• Title/Summary/Keyword: TPH Soxhlet extraction

Search Result 2, Processing Time 0.018 seconds

Comparison of Extraction Methods for the Analysis of Total Petroleum Hydrocarbons in Contaminated Soil (오염토양내 석유계 총탄화수소 분석을 위한 추출방법의 비교)

  • Eui-Young Hwang;Wan Namkoong;Jung-Young Choi
    • Journal of Korea Soil Environment Society
    • /
    • v.5 no.2
    • /
    • pp.45-53
    • /
    • 2000
  • Two extraction methods for total petroleum hydrocarbon (TPH) from contaminated soil were evaluated. The soil used for this study was sandy loam. Diesel oil was selected as representative petroleum hydrocarbons and was spiked at 100, 10,000, 50,000mg TPH/kg dry soil. Percentage recovery of TPH by shaking method was higher compared to Soxhlet extraction. At extraction time of 2 hours and sample to solvent ratio of 1 : 5, the highest percentage recovery was obtained. In this condition, percentage recovery of TPH in soil contaminated with 100mg/kg and 50,000mg/kg as TPH was 95.9% and 95.5%, respectively The volume of solvent lost by volatilization in shaking method was relatively small compared to Soxhlet extraction.

  • PDF

The Simultaneous Analysis of Benzene, Toluene, Ethylbenzene, o,m,p-Xylenes and Total Petroleum Hydrocarbons in Soil by GC-FID after Ultra-Sonication

  • Sin, Ho Sang;Gwon, O Seung
    • Bulletin of the Korean Chemical Society
    • /
    • v.21 no.11
    • /
    • pp.1101-1105
    • /
    • 2000
  • A simultaneous determination method of BTEX (benzene, toluene, ethylbenzene, o,m.p-xylene) and TPH (kerosene, diesel, jet fuel and bunker C) in soil with gas chromatography/flame ionization detection (GC-FID) was described. The effects of extracti on method, extraction solvent, solvent volume and extraction time on the extraction performance were studied. A sonication method was simpler and more efficient than Soxhlet or shaking methods. Sonication with 10 mL of acetone/methylene chloride (1 : 1, v/v) for 10 min was found to be optimal extraction conditions for 20 g of soil. Peak shapes and quantification of BTEX and TPH were excellent, with linear calibration curves over a wide range of 1-500 mg/L for BTEX and 10-5000 mg/L for TPH. Good reproducibilities by sonication were obtained, with the RSD values below 10%. By using about 20 g of soil, detection limits were 0.8 mg/L for BTEX and 10 mg/L for TPH. The advantages of this procedure are the use of simple and common equipment, reduced volumes of organic solvents, rapid extraction periods of less than 20 min, and simultaneous analysis of volatile and semivolatile compounds.