• Title/Summary/Keyword: TR test

Search Result 288, Processing Time 0.026 seconds

Appicability Evaluations of Dam Breach Floodwave Models (댐 붕괴 수치모형에 대한 적용성 평가)

  • Han, Geon-Yeon;Lee, Jae-Yeong
    • Journal of Korea Water Resources Association
    • /
    • v.31 no.2
    • /
    • pp.189-198
    • /
    • 1998
  • Five dam-break floodwave models are t재 field data sets. The models included FLDWAV, SMPDBK, HEC-1, Tr66, and HEC Dimensionless Graph. The field data sets documented the disasters at Teton dam, and Yeunchun dam. The FLDWAV results are uesd to test the sensitivity of the floodwave to variations in Manning's roughness coefficient, breach size, and bottom slope. The HEC-1 analysis includes testing the sensitivity of the results to model parameters. The TR66 model and FLDWAV, with channel routing by TR66 in both cases. SMPDBK and the Dimensionless Graph procedure are applied without particular difficulties being encountered in both real world cases. It is necessary to analyze numerical limit of existing numerical models and then to apply the relatively accurate numerical model in real basin. It is found that FLDWAV model is superior in numerical accuracy and stability to any other model. This study will contribute to improve defect of numerical models and develop more precise numerical model for a efficient and rapid dam breach flood disaster predict.

  • PDF

Comparisons of Abdominal Muscles Thickness During Single Leg Holding Exercise on Stable Surface and on a Foam Roller Using Ultrasound Imaging (안정된 면과 폼 롤러 위에서 한 발 들기 자세 시 초음파를 이용한 복근들의 두께 양상 비교)

  • Jung, Do-Young;Koh, Eun-Kyung;Kim, Su-Jeong;Kwon, Oh-Yun
    • Korean Journal of Applied Biomechanics
    • /
    • v.20 no.4
    • /
    • pp.415-420
    • /
    • 2010
  • The purpose of this study was to compare the thickness of the abdominal muscles during single leg holding exercise (SLH) in a hooked lying position on stable surface and on a foam roller. Healthy twenty subjects who had no medical history of lower extremity or lower back pain were recruited for this study. Muscle thickness of transverse abdominis (TrA), internal oblique (IO), and external oblique (EO) was recorded using real-time ultrasonography during SLH. Paired t-test with Bonferroni adjustment was used to compare the muscles thickness during SLH on stable surface and on a foam roller. The result showed that TrA and IO muscle demonstrated greater thickness during SLH on foam roller than those on the stable surface. This finding suggests that SLH on an unstable foam roller is more effective to increase thicknesses of TrA and IO muscles than stable surface.

Array Error Analysis and Correction of Active Array Antenna for AESA Radar (AESA 레이더 능동위상배열 안테나의 배열오차 분석 및 보정)

  • Lee, YuRi;Kim, JongPil;Kang, Yeonduk;Kim, SunJoo
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.26 no.4
    • /
    • pp.414-423
    • /
    • 2015
  • Array error analysis and correction of active array antenna are described in this paper. Array elements composed of radiator and TR(Transmit & Recive) module have error(magnitude and phase difference among array elements) which affects SLL(Side Lobe Level). Error affectedness level depends on ideal SLL according to antenna aperture weighting, number of array elements and antenna effective aperture. To satisfy required SLL, correction of array elements is necessary; adopted differently per errors, and weighted differently per shapes of antenna and required SLL. Errors of every individual element had been defined, performance of the antenna with or without error correction had been estimated and proved through near field test.

The Effect of Mechanical Horseback-Riding Training according to Velocity on Trunk Muscles Thickness in Healthy Adult

  • Lim, Jae-Heon;Cho, Woon-Su;Park, Jang-Sung
    • The Journal of Korean Physical Therapy
    • /
    • v.27 no.5
    • /
    • pp.281-286
    • /
    • 2015
  • Purpose: The study was to determine whether mechanical horseback-riding training according to velocity may improve trunk muscles thickness in healthy adults. Methods: Twenty healthy adults participated in this study. The subjects were divided into 2 groups as follows: 10 subjects in high velocity mechanical horseback-riding training (MHRT) and 10 subjects in low velocity MHRT. Subjects in all groups performed a total of 18 sessions 3 times a day for 20 minutes and this experiment lasted for 6 weeks. Mann-Whitney and Wilcoxon Signed Rank test were used in analysis the results of trunk muscle thickness. Ultrasonography was performed to evaluate for thickness of rectus abdominis (RA), external oblique (EO), internal oblique (IO), transverse abdominis (TrA), erector spine (ES), and multifidus (MF) in trunk muscles. Results: Results on the changes of EO, IO, and ES of high velocity MHRT showed a significant increase after 6 weeks (p<0.05). Regarding the changes of EO, IO, ES, TrA, and MF of low velocity MHRT, a significant increase was observed after 6 weeks (p<0.05). The differences in change of trunk muscle thickness before training, after 6-week training between groups, TrA and MF of low velocity MHRT were significantly higher (p<0.05). Conclusion: Based on the results of the current study, the velocity of MHRT was shown to affect change of trunk muscle thickness in healthy adults. In particular, low velocity MHRT may serve as a useful method to provide for TrA, MF thickness improvement related to trunk stabilizers.

A Study of Over Voltage Ground Relay Operation Status at Opening of No-load Charged Cable (무부하 충전케이블 개방시 잔류전압에의한 과전압계전기 동작현상 연구)

  • Kim, Yeong-Han;Choi, Jong-Hyuck;Yoon, Ki-Seob
    • Proceedings of the KIEE Conference
    • /
    • 2000.07a
    • /
    • pp.185-187
    • /
    • 2000
  • Fault current is flowed into 154/23kV M. Tr when line-to-ground fault occurs in power system. NGR(Neutral Grounded Reactor) is set up in order to prevent M.Tr fault by limiting magnitude of fault currents. Here, disconnection of NGR causes voltage increase by L-C resonance and line-to-ground fault in an unearthed system results in voltage increase at healthy phases. So Over Voltage Ground Relay(OVGR) is used for tripping M.Tr. Also, buses at second phases of M.Trs are all connected with section circuit breakers closed for the purpose of parallel operation and load shedding. In case of speciality buses are comprised of power cable in part for GIS connection. When no-load charged cable or bus is open by a section CB, unbalanced voltage charged on the bus is induced. Also discrepant opening time for circuit breakers on different phases gives rise to unbalanced zero sequence voltage. It was observed that this zero sequence voltage detected in the 22.9kV P.T (Potential Transformer for bus) mal-operated 59GT and tripped M.Tr. The zero sequence voltage of which vanishing time is longer than relay operating time came out by EMTDC simulation. Also, it was shown that the voltage waves of actual test are similar to those of simulation. On the basis of above results, R-C circuit complement on the relay without any effect on a power system made operating time of the relay longer than vanishing time of distorted waves. Consequently, operating time of the relay was delayed and magnitude of distorted waves was decreased by increasing time constant of the relay.

  • PDF

Evaluation of the fabrications and properties of ultra-thin film for memory device application (메모리소자 응용을 위한 초박막의 제작 및 특성 평가)

  • Jeong, Sang-Hyun;Choi, Haeng-Chul;Kim, Jae-Hyun;Park, Sang-Jin;Kim, Kwang-Ho
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.06a
    • /
    • pp.169-170
    • /
    • 2006
  • In this study, ultra thin films of ferroelectric vinylidene fluoride-trifluoroethylene (VF2-TrFE) copolymer were fabricated on degenerated Si (n+, $0.002\;{\Omega}{\cdot}cm$) using by spin coating method. A 1~5 wt% diluted solution of purified vinylidene fluoride-trifluoroethylene (VF2:TrFE=70:30) in a dimethylformamide (DMF) solvent were prepared and deposited on silicon wafers at a spin rate of 2000~5000rpm for 30 seconds. After annealing in a vacuum ambient at $200^{\circ}C$ for 60 min, upper gold electrodes were deposited by vacuum evaporation for electrical measurement. X-ray diffraction results showed that the VF2-TrFE films on Si substrates had $\beta$-phase of copolymer structures. The capacitance on $n^+$-Si(100) wafer showed hysteresis behavior like a butterfly shape and this result indicates clearly that the dielectric films have ferroelectric properties. The typical measured remnant polarization (2Pr) and coercive filed (EC) values measured using a computer controlled a RT-66A standardized ferroelectric test system (Radiant Technologies) were about $0.54\;C/cm^2$ and 172 kV/cm, respectively, in an applied electric field of ${\pm}0.75\;MV/cm$.

  • PDF

Optimization of Number of Training Documents in Text Categorization (문헌범주화에서 학습문헌수 최적화에 관한 연구)

  • Shim, Kyung
    • Journal of the Korean Society for information Management
    • /
    • v.23 no.4 s.62
    • /
    • pp.277-294
    • /
    • 2006
  • This paper examines a level of categorization performance in a real-life collection of abstract articles in the fields of science and technology, and tests the optimal size of documents per category in a training set using a kNN classifier. The corpus is built by choosing categories that hold more than 2,556 documents first, and then 2,556 documents per category are randomly selected. It is further divided into eight subsets of different size of training documents : each set is randomly selected to build training documents ranging from 20 documents (Tr-20) to 2,000 documents (Tr-2000) per category. The categorization performances of the 8 subsets are compared. The average performance of the eight subsets is 30% in $F_1$ measure which is relatively poor compared to the findings of previous studies. The experimental results suggest that among the eight subsets the Tr-100 appears to be the most optimal size for training a km classifier In addition, the correctness of subject categories assigned to the training sets is probed by manually reclassifying the training sets in order to support the above conclusion by establishing a relation between and the correctness and categorization performance.

A Study on Hot Straining Embrittlement of Subcritical HAZ in Steel Weldments (강 용접 열영향부 취화역 의 열변형취화 에 관한 연구)

  • 정세희;김태영;임재규
    • Journal of Welding and Joining
    • /
    • v.3 no.2
    • /
    • pp.35-41
    • /
    • 1985
  • The fracture toughness of subcritical HAZ in the hot strained weldments of two structural steels(SB 41 and SA 537) has been investigated by COD test method and metallurgical study. The obtained results are summarized as follows; 1. The hot straining embitterment of subcritical HAZ depends on the hot straining amounts of notch tip, and the transition temperature( $T_{tr}$ ) increases with the accumulated hot straining amounts(.SIGMA. vertical bar .delta.$_{t}$vertical bar). 2. The fracture toughness of subcritical HAZ depends on materials and microstructure. The transition temperature( $T_{tr}$ ) of subcritical HAZ in SB 41 is almost same as that of parent material, however in SA 537 the temperature is higher than that of parent and lower than that of transformed HAZ. 3. The subcritical HAZ in SA 537 shows a higher toughness at small amounts of hot straining (.SIGMA. vertical bar .delta. $_{t}$vertical bar<0.3mm).mm).

  • PDF

Shear Capacity of Precast Concrete Triple Ribs Slab (프리캐스트 콘크리트 트리플 리브 슬래브의 전단성능)

  • Hwang, Seung-Bum;Seo, Soo-Yeon;Lee, Kang-Cheol;Lee, Seok-Hyun
    • Journal of the Korea Concrete Institute
    • /
    • v.28 no.4
    • /
    • pp.489-496
    • /
    • 2016
  • Recently, a concern about hollow core precast concrete (PC) slab has been increased as a method to improve the construction ability by reducing the self weight of structures during the construction. Hollow core slab which is known as a typical PC slab in domestic construction of PC building has a problem to put shear reinforcements in the web of element during the production of element in the factory. With regard to this point, recently, tripple ribs slab (TRS) which can be said as a new type of half PC slab system was developed. In TRS, it is possible to place shear reinforcements in PC element during the production of the element in the factory. This paper presents the shear test result of TRS which was done by one point loading test under simple support condition. Test parameters are the presence of cast-in-place (CIP) concrete and the contribution of lattice bars. From the test, it was found that the TRS has sufficient shear capacity to resist the design load and its strength can be predicted by the code equations for general beam. It is recommended to ignore the strength of lattice bar in the calculation of shear strength during the construction since its contribution is too low to be considered when CIP is not casted.

Characterization of Test Substance in the GLP (GLP 시험에서의 시험물질 특성파악)

  • Lee, Eun-Jung;Song, Kyung-Seuk;Yu, Il-Je
    • Toxicological Research
    • /
    • v.23 no.2
    • /
    • pp.173-177
    • /
    • 2007
  • The GLP contains specific language concerning characterization of the test, control and reference substances used in toxicity studies. This paper will describe and discuss what types of documents are required to support test/reference substance characterization under GLP system. The purpose of this article is to present an overview of data needed in the characterization package that will adequately define the substance. Most sponsors use a certificate of analysis (COA) to communicate the test sub-stance characterization status information to the contracting research organizations. The COA should provide the test $material^{\circ}{\phi}s$ characterization results, substance storage requirements, expiration dates, verification of the collection of the retention sample, archival location of the data to support the characterization and GLP compliance status of the characterization.