• 제목/요약/키워드: Tapered

검색결과 905건 처리시간 0.022초

PVD증착용 흡착인히비터의 영향에 따른 제작막의 특성 비교 (Characteristics Comparison of Prepared Films According to Influence of Adsorption Inhibitor in the Condition of Deposition)

  • 이찬식;윤용섭;권식철;김기준;이명훈
    • 한국표면공학회:학술대회논문집
    • /
    • 한국표면공학회 2001년도 추계학술발표회 초록집
    • /
    • pp.67-67
    • /
    • 2001
  • The structure zone model has been used to provide an overview of the relationship between the microstructure of the films deposited by PVD and the most prominent deposition condition.s. B.AMovchan and AV.Demchishin have proposed it firstls such model. They concluded that the general features of the resulting structures could be correlated into three zones depending on $T/T_m$. Here T m is the melting point of the coating material and T is the substrate temperature in kelvines. Zone 1 ($T/Tm_) is dominated by tapered macrograins with domed tops, zone 2 ($O.3) by columnar grains with denser boundaries and zone 3 ($T/T_m>O.5$) by equiaxed grains formed by recrystallization. J.AThomton has extended this model to include the effect of the sputtering gas pressure and found a fourth zone termed zone T(transition zone) consisting of a dense array of poorly defined fibrous grains. R.Messier found that the zone I-T boundary (fourth zone of Thorton) varies in a fashion similar to the film bias potential as a function of gas pressure. However, there has not nearly enough model for explaining the change in morphology with crystal orientation of the films. The structure zone model only provide an information about the morphology of the deposited film. In general, the nucleation and growth mechanism for granular and fine structure of the deposited films are very complex in an PVD technique because the morphology and orientation depend not only on the substrate temperature but also on the energy of deposition of the atoms or ions, the kinetic mechanism between metal atoms and argon or nitrogen gas, and even on the presence of impurities. In order to clarify these relationship, AI and Mg thin films were prepared on SPCC steel substrates by PVD techniques. The influence of gas pressures and bias voltages on their crystal orientation and morphology of the prepared films were investigated by SEM and XRD, respectively. And the effect of crystal orientation and morphology of the prepared films on corrosion resistance was estimated by measuring polarization curves in 3% NaCI solution.

  • PDF

동안신경마비가 동반된 거대세포 동맥염 환자의 치료 경험 - 증례보고 - (A Case Report of Giant Cell Arteritis Combined with Oculomotor Nerve Palsy)

  • 류영빈;한경림;김찬
    • The Korean Journal of Pain
    • /
    • 제20권2호
    • /
    • pp.255-257
    • /
    • 2007
  • Giant cell arteritis, which is also referred to as temporal arteritis, is defined as a systemic vasculitis in individuals over 50 years of age. Here, we report a case of giant cell arteritis combined with oculomotor nerve palsy. An 81-year old female patient experienced a headache for 10 days in her left temporoparietal area, that was characterized by a continuous dull ache and heaviness with intermittent shooting and lancinating pain. Her symptoms persisted in spite of receiving strong analgesics in another hospital. Upon physical examination, she was found to have marked tenderness over the left temporal area, especially along the path of the temporal artery as well as limitation of adduction, supraduction and infraduction of the left eyeball. At the time of admission, her erythrocyte sedimentation rate (ESR) and C-reactive protein (CRP) were 52 mm/hr and 3.94 mg/dl. In addition her brain MRI revealed no specific findings. Giant cell arteritis was suspected based on the clinical symptoms and signs as well as the elevated ESR and CRP. Oral steroid therapy started was started with an initial dose of 40 mg of prednisolone per day that was gradually tapered to 5 mg a day for 2 weeks. Her headache subsided one day after the steroid therapy and oculomotor nerve palsy was markedly improved after 2 weeks of the therapy. After 2 months she had recovered completely from her symptoms.

치질에 대한 상아질 접착제의 접합도에 관한 연구 (A STUDY ON THE ADAPTATION OF DENTIN BONDING AGENTS TO TOOTH STRUCTURE)

  • 박성택;조영곤;황호길
    • Restorative Dentistry and Endodontics
    • /
    • 제20권2호
    • /
    • pp.732-743
    • /
    • 1995
  • The purpose of this study was to evaluate the adaptation of light cured dentin bonding agents to tooth structure by measuring contraction gaps on interfaces between cavity wall and composite resin under SEM study. In this study, class V cavities with cementum margin were prepared on the buccal surfaces of 15 extracted human premolar teeth and teeth were randomly assigned 3 groups of 5 teeth each. The cavities were filled with three dentin bonding agents and two composite resins were investigated for this study: three dentin bonding agents; Scotchbond 2, Scotchbond Multi-Purpose. All-Bond 2, two composite resins; Silux Pius, Z-100. Group 1 : Scotchbond 2 + Silux Plus Group 2 : Scotchbond Multi~Purpose + Z-100 Group 3 : All-Bond 2 + Z-100 The restored teeth were stored in 100% relative humidity at $37^{\circ}C$ for 7 days. And then, the roots of the teeth were removed with the tapered fissure bur and the remaining crowns were sectioned occlusogingivally through the center of restorations. Adaptation at tooth-restoration interface was assesed occlusally, gingivally, and axially by scanning electron microscope. The results were as follows : 1. In Group 1, the adaptation to dentinal wall of Scotchbond 2 was poor, but the adaptation to enamel wall of Scotchbond 2 was excellent. 2. In Group 2, the adaptation to occlusal was axial wall and gingival wall of Scotchbond Multi-Purpose was excellent. Especially in axially wall, the dentin bonding agents infiltrated into dentinal tubules and there was excellent adaptation to dentinal wall. 3. In Group 3, the adaptation to occlusal wall and axial wall of All-Bond 2 was excellent. But in gingival wall, there was gap formation between composite resin and dentin bonding agent.

  • PDF

광섬유 용융인장 방법에 의한 DWDM용 광다중화기의 제작 (Design and Fabrication of DWDM Multiplexer Using Optical Fiber Biconical Tapered Couplers)

  • 장진현;김명생;강덕근
    • 정보통신설비학회논문지
    • /
    • 제3권2호
    • /
    • pp.51-60
    • /
    • 2004
  • A광섬유 용융인장방법에 의해서 100GHz 채널간격을 갖는 DWDM용 8채널 광다중화기를 제작하였다. 8채널 광다중화기는 전광섬유형 Mach Zehnder 간섭계(MZI)를 3단으로 다단 연결하여 제작되었으며, 광다중화기 채널별 출력파장의 삽입손실을 균일하게 하기 위하여 파장에 대한 삽입손실변화가 적은 파장무의존형 커플러(WFC)를 이용하여 전광섬유형 MZI를 제작하였다. 광다중화기를 구성하는 광섬유형 MZI를 제작함에 있어서 경로차에 따른 출력 파장간격의 변화를 시뮬레이션을 통하여 알아보았고 다단연결에 의한 광다중화기 구현방법을 논의하였다. 전용 제작 장치를 이용하여, 전광섬유형 MZI를 제작하였으며, 미세한 파장을 저절하기 위해서, $CO_2$ 레이저를 이용하였다. 제작된 8채널 광다중화기는 평균 삽입 손실 2.1dB, 5.5dB에서의 통과대역폭이 0.8nm 이며, 25dB의 채널 Crosstalk를 갖는 특성을 얻을 수 있었고, 편광의존손실은 0.06dB 였다.

  • PDF

모형레진 근관에서 엔진 구동용 니켈-타이타늄 파일의 경사도의 차이에 따른 근관성형력의 비교 (COMPARISON OF SHAPING ABILITY OF NICKEL-TITANIUM ROTARY FILES WITH DIFFERENT TAPER IN SIMULATED RESIN CANALS)

  • 금기연;임경란;정일영;이승종;이찬영
    • Restorative Dentistry and Endodontics
    • /
    • 제25권1호
    • /
    • pp.78-84
    • /
    • 2000
  • The aim of this study was to compare shaping ability of nickel-titanium rotary files with different taper in simulated resin canals. The instruments used in this study were GT with .04 taper ProFile with ISO-sized tip, .04 taper ProFile with ISO-sized tip alone, and .02 taper Naviflex file and all canals were prepared by crown-down technique. A total of 30 composite images were made from pre- and post-canal scanned images using Scanjet 4C scanner and Corel photopaint 8.0 and then, prevalence of canal aberrations was measured. The amount of coronal substance the instruments removed was also calculated two-dimensionally on digitized images with the Brain C software to compare the relative enlarging efficiency. Finally, the prepared internal canal form was evaluated three-dimensionally with impression technique. The results were as follows; 1. The incidence of zipping in Naviflex group was significantly high compared to the other two groups(P<.05). 2. The amount of coronal substance the GT combined group removed was significantly larger than the other two groups(P<.05). 3. The GT combined group produced canals with good taper and flow. Under the conditionas of this study, the combined use of larger tapered nickel-titanium rotary files prepared simulated canals safely, efficiently and with good three-dimensional form.

  • PDF

2급 와동 복합레진 인레이 충전 후 변연누출에 관한 연구 (A STUDY ON THE MARGINAL LEAKAGE OF CLASS II COMPOSITE RESIN INLAY)

  • 강현숙;최호영
    • Restorative Dentistry and Endodontics
    • /
    • 제17권1호
    • /
    • pp.191-205
    • /
    • 1992
  • The purpose of this study was to evaluate the microleakage of class II composite resin inlays and compare them with the conventional light-cured resin filling restorations. Class II cavities were prepared in 60 extracted human molars with which cervical margins were located below 1.0mm at the cemento-enamel junction using No. 701 tapered fissure carbide bur. All of the prepared cavities were restored as follows and divided into 6 groups. Group I and 2 were restored using direct filling technique and group 3,4,5 and 6 were restored using direct inlay technique that was cemented with dual-cured resin cements. group I: Cavities were restored with light-curing composite resin, Brilliant Lux. group 2. Cavities were restored with light-curing composite resin, Clearfil PhotoPosterior. group 3: Cavities were restored with Clearfil CR Inlay and heat treated at $125^{\circ}C$ for 7 minutes. group 4: Cavities were restored with same material as group 3 and heat treated at $100^{\circ}C$ for 15 minutes. group 5: Cavities were restored with Brilliant (Indirect esthetic system) and heat treated at $125^{\circ}C$ for 7 minutes. group 6: Cavities were restored with same material as group 5 and heat treated at $100^{\circ}C$ for 15 minutes. All specimens were polished with same method and thermocycled between $6^{\circ}C$ and $60^{\circ}C$, then immersed in a bath of 2.0% aqueous solution of basic fuchsin dye for 24 hours. Dyed specimens were sectioned longitudinally and dye penetration degree was read on a scale of 0 to 4 by Tani and Buonocore's method 45). The results were as follows: 1. Microleakage was observed rather at the cervical margins than at the occlusal margins in all groups. 2. Composite resin inlay groups showed significantly less leakage than direct filling groups at the cervical margins (p < 0.001). 3. In composite resin inlay groups, there was no significant difference in microleakage between specimens by heat treating temperature and time (p > 0.05). 4. There was no significant difference in leakage between each groups at the occlusal margins (p > 0.05).

  • PDF

Physiological and Morphological Aspects of Bipolaris sorokiniana Conidia Surviving on Wheat Straw

  • Duveiller, E.;Chand, R.;Singh, H.V.;Joshi, A.K.
    • The Plant Pathology Journal
    • /
    • 제18권6호
    • /
    • pp.328-332
    • /
    • 2002
  • Wheat samples showing typical spot blotch symptoms on stems and sheaths were collected from the field after physiological maturity, and were sealed in paper bags and stored in the laboratory at room temperature to study the survival of Bipolaris sorokiniana conidia on wheat straw. The materials were observed at monthly intervals to assess the conidia viability during storage. After 4 months, the frequency of individual conidia already present on wheat straw at the time of sampling was reduced and appeared to be progressively replaced by the formation of round structures consist-ing of conidia aggregates. After 5 months, distinct, individual conidia were no longer detected, and only 'clumps of conidia' were observed. These dark black aggregates or 'clumps of conidia’measured 157-170$\mu\textrm{m}$ in diameter and were grouped into boat-shaped olivacious conidia showing thick wall and measuring 50-82$\times$20-30$\mu\textrm{m}$. The germination was unipolar and below 0.5%, suggesting the occurrence of dormancy, In contrast, individual conidium produced on wheat during the growing season were 96-130$\times$16-20$\mu\textrm{m}$, slightly curved, hyaline to light pale, and euseptate with a bipolar germination reaching 98-100%. Bipolaris sorokiniana conidia produced on PDA were 55-82$\times$20-27$\mu\textrm{m}$, tapered at both ends, dark brown to olivacious, distoseptate, showed up to 1% germination, and were predominantly unipolar. Results of the present study suggest that B. sorokiniana conidia belonged to two different physiological categories corresponding to the pathogen's infection phase and its survival, respectively. The infection phase is characterized by a high germination percentage as opposed to the survival phase harboring apparent dormancy.

광중합형 글래스 아이오노머 시멘트의 치질접착에 관한 연구 (THE ADAPTATION OF LIGHT CURED GLASS IONOMER CEMENTS TO TOOTH STRUCTURE)

  • 허승면;조영곤;문주훈
    • Restorative Dentistry and Endodontics
    • /
    • 제21권2호
    • /
    • pp.489-504
    • /
    • 1996
  • The purpose of this study was to compare the adaptation to the tooth structure of five light cured glass ionomer cements (Fuji II LC. VariGlass VLC, Vitremer, Dyract and Geristore). Human, non-carious fifty extracted permanent premolars stored in normal saline were used. Class V cavity preparations were created on the buccal surfaces. The occlusal margin of each cavity was placed on the enamel and the gingival margin was placed on the cementum/dentin. The teeth were then distributed at random into five groups of 10 teeth each. Group 1: Fuji II LC, Group 2 : VariGlass VLC, Group 3 : Vitremer, Group 4: Dyract, Group 5 : Geristore. The prepared cavities were restored with one of the five light cured glass ionomer cements. The manipulation of each material was handled according to the manufacturer's instructions. All samples were placed in incubator of 100% relative humidity at $37^{\circ}C$ for 24 hours. The roots of the teeth were removed with the tapered fissure bur and the remaining crowns were sectioned buccolingually through the center of restorations. The cut interfaces were gradually hand polished on sandpapers from 300 up to 1200 grit. The adaptation at the tooth/cements interface was assessed by SEM (JSM-840A, JEOL Ltd.). The results of this study were as follows : 1. Group 2 revealed the best adaptation and groups 1, 4 and 5 revealed similar adaptation pattern to the cavity walls. Group 3 revealed the worst adaptation to the cavity walls. 2. Enamel margins showed better adaptation than dentin/cementum margins with each material except group 3. 3. The hybrid layers were observed between the glass ionomer cement and dentin in groups 2, 4 and 5.

  • PDF

Effect of ultrasonic tip designs on intraradicular post removal

  • Aguiar, Anny Carine Barros;de Meireles, Daniely Amorim;Marques, Andre Augusto Franco;Sponchiado, Emilio Carlos Junior;Garrido, Angela Delfina Bitencourt;Garcia, Lucas Da Fonseca Roberti
    • Restorative Dentistry and Endodontics
    • /
    • 제39권4호
    • /
    • pp.265-269
    • /
    • 2014
  • Objectives: To evaluate the effect of different ultrasonic tip designs on intraradicular post removal. Materials and Methods: The crowns of forty human canine teeth were removed, and after biomechanical preparation and filling, the roots were embedded in acrylic resin blocks. The post spaces were made, and root canal molding was performed with self-cured acrylic resin. After casting (Cu-Al), the posts were cemented with zinc phosphate cement. The specimens were randomly separated into 4 groups (n = 10), as follows: G1 - no ultrasonic vibration (control); G2 - ultrasonic vibration using an elongated cylindrical-shaped and active rounded tip; G3 - ultrasonic vibration with a flattened convex and linear active tip; G4 - ultrasonic vibration with active semicircular tapered tip. Ultrasonic vibration was applied for 15 seconds on each post surface and tensile test was performed in a Universal Testing Machine (Instron 4444 - 1 mm/min). Results: G4 presented the highest mean values, however, with no statistically significant difference in comparison to G3 (p > 0.05). G2 presented the lowest mean values with statistically significant difference to G3 and G4 (p < 0.05). Conclusions: Ultrasonic vibration with elongated cylindrical-shaped and active rounded tip was most effective in reducing force required for intraradicular post removal.

파이로작동기구 성능평가를 위한 해석모델 연구 (A Study on Analytical Approach for Performance Evaluation of Pyrotechnically Actuated Device)

  • 최주호;성홍계;김준식
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2012년도 제38회 춘계학술대회논문집
    • /
    • pp.63-64
    • /
    • 2012
  • 파이로 작동기구(PAD)는 고에너지 재료를 원격으로 폭발시켜 기구를 작동시키는 부품으로서 지금까지 이에 대한 설계는 주로 경험에 의해 이뤄졌다. 본 연구에서는 PAD의 작동 메커니즘을 해석적으로 모델링하는 효과적 방법을 개발하고 이를 설계에 활용하고자 한다. 해석모델은 서로 다른 해석특성을 가지는 세가지 순차적 스텝으로 구성되며 이들을 연계하여 통합 해석을 수행한다. 첫째 스텝은 작동기에서의 폭발 및 이로 인한 생성된 압력거동 해석, 둘째는 이러한 압력에 의해 피스톤을 작은 구멍 속으로 밀어넣는 압착거동 해석, 셋째는 피스톤 끝단에 있는 커터에 의해 박막을 관통하는 해석이며, 이로 인해 최종적으로 박막이 절개되면서 소기의 임무를 완성하게 된다. 본 발표에서는 이에 대한 개략적 소개와 일부 진행된 선행연구 결과를 소개한다.

  • PDF