• Title/Summary/Keyword: TOX-deck plate

Search Result 2, Processing Time 0.015 seconds

Test on the Structural Performance of the TOX Deck plate - Evaluation of Structural Safety during Construction Stage - (무용접 압접 데크플레이트의 구조성능에 관한 실험 - 시공단계에서의 구조안전성 평가 -)

  • Oh, Sang Hoon;Kim, Young Ju;Yoon, Myung Ho
    • Journal of Korean Society of Steel Construction
    • /
    • v.20 no.6
    • /
    • pp.701-709
    • /
    • 2008
  • Owing to the decreased work term and the convenience of construction work in Korea, the steel deck plate system has been widely used in the construction field. Most of all, due to its good stiffness and economic consideration, the steel-wire-integrated deck plate system (or truss deck plate system) has become very popular in recent years. But although it has many advantages, the truss deck plate system has a critical defect: it gets rusty in the welding joints between the lattice steel wire and the deck plate, resulting in the cracking of such welding joints and water leakage. To address these problems, a new type of truss deck plate system, which need not be welded and does not rust, was proposed herein: the TOX deck plate system. In this study, tests were conducted on 15 specimens to evaluate the structural safety of the proposed deck plate system during the construction stage. The test parameters were as follows: the depth of the slab the length of the span the diameters of the top, bottom, and lattice steel wire and the material properties of the zinc-coated steel sheets. The test results show that the TOX deck plate system can guarantee structural safety owing to its deflection and strength.

Design Program of Deck Plate Slab System with Non-welding Truss Type Reinforced Bar (철근트러스 압접 데크플레이트 바닥 구조의 설계 프로그램)

  • Yoon, Myung-Ho;Oh, Sang-Hoon
    • Journal of The Korean Digital Architecture Interior Association
    • /
    • v.8 no.1
    • /
    • pp.57-64
    • /
    • 2008
  • There are many problems in present truss-deck slab system for example welding defect, segregation, water leakage, rust and tarnish etc. These problems may be caused by spot welding thin galvanized steel plate and lattice bar. The TOX Joining Systems is to join metal sheets of different material and thickness with and without coating or painting without adding heat or a joining part. Newly developed TOX-deck slab system using non-welding joint is free from above mentioned problems. The objects of this study are suggestion of design strength of TOX joint by experimental and statistical analyses and development of window based program to design the TOX-deck slab system.

  • PDF