• 제목/요약/키워드: TP water quality standard

검색결과 39건 처리시간 0.027초

갑천 상류부의 수질오염 우려구간 수질특성 및 수질관리방안 (Characteristics and Management Plan of Water Quality at the Water Pollution Deterioration Area of the Upper Stream of Gapcheon)

  • 장유호;손봉호;저소웅;임봉수
    • 한국물환경학회지
    • /
    • 제35권5호
    • /
    • pp.399-408
    • /
    • 2019
  • The average annual water quality at Yongchon Bridge, Bonggok 2 Bridge, and Gasuwon Bridge in upstream of Gapcheon in 2018 was Ib grade (good) in organic matters, including BOD and TOC compared to the local environmental standard in Daejeon. However, their monthly changes for TOC partially exceeded the standard during the busy farming season at Bonggok 2 Bridge and Gasuwon Bridge. Although the annual average TP was within the standard, the monthly change at Bonggok 2 Bridge partially exceeded the standard. For Dugyecheon, the annual average water quality in 2018 at Umyeon-dong Bridge and Wonjeong Bridge, which are downstream of the Gyeryong public sewage treatment plant, exceeded the local environmental standard in BOD. COD was exceeded, and TP was within the standard. It seemed that the causes of deteriorated water quality downstream of Dugyecheon were discharges of agricultural water from agricultural land and effluent from the Gyeryong public sewage treatment plant. Assuming the pollution load of 100% based at the Mulangil point of the mainstream of Gapcheon, the ratio of BOD load and TOC load were as high as 58% and 47%, respectively. At the basin of Bonggok 2 Bridge and Mulangil, the loads downstream of Dugyecheon including the Gyeryong public sewage treatment plant were as high as 43% for TN and 56% for TP, respectively, indicating that Dugyecheon had a major impact on the water quality at the mainstream of Gapcheon.

부착돌말류를 이용한 생물학적 수질평가지표 개발 (Development of Biological Criteria for Water Quality Assessment using Benthic Diatoms)

  • 노성유;변명섭;김미아;이재관
    • 한국물환경학회지
    • /
    • 제25권6호
    • /
    • pp.879-885
    • /
    • 2009
  • The present study was carried out to develop biological criteria for water quality assessment using benthic diatoms. Selecting of the indicator diatoms, three parameters were considered: broad distribution (180 taxa occurred over 3% at upper level), species abundance (158 taxa occurred over $1.5{\times}10^5cells/cm^2$), and sensitivity (184 taxa occurred more than once as 1st and 2nd dominant species). Overall, total 208 taxa were selected, including 38 varieties, 170 species, 34 genera, 9 families, 3 orders, and 1 phylum. The most dominant taxonomic group (family) was Naviculaceae (52%), followed by Diatomaceae (15%), Nitzschiaceae (12%) and Achnantaceae (11%). COD and TP were proposed as new water quality standards (draft) to improve the existing BOD standard and to manage and control efficiently non-biodegradable organic pollutants. With this regard, we used TP standard (draft) in developing biological water quality criteria for diatoms. TP standards (draft) proposed as Ia = 0.02 mg/L or less, Ib = 0.05 mg/L or less, II = 0.1 mg/L or less, III = 0.2 mg/L or less, IV = 0.4 mg/L or less, V = 0.6 mg/L or less and VI = above 0.6 mg/L. Biological assessment system (4 class system) was developed and proposed for diatom using modified Tropic Diatom Index (TDI). Biological assessment of TDI appear B grade (Good).

강원도내 주요하천 수계별 목표수질 설정 및 달성도 연구 (A Study on the Establishment and Achievement of Target Water Quality by Water System of Major Streams in the Gangwon Province)

  • 허인량;최지용;김영진;김성석
    • 한국환경보건학회지
    • /
    • 제32권5호
    • /
    • pp.424-430
    • /
    • 2006
  • Since 1985, the Gangwon Institute of Health and Environment(GIHE) and Ministry of Environment have collected rivers and streams water quality data in an ambient surface water monitering program. This study was prepared to propose an achievement of water quality of rivers subject to management by area according to an created level while establishing a water quality level applicable to the Gangwon area. As a result of evaluating correlativity on the BOD-based water quality data, BOD versus TP, and TP versus SS demonstrated significance at a confidence level of 95%. Evaluating correlativity on $10{\sim}90$ percentile values of analyzed data, a coefficient of determination, $r^{2}$ of BOD versus TP, and TP versus SS were 0.625, 0.286 respectively. Grading the results by evaluation method, the representative values of TP were 0.030 mg/l for I level, 0.100 mg/l for II level, 0.200 mg/l for Ill level, 0.300 mg/l for IV level, and 0.350 mg/l for V level, and those of SS were indicated 4.0 mg/l for I level, 15.0 mg/l for II level, 30.0 mg/l for III level, 45.0 mg/l for IV level, and 60.0 mg/l for V level. As for the limiting factor allowing the water quality standard exceeded, BOD posted 61% as the factor was found in 11 places, TP 28%, and SS 33%.

수질과 오염원의 장기적 변화를 통한 팔당호 상수원수질보전 특별대책지역 규제효과 분석 (A Study on the Regulatory Effect of the Special Water Preservation Area of Lake Paldang Watershed Based on Long-Term Variation of Pollutant Source and Water Quality)

  • 김호섭;박윤희;김용삼;김상용
    • 한국물환경학회지
    • /
    • 제35권1호
    • /
    • pp.43-54
    • /
    • 2019
  • The objective of this study was to assess the effect of policies on water quality management based on the changes in pollutants and water quality in Special Water Preservation Area (SWPA) of Lake Paldang watershed from 1990 to 2016. The population, total sewage and flow rate of wastewater in SWPA continuously increased from 1990 to 2016, while the location of new facilities for industrial and livestock facilities has been restricted. However, unlike the buffer zone in which industrial and livestock facilities were continuously reduced after implementing of TMDL, it was found that the effect of land-use regulations on industrial and livestock facilities in SWPA were mitigated by the increase in the size of large facilities. Since 1999 when the emission standard of public sewage treatment plants (STP) was changed, the water quality of Lake Paldang has increased despite the increase of pollutant source. Since emission standard of STP changed in 2012 (BOD 5 mg/L, TP 0.2 mg/L), BOD concentration in Lake Paldang has also improved to the level of water quality in the early 1990s where as TP concentration has remained at its lowest since 1990. BOD and TP average discharge concentration of 43 STP (${\geq}500m^3/day$) in 2016 have been maintained $1.7{\pm}0.7mg/L$ and $0.06{\pm}0.02mg/L$ respectively. While the discharged load of STP in SWPA was decreased by the concentration management, the contribution rate to the total discharged load of non-point pollutants increased to 70 % in 2015, and the contribution rate to the point discharged load of individual treatment facilities increased to 80 %.

경기도 북부지역 골프장연못 수질특성에 관한 연구 (A Study on Water Quality for Golf Course Pond in Northern Areas in Gyeonggi Porvince)

  • 김재광;황찬원;박진호;김지영;오조교
    • 한국환경보건학회지
    • /
    • 제44권4호
    • /
    • pp.323-329
    • /
    • 2018
  • Objectives: The purpose of this study is to investigate the water quality of 16 golf course ponds located in northern areas Gyeonggi province by investigating residual pesticides, organic matters (BOD, TOC) and nutrients (TN, TP). Methods: The result data for the residual pesticides were used from 2014 to 2017. and other result data were used for April and July in 2017. The residual pesticides analytical method was based on 'Golf course residual pesticides inspection method', The others analytical method was based on 'The water pollution process test standard' Results: Very toxic pesticides and banned pesticides were not detected but general pesticides were detected. In case of the water quality of the golf course pond was applied to the lake water quality standard. In April the average TOC concentration was V grade to 6.46 mg/L, TP V grade to 0.13 mg/L, TN VI grade to 1.6 mg/L, In July TOC average concentration was VI grade to 8.65 mg/L, TP VI grade to 0.17 mg/L, TN V to 1.5 mg/L. All TN and TP concentrations corresponded to eutrophication. Compared with lake water quality monitoring, the concentrations of BOD, TOC and TP were high but the TN concentration was low in April and July. Conclusions: It is considered that water quality managements are necessary for the golf course pond. The first reason is that the pollutants of pond are discarded to river during rainfall and act as pollution sources. The second reason is that the golf course users are uncomfortable because of odor caused by the pollutants of the pond.

우리나라 공공하수처리시설의 방류수 수질현황 분석을 통한 겨울철 방류수수질기준의 적정성 평가 (Evaluation of Korean Water Quality Standards in Winter by Characteristics and Statistical Analyses of the Effluent Water Quality at the Sewage Treatment Plants in Korea)

  • 엄철용;주경훈;윤주환;최익훈;박재영;이한샘;고광백
    • 한국물환경학회지
    • /
    • 제27권4호
    • /
    • pp.523-532
    • /
    • 2011
  • In this study, from 2004 to 2008 influents and discharging effluents from 241 municipal public sewage treatment plants were surveyed. Statistics including average, Coefficient of Variation (CV) and Coefficient of Reliability (COR) for each season, time series analysis for removal efficiency and water quality of effluents, and a comparison of the effluent standards in Korea and other countries were presented. The average concentrations of TN and TP in influents. during winter season were 32.6 and 3.78 mg/L and during other season were 30.8 and 3.61 mg/L in 2008, respectively. The average TN concentration on the basis of the maximum monthly concentrations in the effluents during winter season ranged from 14.2~17.4 mg/L and during other season ranged from 12.2~14.8 mg/L. The TP concentration in the effluents depending on the each season was no big difference. TN removal efficiency decreased from Jan. to Feb. and TP removal efficiency decreased in Jan., Jun and July. Maximum COR during winter season were 0.61 but the COR for TN and TP during other season ranged from 0.96~1.48 and 1.09~1.81, respectively, due to big difference in the standard for TN and TP in effluents depending on the season. TN and TP standards for effluent of sewage treatment during winter season in Korea was much higher than those in other countries. Therefore the lower effluent standards during winter season is essential for the water quality improvement.

새만금호의 수질 특성 및 영양상태지수를 이용한 부영양화 평가 (Assessment of Eutrophication Using Trophic State Index and Water Quality Characteristics of Saemangeum Lake)

  • 김종구
    • 해양환경안전학회지
    • /
    • 제29권6호
    • /
    • pp.587-597
    • /
    • 2023
  • 조류의 이상증식을 일으키는 새만금호 부영양화를 평가하기 위해 Carlson 지수를 적용하였다. 연구를 위해 2021년 월별로 새만금호내 총 7개 정점에서 수질조사를 실시하였다. Chl.a의 농도는 동계에는 만경수계가 약간 높았고, 춘계와 하계에는 동진수계가 약간 높게 나타났으나, 일부 시기를 제외하고는 전체적으로 호소 수질환경기준 3등급과 비슷하거나 낮은 농도를 나타내었다. COD는 만경수계와 동진수계 모두 하계와 추계에 호소 수질환경기준 4등급과 유사하거나 상회하는 수질을 나타내었다. TOC는 모든 지점에서 3등급 이내의 수질을 보였다. 총인 농도는 호수 수질환경기준 4등급을 초과하였고, 월별로는 1월과 강우 후 8월에 높게 나타났다. 수질인자간의 상관성 분석에서 염분 농도에 대한 유기물, 총인, 총질소의 상관성이 상대적으로 높게 나타나 배수갑문을 통한 해수유입과 상류 하천을 통한 담수 유입에 의한 담수역, 기수역, 해수역의 수질 특징을 반영하고 있었다. 영양상태지수에 의한 새만금호의 부영양화 변동 특성을 보면, Chl.a와 SD, TN의 지수에서 부영양화 초기 단계의 수질을 보였으며, TP 지수의 경우 심각한 부영양화 상태를 나타내고 있었다. 수질인자간 부영양화 지수의 크기는 모든 수계에서 TSI(TP) > TSI(TN) > TSI(SD) > TSI(CHL)의 순으로 나타났다. TSI(CHL)에 대한 TSI(TP) 및 TSI(SD)와의 편차를 2차원 평면으로 나타낸 사분면 분석 결과를 보면, 조류 성장에 대한 총인이 영향에서는 모든 수계에서 대부분의 총인(TP)에 의한 제한적 영향은 나타나지 않았으며, 빛 감쇠에 영향을 미치는 인자는 외부로부터 유입되는 적은 입자상 물질에 의한 영향이 크게 나타나는 것으로 평가할 수 있다.

유량-부하량 관계식과 8일 간격 누적유량지속곡선을 이용한 오수천의 수체 손상도 분석 (Analysis of Water bady Damage at Osu Stream Using the Flow-Loading Equation and 8-Day Intervals Cumulative Flow Duration Curve)

  • 이영성;김영석;한성욱;서권옥;임창복;이영재;김경현;정강영
    • 한국환경과학회지
    • /
    • 제27권12호
    • /
    • pp.1179-1193
    • /
    • 2018
  • The purpose of this study at water quality pollutants to propose proper management method for the Osu-A unit watershed which is the influent tributary located upstream of the Sumjin -river among the 13 unit watersheds in the Sumjin-river water system. Analyzed the correlation between flow-pollution loading and the correlation between land use type, BOD and TP items, and analyzed 8-day intervals Cumulative Flow Duration Curve (CFDC) and Load Duration Curve (LDC) to evaluate water quality damage. As a result, both BOD and TP were larger than 1 and the concentration of water pollutants increased with increasing flow. BOD was positively correlated with Urban and Field, and TP was positively correlated with Field with 0.710. As a result of the LDC, BOD was analyzed that the target water quality was achieved with the excess rate of less than 50%, and TP exceeded the target water quality by 50.1%. BOD usually exceeded the standard value (exceedance probability 50%) at low flow zone and On the other hand, TP usually exceeded the standard value at high flow zone. Monthly BOD (April to June) and TP (May to August) exceeded the standard. Sewage Wastewater treatment and non-point pollution control is Osu-A unit watersheds are effective in improving BOD and TP.

Rainfall and Water Quality Characteristics of Saemangeum Area

  • Monica, Nankya;Choi, Kyung-Sook
    • Current Research on Agriculture and Life Sciences
    • /
    • 제32권4호
    • /
    • pp.203-209
    • /
    • 2014
  • This study investigated characteristics of rainfall and water quality in Saemangeum area with attention to temporal and spatial distributions. A high variability in rainfall was noted during July and August. The temporal analysis of water quality data indicated that DO and TN as well as BOD, COD and SS were within national standards except for increased concentrations during spring and summer, unlike TP values that indicated poor water quality. Standard deviation showed a high variability in SS among the seasons most especially during summer. The high dispersion indicated variability in the chemical composition of pollutants where the temporal and spatial variations caused by polluting sources and/or seasonal changes were most evident for BOD and COD during winter and spring. The box plots and bar charts showed steadily low concentrations of BOD, COD, TN and TP except within Iksan and notable significant variations in SS concentrations among the monitoring stations. Thus, high pollution levels requiring intervention were identified in Mangyeong river basin with particular concern for areas represented by Iksan station. It was noted that Iksan received a considerable amount of rainfall which meant high runoff which could explain the significant pollution levels revealed in the water quality spatial distribution. Major pollution contributing pollutants within Saemangeum area were identified as SS, BOD, COD and TN. Therefore the present results could be used as a guideline for the temporal and spatial distributions analysis of both rainfall and water quality in Saemangeum watershed.

한국의 호수 수질관리의 문제점 (Problems of lake water management in Korea)

  • 김범철;전만식;김윤희
    • 한국환경생태학회:학술대회논문집
    • /
    • 한국환경생태학회 2003년도 추계학술논문발표회 논문집
    • /
    • pp.105-126
    • /
    • 2003
  • In Korea most of annual rainfall is concentrated in several episodic heavy rains during the season of summer monsoon and typhoon. Because of uneven rainfall distribution many dams have been constructed in order to secure water supply in dry seasons. The Han River system has the most dams among Korean rivers, and the river is a series of dams now. Reservoirs need different strategy of water quality control from river water. Autochthonous organic matter and phosphorus should be the major target to be controlled in lakes. In this Paper some problems are discussed that makes efforts of water quality improvement ineffective in lakes of Korea, even after the substantial investment to wastewater treatment facilities.1) Phosphorus is the key factor controlling eutrophication of lakes and the reduction ofphosphors should be the major target of water treatment. However, water quality management strategy in Korea is still stream-oriented, and focused on BOD removal from sewage. Phosphorus removal efficiency remains as low as 10-30%, because biological treatment is adopted for both secondary treatment and advanced treatment. The standard for TP concentration of the sewage treatment plant effluent is 6 mgP/l in most of regions, and 2 mg/l in enforced region near metropolitan water intake point. TP in the effluents of sewage treatment plants are usually 1-2 mg/1, and most of plants meet the effluent regulation without a further phosphorus removal process. The generous TP standard for effluents discourages further efforts to improve phosphorus removal efficiency of sewage treatment. Considering that TP standard for the effluent is below 0.1 mg/l in some countries, it should be amended to below 0.1 mg/l in Korea, especially in the watershed of large lakes.2) Urban runoff and combined sewer overflow are not treated, even though their total loading into lakes can be comparable to municipal sewage discharges on dry days. Chemical coagulation and rapid settling might be the solution to urban runoff in regard of intermittent operation on only rainy days.3) Aggregated precipitation in Korea that is concentrated on several episodic heavyrains per year causes a large amount of nonpoint source pollution loading into lakes. It makes the treatment of nonpoint source discharge by methods of other countries of even rain pattern, such as retention pond or artificial wetland, impractical in Korea.4) The application rate of fertilizers in Korea is ten times as high as the average ofOECD countries. The total manure discharge from animal farming is thought to be over the capacity of soil treatment in Korea. Even though large portion of manure is composted for organic fertilizer, a lot of nutrients and organic matter emanates from organic compost. The reduction of application rate and discharge rate of phosphorus from agricultural fields should be encouraged by incentives and regulations.5) There is a lot of vegetable fields with high slopes in the upstream region of the HanRiver. Soil erosion is severe due to high slopes, and fertilizer is discharged in the form of adsorbed phosphorus on clay surface. The reduction of soil erosion in the upland area should be the major preventive policy for eutrophication. Uplands of high slope must be recovered to forest, and eroded gullies should be reformed into grass-buffered natural streams which are wider and resistant to bank erosion.

  • PDF