• 제목/요약/키워드: Tainter gate

검색결과 6건 처리시간 0.017초

배수갑문 테인터 게이트(Tainter Gate)의 진동현상에 관한 모형실험(Ⅱ)- 문비 안에서 밖으로의 흐름 - (Model Tests Study on Flow-induced Vibrationof Tainter Gate in Estuary Sulices(Ⅱ)- Flow from the Gate Inside to the Gate Outside -)

  • 이성행;우상익
    • 한국농공학회논문집
    • /
    • 제46권2호
    • /
    • pp.41-47
    • /
    • 2004
  • A model test is carried out to investigate flow-induced vibration of a Tainter gate in estuary sulices. The gate model scaled with the ratio of 1:25 is made of acryl panel dimensioned 0.66 m in width, 0.5 m in height in the concrete test flume. Firstly, natural frequencies of the model gate are measured and the results are compared with the numerical results in order to verify the model. In the flow from the gate inside to the gate outside, the amplitudes of the vibration are measured under the different gate opening and downstream water level conditions. Also revised gate models with 20 mm bottom width are tested under the different gate openings and water levels. The results are analyzed to study the characteristics of the Tainter gate vibration in the sea ward flow. These test results are assessed in comparison with the results in the lake ward flow, as a result, presents the dynamic characteristics of the Tainter gate and a basic data for the guide manuals of gate management.

배수갑문 테인터 게이트(Tainter Gate)의 진동현상에 관한 모형실험 ( I ) - 문비 밖에서 안으로의 흐름 - (Model Tests Study on Flow-induced Vibration of fainter Gate in Estuary Sulices (I) - Flow from the Gate Outside to the Gate Inside -)

  • 이성행
    • 한국농공학회논문집
    • /
    • 제46권1호
    • /
    • pp.27-34
    • /
    • 2004
  • A model test is carried out to investigate flow-induced vibration of a Tainter gate in estuary sulices. The gate model scaled with the ratio of 1:25 is made of acryl panel dimensioned 0.66m in width, 0.5m in height in the concrete test flume. Firstly, natural frequencies of the model gate are measured and the results are compared with the numerical results in order to verify the model. The amplitudes of the vibration are measured under the different gate opening and water level conditions in flow from the gate outside to the gate inside. Also 5 revised gate models with bottom width increased 0.5 cm each are tested under the different gate opening and water level. The results are analyzed to study the characteristics of the gate vibration. These test results are assessed in comparison with formerly test results, as a result, presents a design method of Tainter gate to reduce the gate vibration and a basic data for the guide manuals of gate management.

테인터수문이 설치된 월류형 여수로에서의 흐름에 대한 수치모의 (A Numerical Simulations on the Flow over Ogee Spillway with Tainter Gate)

  • 김대근;박재현;이재형
    • 한국수자원학회논문집
    • /
    • 제37권8호
    • /
    • pp.675-685
    • /
    • 2004
  • 본 연구에서는 FLOW-3D를 이용하여, 테인터수문이 설치된 표준 월류형 여수로에서 수문을 부분 개방했을 경우에 대한 월류흐름 거동을 해석하였다. 모의결과, 유량계수는 약 0.685에서 0.723의 범위를 가지는 것으로 분석되었다. 수문을 완전 개방한 경우의 월류유량을 이용하여 수문을 부분 개방한 경우의 월류유량을 효과적으로 산정 할 수 있는 방법을 제시하였다. 수문의 개방고와 개방도에 따라 여수로면과 수문에 작용하는 압력분포의 특성을 분석하였다. 일정한 수문 개방고에 대해 수문의 개방도가 감소할수록 그리고 일정한 개방도에 대해 수문의 개방고가 높을수록, 여수로면에서 부압은 크게 발생하며 수문에 작용하는 무차원 최대압력은 증가하는 것으로 분석되었다.

Local zooming genetic algorithm and its application to radial gate support problems

  • Kwon, Young-Doo;Jin, Seung-Bo;Kim, Jae-Yong;Lee, Il-Hee
    • Structural Engineering and Mechanics
    • /
    • 제17권5호
    • /
    • pp.611-626
    • /
    • 2004
  • On the basis of a structural analysis of radial gate (i.e. Tainter gate), the current paper focuses on weight minimization according to the location of the arms on a radial gate. In spite of its economical significance, there are hardly any previous studies on the optimum design of radial gate. Accordingly, the present study identifies the optimum position of the support point for a radial gate that guarantees the minimum weight satisfying the strength constraint conditions. This study also identifies the optimum position for 2 or 3 radial arms with a convex cylindrical skin plate relative to a given radius of the skin plate curvature, pivot point, water depth, ice pressure, etc. These optimum designs are then compared with previously constructed radial gates. Local genetic and hybrid-type genetic algorithms are used as the optimum tools to reduce the computing time and enhance the accuracy. The results indicate that the weights of the optimized radial gates are appreciably lower than those of previously constructed gates.

회전식 수문의 최적 설계 (Optimum Design of Radial Gate)

  • 권영두;권순범;박창규;윤영중
    • 한국전산구조공학회논문집
    • /
    • 제14권3호
    • /
    • pp.267-276
    • /
    • 2001
  • 이 논문은 회전식 수문(radial gate)의 구조해석에 근거하여 지지점 위치에 따른 모멘트 분배를 최적화하는 것에 관심을 두고 있다. 회전식 수문(radial gate)의 경제적인 관점에서의 중요성에도 불구하고 이의 지지점 위치에 따른 최적설계에 관한 자료를 찾기 어려운 실정이다. 그래서 본 연구에서는 주판(skin plate)의 곡률 반경, 수심, 동압 등의 주어진 자료를 이요약하여 지지점(gate arm)의 수가 2개인 경우와 3개인 경우에 대하여 곡선형태의 주판(skin plate)에서 지지점 (arm)의 최적 위치를 얻어서 설계자료에 의한 것들과 비교한다. 그 결과 최적 설계에 의한 회전식 수문 (radial gate)의 치수가 설계자료에 의한 것에 비해 현저히 감소되는 것을 알 수 있다.

  • PDF

트러스형 리프트 게이트의 진동현상에 관한 모형실험 (Model Tests Study on Flow-induced Vibration of Truss Type Lift Gate)

  • 이성행;김하집;박영진;함형길;공보성
    • 한국농공학회논문집
    • /
    • 제53권3호
    • /
    • pp.35-41
    • /
    • 2011
  • A model test is carried out to investigate the vibration of truss type lift gate in the four major rivers project. The gate model scaled with the ratio of 1 : 25 is made of acryl panel dimensioned 1.6 m in width, 0.28 m in height in the concrete test flume. Firstly natural frequencies of the model gate are measured and the results are compared with the numerical results in order to verify the model. The amplitudes of the vibration are measured under the different gate opening and water level conditions. The results are analyzed to study the characteristics of the gate vibration according to the small gate opening, the large gate opening and the overflow conditions. These test results presents a basic data for the guide manuals of gate management and a design method to reduce the gate vibration of truss type lift gate. Finally, the vibration of truss type lift gate are assessed in comparison with those of formerly tainter gate.