• Title/Summary/Keyword: Tall building structures

Search Result 343, Processing Time 0.019 seconds

Wind-induced responses and dynamic characteristics of a super-tall building under a typhoon event

  • Hua, X.G.;Xu, K.;Wang, Y.W.;Wen, Q.;Chen, Z.Q.
    • Smart Structures and Systems
    • /
    • v.25 no.1
    • /
    • pp.81-96
    • /
    • 2020
  • Wind measurements were made on the Canton Tower at a height of 461 m above ground during the Typhoon Vincente, the wind-induced accelerations and displacements of the tower were recorded as well. Comparisons of measured wind parameters at upper level of atmospheric boundary layer with those adopted in wind tunnel testing were presented. The measured turbulence intensity can be smaller than the design value, indicating that the wind tunnel testing may underestimate the crosswind structural responses for certain lock-in velocity range of vortex shedding. Analyses of peak factors and power spectral density for acceleration response shows that the crosswind responses are a combination of gust-induced buffeting and vortex-induced vibrations in the certain range of wind directions. The identified modal frequencies and mode shapes from acceleration data are found to be in good agreement with existing experimental results and the prediction from the finite element model. The damping ratios increase with amplitude of vibration or equivalently wind velocity which may be attributed to aerodynamic damping. In addition, the natural frequencies determined from the measured displacement are very close to those determined from the acceleration data for the first two modes. Finally, the relation between displacement responses and wind speed/direction was investigated.

Structural System Selection and Highlights of Changsha IFC T1 Tower

  • Jianlong, Zhou;Daoyuan, Lu;Liang, Huang;Jun, Ji;Jun, Zhu;Jingyu, Wang
    • International Journal of High-Rise Buildings
    • /
    • v.3 no.2
    • /
    • pp.99-106
    • /
    • 2014
  • This paper presents the determination of the structural system of the Changsha IFC T1 tower with 452 m in architectural height and 440.45 m in structural height. Sensitivity analyses are carried out by varying the location of belt trusses and outriggers. The enhancement of seismic capacity of the outer frame by reasonably adjusting the column size is confirmed based on parametric studies. The results from construction simulation including the non-load effect of structures demonstrate that the deformation of vertical members has little effect on the load-bearing capacity of belt trusses and outriggers. The elastoplastic time-history analysis shows that the overall structure under rare earthquake load remains in an elastic state. The influence of the frame shear ratio and frame overturning moment ratio on the proposed model and equivalent mega column model is investigated. It is found that the frame overturning moment ratio is more applicable for judging the resistance of the outer frame against lateral loads. Comparison is made on the variation of these two effects between a classical frame-core tube-outrigger structure and a structure with diagonal braces between super columns under rare earthquakes. The results indicate that plasticity development of the top core cube of the braced structure may be significantly improved.

Case Study of Ancient City Wall Renewal in Gongju, a Historic Cultural City (역사문화도시 공주의 고도담장정비 사례 연구)

  • Ohn, Hyoungkeun
    • Korean Journal of Heritage: History & Science
    • /
    • v.53 no.2
    • /
    • pp.254-269
    • /
    • 2020
  • The purpose of this study is to propose guidance for wall renewal that is appropriate for an ancient city wall through application of advanced research and theories in wall design. It is a streetscape improvement project which forms part of the "Ancient City Image Finding Project". Study methods consist of advanced research classification, wall design theory contemplation, and analysis of the significance of designated ancient city areas and the "Ancient City Image Finding Project" status. Based on these methods, case study candidates were selected, case status and problems were identified, and improvement proposals were analyzed by comparing various features. Advanced wall research was classified into six categories including analysis of wall characteristics; wall design principle applications; wall structure, color, shape, and application; modern reinterpretation; palace walls; and house, temple, and village walls. The wall is an element of the streetscape improvement component of the "Ancient City Image Finding Project", with the characteristic of providing preceding experience in visual and cognitive awareness than interior structure. Case candidates for ancient city wall improvement are based on the composition distribution of the special conservation district in each ancient city as well as the conservation promotion district. Ultimately, the surrounding village of Gongju-si Geumseong-Dong Songsanri-gil, adjacent to the Royal Tomb of King Muryeong, was selected as the candidate. The "Ancient City Image Finding Project" of the surrounding village of Gongju-si Geumseong-Dong Songsanri-gil began with new Hanok construction. However, wall maintenance did not begin concurrently with that new Hanok construction. Support and maintenance took place afterwards as an exterior maintenance project for roadside structures. If the Hanok and wall were evaluated and constructed at the same time, the wall would have been built in unison with the size and design of the Hanok. The layout of the main building and wall of the Hanok is deemed to be a structure that is closed tightly because of its spatial proximity and tall height. Songsan-ri-gil's wall design should create a calm, subtle, and peaceful atmosphere with shapes, colors, and materials that express ancient city characteristics, but it is in an awkward position due to its sharpness and narrowness. The cause of the problem at Gongju-si Geumseong-dong Songsanri-gil, the case candidate, is that it is lacking significantly in terms of the aesthetic factors that traditional walls should possess. First, aesthetic consciousness seems to have disappeared during the selection and application process of the wall's natural materials. Second, the level of completion in design and harmony is absent. Maintenance guidance after analyzing the cause of problems in ancient city wall maintenance at Gongju-si Geumseong-dong Songsanri-gil, the subject area of research, is as follows: First, the Hanok design and layout of the wall and main gate should be reviewed simultaneously. Second, the one-sided use of natural stone wall in the Hanok wall design should be reexamined. Third, a permanent system to coordinate the opinions of citizens and experts during the planning and design phases should be employed. Fourth and finally, the Hanok's individuality shall be collectivized and its value as a cultural asset representing the identity of the community shall be increased.