• 제목/요약/키워드: Tapping Torque

검색결과 25건 처리시간 0.009초

고속탭핑에 있어서 절삭토크에 관한 연구 (A Study on Tapping Torque in High Speed Tapping)

  • 최만성
    • 대한기계학회논문집
    • /
    • 제18권12호
    • /
    • pp.3195-3201
    • /
    • 1994
  • In order to analytically predict tapping torque and thrust force in high speed tapping, a cutting model for main cutting edge with a uniformly restricted tool-chip contact area were developed. From this model equations are derived for the prediction of tapping torque given the cutting conditions, tap geometry, and an empirical factor which is related to the workmaterial. Computed values of torque is shown to compare favorably with those obtained from tapping tests on 16MnCr5. The applied torque about the cutting edge of teeth at lead chamfer is estimated respectively and it is shown that observed value is gradually decreased with following teeth.

고속태핑에 있어서 탭의 형상과 절삭토크의 특성 (On Tap Geometry and Characteristics of Torque in High Speed Tapping)

  • 최만성;송지복
    • 한국정밀공학회지
    • /
    • 제13권8호
    • /
    • pp.139-145
    • /
    • 1996
  • Tapping is one of the most widely used machining operations. There are several methodes of producing external screw threads, e.g. turning, milling with single or multiple cutter, rolling, and grinding, but the methods available for cutting enternal threads are less numerous, and for threads in small holes, tapping is employed almost exclusively. In this study, the tap with the various geometry has been developed in order to tap special workmaterial at considerably higher cutting speed than that of the conventional HSS tap. The experimental tests are run with various cutting speed by using a piezo type tool dynamometer to measure tapping torque. Tapping torque is affected by the design of the tap, which seems to be due to internal friction and shearing of the metal. It is clarified that the process of chip formation strongly depends on rake angle, relief angle, angle of twist.

  • PDF

마찰력을 고려한 고속탭핑 토크 모델링 (Modeling of High-speed Tapping Touque Considering Friction Force)

  • 이돈진;강지웅;전현배;김선호;안중환
    • 한국정밀공학회지
    • /
    • 제18권11호
    • /
    • pp.67-73
    • /
    • 2001
  • This paper aims at developing a torque model for the high-speed tapping with small-diameter taps. As recent industries such as automobile and information technology grows, taps smaller than 5mm in diameter are needed much more. In that occasion, the friction force between a tap surface and a workpiece plays much more important role in the tapping torque than in he larger tapping. Tapping mechanism was analysed based on the tap geometry. It has two steps : one is a forward cutting composed of the chamfered threading and full threading and the other is the backward cutting. The torque by the cutting force in the chamfered threading is calculated using the cutting area and the specific cutting force while the torque by the friction force, which is rather dominant than the cutting force both in the full threading and in the backward cutting, is calculated using the normal force on the threads and the friction coefficient. The experiment has shown that the results by the proposed torque model fit quite well with the acutal measurements within the error of 10%.

  • PDF

연질 골에서 두 종류의 테이퍼 형태 임플란트의 초기 안정성에 관한 실험실적 연구 (In Vitro Study on the Initial Stability of Two Tapered Dental Implant Systems in Poor Bone Quality)

  • 김덕래;김명주;권호범;이석형;임영준
    • 구강회복응용과학지
    • /
    • 제25권4호
    • /
    • pp.391-401
    • /
    • 2009
  • 임플란트의 성공은 식립 후의 초기 안정성 (Initial stability)의 결과가 중요한 영향을 준다. 이 연구의 목적은 연질 골에서 두 종류의 테이퍼 형태 임플란트가 임플란트의 디자인과 self-tapping blade의 유무에 따라서 초기 안정성에 주는 영향을 알아보는 것이다. Self-tapping blade를 가지고 있는 것과 가지고 있지 않은 두 종류의 테이퍼 형태 임플란트가 사용되었다. Solid Rigid Polyurethane Form으로 연질 골 상태인 D4 골 모형을 재현하였다. 임플란트 고정체를 식립하면서 초기 안정성 값을 기록하고, 식립 직후 implant stability quotient (ISQ)을 측정하여 Resonance frequency Analysis (RFA)를 평가하였다. 마지막으로 임플란트가 식립된 모형골을 만능 시험기에 부착하여 장축 방향으로의 pull-out force를 측정하였다. 초기 안정성 값과 최대 pull-out torque 값은 non self-tapping implants가 self-tapping group에 비하여 통계학적으로 유의하게 큰 평균값을 나타냈다 (P = 0.008). 공진 주파수 분석 결과인 ISQ 값은 거의 비슷한 평균값을 보였으면 통계학적으로 차이가 없었다. 각 임플란트 시스템에서 식립 토크와 pull-out 최대 토크 그리고 공진 주파수 간에는 상관관계를 나타내지 않았다. Non self-tapping 임플란트의 높은 식립 토크는 임상적으로 우수한 초기 안정성을 의미한다. 결론적으로 연질 골에서 self-tapping blade가 없는 임플란트가 있는 것 보다 더 우수한 초기 안정성을 보였다.

STS304의 태핑과 탭 형상에 관한 연구 (A Study on Tapping for STS304 and Tap Geometry)

  • 이정길;최만성
    • 한국정밀공학회지
    • /
    • 제17권11호
    • /
    • pp.55-62
    • /
    • 2000
  • The poor machinability material such as austenite stainless steel(STS304) is emphasized on the wide use of HSSE for the tapping operation. The difficulty can be entirely to tapping torque due to chip formation through the hole of tap. The object of this study is to investigate tap geometry affecting the tapping torque from a practical point of view. The study shows that the optima tapping torque is affected by the tap geometry and cutting condition for STS304.

  • PDF

고속 탭핑에서의 절삭 특성 해석 (Analysis of Cutting Characteristics in High Speed Tapping)

  • 강지웅;김용규;이돈진;김선호;김화영;안중환
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2000년도 추계학술대회 논문집
    • /
    • pp.243-246
    • /
    • 2000
  • Productivty of tapping has been increasing through the tcchnological advances in synchronization between spindle rotation and feed motion even in the high spindle speed. However, not much researches have been conducted about tapping process because its complicate cutting mechanism. In order ta investigate the characteristics of the tapping process, this paper concentrates on the analysis of curting torque behavior during one cycle of lapping. As one completc thread is performed through the whole chamfer ercuttlng, cutting torque increases highly in chamfer cutting, but smaothly in full thread cutting Functioning of the threads guide. Cutting torque in backward cutting is smaller than in Sorwerd cutting due to only friction farce in against between the tool and workpiece. And torque behavior of a periodic Sine ripple-mark was identified during one revolution of a tap.

  • PDF

고속 동기 탭핑에서의 절삭 특성에 관한 연구 (Study of Cutting Characteristics in High Speed Synchronized Tapping)

  • 정용수;이돈진;김선호;안중환
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2002년도 추계학술대회 논문집
    • /
    • pp.304-307
    • /
    • 2002
  • High speed machining was accomplished. through the technological advances which covers the whole field of mechanical industry. But tapping have many troubles because of its complicate cutting mechanism, for example. tool damage, chip elimination and synchronization between spindle rotation and feed motion. But High speed tapping is so important that it marches in step with the flow of the times and make improvement in the productivity. In this paper we analyze mechanism of high speed synchronized tapping with the signal of tapping torque and spindle speed obtained through the newly developed high speed tapping machine(NTT-30B). We made an experiment with this machine on condition of various speed from 1000rpm to 10000rpm. As one complete thread is performed through the whole chamfer cutting, cutting torque increases highly in chamfer cutting, but smoothly in full thread cutting functioning of the threads guide. And the size of cutting torque according to spindle speed(rpm) was not enough of a difference to be conspicuous.

  • PDF

초고속 태핑에서 동기오차가 태평특성과 나사품질에 미치는 영향 분석 (Investigation of Influences of Synchronizing Errors on the Tapping Characteristics and Thread Quality in the Ultra-High-Speed Tapping)

  • 이돈진;김선호;안중환
    • 한국정밀공학회지
    • /
    • 제20권9호
    • /
    • pp.40-46
    • /
    • 2003
  • Synchronizing errors between the spindle motor and the z-axis motor directly influences the cutting characteristics and the thread quality in tapping, because the tapping process is accomplished by synchronizing the movement of the z-axis with the revolutionary spindle motion. Generally synchronizing errors are decided by tile parameters of the servo system and commanded velocity. The excessive synchronizing errors which are induced by the parameter mismatch and high cutting velocity can cause tap breakage due to the abrupt increase of cutting torque or damage the thread accuracy by overcutting the already cut threads. In this paper, the influences of the synchronizing errors on the tapping characteristics in the ultra high-speed tapping will be described and a minimum level of synchronizing errors necessary to maintain the quality of the cut thread will be presented.

Rigid 탭핑에서의 Z축과 주축간 동기오차의 거동 (Action of Synchronous error between Z axis and spindle axis on rigid tapping)

  • 이돈진;강지웅;김용규;김선호;김화영;안중환
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2000년도 추계학술대회 논문집
    • /
    • pp.184-187
    • /
    • 2000
  • This paper describes action of synchronous error between z axis and spindle axis on rigid tapping. Because rigid tapping cuts the threads synchronizing the movement of z axis to spindle rotation, synchronous error between z axis and spindle is very important. Increase of synchronous error degrades the accuracy of thread and crushes the tap in worst case. So we developed the realtime measurement system of synchronous error in order to know the action of synchronous error on rigid tapping. In result, we have known that synchronous error was increased according to rise of spindle speed and z axis speed. And because the cutting torque(M3-30Ncm∼M10-300Ncm) on rigid tapping are less than maximum motor torque(3500Ncm), it specially doesn't affect the synchronous error. The most important parameter which has affected the increase of synchronous error was acceleration/deceleration time. On worst case, spindle motor was tripped because of the excess of synchronous error. Because the acceleration/deceleration time ocuupies the most of the total cutting time, in order to move on the high speed rigid tapping, the acceleration/deceleration time of spindle must be remarkably reduced.

  • PDF

Comparative Biomechanical Study of Self-tapping and Non Self-tapping Tapered Dental Implants in Artificially Simulated Quality 2 Bone

  • Baek, Yeon-Wha;Kim, Duck-Rae;Park, Ju-Hee;Lim, Young-Jun
    • Journal of Korean Dental Science
    • /
    • 제4권2호
    • /
    • pp.52-58
    • /
    • 2011
  • Purpose: Modifications of implant design have been related to improving initial stability. The purpose of this study was to investigate their respective effect on initial stability between two tapered implant systems (self-tapping vs. non-self-tapping) in medium density bone using three different analytic methods. Materials and Methods: Self-tapping implant (GS III$^{(R)}$; Osstem Implant Co., Busan, Korea) and non-self-tapping implant (Replace Select$^{(R)}$; Nobel Biocare, G$\H{o}$teborg, Sweden) were investigated. In Solid rigid polyurethane blocks of artificially simulated Quality 2 bone, each of the 5 implants was inserted according to the manufacturer's instructions for medium-bone drilling protocol. Evaluation of initial stability was carried out by recording the maximum insertion torque (IT) and performing the resonance frequency analysis (RFA), and the pull-out test. Results: The IT and RFA values of self-tapping implant were significantly higher than those of non self-tapping implant (P=.009 and P=.047, respectively). In the pull-out values, no significant differences were found in implants between two groups (P=.117). Within each implant system, no statistically significant correlation was found among three different outcome variables. Conclusions: These findings suggest that design characteristics of implant geometry significantly influence the initial stability in medium bone density.