The Clinical Experiences of "New Duromedics Valve" Replacement (새로운 Duromedics 인공판막 치환의 임상고찰)

  • Gang, Myeon-Sik;Yu, Gyeong-Jong;Yun, Chi-Sun;Park, Han-Gi
    • Journal of Chest Surgery
    • /
    • v.30 no.10
    • /
    • pp.979-985
    • /
    • 1997
  • Between October 1991 and May 1995, 256 "New Duromedics Valve"(Edward TEKNA Bileaflet Valve) were implanted in 208 adult patients(171 mitral, 82 aortic and 3 tricuspid) with age ranging from 18 years to 70 years(mean 48.2$\pm$ 11.6 years). Postoperative complication rates were 12.2%, but there was none valve related one. Overall early mortality rate were 1.4%(1.6% for MVR, 2.1% for DVR, and none for AVR or TVR) respectively. Follow-up was 99% completed ranging in duration from 2 months to 46 months. There were 6 valve-related late complications(2.9%) with 2 patients with upper gastrointestinal bleeding, 2 with cerebral thxomtioembolism, 1 with valve thrombosis and 1 with valve endocarditis. Freedom from these valve-related major complications were 89.9% at 40 months. There were 5 late deaths(2.4%). one of these late deaths was considered valve-related. Overall actuarial survival rates at 40 months were 95.5%, 96.8% for mitral, 97.1% for aortic, 100% for tricuspid, and 92.0% for double valve replacement respectively. Preoperative New York Heart Association functional class were 2.9, and 1.3 in post-operative state. We have been trying to keep the international normalized ratio(INR) with range of 2.5 to 3.0. The INR of 4 patients of 5 with anticoagulant ralated complications was beyond the range. To reduce the rate of anticoagulant related complications, we felt very strongly that the INR should be kept between 2.5 and 3.0. In our cases, there was no structural failure or significant hemolysis in the absence of periprosthetic leak. This experience encourages us to continue using the "New Duromedics Valve".omedics Valve".uot;.

  • PDF

Ten Years Experiences of ATS Mechanical Valve (ATS 기계 판막의 10년 임상경험)

  • Yi, Gi-Jong;Bae, Mi-Kyung;Lim, Sang-Hyun;Yoo, Kyung-Jong;Chang, Byung-Chul;Hong, You-Sun
    • Journal of Chest Surgery
    • /
    • v.39 no.12 s.269
    • /
    • pp.891-899
    • /
    • 2006
  • Background: This study is to evaluate the safety of ATS valve by examining the clinical results of ten-years experience. Material and Method: From July 1995 to March 2005, we reviewed 305 patients with ATS valve implantation. Mean age was $49.8{\pm}11.7$ years and 140(45.6%) males were included. Etiologies were rheumatic diseases in 207 cases(67.4%), degenerative changes in 57 cases(18.6%), valve dysfunction in 23 cases(7.5%) and infective endocarditis in 14 cases(4.6%). AVR was performed in 72 patients(23.5%), MVR in 156 patients (50.8%), DVR(AVR+MVR) in 63 patients(20.5%) and TVR in 16 patients(5.2%). Result: There were 9 operative mortalities(2.9%). Follow up period was $56.5{\pm}34.0(0{\sim}115)$ months and 96.4% patients were followed up with 9 late deaths. Five and ten years survival rates were $94.9{\pm}1.3%,\;91.2{\pm}2.3%$ using Kaplan-Meier's methods. Valve related event free survival rates in 5 and 10 years were $90.8{\pm}2.0%$ and $86.9{\pm}3.2%$. There were 16 anticoagulation-related hemorrhages, 6 thromboembolisms, 3 prosthetic valve endocarditis and 1 paravalvular leakage. NYHA class improved after operation(p<0.05). Postoperative echocardiography showed significant decrease in LA size, LVEDD and IVESD(p<0.01). Patients with 19 and 21 mm valve showed significantly higher transvalvular pressure gradient in aortic position(p<0.001, p<0.001). Conclusion: ATS valve showed good hemodynamic results with few valve related complications and thus can be used with acceptable risk.

Clinical Experiences of Open Heart Surgery (개심술(開心術) 2,000례의 임상적 고찰)

  • 김하늘루;박경택;곽기오;한일용;소영환;최강주;이양행;조광현
    • Journal of Chest Surgery
    • /
    • v.31 no.12
    • /
    • pp.1183-1194
    • /
    • 1998
  • Background: From Sept. 1985 to Sept. 1997, 2,000 cases of open heart surgery(OHS) were performed in the Department of Thoracic & Cardiovascular Surgery, Pusan Paik Hospital, College of Medicine, Inje University. Material and Method: Among the total of 2,000 cases of OHS, 1532 cases were congenital heart disease(CHD) and 468 cases were acquired heart disease(AHD). The age distribution was 9 days(4.0kg) to 68 years in CHD and 11 to 66 years in AHD. In 1532 cases of CHD, there were 1403 acyanotic cases and 129 cyanotic cases. Result: The CHD cases consisted of 940 ventricular septal defects(61.4%), 324 atrial septal defects(21.1%), 112 tetralogy of Fallot(7.3%), 46 pulmonary stenosis(3%), 38 endocardial cushion defects(2.5%), 15 valsalva sinus ruptures(1%), 4 transposition of great arteries (0.3%), 4 double outlet right ventricles(0.3%), and etc. Corrective operations were applied for congenital heart disease with a result of 3.1% hospital mortality. Of 468 AHD, 381 cases were valvular heart diseases, 48 ischemic heart diseases, 12 cardiac tumors, 8 annuloaortic ectasias, 16 dissecting aortic aneurysms and etc. In the 381 valvular heart diseases, there were 226 single valve replacements(36 aortic valve replacements(AVR), 188 mitral valve replacements(MVR), and 2 tricuspid valve replacements(TVR), among these were 71 cases of double valve replacements(AVR & MVR), 54 cases of MVR with tricuspid valve annuloplasty(TVA), and 18 cases of AVR, MVR with TVA. The total implanted prosthetic valves were 466. In MVR, 123 St. Jude Medical valves, 90 Carpentier-Edwards valves, 65 CarboMedics valves, 42 Sorin valves and 16 other valves were used. In AVR, 68 St. Jude Medical valves, 36 CarboMedics valves, 14 Carpentier-Edwards valves and 9 other valves were used. Coronary Artery Bypass Surgery(CABG) were performed in 48 cases. The patterns of bypass graft were 14 patients of single vessel graft, 21 patients of two vessels graft, 10 patients of three vessels graft and 3 patients of four vessels graft. Conclusion: The hospital operation mortality rate of congenital acyanotic, cyanotic and acquired heart diseases were 2.0%, 15.5%, and 5.1% respectively. The overall mortality rate was 3.6%(72/2,000).

  • PDF

The Long-term Clinical Result of St. Jude Mechanical Valve Replacement (St. Jude 기계판막 치환술의 장기 임상성적)

  • 배윤숙;정성철;김우식;정승혁;유환국;이정호;김병열
    • Journal of Chest Surgery
    • /
    • v.36 no.5
    • /
    • pp.321-328
    • /
    • 2003
  • Background: The St. Jude Medical prosthesis is one of the popularly used artificial prosthesis, therefore the National Medical Center reports the long-term clinical results of patients who underwent prosthetic valve replacement with St. Jude medical valve for 18 years. Material and Method: Between January, 1984 and June, 2002, a series of 163 consecutive patients who had Implanted St. Jude prosthesis at the National Medical Center were reviewed. Mean age was 42.9$\pm$15.1 years and male to female ratio was 69:94. The operative procedure comprised of 87 MVR, 30 AVR, 45 DVR, and 1 TVR. The reoperative procedure comprised of 21 MVR, 2 AVR, and 14 DVR. Follow-up rate was 96.9%, and cumulative follow-up was 823.8 patient-years. Result: Early mortality rate was 7.9% (13 patients), late mortality rate was 8.7% (13 patients) and late mortality due to valve related complication was 47% (7 patients). Actual survival rate at 10 and 18 years were 91.7$\pm$2.1% and 91.0$\pm$1.9%. Linearized Incidence was as follows: thromboembolism, 1.09%/ patient-year; anticoagulant related hemorrhage, 0.36%/patient-year; valve thrombosis, 0.24%/patient-year; paravalvular leakage, 0.12%/patient-year; and prosthetic bacterial endocarditis, 0.12%/patient-year linearized incidence of over all valve related complication was 1.94%/patient-year. Freedom from valve related complication at 10 and 18 years were 89.1$\pm$3.3% and 88.4$\pm$3.9%. Freedom from valve related death at 10 and 18 years were 95.1$\pm$1.2% and 95.1$\pm$1.0%. Valve related complication was related the age of patient, especially anticoagulant related hemorrhage was more common in patients over 60 years of age. Valve related complication, death were higher in DVR than AVR or MVR, and valve related death was higher in reoperation. There was no relationship between valve related complication or death and implant valve of size. Conclusion: The long-term clinical results of patients implanted with St. Jude Mechanical prosthesis was quite satisfactory with a low incidence of valve related complication and mortality.

Operative Treatment of Congenitally Corrected Transposition of the Great Arteries(CCTGA) (교정형 대혈관 전위증의 수술적 치료)

  • 이정렬;조광리;김용진;노준량;서결필
    • Journal of Chest Surgery
    • /
    • v.32 no.7
    • /
    • pp.621-627
    • /
    • 1999
  • Background: Sixty five cases with congenitally corrected transposition of the great arteries (CCTGA) indicated for biventricular repair were operated on between 1984 and september 1998. Comparison between the results of the conventional(classic) connection(LV-PA) and the anatomic repair was done. Material and Method: Retrospective review was carried out based on the medical records of the patients. Operative procedures, complications and the long-term results accoding to the combining anomalies were analysed. Result: Mean age was 5.5$\pm$4.8 years(range, 2 months to 18years). Thirty nine were male and 26 were female. Situs solitus {S,L,L} was in 53 and situs inversus{I,D,D} in 12. There was no left ventricular outflow tract obstruction(LVOTO) in 13(20%) cases. The LVOTO was resulted from pulmonary stenosis(PS) in 26(40%)patients and from pulmonary atresia(PA) in 26(40%) patients. Twenty-five(38.5%) patients had tricuspid valve regurgitation(TR) greater than the mild degree that was present preoperatively. Twenty two patients previously underwent 24 systemic- pulmonary shunts previously. In the 13 patients without LVOTO, 7 simple closure of VSD or ASD, 3 tricuspid valve replacements(TVR), and 3 anatomic corrections(3 double switch operations: 1 Senning+ Rastelli, 1 Senning+REV-type, and 1 Senning+Arterial switch opera tion) were performed. As to the 26 patients with CCTGA+VSD or ASD+LVOTO(PS), 24 classic repairs and 2 double switch operations(1 Senning+Rastelli, 1 Mustard+REV-type) were done. In the 26 cases with CCTGA+VSD+LVOTO(PA), 19 classic repairs(18 Rastelli, 1 REV-type), and 7 double switch operations(7 Senning+Rastelli) were done. The degree of tricuspid regurgitation increased during the follow-up periods from 1.3$\pm$1.4 to 2.2$\pm$1.0 in the classic repair group(p<0.05), but not in the double switch group. Two patients had complete AV block preoperatively, and additional 7(10.8%) had newly developed complete AV block after the operation. Other complications were recurrent LVOTO(10), thromboembolism(4), persistent chest tube drainage over 2 weeks(4), chylothorax(3), bleeding(3), acute renal failure(2), and mediastinitis(2). Mean follow-up was 54$\pm$49 months(0-177 months). Thirteen patients died after the operation(operative mortality rate: 20.0%(13/65)), and there were 3 additional deaths during the follow up period(overall mortality: 24.6%(16/65)). The operative mortality in patients underwent anatomic repair was 33.3%(4/12). The actuarial survival rates at 1, 5, and 10 years were 75.0$\pm$5.6%, 75.0$\pm$5.6%, and 69.2$\pm$7.6%. Common causes of death were low cardiac output syndrome(8) and heart failure from TR(5). Conclusion: Although our study could not demonstrate the superiority of each classic or anatomic repair, we found that the anatomic repair has a merit of preventing the deterioration of tricuspid valve regurgitations. Meticulous selection of the patients and longer follow-up terms are mandatory to establish the selective advantages of both strategies.

  • PDF

Off-pump Coronary Artery Bypass Surgery Versus Drug Eluting Stent for Multi-vessel Coronary Artery Disease (다혈관 관상동맥질환에서의 심폐바이패스를 사용하지 않은 관상동맥우회술과 약물용출 스텐트시술)

  • Lee, Jae-Hang;Kim, Ki-Bong;Cho, Kwang-Ree;Park, Jin-Shik;Kang, Hyun-Jae;Koo, Bon-Kwon;Kim, Hyo-Soo;Sohn, Dae-Won;Oh, Byung-Hee;Park, Young-Bae
    • Journal of Chest Surgery
    • /
    • v.41 no.2
    • /
    • pp.202-209
    • /
    • 2008
  • Background: The introduction of Drug Eluting Stents (DES) decreased the number of patients referred for coronary artery bypass grafting (CABG). The impact of DES on CABG (Step 1) was studied and compared with the 1-year outcome after CABG with DES (Step 2). Material and Method: Surgical results for patients who underwent off-pump CABG (OPCAB) before the introduction of DES(n=298) were compared with those who underwent OPCAB after the introduction of DES (n=288) (Step 1). Postoperative 30-day and 1-year results were also compared between the patients who underwent percutaneous coronary intervention (PCI) using DES (n=220) and those who underwent OPCAB (n=255) (Step 2). Result: Since the introduction of DES, the ratio of CABG versus PCI decreased. In the CABG group, the number of high risk patients such as elderly patients (age 62 vs. 64, p=0.023), those with chronic renal failure (4% vs. 9%, p=0.021), calcification of the ascending aorta (9% vs. 15%, p=0.043), or frequency of urgent or emergent operations (12% vs. 22%, p=0.002) increased. However, there were no differences in the cardiac death and graft patency rates between the two groups (step 1). During the one-year follow up period, the rate of target vessel revascularization (12.3% vs. 2.4%, p<0.001) and major adverse cardiac events (MACE: death, myocardial infarct, TVR) were higher in the DES than the CABG group (13.6% vs 4.3%) (stage 2). Conclusion: Introduction of DES decreased the number of patients referred for surgery, and increased the comorbidity in patients who underwent CABG. DES increased the rate of target vessel revascularization, and the occurrence of MACE during the 1-year follow-up. However, there was no difference in the incidence of myocardial infarction and cardiac death between the two groups.