Development and Implementation of a Skill Transfer System for a Self-Tapping Screw-Tightening Operation

  • Matsumoto, Toshiyuki;Doyo, Daisuke;Shida, Keisuke;Kanazawa, Takashi
    • Industrial Engineering and Management Systems
    • /
    • 제10권3호
    • /
    • pp.209-220
    • /
    • 2011
  • Self-tapping screws have some operational peculiarities. In spite of their economical advantage that requires no prior tapping operation, a weakness of self-tapping screw-tightening operations is that screws can easily be tightened at a non-right angle, thus resulting in an improper tightening strength. Increases in outsourced workers have reduced labor costs, but the accompanying high worker fluidity means that new workers are more frequently introduced into factories. It is necessary to train new workers for self-tapping screw-tightening operations, which occupies a considerable portion of ordinary assembly works. The purpose of this study is to develop and implement a skill transfer system for the operation. This study (1) proposes a set of characteristic values for evaluating the quality of the operation and develops a device that can measure these values; (2) proposes criteria for evaluating the resultant quality of the tightening; and (3) develops a skill training system for better work performance. Firstly, sets of characteristic values for evaluating the quality of the operation, namely, torque, vertical pressure forces and horizontal vibration forces, are proposed. A device that can measure these values is developed. Secondly, criteria for evaluating the resultant quality of the tightening are identified, involving tightening torque, maximum vertical pressure and timing, vibration area during the processing and tightening period, and work angle. By using such parameters, workers with the proper aptitude can be identified. Thirdly, a skill training system for the operation is developed. It consists of screwdriver operation training and screw-tightening training with feedback information about the results of the operation. Finally, the validity of the training system is experimentally verified using new operators and actual workers.

피치가 다른 다축 태핑에서의 가공 특성과 품질 평가에 관한 연구 (A Study on the Multi Tapping Process Characteristics and Tread Quality under Difference Pitch)

  • 이종형;이창헌;김영문;이상영;이상중
    • 한국산업융합학회 논문집
    • /
    • 제9권4호
    • /
    • pp.277-283
    • /
    • 2006
  • As the products such as HDD, Notebook, PDA, and Mobile Phone become smaller and thinner, the radius of threads as well as holes for assembling those products become smaller, even down to 1mm. To produce such small holes and thread efficiently, multi tapping is highly necessitated. However the multi tapping characteristics is not well known because its complicated cutting mechanism and thus the quality of the produced holes and threads is not well studied yet. In this paper, experiments have been conducted for small-radius threads using M2 and M2.6 and M3 cold forming tap to investigate multi tapping process using several useful signal such as torque and Z-axis encoder pulse. The surface and profile of the machined threads have been magnified and observed through a SEM.

  • PDF

Self drilling과 Self-tapping microscrew implants의 조직학적 및 생역학적인 비교 (Histologic and biomechanical characteristics of orthodontic self-drilling and self-tapping microscrew implants)

  • 박효상;슈엔;정성화
    • 대한치과교정학회지
    • /
    • 제36권4호
    • /
    • pp.295-307
    • /
    • 2006
  • 이 연구의 목적은 교정용 고정원으로 사용된 self-drilling과 self-tapping microscrew implants를 조직학적 및 생역적으로 비교하는 것이다. 28 마리의 가토에 112개의 microscrew implants (56개의 self-drilling microscrew implants 와 56개의 self-tapping microscrew implants)를 식립하였다. Self-tapping microscrew implants는 0.9 mm 드릴로서 홈을 형성한 후 식립하였고 self-drilling microscrew implants는 홈을 형성하지 않고 바로 식립하였다. 교정력은 식립 직후 바로 NiTi coil spring을 연결하여 가하였으며 일부는 교정력을 가하지 않았고 일부는 100 gm정도의 약한 교정력을 일부는 200 gm정도의 강한 교정력을 가하였다. 실험동물은 3주 혹은 5주에 희생하였으며 72개의 비탈회 표본을 만들어 전반적인 조직학적 관찰과 조직 계측을 시행하였다. 토크 게이지로 최대 식립 토크와 최대 제거 토크를 측정하였다. 모든 microscrew implants는 실험기간 동안 안정되게 유지되었고 최대 제거 토크의 측정에는 self-drilling과 self-tapping microscrew implants 사이에 통계학적으로 유이한 차이가 없었다. 조직 관찰에서 self-tapping microscrew implants에서 골 임프란트 계면에 골결손이 더 많았고 5주에서는 새로이 형성된 미성숙 골이 더 많았다. Self-drilling microscrew implants에서 골표면 혹은 골내막으로의 골 형성이 많이 관찰되었으나 5주에서는 흡수되는 양상을 보였다. 3주에서는 self-drilling microscrew implants가 더 많은 골접촉을 보였으나 5주에서는 두 군사이에 차이가 관찰되지 않았다. 이 결과는 두 방법이 모두 microscrew implant의 식립에 사용될 수 있음을 시사하나 self-tapping microscrew implants의 경우 초기에는 약한 힘을 가하는 것이 좋을 것으로 생각된다.

탭 형상에 따른 공구마모 특성에 관한 연구 (A Study About Tool Wear Characteristic on Geometry of Tap)

  • 최만성;윤홍기
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2000년도 추계학술대회 논문집
    • /
    • pp.892-897
    • /
    • 2000
  • In this study, tap wear was analyzed not only to predict the tap life time but also to propose an improved tap design. Because rake angle and thread relief of tap are the significant factors in geometry of tap, these two factors were picked as the experiment variables. The experiment was conducted with six types of tap which have 6$^{\circ}$ , 8$^{\circ}$ and 12$^{\circ}$ of rake angles with 0,08mm and 0.14 mm of thread relief. From the measured cutting force, it could be known that cutting torque was low at the large the rake thread relief and tool life was long as rake angle became large. Eventually, tool life is longest when rake angle is 12$^{\circ}$ and the with 0.08mm thread relief. Aand the width of crater wear and that of flank wear were measured when a tapping torque was 20 [$kg_f$-mm] . Most of the measured values were above the width of tool wear[$V_B$=O.O3m], which means that tool life is over.

  • PDF

신체 자세의 변화가 하악의 안정위와 비틀림 회전운동에 미치는 영향 (Effect of Body Posture on the Rest Position and the Rotational Torque Movement of the Mandible)

  • 정승아;한경수;박미성;양근영
    • Journal of Oral Medicine and Pain
    • /
    • 제25권4호
    • /
    • pp.383-394
    • /
    • 2000
  • This study was performed to investigate the effect of change of body posture on the rest position and the rotational torque movement of the mandible. Thirty dental students without any signs and symptoms of temporomandibular disorders and with natural dentition were selected for this study. Cervical inclination and the amount of the mandibular movement on protrusion, on left and right excursion, and on tapping in three body postures such as sitting position, supine position without pillow, and supine position with pillow were measured by goniometer, Cervical-Range-of-$Motion^{(R)}$, and mandibular tracking device, $BioEGN^{(R)}$ with $Rotate!^{(R)}$ program. The data obtained were classified and processed according to body posture and type of lateral guidance with SPSS windows program and the results were as follows: 1. There was significant difference among the three cervical inclinations by body postures. 2. Comparison of mandibular rest positions among body postures showed significant difference only for lateral distance in frontal plane, but comparison between before and after swallowing showed significant difference except for the lateral distance, vice versa. 3. Distance and amount of the rotational torque movement on protrusion and/or lateral excursions didn't show any difference by body posture. But by both body posture and lateral guidance type, there were slightly significant difference for some items. 4. A significant difference was shown for the rotational torque movement in frontal plane on tapping by body postures, for the lateral distance in frontal plane on sitting position by lateral guidance type, and for the rotational torque movement in frontal plane by both body posture and lateral guidance type.

  • PDF

Breakage Detection of Small-Diameter Tap Using Vision System in High-Speed Tapping Machine with Open Architecture Controller

  • Lee, Don-Jin;Kim, Sun-Ho;Ahn, Jung-Hwan
    • Journal of Mechanical Science and Technology
    • /
    • 제18권7호
    • /
    • pp.1055-1061
    • /
    • 2004
  • In this research, a vision system for detecting breakages of small-diameter taps, which are rarely detected by the indirect in-process monitoring methods such as acoustic emission, cutting torque and motor current, was developed. Two HMI (Human Machine Interface) programs to embed the developed vision system into a Siemens open architecture controller, 840D, were developed. They are placed in sub-windows of the main window of the 840D and can be activated or deactivated either by a softkey on the operating panel or the M code in the NC part program. In the event that any type of tool breakage is detected, the HMI program issues a command for an automatic tool change or sends an alarm signal to the NC kernel. An evaluation test in a high-speed tapping machine showed that the developed vision system was successful in detecting breakages of small-diameter taps up to M1.

초소형나사의 CFRP 적층판 적용에 따른 체결특성에 관한 연구 (Study on Fastened Properties by Applied to CFRP Laminates of Subminiature Screw)

  • 최병희;김호중;김지훈
    • 대한기계학회논문집A
    • /
    • 제38권11호
    • /
    • pp.1239-1243
    • /
    • 2014
  • 탄소섬유 강화플라스틱은 비강도, 비강성이 크고, 높은 감쇠 특성과 중량감소 측면에서 우수한 특성을 나타낸다. 그러나 탄소섬유 강화플라스틱은 재료의 적층각 또는 적층 순서에 따라 기계적 특성 차이가 크다. 또한 인장과 굽힘과 같은 하중을 받을 때 금속과 달리 파괴 예측이 어렵다. 본 연구에서는 최근 실생활에 밀접한 휴대용 스마트기기에 CFRP 적용을 위한 외부 충격에 정형화, 최적화 설계방식을 제시하고자 한다. CFRP 를 적층각도별 기계적 특성을 얻고자 인장실험을 하였고, 각 적층각도별 체결 특성을 얻고자 판에 탭 가공 후 토크 측정기를 이용하여 풀림 토크와 체결토크를 측정하였다. 위 두 실험에 비교 분석하여 최적의 조건을 찾고자 한다. 인장실험에서 적층각이 Woven 시편에서 강도와 강성 값이 가장 우수하였다. 또한 복합재료에서는 기지와 적층배열 때문에 풀림방지 코팅나사의 효과를 보기 힘들다. [$0_8/+45_2/-45_2/90_8$]s 에서 체결력이 가장 우수했으나, 인장응력이 상대적으로 낮았다. 핸드폰에 적용을 위해 인장 특성과 체결력을 모두 충족하는 최적의 시편은 Woven 이다.

The effect of undersizing and tapping on bone to implant contact and implant primary stability: A histomorphometric study on bovine ribs

  • Di Stefano, Danilo Alessio;Perrotti, Vittoria;Greco, Gian Battista;Cappucci, Claudia;Arosio, Paolo;Piattelli, Adriano;Iezzi, Giovanna
    • The Journal of Advanced Prosthodontics
    • /
    • 제10권3호
    • /
    • pp.227-235
    • /
    • 2018
  • PURPOSE. Implant site preparation may be adjusted to achieve the maximum possible primary stability. The aim of this investigation was to study the relation among bone-to-implant contact at insertion, bone density, and implant primary stability intra-operatively measured by a torque-measuring implant motor, when implant sites were undersized or tapped. MATERIALS AND METHODS. Undersized (n=14), standard (n=13), and tapped (n=13) implant sites were prepared on 9 segments of bovine ribs. After measuring bone density using the implant motor, 40 implants were placed, and their primary stability assessed by measuring the integral of the torque-depth insertion curve. Bovine ribs were then processed histologically, the bone-to-implant contact measured and statistically correlated to bone density and the integral. RESULTS. Bone-to-implant contact and the integral of the torque-depth curve were significantly greater for undersized sites than tapped sites. Moreover, a correlation between bone to implant contact, the integral and bone density was found under all preparation conditions. The slope of the bone-to-implant/density and integral/density lines was significantly greater for undersized sites, while those corresponding to standard prepared and tapped sites did not differ significantly. CONCLUSION. The integral of the torque-depth curve provided reliable information about bone-to-implant contact and primary implant stability even in tapped or undersized sites. The linear relations found among the parameters suggests a connection between extent and modality of undersizing and the corresponding increase of the integral and, consequently, of primary stability. These results might help the physician determine the extent of undersizing needed to achieve the proper implant primary stability, according to the planned loading protocol.

교점용 미니 임플랜트의 cutting flute의 길이 및 형태에 따른 식립 및 제거 토크의 비교 (Effect of cutting flute length and shape on insertion and removal torque of orthodontic mini-implants)

  • 윤순동;임성훈
    • 대한치과교정학회지
    • /
    • 제39권2호
    • /
    • pp.95-104
    • /
    • 2009
  • 본 연구는 self-tapping screw의 특징적 구조인 cutting flute의 길이 및 형태 변화에 따른 미니 임플랜트의 식립 및 제거 토크를 비교해보기 위해 시행되었다. 외경, 내경, 길이 및 pitch 등 다른 조건이 모두 동일하고 cutting flute의 형태만 다른 세 종류의 미니 임플랜트를 사용하였다(A군; 2.6 mm 길이의 flute가 형성된 그룹, B군; 3.9 mm의 길이이면서 직선형의 flute를 갖는 그룹, C군; 3.9 mm의 길이이면서 나선형의 flute를 갖는 그룹). 골밀도를 균일하게 하기 위해 실험용 인공골(Sawbones Inc., USA)을 사용하였으며, 수직력 및 회전속도를 일정하게 하기 위해 구동식 토크시험기를 이용하였다. 그 결과 다음과 같은 결론을 얻었다. 총 삽입 시간은 2 mm 두께의 피질골 시편에서는 세 군간에 차이를 보이지 않으나, 4 mm 두께의 피질골 시편에서는 C군 > B군 > A군 순으로 짧은 삽입 시간을 보였다. 최대 삽입 토크는 2 mm 두께의 시편에서는 A군이 다른 두 군에 비해 높은 값을 보이나, 4 mm 두께의 피질골 시편에서는 C군 > A군 > B군 순으로 높은 값을 보였다. 최대 제거 토크는 2 mm 두께의 피질골 시편에서는 세 군 사이에 차이가 없으나, 4 mm 두께의 피질골 시편에서는 C군이 다른 두 군에 비해 높은 값을 보여주었다. 이상의 결과로 보아 피질골이 두꺼운 부위에 미니 임플랜트를 식립할 경우 cutting flute의 길이 및 형태 또한 고려하여 미니 임플랜트를 선택하는 것이 바람직하다.

공구파손감지용 비젼시스템의 NC실장에 관한 연구 (A Study on the NC Embedding of Vision System for Tool Breakage Detection)

  • 이돈진;김선호;안중환
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2002년도 춘계학술대회 논문집
    • /
    • pp.369-372
    • /
    • 2002
  • In this research, a vision system for detecting tool breakage which is hardly detected by such indirect in-process measurement method as acoustic emission, cutting torque and motor current was developed and embedded into a PC-NC system. The vision system consists of CMOS image sensors, a slit beam laser generator and an image grabber board. Slit beam laser was emitted on the tool surface to separate the tool geometry well from the various obstacles surrounding the tool. An image of tool is captured through two steps of signal processing, that is, median filtering and thresholding and then the tool is estimated normal or broken by use of change of the centroid of the captured image. An air curtain made by the jetting high-pressure air in front of the lens was devised to prevent the vision system from being contaminated by scattered coolant, cutting chips in cutting process. To embed the vision system to a Siemens PC-NC controller 840D NC, an HMI(Human Machine Interface) program was developed under the Windows 95 operating system of MMC103. The developed HMI is placed in a sub window of the main window of 840D and this program can be activated or deactivated either by a soft key on the operating panel or M codes in the NC part program. As the tool breakage is detected, the HMI program emit a command for automatic tool change or send alarm to the NC kernel. Evaluation test in a high speed tapping center showed the developed system was successful in detection of the small-radius tool breakage.

  • PDF