• Title/Summary/Keyword: TT system

Search Result 137, Processing Time 0.022 seconds

Evaluation of Performance and Development of Control Method of a New Electric Power Steering System(EPS-TT) (새로운 전동식 동력 조향 장치 (EPS-TT)의 성능 평가 및 제어방법 개발)

  • 송정훈;부광석;이종일
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.12 no.5
    • /
    • pp.154-161
    • /
    • 2004
  • A new column type electric power steering system (EPS-TT) is proposed in this study. The remarkable features of EPS-TT are its opto-isolated torque sensor and assist torque control methodology. EPS-TT uses a uni-directional motor and two clutches. Full order and simplified models for EPS-TT are developed to evaluate the EPS-TT. A full car model is also used to investigate the vehicle responses. A PID control logic is designed to control the torque of the assist motor. Various sinusoidal inputs are applied to the system and the resulting performances are analyzed. The results prove that the performances achieved by the EPS-TT are improved compared to those of a conventional EPS-TT across the frequency domain. In addition, it is inexpensive and easy to control the motor. The results of the full order steering system model are similar to those simplified model, but the vehicle responses are slightly different.

Evaluation of the Protection Performance of TT and TN Systems for Low-Voltage Consumers Against Lightning Surges (저압수용가에 공급하는 TT, TN계통의 뇌서지에 대한 보호성능의 평가)

  • Lee, Kyu-Sun;Choi, Jong-Hyuk;Lee, Bok-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.6
    • /
    • pp.67-74
    • /
    • 2010
  • Most of domestic low-voltage consumers are supplied from the TN-C system of KEPCO, but their load installations have established according to the national statutory standard for electrical installations based on the TT system. In this work, to propose the proper system earthing arrangements of ensuring the protection of information-technology equipment against lightning surges, the protection performance of TT and TN systems against lightning surges was investigated. As a result, when lightning surge was injected to the neutral line of distribution system, the potential difference between the equipment earth terminal and neutral point of low-voltage mains in a TT system was significantly raised. The TT system is not advised due to the risk of damage to the sensitive computer equipment. Main equipotential bonding is an important requirement for protection of low-voltage installations against lightning surges. The TN system provides the best means to reduce the incoming lightning surges through the neutral line of low-voltage service systems. In addition, It is highly recommended to install the additional earthing at the service position of low-voltage consumers.

A Study on the CDMA-based TT&C Design and Experiment Concept

  • Lee, Ho-Jin;Mo, Hee-Sook
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1999.10a
    • /
    • pp.37-40
    • /
    • 1999
  • ETRI has successfully completed and delivered to KARI the KOMPSAT Mission Control System. This system was designed to work in the conventional TT&C modulation scheme with the pre-assigned frequencies. As a way to accelerate in catching up with future TT&C technology evolutions, a preliminary study needs to be carried out to prepare for the development of a spread spectrum applicable to TT&C. A brief study was carried out to review some points to be considered in designing and implementing spread spectrum schemes to the ground TT&C system intended for a LEO spacecraft. Also a simulation and link design revisit was performed to see the operational and technical benefits with the KOMPSAT TT&C parameters. An experiment concept is proposed to test as many functions at a time once the prototype is developed. In this configuration, a ground-model TT&C transponder is connected via LAN to the ETRI-developed KOMPSAT S/W simulator and linked to the KOMPSAT TM/TC processing s/w via spread spectrum signals through a GEO satellite bent-pipe link. A satellite data relay link simulation could be carried out in this configuration.

  • PDF

Interference analysis on Japanese radio source for KOMPSAT TT&C ground system

  • Park, Durk-Jong;Ahn, Sang-Il
    • Bulletin of the Korean Space Science Society
    • /
    • 2008.10a
    • /
    • pp.36.2-36.2
    • /
    • 2008
  • This paper presents the impact of Japanese radio source on the S-Band communication between KOMPSAT-2 satellite and TT&C ground system. Major specifications such as transmitting EIRP (Effective Isotropic Radiated Power) and location of Japanese terrestrial station were informed from Radio Research Laboratory in Korea Communication Commission. To estimate path loss in S-Band, the distance between Japanese station and TT&C ground system was obtained by using COTS (Commercial Off-The-Shelf) software. After that the signal strength of Japanese radio source placed at the TT&C ground system was calculated from link parameters such as transmitting EIRP, path loss, and receiving antenna gain. Consequently, this paper shows that the degradation caused by Japanese radio source is acceptable to TT&C ground system for satellite operation.

  • PDF

Performance Evaluation of Protection against Electric Shocks for TT and TN Systems (TT, TN접지계통의 감전보호 성능평가)

  • Lee, Bok-Hee;Choi, Young-Chul;Yoo, Jae-Duk;Shin, Hee-Kyung;Yang, Soon-Man;Kim, Tae-Gi;Lee, Zu-Cheul
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.10a
    • /
    • pp.315-318
    • /
    • 2009
  • Electric shock is the accident caused by the current through a person or animal's body. That is characterized by the physiological effects. In this paper, we evaluate performance of protection against electric shocks for TT and TN grounding systems which are used by a low voltage consumer nowadays. The performance of protection against electric shocks for TT grounding system is very excellent in equipotential area of the third class grounding, but the performance is poor outside the equipotential area. The performance of protection against electric shocks for TN grounding system is excellent because the potential difference is less than 50V. Accordingly, the performance of protection for TN grounding system is good as compared with that for TT grounding System.

  • PDF

The Comparison and Analysis about Earth System based on IEC60364 (IEC 60364 기반 접지계통 비교 분석)

  • Jung, Jin-Soo;Han, Woon-Ki;Kim, Oh-Hwan;Kim, Jae-Chul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.1
    • /
    • pp.56-62
    • /
    • 2010
  • This paper describes the analysis of loop impedance characteristics by impedance alteration of protective conductors and operating characteristics of electric leakage circuit breaker by each earth systems(TT system, TN-S system and TN-C system) in IEC 60364. As a result, loop Impedance was affected by resistance & inductance. The current& voltage characteristics about earth system were identified that the TN-S system was high fault current & low touch voltage. TN-C system was almost same the TN-S system but TT system was low fault current & high touch voltage.

Development of a Prototype New Electric Power Steering (EPS) System (Prototype의 새로운 Electric Power Steering (EPS) System의 개발)

  • Song Jeong-Hoon
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.30 no.6 s.249
    • /
    • pp.684-690
    • /
    • 2006
  • This study proposes and validates a new column type electric power steering system (EPS-TT). It is driven by a uni-directional motor and two electro-magnetic clutches. The assist motor produces assist torque in only one direction and two clutches transmit the torque to the column of steering system in either left or right direction with respect to the steering input. A full order and a reduced order models are developed to evaluate the EPS-TT. Models are also used to investigate the vehicle responses. A PID control logic is designed to control the torque of the assist motor. A driver model is applied to the system and the resulting performances are analyzed. The results show that the performances of the full order model are similar to those of reduced order model. The results also prove that the performances achieved by the EPS-TT are improved compared to those of a conventional EPS-TT across the frequency domain.

TT&C Antenna Design for LEO Satellite (저궤도 위성용 TT&C 안테나의 설계)

  • Lee, Kwang-Jae;Woo, Duk-Jae;Lee, Taek-Kyung;Lee, Jae-Wook;Lee, Woo-Kyung
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.21 no.6
    • /
    • pp.642-650
    • /
    • 2010
  • In this paper, we study a TT&C link to obtain a required specifications of TT&C(Telemetry Tracking and Command system) antenna for an LEO(Low Earth Orbit) satellite. The premised mission orbit is the sun-synchronized and circular orbit and it performs earth-space observations. We design minimum TT&C link-budget to obtain required antenna beamwidth and gain. The proposed turnstile antenna provides wide beamwidth and circular polarization. We suggested the attaching position that shows the most effective results by confirming the variation of antenna performance when the proposed antenna is adapted to satellite's various positions. Also we proved the proposed antenna's ability while it is performing the mission through the orbit simulation based on the electrical performance of the proposed turnstile antenna.

Touch TT: Scene Text Extractor Using Touchscreen Interface

  • Jung, Je-Hyun;Lee, Seong-Hun;Cho, Min-Su;Kim, Jin-Hyung
    • ETRI Journal
    • /
    • v.33 no.1
    • /
    • pp.78-88
    • /
    • 2011
  • In this paper, we present the Touch Text exTractor (Touch TT), an interactive text segmentation tool for the extraction of scene text from camera-based images. Touch TT provides a natural interface for a user to simply indicate the location of text regions with a simple touchline. Touch TT then automatically estimates the text color and roughly locates the text regions. By inferring text characteristics from the estimated text color and text region, Touch TT can extract text components. Touch TT can also handle partially drawn lines which cover only a small section of text area. The proposed system achieves reasonable accuracy for text extraction from moderately difficult examples from the ICDAR 2003 database and our own database.

Modeling and Implementation of Safety Test Device for Grounding System Based on IEC 60364 (IEC 60364의 접지방식에 기반한 안전성 평가 시험장치의 모델링 및 구현에 관한 연구)

  • Kim, Soon-Sik;Han, Byeong-Gill;Lee, Hu-Dong;Ferreira, Marito;Rho, Dae-Seok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.6
    • /
    • pp.599-609
    • /
    • 2021
  • A novel grounding system, which is presented in IEC 60364, has been adopted since 2021. A safety evaluation for the human body on the grounding system is required due to the various characteristics of the touch voltage and current passing when the human body experiences an electric shock. The Korea Electrical Safety Corporation (KESCO) and Korea Electric Association (KEA) have been conducting a safety technical education on the grounding system. On the other hand, it is difficult to instruct the electrical safety manager because of a lack of safety evaluations for the test equipment on the grounding system. Therefore, this paper modeled and implemented a test device for a safety evaluation depending on the grounding system of IEC 60364. Namely, this paper presents the modeling of the test device for a safety evaluation using PSCAD/EMTDC S/W, which is composed of an AC grid section, s test device section on the grounding system, and a sub-device section. This paper implemented a test device for safety evaluation, which consisted of an AC grid section, TT grounding system section, TN-S grounding system section, and monitoring section. From the simulation and test results with the safety characteristics of the human body in the TT and TN-S grounding system, when the fault impedances are 0[Ω], 10[Ω], and 100[Ω], the currents passing through the human body in the TT grounding system are 104[mA], 87.4[mA], and 35.5[mA], respectively. The corresponding currents in the TN-S grounding system are 54.9[mA], 4.1[mA], and 0.4[mA], respectively. Based on the results, the protection performance for an electric shock to the human body in the TN-S system is better than the TT system. This can be improved when the existing grounding system is changed from the TT system to the TN-S system.