95% reduction in the influent runoff volume with 80% retained in the system, and 15% recharged to groundwater. The reduction was contributed by the retention capabilities of ST and infiltration capabilities in PB and IT. With the combined mechanisms such as filtration-infiltration, biological uptake from plants and soil and phytoremediation that are incorporated in PB and IT, the system effectively reduces the amount of pollutant concentration wherein the initial mean removal efficiency for TSS is 87%, while an approximate mean removal efficiency of 76%, 46% and 56% was observed in terms of organics, nutrients and heavy metal, respectively. With these findings, the research helps in the further improvement, innovation and optimization of rain garden systems and other facilities as well.

Establishment of Resilient Infrastructures for the Mitigation of an Urban Water Problem: 2. Robustness Assessment of Structural Alternatives for the Problems of Water Pollution (도시 물 문제 저감을 위한 회복탄력적 사회기반시설 구축: 2. 수질오염 문제 구조적 대안의 내구성 평가)

  • Jung, Jihyeun;Lee, Changmin;An, Jinsung;Kim, Jae Young;Choi, Yongju
    • Ecology and Resilient Infrastructure
    • /
    • v.3 no.3
    • /
    • pp.182-188
    • /
    • 2016
  • This study evaluated structural alternatives for managing water quality problems by reinterpreting and then applying the robustness-cost index (RCI) for urban flood problems. Cases of endogenous hormone pollution in treated sewage and proliferation of protozoa in intake-water were chosen as representative examples because they have different types of regulation standards for the treatment. Current facilities and structural alternatives with robustness indices (RIs) greater than unity were determined to be robust. The RI was combined with the cost index (CI) to obtain the RCI values. For the endogenous hormone pollution in treated sewage, a human-oriented estrogen $17{\beta}$-estradiol was selected as a target pollutant. The RI and RCI values for a structural alternative, extension of the current sewage treatment facility for advanced treatment, were greater than the values for the current practice of conventional activated sludge process. For the intake-water pollution by protozoa, UV and ozone disinfection facilities were evaluated for inactivation of Cryptosporidium parvum. The RCI values for ozone disinfection were greater than those for UV disinfection. Based on the results and the logics involved in the calculation of RCI for water quality issues we studied, we proposed procedures for establishing and implementing structural alternatives for the restoration from and prevention of outbreaks of water quality problems.

Agriculture Pollution and its Countermeasures with Special Consideration of Pesticides (작물생산과 농업공해 및 그 대책)

  • Li, Gwo-Chen
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.27 no.4
    • /
    • pp.340-360
    • /
    • 1982
  • Because of the continuing rapid increase in pesticide usage in Taiwan, much attention has been focus on pesticide contamination of food and effect of pesticides on human and environmental health. The Plant Protection Center (PPC) conducts safety evaluation of pesticides usee! in Taiwan. The pesticides are classified into different groups based on their acute toxicities. Pesticides which are classified into extremely toxic group are not allow to used on short term crops or the continuously harvest crops. The acute toxicity of pesticides to the beneficial insects are also studied, special attention has been paid to the two predators of rice brown planthopper. 60% of cultivated land in Taiwan are paddy field; therefore, acute fish toxicity was taken into consideration when a pesticide was applied for registration to be used in the paddy. Fish toxicities were evaluated by the dangerous rating value which is the amount of pesticide residue in the field water over the TLM value. Mutagenicity of pesticides was continuously evaluated by using Arne's microbial testing method. Island wide survey of residual levels of pesticides of known pollutants such as chlorinated hydrocarbon . insecticides, mercurial compounds in soil, water and biological samples were carried out constantly. The potential of a new1y Imported esticides to pollute the environment were studied by using model ecosystem. Ecological magnification (EM) of a chemical was calculated from model ecosystem. A chemical was considered as a pollutant when its EM value over 5000. In order to ensure the levels of pesticides residue of the crop within the safety limit. The 'tolerance' of pesticides on different crop groupings were established base on 1) acceptable daily intake value of individual pesticides, 2) average daily consumption of each crop groupings by Chinese person, 3) Actual residues of pesticides. on different crops obtained from supervised trials. Total about 79 pesticides for which the tolerances have been established on different crop groupings. Because the intensive agricultural system was adopted in Taiwan. The phytotoxicity of pesticides to the non-target crops was therefore become one of the important factor in the safety evaluation of pesticide usage. These will include 1) direct injury, 2) injury caused by pesticide polluted irrigation water, 3) injury caused by the pesticide polluted soil, 4) reduction of growth caused by the effect of pesticide on the soil microorganisms. This paper will reviewed all the aspects mentioned in the previous .paragraphs. Most the works have done in Taiwan by the PPC.y the PPC.

  • PDF

Spatial-temporal Assessment and Mapping of the Air Quality and Noise Pollution in a Sub-area Local Environment inside the Center of a Latin American Megacity: Universidad Nacional de Colombia - Bogotá Campus

  • Fredy Alejandro, Guevara Luna;Marco Andres, Guevara Luna;Nestor Yezid, Rojas Roa
    • Asian Journal of Atmospheric Environment
    • /
    • v.12 no.3
    • /
    • pp.232-243
    • /
    • 2018
  • The construction, development and maintenance of an economically, environmentally and socially sustainable campus involves the integration of measuring tools and technical information that invites and encourages the community to know the actual state to generate positive actions for reducing the negative impacts over the local environment. At the Universidad Nacional de Colombia - Campus $Bogot{\acute{a}}$, a public area with daily traffic of more than 25000 people, the Environmental Management Bureau has committed with the monitoring of the noise pollution and air quality, as support to the campaigns aiming to reduce the pollutant emissions associated to the student's activities and campus operation. The target of this study is based in the implementation of mobile air quality and sonometry monitoring equipment, the mapping of the actual air quality and noise pollution inside the university campus as a novel methodology for a sub-area inside a megacity. This results and mapping are proposed as planning tool for the institution administrative sections. A mobile Kunak$^{(R)}$ Air & OPC air monitoring station with the capability to measure particulate matter $PM_{10}$, $PM_{2.5}$, Ozone ($O_3$), Sulfur Oxide ($SO_2$), Carbon Monoxide (CO) and Nitrogen Oxide ($NO_2$) as well as Temperature, Relative Humidity and Latitude and Longitude coordinates for the data georeferenciation; and a sonometer Cirrus$^{(R)}$ 162B Class 2 were used to perform the measurements. The measurements took place in conditions of academic activity and without it, with the aim of identify the impacts generated by the campus operation. Using the free code geographical information software QGIS$^{(R)}$ 2.18, the maps of each variable measured were developed, and the impacts generated by the operation of the campus were identified qualitative and quantitively. For the measured variables, an increase of around 21% for the $L_{Aeq}$ noise level and around 80% to 90% for air pollution were detected during the operation period.

Variation of Pollutant Removal Efficiency and Backwashing Effect of BAC Basin in Advanced Water Treatment Processes (고도정수공정에서 오염물질 제거효율 변화특성과 BAC조의 역세척에 따른 영향)

  • Park, Soo-Yee;Lee, Sang-Bong;Sin, Sang-Min;Jun, Chang-Jea;Kim, Chang-Won
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.30 no.1
    • /
    • pp.45-53
    • /
    • 2008
  • In this paper, the property of influent water and variations of removal efficiencies in each unit processes were studied based on the experiment data from the advanced water treatment plant in a city of Korea. The microbial species in the biological activated carbon(BAC) after backwashing of activated carbon filtration tank(ACFT) were also identified. The property and the removal efficiencies were evaluated by considering 8-9 items. The variations of 4 items were investigated from the influent and effluent of ACFT. SEM recording were conducted on BAC samples before and after backwashing. And the existence of attached microorganisms were identified through HPC(Heterotrophic Plate Counter) investigation. For the property of influent water, the concentrations of most items were maintained in the constant ranges, some items had seasonal properties. For the removal efficiencies, there were some items showing similar monthly-pattern and increasing with time, other items decreasing at the ozone contactor. Through these investigations, it was possible to distinguish the target items, which were removed by the advanced processes. The existence of microorganisms in ACFT could be predicted based on the variation curve of NH$_3$-N, and this fact were proved by SEM and HPC.