• 제목/요약/키워드: Tandem Mass Spectrometry (MS/MS)

검색결과 442건 처리시간 0.025초

Effects of Column Length and Particle Diameter on Phospholipid Analysis by Nanoflow Liquid Chromatography-Electrospray Ionization-Mass Spectrometry

  • Lee, Ju-Yong;Lim, Sang-Soo;Moon, Myeong-Hee
    • Mass Spectrometry Letters
    • /
    • 제2권3호
    • /
    • pp.65-68
    • /
    • 2011
  • The effects of column length and particle size on the efficiency of separation and characterization of phospholipids (PLs) are investigated using nanoflow liquid chromatography-electrospray ionization-tandem mass spectrometry (nLC-ESI-MS-MS). Since PLs are associated with cell proliferation, apoptosis, and signal transduction, it is of increasing interests in lipidomics to establish reliable analytical methods for the qualitative and quantitative profiling of PLs related to biomarker development in adult diseases. Due to the complexity of PLs, the preliminary separation of PLs is necessary prior to MS analysis. In this study, length of capillary column and the particle size of reversed phase ($C_{18}$) packing materials are varied to find a reliable condition for the high speed and high resolution separation using 8 PL standard mixtures. From experiments, it was found that a capillary column of nLC-ESI-MS-MS analysis for PL mixtures can be minimized to a 5 cm long pulled tip column packed with 3 ${\mu}m$ $C_{18}$ particles without losing resolution.

Gas Chromatography/Mass Spectrometry and Gas Chromatography/Tandem Mass Spectrometry of some s-Triazine Pesticides

  • Kim, Yoo-Joong;Kim, Myung-Soo
    • Bulletin of the Korean Chemical Society
    • /
    • 제10권2호
    • /
    • pp.196-200
    • /
    • 1989
  • Some s-triazine herbicides, namely simazine, atrazine, and propazine present as trace components in a complex mixture were analyzed by GC/MS and GC/MS/MS methods. Even though monitoring the molecular ions was the best in terms of sensitivity, adequate analysis could not be done when interfering species were present. When doubly charged ions which appeared at characteristic m/z values were monitored, chromatograms were rather free from interference. More importantly, selected reaction monitoring was found to provide a selective means of detection with general applicability.

Keratanase II Digestion Accompanied with a Liquid Chromatography/Tandem Mass Spectrometry for Urinary Keratan Sulfate Quantitative Analysis

  • Chuang, Chih-Kuang;Lin, Hsiang-Yu;Wang, Tuen-Jen;Huang, Sung-Fa;Lin, Shuan-Pei
    • Journal of mucopolysaccharidosis and rare diseases
    • /
    • 제3권1호
    • /
    • pp.20-27
    • /
    • 2017
  • Purpose: Mucopolysaccharidosis IV (MPS IV) is a disease characterized by deficient activity of N-acetylgalactosamine-6-sulfatase (GALNS) causing excessive lysosomal storage of keratan sulfate (KS). The identification of the relevant disaccharide units of KS after keratanase II digestion followed by liquid chromatography/tandem mass spectrometry detection (LC-MS/MS) is validated and applicable for the preliminary diagnosis of MPS IV. Methods: A total of 67 urine samples were collected and analyzed from 11 MPS IV patients comprising 10 MPS IVA and one MPS IVB patients, and 56 normal controls. Urinary glycosaminoglycan was first precipitated by the Alcian blue method followed by a digestion of keratanase II. The protonated species of the digested disaccharide products were detected by using multiple reaction monitoring experiment. Results: One particular disaccharide of KS was selected. The transition mass-to-charge (m/z) of the parent ion and its daughter ion after collision was $462.0{\rightarrow}97.0$, whereas the chondrosine used as an internal standard in this assay was m/z $353.9{\rightarrow}73.0$. The results corresponded well with the two-dimensional electrophoresis method. The quantities of urinary KS were significantly raised in confirmed MPS IV patients when comparing with those of normal controls ($170.2{\pm}81.1$ vs. $4.06{\pm}1.92{\mu}g/mL$). Conclusion: The LC-MS/MS method for MPS IVA determination is specific, sensitive, validated, and applicable for urinary KS quantification. This method can be used not only as a first-line biochemistry examination of MPS IVA, but also as an outcome survey after enzyme replacement therapy.

Quantitative Analysis of Lysophosphatidic Acid in Human Plasma by Tandem Mass Spectrometry

  • Kim, Ho-Hyun;Yoon, Hye-Ran;Pyo, Dong-Jin
    • Bulletin of the Korean Chemical Society
    • /
    • 제23권8호
    • /
    • pp.1139-1143
    • /
    • 2002
  • Analysis of lysophosphatidic acids (LPAs) is of clinical importance as they can serve a potential marker for ovarian and other gynecological cancers and obesity. It is critically important to develop a highly sensitive and specific method for the early detection of gynecological cancers to improve the overall outcome of this disease. We have established a novel quantification method of LPAs in human plasma by negative ionization tandem mass spectrometry (MS-MS) using multiple reaction monitoring (MRM) mode without the conventional TLC step. Protein-bound lipids, LPAs in plasma were extracted with methanol : chloroform (2:1) containing LPA C14:0 as an internal standard under acidic condition. Following back extraction with chloroform and water, the centrifuged lower phase was evaporated and reconstituted in methanol. The reconstituted solution was directly injected into electrospray source of MS/MS. For MRM mode, Q1 ions selected were m/z 409, 433, 435, 437 and 457 which corresponds to molecular mass [M-H]- of C16:0, C18:2, C18:1, C18:0 and C20:4 LPA, respectively. Q2 ions selected for MRM were m/z 79, phosphoryl product. Using MS/MS with MRM mode, all the species of LPAs were completely separated from plasma matrix without severe interferences. This method allowed simultaneous detection and quantification of different species of LPAs in a plasma over a linear dynamic range of 0.01-25 ㎛olL-1 . The detection limit of the method was 0.3 pmol/mL, with a correlation coefficient of 0.9983 in most LPAs analyzed. When applied to the plasmas of normal and gynecological cancer patients, this new method differentiated two different groups by way of total LPA level.

Study of Complexes of C2- and C6-dihydroceramides with Transition Metal Ions Using Electrospray Ionization Tandem Mass Spectrometry (ESI-MS/MS)

  • Lim, Jin-Yi;Kumar, Avvaru Praveen;Kim, Chang-Dae;Ahn, Chul-Jin;Yoo, Young-Jae;Lee, Yong-Ill
    • Bulletin of the Korean Chemical Society
    • /
    • 제30권2호
    • /
    • pp.397-401
    • /
    • 2009
  • The complexes of $C_2-\;and\;C_6$-dihydroceramides with transition metal ions have been investigated by using Electrospray ionization-tandem mass spectrometry (ESI-MS/MS). The formation and fragmentation pathways of several doubly charged cluster ions as well as singly charged cluster ions of $C_2-\;and\;C_6$-dihydroceramides with transition metal ions have studied by ESI-MS/MS in the positive mode. Under ESI conditions, dihydroceramides form singly and doubly charged complexes with transition metal ions $(Mn^{2+},\;Fe^{2+},\;Co^{2+},\;Ni^{2+},\;and\;Zn^{2+}\;except\;Cu^{2+})$ with the compositions of $[DHCer+M+2H^2O-H]^+,\;[2DHCer+M+2H2O-H]^+,\;[3DHCer+M+2H2O-H]^+,\;[2DHCer+M]^{2+},\;[3DHCer+M]^{2+},\;[4DHCer+M]^{2+},\;[5DHCer+M]^{2+},\;and\;[6DHCer+M]^{2+}\;(DHCer\;=\;C_2-\;or\;C_6$-dihydroceramide, M = transition metal ion). The different complexation behavior of copper is responsible for relatively lower affinity of dihydroceramides to copper compared to those of other transition metals. It is also found that in the mass spectrum of the dihydroceramide complexes with copper(II), [2DHCer+Cu-H]$^+$ was observed with considerable intensity as well as [2DHCer+Cu+2$H_2O-H]^+$ due to its different geometry from those of other metals.

Simultaneous Liquid Chromatography Tandem Mass Spectrometric Determination of 35 Prohibited Substances in Equine Plasma for Doping Control

  • Kwak, Young Beom;Yu, Jundong;Yoo, Hye Hyun
    • Mass Spectrometry Letters
    • /
    • 제13권4호
    • /
    • pp.158-165
    • /
    • 2022
  • Many therapeutic class drugs such as beta-blocker, corticosteroids, NSAIDs, etc are prohibited substances in the horse racing industry. Liquid chromatography-tandem mass spectrometry (LC-MS/MS) technology makes it possible to isolate drugs from interference, enables various drug analyses in complex biological samples due to its sensitive sensitivity, and has been successfully applied to doping control. In this paper, we describe a rapid and sensitive method based on solid-phase extraction (SPE) using solid phase cartridge and LC-MS/MS to screen for different class's 35 drug targets in equine plasma. Plasma samples were pretreated by SPE with the NEXUS cartridge consisted non-polar carbon resin and minimum buffer solvent. Chromatographic separation of the analytes was performed on ACQUITY HSS C18 column (2.1 × 150 mm, 1.8 ㎛). The elution gradient was conducted with 5 mM ammonium formate (pH 3.0) in distilled water and 0.1% formic acid in acetonitrile at a flow rate of 0.25 mL/min. The selected reaction monitoring (SRM) mode was used for drug screening with multiple transitions in the positive ionization mode. The specificity, limit of detection, recovery, and stability was evaluated for validation. The method was found to be sensitive and reproducible for drug screening. The method was applied to plasma sample analysis for the proficiency test from the Association of Racing Chemist.

Identification of Ceftiofur Oxidation Products by High-Performance Liquid Chromatography/Electrospray Ionization/Tandem Mass Spectrometry

  • Lim, Young-Hee;Park, Deok-Hie;Youn, Yeu-Young;Kim, Kyung-Hoon;Cho, Hye-Sung
    • Mass Spectrometry Letters
    • /
    • 제2권1호
    • /
    • pp.16-19
    • /
    • 2011
  • Oxidation products of ceftiofur were formed in hydrogen peroxide solution. The structures of the ceftiofur oxidation products were characterized by high-performance liquid chromatography/electrospray ionization/tandem mass spectrometry (HPLC/ESI/MS/MS). The products were identified as compounds oxidized at the sulfur of a cephem ring. For further analysis, experiments were performed using $O^{18}$-labeled hydrogen peroxide. In addition, density-functional calculations were carried out for six possible oxidation products to support the experimental results.

LC-MS/MS를 이용한 벌꿀 중 스트렙토마이신 분석 (Analysis of streptomycin in honey by LC-MS/MS)

  • 심영은;명승운
    • 분석과학
    • /
    • 제21권5호
    • /
    • pp.424-431
    • /
    • 2008
  • 스트렙토마이신은 아미노글리코사이드계 항생제중의 하나로써 가축, 가금류의 질병 치료와 예방에 널리 사용되고 있다. 국내에서는 양봉용으로는 허가되어 있지 않지만 일부 국가에서는 유럽형 부저병과 같은 세균성 벌꿀 질병의 치료에 사용되는 것으로 알려져 있다. LC-MS/MS를 이용하여 벌꿀 중에 잔류하는 스트렙토마이신(streptomycin)을 분석하는 방법을 확립하였다. 확립된 분석법은 재현성과 정밀성을 높이고 미량까지 검출할 수 있도록 회수율을 높이기 위하여 정제 및 추출과정을 최적화 하였으며, 효과적인 분석을 위해서 액체 크로마토그래피(HPLC) 와 텐뎀 질량분석법(tandem mass spectrometry)의 조건들을 최적화하였다. 확립된 방법은 5.0~50.0 ug/kg 농도에서 5.5~14%인 정밀성(RSD)을 나타내었으며, bias로써 -10.0~8.0%의 정확도를 나타내었다. 한편, 스트렙토마이신을 벌꿀 공 시료에 10.0 ug/kg의 농도로 소량첨가한 후 얻은 회수율은 74%이었고, 정량한계(LOQ)는 0.75 ug/kg이었다. 확립된 벌꿀 중 스트렙토마이신 분석법을 이용하여 실제 벌꿀시료에 적용한 결과 몇몇 시료에서 소량의 스트렙토마이신이 검출되었다.