• Title/Summary/Keyword: Tapered

Search Result 909, Processing Time 0.036 seconds

ANALYSIS OF THE CLINICAL SYMPTOMS AND THE TEMPOROMANDIBULAR JOINT DISK BY MAGNETIC RESONANCE IMAGING AFTER CONSERVATIVE TREATMENT WITH ANTERIOR REPOSITIONING SPLINT (측두하악관절 환자의 전방재위치장치 치료 전후의 임상증상 및 자기공명영상을 이용한 관절원판 변화의 분석)

  • Myoung, Shin-Won;Park, Je-Uk
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.28 no.2
    • /
    • pp.136-142
    • /
    • 2006
  • Temporomandibular joint(TMJ) disorders have characteristic clinical findings such as pain, joint sound, and abnormal jaw function. With the rapid progress in TMJ imaging techniques, magnetic resonance imaging(MRI) especially provides the clinician and researcher with the ability to evaluate TMJ disorders(effusion, anterior disk displacement) and the hard and soft tissue of the TMJ. In order to manage the internal derangement of TMJ such as anterior disk displacement, the so-called appliance therapy is commonly used. This technique became the treatment of choice before surgical intervention by many practitioners. The purpose of the present study was to evaluate and determine the efficacy of anterior repositioning splint by means of the change of the position of the disk through pre- and post-treatment MRI. MRI and clinical symptom were carefully recorded in TMJ disorder patients. The relationship between TMJ symptoms such as pain, clicking sound, and disk displacement and effusion in MRI were analyzed. Then, splint therapy was applied for 3 months according to our protocol; at day 1, patients should wear 24 hours, in order to accomodate the splint and then, wearing time is reduced to 12 hours per day for one month. During next 2 months, it is tapered to 8 hours per day according to the evaluation of the clinical symptoms. Post-treatment MRI was obtained after 3 month protocol. This treatment strategy improved the clinical symptoms of TMJ disorder, and effusion and articular disk position showed a significant change. In conclusion, a treatment modality using an anterior repositioning splint therapy is an appropriate method for temporomandibular disorder patients.

Comparison of arch form between ethnic Malays and Malaysian Aborigines in Peninsular Malaysia

  • Othman, Siti Adibah;Xinwei, Eunice Soh;Lim, Sheh Yinn;Jamaludin, Marhazlinda;Mohamed, Nor Himazian;Yusof, Zamros Yuzaidi Moh;Shoaib, Lily Azura;Hussein, Nik Noriah Nik
    • The korean journal of orthodontics
    • /
    • v.42 no.1
    • /
    • pp.47-54
    • /
    • 2012
  • Objective: To determine and compare the frequency distribution of various arch shapes in ethnic Malays and Malaysian Aborigines in Peninsular Malaysia and to investigate the morphological differences of arch form between these two ethnic groups. Methods: We examined 120 ethnic Malay study models (60 maxillary, 60 mandibular) and 129 Malaysian Aboriginal study models (66 maxillary, 63 mandibular). We marked 18 buccal tips and incisor line angles on each model, and digitized them using 2-dimensional coordinate system. Dental arches were classified as square, ovoid, or tapered by printing the scanned images and superimposing Orthoform arch templates on them. Results: The most common maxillary arch shape in both ethnic groups was ovoid, as was the most common mandibular arch shape among ethnic Malay females. The rarest arch shape was square. Chi-square tests, indicated that only the distribution of the mandibular arch shape was significantly different between groups (p = 0.040). However, when compared using independent t-tests, there was no difference in the mean value of arch width between groups. Arch shape distribution was not different between genders of either ethnic group, except for the mandibular arch of ethnic Malays. Conclusions: Ethnic Malays and Malaysian Aborigines have similar dental arch dimensions and shapes.

New virtual orthodontic treatment system for indirect bonding using the stereolithographic technique

  • Son, Kyoung-Hoi;Park, Jae-Woo;Lee, Dong-Keun;Kim, Ki-Dal;Baek, Seung-Hak
    • The korean journal of orthodontics
    • /
    • v.41 no.2
    • /
    • pp.138-146
    • /
    • 2011
  • The purpose of this article is to introduce a new virtual orthodontic treatment (VOT) system, which can be used to construct three-dimensional (3D) virtual models, establish a 3D virtual setup, enable the placement of the virtual brackets at the predetermined position, and fabricate the transfer jig with a customized bracket base for indirect bonding (IDB) using the stereolithographic technique. A 26-year-old woman presented with anterior openbite, crowding in the upper and lower arches, and narrow and tapered upper arch, despite having an acceptable profile and balanced facial proportion. The treatment plan was rapid palatal expansion (RPE) without extraction. After 10 days of RPE, sufficient space was obtained for decrowding. After a 10-week retention period, accurate pretreatment plaster models were obtained using silicone rubber impression. IDB was performed according to the protocol of the VOT system. Crowding of the upper and lower arches was effectively resolved, and anterior openbite was corrected to normal overbite. Superimposition of the 3D virtual setup models (3D-VSM) and post-treatment 3D virtual models showed that the latter deviated only slightly from the former. Thus, the use of the VOT system helped obtain an acceptable outcome in this case of mild crowding treated without extraction. More cases should be treated using this system, and the pre- and post-treatment virtual models should be compared to obtain feedback regarding the procedure; this will support doctors and dental laboratory technicians during the learning curve.

A STUDY ON THE FATIGUE AND PHYSICAL PROPERTIES OF TITANIUM USED IN REMOVABLE PARTIAL DENTURES (국소의치용 티나늄의 피로도 및 물리적 성질에 관한 연구)

  • Kim Hak-Sun;Kim Kwang-Nam;Chang Ik-Tae
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.32 no.2
    • /
    • pp.249-267
    • /
    • 1994
  • The purpose of this study was to compare the fatigue, physical properties, flexibility and surface roughness of titanium used in removable partial dentures with those of a type IV and alloy and a cobalt- chromium alloy. Fatigue testing subjected the test specimen to rapid cycling at a given stress until failure occurred by using a small-sized, electrodynamic type bending fatigue testing machine. The S-N curves for the framework materials were generated. For tensile testing, a tensile bar as described in the ADA Specification No.14 was subjected to tensile loading until failure occurred. Load-displacement curves were generated for 18 gauge round specimen and tapered half round specimen. Then the flexibilities were calculated. The surface roughnesses were compared by analyzer. Through analyses of the data, the following conclusions were obtained. 1. The fatigue property of titanium was higher than that of a type IV gold alloy$(p\leq0.05)$, but there was no significant difference between titanium and a cobalt-chromium alloy $(p\geq0.05)$. 2. The yield strength, the ultimate tensile strength and Victors hardness of titanium were higher than those of a type IV gold alloy but lower than those of a coalt-chromium alloy$(p\leq0.05)$. 3. The percentage of elongation and reduction of area of titanium were the highest $(p\leq0.05)$. 4. The surface roughness of titanium was the greatest$(p\leq0.05)$. 5. The flexibility of titanium was lower than that of a type IV gold alloy but higher than that of a cobalt-chromium alloy$(p\leq0.05)$.

  • PDF

Improving Wave Propagation Performance of an Ultrasonic Waveguide for Heat Isolation (열 차단용 초음파 도파관의 전파성능 향상 연구)

  • 최인석;전한용;김인수;김진오
    • The Journal of the Acoustical Society of Korea
    • /
    • v.22 no.7
    • /
    • pp.545-553
    • /
    • 2003
  • This paper is concerned with protecting piezoelectric transducers used in an ultrasonic flowmeter from the high temperature of hot fluid in a pipe by using a waveguide and with improving the propagation of ultrasonic longitudinal vibration in the waveguide. Waveguide material has been chosen for efficient insulation of heat transferred in the waveguide, and the minimum length of the waveguide for protecting piezoelectric transducer has been estimated. Forced response of the longitudinal vibration in a uniform circular rod has been obtained and the length of the waveguide has been selected for maximum amplitude. Longitudinal vibration response of a conically-tapered rod excited at a natural frequency has been obtained to confirm that wave motion is amplified as the cross-sectional size of the waveguide decreases along the axial direction. The fact that dispersion of a pulse wave in a waveguide is reduced as the cross-sectional radius is decreased has been examined theoretically and confirmed experimentally by using a single-rod waveguide. A bundle-type waveguide has proven to be a practical one through the evaluation of the wave propagation performance.

Studies on the millimeter-wave Passive Imaging System II (밀리미터파 수동 이미징 시스템 연구 II)

  • Jung, Min-Kyoo;Chae, Yeon-Sik;Kim, Soon-Koo;Yoo, Jin-Seob;Koji, Mizuno;Rhee, Jin-Koo
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.44 no.3 s.357
    • /
    • pp.105-110
    • /
    • 2007
  • We have built the millimeter-wave passive imaging system with a lens and mechanical scan antenna. The lens was designed based on optical theory in order to focus millimeter-wane. A full image was taken from image points scanned by Placing antenna at the representative focal plane selectively. An integrated antenna array device for low-loss and low-noise with the array of 4 by 1, where components such as antenna, balun, MMIC, and detector were assembled on a sin91e substrate, and a fermi tapered slot antenna with high-gain and low-side lobe were used for elements of this millimeter-wave passive imaging system. Two dimensional antenna arrangement on focal plane was achieved in this imaging system.

Studies on the millimeter-wave Passive Imaging System III (밀리미터파 수동 이미정 시스템 연구 III)

  • Jung, Min-Kyoo;Chae, Yeon-Sik;Kim, Soon-Koo;Yoo, Jin-Seob;Koji, Mizuno;Rhee, Jin-Koo
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.44 no.3 s.357
    • /
    • pp.111-116
    • /
    • 2007
  • We have developed a passive millimeter wave (PMMW) imaging system with two-dimensional imaging arrays. For the imaging system we achieved single-substrate imaging-array element which include all necessary component such as Fermi tapered slot antenna (TSA), a balun, LNA's and a detector circuit on it. Two-dimensional arrays for real-time imaging at the 35 GHz band are currently under development. We will be able to make an advanced PMMW image system based on our system with the $2\times2$ imaging array in the near future.

Rigorous Design of Optical Directional Filters using MTLT (MTLT를 이용한 광 방향성 필터의 설계)

  • Park, Jai-Seo;Hong, Kwon-Eui;Ho, Kwang-Chun
    • Journal of IKEEE
    • /
    • v.5 no.2 s.9
    • /
    • pp.128-135
    • /
    • 2001
  • Optical wavelength filters based on directional couplers are rigorously designed and analyzed by Modal Transmission-Line Theory (MTLT). The conventional parallel directional coupler is utilized to implement a narrow-band filter, and it takes up the coupler with tapered structure as a wide-band filter. The power transfers of TE/TM modes in narrow-band filters are maximized at ${\lambda}=1.303{\mu}m\;and\;1.1496{\mu}m$, and the optical bandwidths are then 30nm and 10nm, respectively. Furthermore, when the coupling lengths of TE/TM modes in wide-band filters operating at ${\lambda}=1.55{\mu}m$ are selected as $183{\mu}m\;and\;178{\mu}m$, those are operated as the stop-band and pass-band filters, respectively.

  • PDF

Ultrastructure of Egg Micropyles and Zona Radiata in Three Aquacultural Teleosts (양식산 경골어류 3종의 난문과 방사대의 미세구조)

  • Yoon, Jong-Man
    • Korean Journal of Ichthyology
    • /
    • v.11 no.2
    • /
    • pp.126-133
    • /
    • 1999
  • Ultrastructure of the zona radiata and the micropyle of ripe eggs in the rainbow trout (Oncorhynchus mykiss), catfish (Silurus asotus) and loach (Misgurnus anguillicaudatus) were examined by light, scanning and transmission microscopes. The egg micropyle of rainbow trout and catfish consists of a funnel-shaped vestibule and a tapered canal transversing the zona radiata. The micropyle of rainbow trout and catfish showed the similar structure with flat pit and long canal. The micropylar wall showed the clockwise spiral structure in rainbow trout. The micropyle of the loach showed the type with a hollow pit leading into a short canal and the micropylar wall showed the counterclockwise spiral structure. There are numerous and various size pores at the surface area around the opening in every experimented fish. Interconnecting ridges were observed in the unfertilized eggs of every fish.

  • PDF

Influence of the connection design and titanium grades of the implant complex on resistance under static loading

  • Park, Su-Jung;Lee, Suk-Won;Leesungbok, Richard;Ahn, Su-Jin
    • The Journal of Advanced Prosthodontics
    • /
    • v.8 no.5
    • /
    • pp.388-395
    • /
    • 2016
  • PURPOSE. The purpose of this study was to evaluate the resistance to deformation under static overloading by measuring yield and fracture strength, and to analyze the failure characteristics of implant assemblies made of different titanium grades and connections. MATERIALS AND METHODS. Six groups of implant assemblies were fabricated according to ISO 14801 (n=10). These consisted of the combinations of 3 platform connections (external, internal, and morse tapered) and 2 materials (titanium grade 2 and titanium grade 4). Yield strength and fracture strength were evaluated with a computer-controlled Universal Testing Machine, and failed implant assemblies were classified and analyzed by optical microscopy. The data were analyzed using the One-way analysis of variance (ANOVA) and Student's t-test with the level of significance at P=.05. RESULTS. The group $IT4_S$ had the significantly highest values and group IT2 the lowest, for both yield strength and fracture strength. Groups $IT4_N$ and ET4 had similar yield and fracture strengths despite having different connection designs. Group MT2 and group IT2 had significant differences in yield and fracture strength although they were made by the same material as titanium grade 2. The implant system of the similar fixture-abutment interfaces and the same materials showed the similar characteristics of deformation. CONCLUSION. A longer internal connection and titanium grade 4 of the implant system is advantageous for static overloading condition. However, it is not only the connection design that affects the stability. The strength of the titanium grade as material is also important since it affects the implant stability. When using the implant system made of titanium grade 2, a larger diameter fixture should be selected in order to provide enough strength to withstand overloading.