• Title/Summary/Keyword: Tall building structures

Search Result 343, Processing Time 0.02 seconds

The First Performance-based Structural Fire Design for Office Building in Korea

  • Min Jae Park
    • International Journal of High-Rise Buildings
    • /
    • v.12 no.3
    • /
    • pp.235-239
    • /
    • 2023
  • In this study, the fire resistance performance of the concrete-filled steel tube (CFT) columns and thin steel-plate composite (TSC) beams installed at a 20-story office building were designed using a performance-based structural fire design. Because of the lack of any specific provisions in the building code and guidelines for structural engineers about the performance-based approach, the only prescriptive approach has been selected for designing fire-resistant structures in Korea. To evaluate the fire resistance performance of the CFT columns and TSC beams, finite element analysis verified by the experimental results studied by several researchers was conducted with ABAQUS. From the fire scenario, the temperature distributions of the CFT columns and TSC beams were found via finite element analysis and the behaviors of the CFT columns and TSC beams were investigated in the structural field based on the temperature distribution.

Seismic Response Control of Building Structures using Semiactive Smart Dampers (준능동 스마트 감쇠기를 사용한 빌딩구조물의 지진응답제어)

  • Kim Hyun-Su;Raschke Paul N.;Lee Dang-Guen
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2006.04a
    • /
    • pp.451-458
    • /
    • 2006
  • The goal of many researchers in the field of structural engineering is to reduce both damage to building structures and discomfort of their inhabitants during strong motion seismic events. The present paper reports on analytical work conducted with this aim in mind as a prior research of experimental study. A four-story, 6.4 m tall, laboratory model of a building is employed as a example structure. The laboratory structure has graphite epoxy columns and each floor is equipped with a chevron brace that serves to resist inter-story drift with the installation of a magnetorheological (MR) damper. An artificial excitation has been generated with a robust range of seismic characteristics. A series of numerical simulations demonstrates that an optimized fuzzy controller is capable of robust performance for a variety of seismic base motions. Optimization of the fuzzy controller is achieved using multi-objective genetic algorithm(MOGA), i.e. NSGA-II. Multiple objective functions are used in order to reduce both peak and root-means-squared displacement and accelerations at the floor levels of the building.

  • PDF

Predicting the lateral displacement of tall buildings using an LSTM-based deep learning approach

  • Bubryur Kim;K.R. Sri Preethaa;Zengshun Chen;Yuvaraj Natarajan;Gitanjali Wadhwa;Hong Min Lee
    • Wind and Structures
    • /
    • v.36 no.6
    • /
    • pp.379-392
    • /
    • 2023
  • Structural health monitoring is used to ensure the well-being of civil structures by detecting damage and estimating deterioration. Wind flow applies external loads to high-rise buildings, with the horizontal force component of the wind causing structural displacements in high-rise buildings. This study proposes a deep learning-based predictive model for measuring lateral displacement response in high-rise buildings. The proposed long short-term memory model functions as a sequence generator to generate displacements on building floors depending on the displacement statistics collected on the top floor. The model was trained with wind-induced displacement data for the top floor of a high-rise building as input. The outcomes demonstrate that the model can forecast wind-induced displacement on the remaining floors of a building. Further, displacement was predicted for each floor of the high-rise buildings at wind flow angles of 0° and 45°. The proposed model accurately predicted a high-rise building model's story drift and lateral displacement. The outcomes of this proposed work are anticipated to serve as a guide for assessing the overall lateral displacement of high-rise buildings.

Effect of taper on fundamental aeroelastic behaviors of super-tall buildings

  • Kim, Yong Chul;Tamura, Yukio;Yoon, Sung-Won
    • Wind and Structures
    • /
    • v.20 no.4
    • /
    • pp.527-548
    • /
    • 2015
  • Aeroelastic wind tunnel experiments were conducted for conventional and tapered super-tall building models to investigate the effect of taper on fundamental aeroelastic behaviors in various incident flows. Three incident flows were simulated: a turbulent boundary-layer flow representing urban area; a low-turbulent flow; and a grid-generated flow. Results were summarized focusing on the effect of taper and the effect of incident flows. The suppression of responses by introducing taper was profound in the low-turbulence flow and boundary-layer flow, but in the grid-generated flow, the response becomes larger than that of the square model when the wind is applied normal to the surface. The effects of taper and incident flows were clearly shown on the normalized responses, power spectra, stability diagrams and probability functions.

A Development of Active Controller for the Vibration of Tall Civil St (고층 빌딩의 진동에 대한 능동제어기의 개발)

  • Lee, Y.J.;Chang, Y.H.;Song, B.M.;Lee, K.S.
    • Proceedings of the KIEE Conference
    • /
    • 1997.07b
    • /
    • pp.689-692
    • /
    • 1997
  • This paper is attempt to develop an active controller for the vibration of tall civil structures due to earthquake-induced ground acceleration. Various active control methods are applied to an 8 story base isolated system(BIS) with a fumed mass damper(TMD) at the base of the building. The results are also investigated.

  • PDF

EFFECTS OF NEAR-FIELD PULSE-LIKE GROUND MOTIONS ON TALL BUILDINGS

  • K. Malhotra, Praveen
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 1998.10a
    • /
    • pp.3-11
    • /
    • 1998
  • Response of tall buildings to near-field ground motions with distinct low-frequency pulses can differ dramatically from, for example, the response to the 1940 El Centro ground motion. For the same peak ground acceleration (PGA) and duration of shaking, ground motions with a pulse-like characteristic can generate much higher base shear, inter-story drifts and roof displacement in a high-rise building as compared to ground motions without the characteristic pulse. Also, the ductility demand is much higher and the effectiveness of supplemental damping is lower for pulse-like ground motions. This paper presents a simple interpretation of the response characteristics for two recorded and one synthetic near-field pulse-like ground motions.

  • PDF

Experimental and Computational Investigation of Wind Flow Field on a Span Roof Structure

  • K B Rajasekarababu;G Vinayagamurthy;Ajay Kumar T M;Selvirajan S
    • International Journal of High-Rise Buildings
    • /
    • v.11 no.4
    • /
    • pp.287-300
    • /
    • 2022
  • Unconventional structures are getting more popular in recent days. Large-span roofs are used for many structures, such as airports, stadiums, and conventional halls. Identifying the pressure distribution and wind load acting on those structures is essential. This paper offers a collaborative study of computational fluid dynamics (CFD) simulations and wind tunnel tests for assessing wind pressure distribution for a building with a combined slender curved roof. The hybrid turbulence model, Improved Delayed Detached Eddy Simulation (IDDES), simulates the open terrain turbulent flow field. The wind-induced local pressure coefficients on complex roof structures and the turbulent flow field around the structure were thus calculated based upon open terrain wind flow simulated with the FLUENT software. Local pressure measurements were investigated in a boundary layer wind tunnel simultaneous to the simulation to determine the pressure coefficient distributions. The results predicted by CFD were found to be consistent with the wind tunnel test results. The comparative study validated that the recommended IDDES model and the vortex method associated with CFD simulation are suitable tools for structural engineers to evaluate wind effects on long-span complex roofs and plan irregular buildings during the design stage.

Evaluation of Applicability on a High-rise Building for the Effective Usage of High Performance Steel for Building Structures (건축구조용 고성능 강재 HSA800의 효율적 사용을 위한 초고층 건물의 적용성 평가)

  • Kim, Do Hwan;Kim, Joo Woo;Lee, Dong Woo;Yang, Jae Guen;Lee, Myung Jae
    • Journal of Korean Society of Steel Construction
    • /
    • v.26 no.5
    • /
    • pp.463-471
    • /
    • 2014
  • As building height and span is getting taller and longer, the researches to increase material's strength and serviceability are continuously performed. This study evaluated mechanical and chemical properties of newly developed high-strength steel (HSS) for building structures, namely HSA800 and verified cost-effectiveness and applicability of HSS for a tall building by comparing the analysis results of normal strength steel (SM490) model. HSA800 was manufactured by TMCP to have a good weldability in spite of HSS and satisfied Korean Industrial Standards (KS). The analysis results for evaluating cost-effectiveness show that total steel quantity could be saved approximately 30% when using HSS compared to SM490. It is expected that HSA800 will contribute to enhance constructability of building.

Vibration Control of Wind Response of Tall Building Using TLD and MTLD (TLD와 MTLD을 이용한 고층건물의 풍응답 진동제어)

  • You, Ki-Pyo;Ko, Nag-Ho;Kim, Young-Moon
    • Journal of Korean Association for Spatial Structures
    • /
    • v.5 no.1 s.15
    • /
    • pp.73-80
    • /
    • 2005
  • Serviceability of buildings is affect by excessive acceleration experienced at the top floors in wind storms that may cause discomfort to the occupants. Tuned liquid damper(TLD) and multiple tuned liquid damper(MTLD) are passive control devices that consists of rigid tank filled with liquid to suppress the vibration of structures. This TLD and MTLD are attributable to several potential advantages - low costs; easy to install in existing structures; effective even for small-amplitude vibrations. In this paper, the behavior of TLD and MTLD are investigated analytically and wind tunnel test of high-frequency force balance.

  • PDF

Aging Coefficient Formula of Reinforced Concrete Members under Axial Compression (축하중을 받는 철근콘크리트 부재의 재령계수식 제안)

  • Yoo, Jae-Wook;Yu, Eun-Jong
    • Journal of Korean Association for Spatial Structures
    • /
    • v.13 no.4
    • /
    • pp.67-74
    • /
    • 2013
  • The Age-adjusted effective Modulus Method(AEMM) is one of the methods adopted for the construction stage analysis of concrete structures. The AEMM uses the aging factor to consider the effects of the varying concrete stress. In the aspects of computation time and the accuracy of the results, the AEMM is considered as one of most appropriate methods for construction stage analysis of tall building structures. Previous researches proposed appropriate values of the aging factor in the forms of graphs or using very simple equations. In this paper, an equation for estimating the aging factor as a function of rebar ratio in the section, compressive strength of concrete, notional member dimension, and age of concrete at the load application. The validity of aging factor proposed in this paper were examined by the comparison with the results of step-by step method.