• 제목/요약/키워드: Tap-Water Hydraulic System

검색결과 6건 처리시간 0.016초

수압 특성 연구를 기초로 한 수압시스템의 설계에 관한 연구 (A Study on the Design of water Hydraulic Systems Based on Characteristics of Tap-Water)

  • 윤영원;남윤주;박명관
    • 대한기계학회논문집B
    • /
    • 제28권11호
    • /
    • pp.1322-1331
    • /
    • 2004
  • This paper presents studies on the design of water hydraulic system and components to replace oil with tap-water as the pressure transmission medium in hydraulic systems. In order to improve the performance of water hydraulic system, the thermal and hydraulic properties of tap-water are first investigated. Based on these characteristics, the design parameters, such as the clearances of the moving parts, the cross-sectional area of pipes and relative roughness, are proposed so that the performance of water hydraulic system is the same as that of oil. In addition, the operating ranges, which show the possibility of using water hydraulic system, are examined.

수돗물 수질개선을 위한 배수관망시스템 관리 정책 - 수질모니터링을 중심으로 - (Monitoring of Distribution System to Improve Tap Water Quality)

  • 전제상;김자겸
    • 상하수도학회지
    • /
    • 제19권4호
    • /
    • pp.411-420
    • /
    • 2005
  • Maintaining a good quality of drinking water produced through appropriate water treatment processes to the tap is as important as improving water quality in a water treatment plant (WTP). The quality of most tap water, however, does not have the same quality as that of the water produced in a WTP due to the contamination in the distribution system while they are delivered through pipes and water tanks. It is very important to maintain water quality in distribution system to water suppliers for consumer's health and safety. Furthermore, it is not possible to investigate the water quality of all points in the distribution system because the system has a wide area and very complex hydraulic characteristics. One economic solution to prevent water quality in distribution system from being deteriorated is monitoring several points that might have the least water quality in the distribution system. If the quality of water of the monitoring points selected by proper ways is better than the quality index of Drinking Water Quality Guidelines suggested by Korean Ministry of Environment, all other points in the distribution system would be safe to drink.

음용수질의 안정성을 위한 부식지수제도의 도입 (Introduction of Corrosion Index System for Stability of Drinking Water Quality)

  • 김영관;김진근
    • 상하수도학회지
    • /
    • 제25권5호
    • /
    • pp.707-717
    • /
    • 2011
  • Replacement of old water distribution pipes for protecting water quality induced by pipe corrosion requires enormous budget. Even after the replacement, however, corrosion can occur again at any times and, therefore, inhibitive measure of the corrosion will be not only economical but needed to diminish the consumers' distrust on tap water quality. In 2008, National Environmental Research Institute did a survey on 8 major drinking water source and proposed to establish the Langelier Saturation Index(LI) as a corrosion index in Drinking Water Quality Criteria. Among the water industries of Korea, K-Water is the only one that set up the level of pH over 7.0 and LI above -1.5 on yearly average basis. However, no systematic regulation including LI to inhibit the corrosive tendency has been established yet. In this paper, LI values out of 31 drinking water treatment plants were analyzed and two-stage control of LI value as a measure of corrosive tendency of water is proposed. Primarily, water treatment facilities may operate the system at a target LI value below -1.5. Following the investigation on the effect caused by adjusting the LI value on water quality and corrosiveness, it will be desirable to improve LI value below -1.0 in the long run. In addition to the LI, supplemental use of Larson's modified ratio (LMR) which incorporates hydraulic detention time will be necessary. Several methods to prove the inhibitive effect of improving the LI value on water quality have been also suggested.

LAND FARMING OF WATER PLANT ALUM SLUDGE ON ACID MINERAL SOIL AFFECTED BY ACID WATER

  • Lee, Seung-Sin;Kim, Jae-Gon;Moon, Hi-Soo;Kang, Il-Mo
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2001년도 총회 및 춘계학술발표회
    • /
    • pp.182-186
    • /
    • 2001
  • An acid forest surface soil as a land farming medium was treated with a water plant alum sludge at 0 to 18%. Indian mustard was grown in the treated soil in a greenhouse for 5 weeks and watered with pH 4 tap water adjusted with a mixed acid (1HNO$_3$: 2H$_2$SO$_4$) during plant growth. Changes in soil property, leachate chemistry, plant growth, and plant uptake of elements by the sludge treatment were determined. The alum sludge treatment increased buffer capacity to acidity, hydraulic conductivity, water holding capacity, and phosphate adsorption of the soil and decreased bulk density and mobility of small particles. The sludge treatment reduced leaching of Al, Mg, K, Na, and root elongation. Plant did uptake less amount of the cations and P but more Ca with the sludge treatment.

  • PDF

도로노면 유출수 처리를 위한 여과에서의 여재별 손실수두 특성 (A study on the headloss of filter media for treatment of Road Runoff)

  • 최원석;송창수;김석구
    • 상하수도학회지
    • /
    • 제22권6호
    • /
    • pp.697-704
    • /
    • 2008
  • Stormwater runoff from urban road area as non-point source has a tendency of including lots of pollutants at initial rain period. Recently, there are several cases of having installed treatment facilities for reducing pollution discharge from the impervious cover in urban area to prevent watershed environment from getting worse. The filtration type among non-point source treatment systems has been known as one of the most efficient system for treatment of non-point source pollutants. Therefore, various kinds of filter media such as expanded polypropylene(EPP), granular activated carbon, zeolite, perlite, illite, sand, gravel has been developed. This study was conducted to verify performance and hydraulic characteristics of filter media as measures for non-point source. The experiment was carried out to evaluate applicability and variation of 4 kind of most popular filter media(EPP, GAC, Zeolite, Perlite) in headloss with elapsed time and influent flow rate and to obtain data base that could be used to establish management plan for road runoff treatment. In experiment by tap water, it showed that EPP and perlite those are floatable materials showed stable operating performance and lower headloss than the others.

계절별 수도사용량에 따른 적수 및 탁수발생 위험도 분석 (Risk analysis of red water and turbid water based on seasonal water usage)

  • 한진우;이상목;권혁재
    • 한국수자원학회논문집
    • /
    • 제56권7호
    • /
    • pp.451-460
    • /
    • 2023
  • 본 연구에서는 박리위험도와 퇴적위험도로 분류하여 적수와 탁수발생 위험도를 분석하였다. 먼저, 적수 및 탁수를 발생시키는 위험 인자들을 도출 하였고 계절별 수도사용량을 고려하여 수리해석을 진행하였다. 적용 지역은 청주시로 13개 동에 걸쳐서 위험도 분석을 진행하였고 퇴적위험도가 높은 지역과 박리위험도가 높은 지역을 선정할 수 있었다. 박리와 퇴적위험도가 모두 높다는 것은 수질문제를 일으킬 가능성이 매우 높은 지역으로 판단할 수 있다. 퇴적위험도와 박리위험도가 가장 높은 지역은 내덕1동과 율량동 구시가지로 경과년수는 30년 이상으로 청주시에서 가장 오래된 지역 이다. 퇴직위험도와 박리위험도 분석을 통해 상수관망의 유지관리 기능을 강화하여 시민들에게 안전한 물 공급을 통해 수돗물에 대한 신뢰도를 높일 수 있을 것이다.