• Title/Summary/Keyword: Tank

Search Result 5,506, Processing Time 0.037 seconds

Development of Tank Simulation Model (전차 시뮬레이션 모델 개발)

  • 최상영;김의환
    • Journal of the military operations research society of Korea
    • /
    • v.28 no.2
    • /
    • pp.125-136
    • /
    • 2002
  • This paper is aimed to develop Tank Simulation Model. The model simulates Tank-to-Tank engagement and Tank-to-Helicopter engagement by considering Korean battlefield environment. The simulated entities are command tanks, fight tanks, scout helicopters, attack helicopters, anti-tank guided missiles, and decoys. In this paper, we explain the model operational concept, model development and finally we will show some illustrative examples.

Study on Vibration Characteristics of Fluid Tank Structure for Ship (유체 탱크 구조물의 접수 진동 특성에 관한 연구)

  • Seo, Myeng-Kab;Seok, Ho-Il;Lee, Chul-Won
    • Special Issue of the Society of Naval Architects of Korea
    • /
    • 2013.12a
    • /
    • pp.85-89
    • /
    • 2013
  • In the engine room and the aft body, there are so many fluid tanks such as fresh water tank and oil tank. The vibration analysis for the fluid tank structures has to consider the added mass effect due to the fluid. However, it is known that the result of the fluid tank has the difference according to the boundary condition of the fluid field such as infinite fluid and finite fluid. In this paper, a numerical case study is carried out for the research about the vibration characteristics of the fluid tank with various fluid field. In addition, an experimental study is carried out to verify the validity of the vibration analysis for the fluid tank structure.

  • PDF

Cause Analysis of Cone Roof Tank Collapse during Plant Construction (플랜트 공사 중 발생한 Cone Roof Tank 붕괴 사고 원인 분석)

  • Kim, Seung-Han;Kim, Byung-Suk
    • Journal of the Korea Safety Management & Science
    • /
    • v.18 no.3
    • /
    • pp.71-80
    • /
    • 2016
  • This study is on safety improvement measures through analysis of accident cases during plant storage tank construction. Storage tank is a general term for artificial ground facility constructed to store oil, water, gas, and other chemicals. Some companies have clustered storage tanks (tank farm). The construction methods vary according to the component and types of fluids. Because most of the construction procedures include lifting heavy weight materials using heavy construction equipment and are carried out at high places, storage tank construction contains more risk factors than normal aerial construction. Recently, major accidents such as storage tank collapse have occurred often, and cost many lives due to the characteristics of the structure. In this study we would like to analyze the cause of these accidents and propose measures to improve safety.

Simulation on Drop and Penetration Tests of a Fuel Tank (연료탱크의 낙하 및 관통 시험 시뮬레이션)

  • Park, Sun-Young;Bae, Jaesung;Hwang, Jai-Hyuk;Lee, Soo-Yong
    • Journal of Aerospace System Engineering
    • /
    • v.2 no.2
    • /
    • pp.8-13
    • /
    • 2008
  • The fuel tank systems of fixed wing and rotary wing aircrafts require the self-sealing and crash-worthiness for their survivability. For these requirements, the flexible composite fuel tank is generally used. In this study, the drop and penetration performance of a fuel tank is investigated. The FE simulation includes the drop and penetration test of a fuel tank using MSC.DYTRAN. MSC.DYTRAN can provide the fluid-structure modeling of these test from Euler and Lagrange grids. Using MSC.DYTRAN, the finite modeling of the test cube of the flexible fuel tank and its FE simulation are performed for various environments. The simulation results can show if the test cube satisfies the performance requirements of the fuel tank.

  • PDF

Improvement of Septic Tank for Piggery Wastewater Treatment of Small Pig Farm (소규모 농가용 가축 뇨.오수 정화조 개선에 관한 연구)

  • 전병수;곽정훈;김태일;유용희;양창범;김형호;한정대
    • Journal of Animal Environmental Science
    • /
    • v.5 no.3
    • /
    • pp.175-180
    • /
    • 1999
  • This study was carried out to improve septic tank for piggery wastewater treatment of small pig farm. Septic tank were consisted of screen tank, aeration tank with two steps, settling tank, and filtering tank. Aeration tanks were filled with ALC of ø4~5cm. All operation steps were performed by timer from influent to effluent. Septic tank decreased BOD by 94.7% from 4,298.3mg/$\ell$ to 226.3mg/$\ell$ and also decreased SS by 92.4%, from 2,231.3mg/$\ell$ to 161.0mg/$\ell$, respectively.

Shaking Table Test of Steel Cylindrical Liquid Storage Tank Considering the Roof Characteristics

  • Bae, Doobyong;Park, Jang Ho
    • International journal of steel structures
    • /
    • v.18 no.4
    • /
    • pp.1167-1176
    • /
    • 2018
  • Steel cylindrical tanks are widely used for the storage of hazardous substances of which leakage must be prevented under any circumstances. However, the dynamic response of the steel cylindrical liquid storage tank depends sensitively on the fluid-structure interaction and the vibration of the tank structure and necessitates clarification for the safety of the tank structure. This paper presents the results of shaking table tests performed to examine the dynamic behavior of a scaled cylindrical steel tank model considering the presence or not of fixed roof and added mass at the top of the tank for various fluid levels. The test results confirm the occurrence of both beam-type and oval-type vibration modes and show that the larger content of liquid inside the container amplified the acceleration along the height of the cylindrical tank. The oval-type vibration modes are seen to be more dominant in case of large water-to-structure mass ratio.

Design Safety Analysis of $9\%$ Nickel Steel Structure in Inner Tank Storage System (내부탱크 저장 시스템에서 $9\%$ 니켈강재 구조물의 설계 안전성에 관한 연구)

  • Kim Chung Kyun;Choi Dong Yul
    • Journal of the Korean Institute of Gas
    • /
    • v.5 no.4 s.16
    • /
    • pp.49-55
    • /
    • 2001
  • This paper presents the design safety analysis of the inner tank structure, which is manufactured by 9 percent nickel steel sheets in the full containment type LNG storage tank. The FEM computed results indicate that top girder and several stiffener rings of the inner tank play an important role for controlling the deformation and stress intensity of the inner tank structure. The hydrostatic pressure due to cryogenic fluids gave more influential to the deformation of the inner tank wall compared with that of a cryogenic temperature of $-162^{\circ}C$. But, the deformation and stress of the inner tank. which is produced by the buckling loads, are very small because the external load is not applied to the top of the inner tank. This indicates the role of top girder and stiffener rings of the inner tank model is not important in full containment LNG storage tank.

  • PDF

A Study on the Strength Safety of the Prestressed Concrete Outer Tank for a Membrane LNG Storage Tank (멤브레인식 LNG 저장탱크용 PC 외부탱크의 강도안전성에 관한 연구)

  • Kim, Chung-Kyun;Kim, Do-Hyun
    • Journal of the Korean Institute of Gas
    • /
    • v.13 no.1
    • /
    • pp.21-27
    • /
    • 2009
  • This paper presents the numerical study on the strength safety of the prestressed concrete outer tank for a LNG storage tank, which is manufactured by sets of membrane panels with special corrugations. This study for a finite element analysis assumes that the membrane panel of the inner tank was fractured and the liquefied natural gas stored in the inner membrane tank was leaked to the prestressed concrete outer tank. The stress and displacement of the outer tank have been analyzed for five different loadings, which are originated by a hydrostatic pressure and a weight of a LNG, a temperature difference, a weight of the prestressed concrete and a boil-off gas pressure. The computed FEM results indicate that the PC outer tank with a storage capacity of 200,000$m^3$ has a good strength safety for a leaked LNG from the membrane inner tank, but the increased cryogenic loadings in which are originated by a leaked LNG decreases the strength safety of the PC structure. This may lead to the collapse of the outer storage tank.

  • PDF

The Experimental Research for the Use Characteristics of the Passive and Active type Domestic Solar Hot Water Systems (자연형 및 설비형 태양열 온수기의 이용특성에 대한 실험적 연구)

  • Lee, Dong-Won;Kwak, Hee-You
    • Journal of the Korean Solar Energy Society
    • /
    • v.33 no.5
    • /
    • pp.82-88
    • /
    • 2013
  • There are the stirring test and drain test in the daily performance test to determine the thermal performance of a domestic solar hot water system. The drain test is a test that measures the discharge heating rate while drain the hot water from the top of the storage tank and supply the city water to the bottom of the tank. From the perspective of the user, this drain test is more effective than the stirring test. In this study, the thermal performance were compared through the drain test for a passive type and an active type domestic solar hot water systems consisting of the same storage tank and collectors. At this point, a passive type was used the horizontal storage tanks, and an active type was used vertical storage tank. In the drain test, when the hot water drained up to the reference hot water temperature, an active type which have vertical storage tank represents excellent daily performance than a passive type which have horizontal storage tank regardless of weather conditions. The reason for this is because the vertical storage tank is advantageous to thermal stratification in the tank. After the drain test, the residual heat for the horizontal storage tank was much more than the vertical storage tank, but in the next day the amount of discharged heat were less than the those of vertical storage tank neither. Thus, the solar water heating system which have horizontal storage tank should be adopted preheating control method rather than separate using control method when connected with auxiliary heat source device.