• Title/Summary/Keyword: Tandem reaction

Search Result 175, Processing Time 0.027 seconds

Bioequivalence of Atorva Tablet® to Lipitor Tablet® (Atorvastatin 20 mg) (리피토정® (아토르바스타틴 20 mg)에 대한 아토르바정®의 생물학적동등성)

  • Lim, Hyun-Kyun;Lee, Tae-Ho;Lee, Jae-Hyun;Youm, Jeong-Rok;Song, Jin-Ho;Han, Sang-Beom
    • Journal of Pharmaceutical Investigation
    • /
    • v.38 no.2
    • /
    • pp.135-142
    • /
    • 2008
  • The present study describes the evaluation of the bioequivalence of two atorvastatin tablets, Lipitor $Tablet^{(R)}$ (Pfizer, reference drug) and Atorva $Tablet^{(R)}$ (Yuhan, test drug), according to the guidelines of Korea Food and Drug Administration (KFDA). Forty-nine healthy male Korean volunteers received each medicine at the atorvastatin dose of 40 mg in a $2{\times}2$ crossover study with a two weeks washout interval. After drug administration, serial blood samples were collected at a specific time interval from 0-48 hours. The plasma atorvastatin concentrations were monitored by an high performance liquid chromatography -tandem mass spectrometer (LC-MS/MS) employing electrospray ionization technique and operating in multiple reaction monitoring (MRM) and positive ion mode. The total chromatographic run time was 4.5 min and calibration curves were linear over the concentration range of 0.1-100 ng/mL for atorvastatin. The method was validated for selectivity, sensitivity, linearity, accuracy and precision. $AUC_t$ (the area under the plasma concentration-time curve from time zero to 48hr) was calculated by the linear log trapezoidal rule method. $C_{max}$ (maximum plasma drug concentration) and $T_{max}$ (time to reach $C_{max}$) were complied trom the plasma concentration-time data. Analysis of variance was carried out using logarithmically transformed $AUC_t$ and $C_{max}$. No significant sequence effect was found for all of the bioavailability parameters indicating that the crossover design was properly performed. The 90% confidence intervals of the $AUC_t$ ratio and the $C_{max}$ ratio for Atorva $Tablet^{(R)}$ / Lipitor $Tablet^{(R)}$ were ${\log}\;0.9413{\sim}{\log}\;1.0179$ and ${\log}\;0.831{\sim}{\log}\;1.0569$, respectively. These values were within the acceptable bioequivalence intervals of ${\log}\;0.8{\sim}{\log}\;1.25$. Based on these statistical considerations, it was concluded that the test drug, Atorva $Tablet^{(R)}$ was bioequivalent to the reference drug, Lipitor $Tablet^{(R)}$.

Development and validation of an LC-MS/MS method for the simultaneous analysis of 26 anti-diabetic drugs in adulterated dietary supplements and its application to a forensic sample

  • Kim, Nam Sook;Yoo, Geum Joo;Kim, Kyu Yeon;Lee, Ji Hyun;Park, Sung-Kwan;Baek, Sun Young;Kang, Hoil
    • Analytical Science and Technology
    • /
    • v.32 no.2
    • /
    • pp.35-47
    • /
    • 2019
  • In this study, high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) was employed to detect 26 antidiabetic compounds in adulterated dietary supplements using a simple, selective method. The work presented herein may help prevent incidents related to food adulteration and restrict the illegal food market. The best separation was obtained on a Shiseido Capcell Pak(R) C18 MG-II ($2.0mm{\times}100mm$, $3{\mu}m$), which improved the peak shape and MS detection sensitivity of the target compounds. A gradient elution system composed of 0.1 % (v/v) formic acid in distilled water and methanol at a flow rate of 0.3 mL/min for 18 min was utilized. A triple quadrupole mass spectrometer with an electrospray ionization source operated in the positive or negative mode was employed as the detector. The developed method was validated as follows: specificity was confirmed in the multiple reaction monitoring mode using the precursor and product ion pairs. For solid samples, LOD ranged from 0.16 to 20.00 ng/mL and LOQ ranged from 0.50 to 60.00 ng/mL, and for liquid samples, LOD ranged from 0.16 to 20.00 ng/mL and LOQ ranged from 0.50 to 60.00 ng/mL. Satisfactory linearity was obtained from calibration curves, with $R^2$ > 0.99. Both intra and inter-day precision were less than 13.19 %. Accuracies ranged from 80.69 to 118.81 % (intra/inter-day), with a stability of less than 14.88 %. Mean recovery was found to be 80.6-119.0 % and less than 13.4 % RSD. Using the validated method, glibenclamide and pioglitazone were simultaneously determined in one capsule at concentrations of 1.52 and 0.53 mg (per capsule), respectively.

Determination of finasteride in human serum by LC-MS/MS (LC-MS/MS를 이용한 혈청 중 finasteride 분석)

  • Nam, Hye-Seon;Nam, Kyong-Hee;Jung, Su-Hee;Lee, Jang-Woo;Kang, Jin-Yeong;Hong, Soon-Keun;Kim, Tae-Sung;Kang, Tae-Seok;Yoon, Hae-Jung;Lee, Kwang-Ho;Rhee, Gyu-Seek
    • Analytical Science and Technology
    • /
    • v.24 no.5
    • /
    • pp.345-351
    • /
    • 2011
  • A liquid chromatography-electrospray ionization tandem mass spectrometry (LC-ESI/MS/MS) method was developed and validated for the determination of finasteride in human serum. Beclomethasone was used as internal standard (IS) and liquid-liquid extraction (LLE) using methyl tert-butyl ether (MTBE) was carried out to isolate analyte. The mass transitions monitored in multiple reaction monitoring (MRM) in positive ion mode were m/z 373.2${\rightarrow}$305.2 for finasteride and m/z 409.3${\rightarrow}$391.2 for IS. Retention times of finasteride and IS were 5.81 and 5.46 min, respectively. The limit of quantitation (LOQ) was 0.1 ng/mL and the calibration curve showed good linearity in the range of 0.1~20.0 ng/mL ($R^2$=0.9997). The intra-day assay precision and accuracy were in the range 6.3~10.6% and 97.3~103.6%, respectively, and the inter-day assay precision and accuracy were in the range 0.8~5.2% and 99.8~102.5%, respectively. The sample extract recovery of the method was 80~83%.

Analysis of dutasteride in human serum by LC-MS/MS (LC-MS/MS를 이용한 혈청 중 dutasteride 분석)

  • Nam, Hye-Seon;Nam, Kyong-Hee;Jung, Su-Hee;Lee, Jang-Woo;Kang, Jin-Yeong;Hong, Soon-Keun;Kim, Tae-Sung;Jung, Ki-Kyung;Kang, Tae-Seok;Yoon, Hae-Jung;Lee, Kwang-Ho;Rhee, Gyu-Seek
    • Analytical Science and Technology
    • /
    • v.25 no.1
    • /
    • pp.76-82
    • /
    • 2012
  • The determination and confirmation of dutasteride in human serum was performed by a liquid chromatography-electrospray ionization tandem mass spectrometry (LC-ESI/MS/MS). Beclomethasone as an internal standard (I.S.) was added to the serum and the mixed sample was pretreated by liquid-liquid extraction (LLE) with methyl tert-butyl ether (MTBE). The mass transitions of dutasteride and I.S. monitored in multiple reaction monitoring (MRM) were m/z 529.6${\rightarrow}$461.5 and m/z 409.3${\rightarrow}$391.2, respectively, and the retention times were 6.45 and 5.46 min, respectively. The calibration curve was linear in the concentration range of 0.5~30.0 ng/mL ($R^2$= 0.9999) and the limit of quantitation (LOQ) was found to be 0.5 ng/mL. The recovery of dutasteride was shown to be 66~72%. The intra-day assay precision and accuracy were in the range 3.5~5.5% and 85.7~89.9%, respectively, and the interday assay precision and accuracy were in the range 4.2~5.8% and 90.8~95.8%, respectively.

Development and Validation of Analytical Method for Determination of Fungicide Spiroxamine Residue in Agricultural Commodities Using LC-MS/MS (LC-MS/MS를 이용한 농산물 중 살균제 Spiroxamine의 시험법 개발 및 검증)

  • Park, Shin-Min;Do, Jung-Ah;Lim, Seung-Hee;Yoon, Ji-Hye;Pak, Won-Min;Shin, Hye-Sun;Kuk, Ju-Hee;Chung, Hyung-Wook
    • Journal of Food Hygiene and Safety
    • /
    • v.33 no.4
    • /
    • pp.296-305
    • /
    • 2018
  • Spiroxamine, one of fungicides, is used to control powdery mildew in various crops and black yellow sigatoka in bananas. The major strength of spiroxamine is to control powdery mildew in various crops and bananas yellow sigatoka in bananas. The compound has shown a high level of activity, good persistence and crop tolerance. Besides powdery mildew, good control of rust, net blotch and Rhynchosporium diseases been indicated in cereals, together with a complementary activity against Septoria diseases. In 2017, the maximum residue limit (MRL) of spiroxamine established in Korea. According to Ministry of ood and rug afety) regulations, spiroxamine residues defined only parent compound. Thus, a analytical method is needed to estimate the residue level of the parent compound. The objective of this study was to develop and validate analytical method for spiroxamine in representative agricultural commodities. Samples were extracted with acetonitrile and partitioned with dichloromethane to remove the interfering substances. The analyte were quantified and confirmed liquid chromatograph-tandem mass spectrometer (LC-MS/MS) in positive-ion mode using multiple reaction monitoring (MRM). Matrix matched calibration curves were linear over the calibration ranges ($0.0005{\sim}0.1{\mu}g/mL$) for the analyte in blank extract with coefficient of determination ($r^2$) > 0.99. For validation purposes, recovery studies will be carried out at three different concentration levels (LOQ, 10LOQ, and 50LOQ) performing five replicates at each level. The recoveries 70.6~104.6% with relative standard deviations (RSDs) less than 10%. All values were consistent with the criteria ranges in the Codex guidelines (CAC/GL40, 2003) and MFDS guidelines. proposed analytical method be used as an official analytical method in the Republic of Korea.

Development of Simultaneous Analytical Method for Determination of Isoxaflutole and its Metabolite (Diketonitrile) residues in Agricultural Commodities Using LC-MS/MS (LC-MS/MS를 이용한 농산물 중 Isoxaflutole과 대사산물(Diketonitrile)의 동시시험법 개발)

  • Ko, Ah-Young;Kim, Heejung;Do, Jung Ah;Jang, Jin;Lee, Eun-Hyang;Ju, Yunji;Kim, Ji Young;Chang, Moon-Ik;Rhee, Gyu-Seek
    • The Korean Journal of Pesticide Science
    • /
    • v.20 no.2
    • /
    • pp.93-103
    • /
    • 2016
  • A simultaneous analytical method was developed for the determination of isoxaflutole and metabolite (diketonitrile) in agricultural commodities. Samples were extracted with 0.1% acetic acid in water/acetonitrile (2/8, v/v) and partitioned with dichloromethane to remove the interference obtained from sample extracts, adjusting pH to 2 by 1 N hydrochloric acid. The analytes were quantified and confirmed via liquid chromatograph-tandem mass spectrometer (LC-MS/MS) in positive-ion mode using multiple reaction monitoring (MRM). Matrix matched calibration curves were linear over the calibration ranges ($0.02-2.0{\mu}g/mL$) for all the analytes into blank extract with $r^2$ > 0.997. For validation purposes, recovery studies were carried out at three different concentration levels (LOQ, 10LOQ, and 50LOQ) performing five replicates at each level. The recoveries were ranged between 72.9 to 107.3%, with relative standard deviations (RSDs) less than 10% for all analytes. All values were consistent with the criteria ranges requested in the Codex guideline (CAC/GL40, 2003). Furthermore, inter-laboratory study was conducted to validate the method. The proposed analytical method was accurate, effective, and sensitive for isoxaflutole and diketonitrile determination in agricultural commodities.

Development and Validation of an Analytical Method for Determination of Fungicide Tridemorph in Agricultural Commodities Using LC-MS/MS (LC-MS/MS를 이용한 농산물 중 살균제 tridemorph의 시험법 개발 및 검증)

  • Pak, Won-Min;Do, Jung-Ah;Lim, Seung-Hee;Park, Shin-Min;Yoon, Ji-Hye;Lee, Dong-seouk;Chang, Moon-Ik
    • Journal of Food Hygiene and Safety
    • /
    • v.32 no.4
    • /
    • pp.290-297
    • /
    • 2017
  • The purpose of this study was developed for the determination of tridemorph in agricultural commodities samples. Tridemorph residues in samples were extracted with acetonitrile, partitioned with saline water, and then purified using and aminopropyl ($NH_2$) SPE catridge. The purified samples were quantified and confirmed via liquid chromatograph-tandem mass spectrometer (LC-MS/MS) in positive ion mode using multiple reaction monitoring (MRM). Matrix-matched calibration curves were linear over the calibration ranges (0.005~2.5 ng) into a blank extract with $r^2$ > 0.999. The limits of detection and quantification were 0.001 and 0.005 mg/kg, respectively. The average recovery ranged between 75.9% and 103.7% at different concentration levels (LOQ, 10 LOQ, 50 LOQ, n = 5) with relative standard deviations (RSDs) less than 9.0%. An interlaboratory study was conducted to validate the method by Korea Advanced Food Research Institute. The average recovery ranged between 87.0% and 109.2% at different concentration levels (LOQ, $10{\times}LOQ$, $50{\times}LOQ$, n = 5) with relative standard deviations (RSDs) less than 8.0%. All values were consistent with the criteria ranges requested in the Codex guidelines (CAC/GL40, 2003) and Food Safety Evaluation Department guidelines (2016). The results prove that the developed analytical methods is accurate, effective and sensitive for tridemorph determination.

Determination of plasma C16-C24 globotriaosylceramide (Gb3) isoforms by tandem mass spectrometry for diagnosis of Fabry disease (패브리병(Fabry) 진단을 위한 혈장 중 Globotriaosylceramide (Gb3)의 탠덤매스 분석법 개발과 임상 응용)

  • Yoon, Hye-Ran;Cho, Kyung-Hee;Yoo, Han-Wook;Choi, Jin-Ho;Lee, Dong-Hwan;Zhang, Kate;Keutzer, Joan
    • Journal of Genetic Medicine
    • /
    • v.4 no.1
    • /
    • pp.45-52
    • /
    • 2007
  • Purpose : A simple, rapid, and highly sensitive analytical method for Gb3 in plasma was developed without labor-ex tensive pre-treatment by electrospray ionization MS/ MS (ESI-MS/MS). Measurement of globotriaosy lceramide (Gb3, ceramide trihex oside) in plasma has clinical importance for monitoring after enzyme replacement therapy in Fabry disease patients. The disease is an X-linked lipid storage disorder that results from a deficiency of the enzyme ${\alpha}$-galactosidase A (${\alpha}$-Gal A). The lack of ${\alpha}$-Gal A causes an intracellular accumulation of glycosphingolipids, mainly Gb3. Methods : Only simple 50-fold dilution of plasma is necessary for the extraction and isolation of Gb3 in plasma. Gb3 in diluted plasma was dissolved in dioxane containing C17:0 Gb3 as an internal standard. After centrifugation it was directly injected and analyzed through guard column by in combination with multiple reaction monitoring mode of ESI-MS/MS. Results : Eight isoforms of Gb3 were completely resolved from plasma matrix. C16:0 Gb3 occupied 50% of total Gb3 as a major component in plasma. Linear relationship for Gb3 isoforms w as found in the range of 0.001-1.0 ${\mu}g$/mL. The limit of detection (S/N=3) was 0.001 ${\mu}g$/mL and limit of quantification was 0.01 ${\mu}g$/mL for C16:0 Gb3 with acceptable precision and accuracy. Correlation coefficient of calibration curves for 8 Gb3 isoforms ranged from 0.9678 to 0.9982. Conclusion : This quantitative method developed could be useful for rapid and sensitive 1st line Fabry disease screening, monitoring and/or diagnostic tool for Fabry disease.

  • PDF

Development of an Official Analytical Method for Determination of Phorate and its Metabolites in Livestock Using LC-MS/MS (LC-MS/MS를 이용한 축산물 중 Phorate 및 대사산물 5종 동시분석법 개발)

  • Ko, Ah-Young;Kim, Heejung;Jang, Jin;Lee, Eun Hyang;Ju, Yunji;Noh, Mijung;Kim, Seongcheol;Park, Sung-Won;Chang, Moon-Ik;Rhee, Gyu-Seek
    • Journal of Food Hygiene and Safety
    • /
    • v.30 no.3
    • /
    • pp.272-280
    • /
    • 2015
  • A simultaneous official method was developed for the determination of phorate and its metabolites (phorate sulfoxide, phorate sulfone, phorate oxon, phorate oxon sulfoxide, phorate oxon sulfone) in livestock samples. The analytes were quantified and confirmed via liquid chromatograph-tandem mass spectrometer (LC-MS/MS) in positive ion mode using multiple reaction monitoring (MRM). Phorate and its metabolites were extracted from beef and milk samples with acidified acetonitrile (containing 1% acetic acid) and partitioned with anhydrous magnesium sulfate. Then, the extract was purified through primary secondary amine (PSA) and C18 dispersive sorbent. Matrix matched calibration curves were linear over the calibration ranges (0.005-0.5 mg/L) for all the analytes into blank extract with $r^2$ > 0.996. For validation purposes, recovery studies were carried out at three different concentration levels (beef 0.004, 0.04 and 0.2 mg/kg; milk 0.008, 0.04 and 0.2 mg/kg, n = 5). The recoveries were within 79.2-113.9% with relative standard deviations (RSDs) less than 19.2% for all analytes. All values were consistent with the criteria ranges requested in the Codex guidelines. The limit of quantification was quite lower than the maximum residue limit (MRL) set by the Ministry of Food and Drug Safety (0.05 mg/kg). The proposed analytical method was accurate, effective and sensitive for phorate and its metabolites determination and it will be used to as an official analytical method in Korea.

Simultaneous Determination of Penicillin Antibiotics in Meat using Liquid Chromatography Tandem Mass Spectrometry (LC-MS/MS를 이용한 육류 중 페니실린계 항생제 8종의 동시분석 및 적용성 검증)

  • Kim, Myeong-Ae;Yoon, Su-Jin;Kim, MeeKyung;Cho, Yoon-Jae;Choi, Sun-Ju;Chang, Moon-Ik;Lee, Sang-Mok;Kim, Hee-Jeong;Jeong, Jiyoon;Rhee, Gyu-Seek;Lee, Sang-Jae
    • Journal of Food Hygiene and Safety
    • /
    • v.29 no.2
    • /
    • pp.131-140
    • /
    • 2014
  • The objective of this study was to develop a simultaneous method of 8 penicillin antibiotics including amoxicillin, ampicillin, cloxacillin, dicloxacillin, nafcillin, oxacillin, penicillin G and penicillin V in meat using LC-MS/MS. The procedure involves solid phase extraction with HLB cartridge and subsequent analysis by LC-MS/MS. To optimize MS analytical condition of 8 compounds, each parameter was established by multiple reaction monitoring in positive ion mode. The chromatographic separation was achieved on a $C_{18}$ column with a mobile phase of 0.05% formic acid and 0.05% formic acid in acetonitrile at a flow rate of 0.2 mL/min for 20 min with a gradient elution. The developed method was validated for specificity, linearity, accuracy and precision in beef, pork and chicken. The recoveries were 71.0~106%, and relative standard deviations (RSD) were 4.0~11.2%. The limit of detection (LOD) and the limit of quantification (LOQ) were 0.003~0.008 mg/kg and 0.01~0.03 mg/kg, respectively, that are below maximum residue limit (MRL) of the penicillins. This study also performed survey of residual penicillin antibiotics for 193 samples of beef, pork and chicken collected from 9 cities in Korea. Penicillins were not found in all the samples except a sample of pork which contained cloxacillin (concentration of 0.08 mg/kg) below the MRL (0.3 mg/kg).