• Title/Summary/Keyword: TOTAL NITROGEN(TN)

Search Result 345, Processing Time 0.033 seconds

The effect of nitrogen contents in media and cultivation temperature on freshness prolongation in Pleurotus eryngii (큰느타리버섯 배지 질소함량 및 온도조건별 선도연장효과)

  • Moon, Ji-Young;Kim, Jeong-Han;Choi, Jong-In;Jeong, Gu-Hyun;Gwon, Hee-Min;Ha, Tai-Moon
    • Journal of Mushroom
    • /
    • v.18 no.4
    • /
    • pp.339-343
    • /
    • 2020
  • This study aimed to optimize total nitrogen (TN) content in the medium and the growth temperature to improve the shelf life of Pleurotus eryngii Keneutari No. 2. We investigated the growth characteristics and changes in the O2/CO2 content in polypropylene film and performed sensory evaluations during cold storage under 1.5%, 1.8%, 2.1%, and 2.4% TN and at temperatures of 9℃, 12℃, and 15℃. The diameter and weight of the fruit bodies tended to increase with increasing nitrogen content, regardless of the growth temperature, and the highest weight per bottle (149.5 g) was obtained at 12℃ and 2.4% TN. Regardless of the nitrogen content, leaf color deepened with decreasing temperature. The gas concentration in the film, which changes depending on storage time, was maintained for the longest period at 9℃ and 2.1% TN. The sensory evaluation revealed no difference between the different nitrogen conditions tested, and the odor, discoloration, and decay were similar at 15℃ and 9℃ until day 28 of storage.

Temporal and spatial variation analysis on nutritive salt of Hongze Lake

  • Zhang, Min;Chu, Enguo;Xu, Ming;Guo, Jun;Zhang, Yong
    • Environmental Engineering Research
    • /
    • v.20 no.1
    • /
    • pp.19-24
    • /
    • 2015
  • This paper mainly focuses on the research of the monitoring data about the total nitrogen (TN), total phosphorus (TP) of ten monitoring points of Hongze Lake in 28 years. Our study adopts the technical methods such as difference comparison, correlation analysis, Mann-Kendall, etc. to analyze the statistical characteristics, regional differences, and temporal and spatial variation condition of ten monitoring points of Hongze Lake in 1986-2013 as well as the reason for the time and space variation of TN and TP. The results show that the TN and TP of Hongze Lake change dramatically during the period of 1994-2004. In all the monitoring periods, TN and TP of the HZ5, HZ6, HZ7, HZ8 monitoring points in the estuary surrounding the Huaihe River are the highest, which suggests that TN and TP of Hongze Lake should not be ignored for the pollution along the Huaihe River. The TN concentration in the core area is the highest, but that in the development control area is the lowest. In most of the years, TN concentration is higher than 2 mg/L, and the water quality is V class and poor V class water quality in China's Environmental Quality Standards for Surface Water (GB3838-2002). TP concentration of the three areas is basically close, that is lower than 2 mg/L in most of the years, and the water quality is within the V class. The TN and TP concentration of Hongze Lake decreased and intensifying trend of eutrophication is controlled after 2004.

Inter-laboratory Comparison of Stable Carbon and Nitrogen Isotopic Composition Data Using Elemental Analyzer-isotope Ratio Mass Spectrometers

  • Kim, Jung-Hyun;Kang, Sujin;Bong, Yeon-Sik;Park, Kwangkyu;Kang, Tae-Woo;Park, Yong-Se;Kim, Dahae;Choi, Seunghyun;Joo, Young Ji;Choi, Bohyung;Nam, Seung-Il;Lee, Sang-Mo;Shin, Kyung-Hoon
    • Journal of Environmental Analysis, Health and Toxicology
    • /
    • v.21 no.4
    • /
    • pp.229-236
    • /
    • 2018
  • In this study, inter-laboratory comparison was done using elemental analyzer-isotope ratio mass spectrometers (EA-IRMSs) to determine carbon and nitrogen contents as well as stable carbon and nitrogen isotopic compositions (${\delta}^{13}C$ and ${\delta}^{15}N$) of five environmental samples containing lake and marine sediments, higher plant leaves, and fish muscle, and one organic analytical standard (Protein (Casein) Standard OAS). Five national laboratories participated in this comparison study, and each laboratory analyzed all five samples and the analytical standard. Results showed that variations in total organic carbon (TOC) and total nitrogen (TN) contents as well as ${\delta}^{13}C_{TOC}$ and ${\delta}^{15}N_{TN}$ values among the laboratories were large compared to the analytical uncertainties. The results highlighted the inhomogeneity of the test samples and thus, the need to select suitable standard reference materials for future inter-laboratory studies. Further inter-laboratory comparison exercises could promote good measurement practices in the acquisition of stable carbon and nitrogen isotopic composition data.

Forward Osmosis Membrane to Treat Effluent from Anaerobic Fluidized Bed Bioreactor for Wastewater Reuse Applications (하수재이용을 위한 혐기성 유동상 생물반응기 처리수의 정삼투 여과막의 적용)

  • Kwon, Dae-eun;Kim, Jeonghwan
    • Membrane Journal
    • /
    • v.28 no.3
    • /
    • pp.196-204
    • /
    • 2018
  • The anaerobic fluidized bed bioreactor (AFBR) treating synthetic wastewater to simulate domestic sewage was operated under GAC fluidization to provide high surface area for biofilm formation. Although the AFBR achieves excellent COD removal efficiency due to biological activities, concerns are still made with nutrient such as nitrogen remaining in the effluent produced by AFBR. In this study, forward osmosis membrane was applied to treat the effluent produced by AFBR to investigate removal efficiency of total nitrogen (TN) with respect to the draw solution (DS) such as NaCl and glucose. Permeability of FO membrane increased with increasing DS concentration. About 55% of TN removal efficiency was observed with the FO membrane using 1 M of NaCl of draw solution, but almost complete TN removal efficiency was achieved with 1 M of glucose of draw solution. During 24 h of filtration, there was no permeate flux decline with the FO membrane regardless of draw solution applied.

Influence of mixed liquor suspended solids on the removal efficiency of a hybrid membrane bioreactor

  • Palmarin, Matthew J.;Young, Stephanie
    • Membrane and Water Treatment
    • /
    • v.7 no.1
    • /
    • pp.11-22
    • /
    • 2016
  • The characterization of treatment performance with respect to mixed liquor suspended solids (MLSS) concentration enables greater control over system performance and contaminant removal efficiency. Hybrid membrane bioreactors (HMBRs) have yet to be well characterized in this regard, particularly in the context of greywater treatment. The aim of this study, therefore, was to determine the optimal MLSS concentration for a decentralized HMBR greywater reclamation system under typical loading conditions. Treatment performance was measured at MLSS concentrations ranging from 1000 to 4000 mg/L. The treated effluent was characterized in terms of biochemical oxygen demand ($BOD_5$), chemical oxygen demand (COD), turbidity, ammonia ($NH_3$), total phosphorus (TP), total kjeldahl nitrogen (TKN), and total nitrogen (TN). An MLSS concentration ranging from 3000 to 4000 mg/L yielded optimal results, with $BOD_5$, COD, turbidity, $NH_3$, TP, TKN, and TN removals reaching 99.2%, 97.8%, 99.8%, 99.9%, 97.9%, 95.1%, and 44.8%, respectively. The corresponding food-to-microorganism ratio during these trials was approximately 0.23 to 0.28. Operation at an MLSS concentration of 1000 mg/L resulted in an irrecoverable loss of floc, and contaminant residuals exceeded typical guideline values for reuse in non-potable water applications. Therefore, it is suggested that operation at or below this threshold be avoided.

Treatment of Pollutants in Free Water Surface Constructed Wetlands with Lotus (Nelumbo nucifera) Cultivation Pond (연 재배지를 활용한 자유수면형 인공습지의 수질정화효율)

  • Han, Myung-Ja;Seo, Dong-Cheol;Kang, Se-Won;Lee, Yong-Chol;Bang, Seok-Bae;Chae, Jung-Heon;Kim, Kap-Soon;Park, Jong-Hwan;Chang, Nam-Ik;Heo, Jong-Soo;Cho, Ju-Sik
    • Journal of Applied Biological Chemistry
    • /
    • v.53 no.4
    • /
    • pp.232-238
    • /
    • 2010
  • In order to investigate the treatment efficiency of pollutants in free water surface constructed wetlands (FWS CWs) with lotus (Nelumbo nucifera) cultivation pond, the experiment was consisted of two sites (site I and II) in Lake Juam, Korea. The sites were configured a lotus cultivation pond (with fertilizer application) - a dropwort bed - a reed bed for site I, and a lotus cultivation pond (without fertilizer application) - a dropwort bed - a reed bed for site II. Removal rate of COD in site I and II were 13.3% and 26.0%, respectively. Removal rate of total nitrogen (TN) was 29.7% for site I, and 36.3% for site II. Removal rate of total phosphorus (TP) in site I and II were 36.0% and 36.5%, respectively. COD, TN and TP in effluent from site I (with fertilizer) was higher than that in site II (without fertilizer), showing that COD, TN and TP in effluent were strongly influenced by fertilizer addition. Therefore, in order to satisfy established water-quality standards, the amount of fertilizer used in lotus cultivation showed be evaluated.

Effect of the supernatant reflux position and ratio on the nitrogen removal performance of anaerobic-aerobic slaughterhouse wastewater treatment process

  • Tong, Shuang;Zhao, Yan;Zhu, Ming;Wei, Jing;Zhang, Shaoxiang;Li, Shujie;Sun, Shengdan
    • Environmental Engineering Research
    • /
    • v.25 no.3
    • /
    • pp.309-315
    • /
    • 2020
  • Slaughterhouse wastewater (SWW) is characterized as one of the most harmful agriculture and food industrial wastewaters due to its high organic content. The emissions of SWW would cause eutrophication of surface water and pollution of groundwater. This study developed a pilot scale anaerobic-aerobic slaughterhouse wastewater treatment process (AASWWTP) to enhance the chemical oxygen demand (COD) and total nitrogen (TN) removal. The optimum supernatant reflux position and ratio for TN removal were investigated through the modified Box-Behnken design (BBD) experiments. Results showed that COD could be effectively reduced over the whole modified BBD study and the removal efficiency was all higher than 98%. The optimum reflux position and ratio were suggested to be 2 alure and 100%, respectively, where effluent TN concentration was satisfied with the forthcoming Chinese discharge standard of 25 mg/L. Anaerobic digestion and ammonia oxidation were considered as the main approaches for COD and TN removal in the AASWWTP. The results of inorganic nutrients (K+, Na+, Ca2+ and Mg2+) indicated that the SWW was suitable for biological treatment and the correspondingly processes such as AASWWTP should be widely researched and popularized. Therefore, AASWWTP is a promising technology for SWW treatment but more research is needed to further improve the operating efficiency.

The runoff characteristics of non-point source to urban stream during rainfall (강우 시 도시 하천으로의 비점오염원 유출특성)

  • Park, Woon-Ji;Kim, Dong-Oog;Ahn, Johng-Hwa;Lee, Chan-Ki
    • Journal of Industrial Technology
    • /
    • v.27 no.B
    • /
    • pp.83-89
    • /
    • 2007
  • We studied runoff characteristics of combined sewer overflows in a city while it was raining. The event mean concentration (EMC) of biochemical oxygen demand (BOD), chemical oxygen demand ($COD_{Cr}$), suspended solids (SS), total nitrogen (TN), and total phosphorus (TP) in one of the combined sewer sites in Chuncheon was 63.5-211.6 mg/L, 114.9-523.8 mg/L, 70.3-436.4 mg/L, 6.4-33.0 mg/L, and 1.09-6.81 mg/L, respectively. In another combined sewer, the EMC of BOD, COD, SS, TN, and TP was 42.1-131.4 mg/L, 107.7-256.5 mg/L, 33.7-221.1 mg/L, 7.9-26.4 mg/L, and 1.16-3.91 mg/L, respectively. The ratio of the cumulative pollutant mass and the cumulative discharged volume determined using all parameters (BOD, $COD_{Cr}$, SS, TN, and TP) was over 1.0, which shows the first flush effect. Relationships between flow and loadings of BOD, $COD_{Cr}$, SS, TN, and TP were 0.90, 0.89, 0.88, 0.89, 0.92, respectively. Although the size of two areas was almost same, pollutant concentration and loading were different because of the amount of rainfall, rainfall intensity and basin area.

  • PDF

The Distribution of Nitrogen and the Decomposition Rate of Organic Nitrogen in the Youngsan River and the Sumjin River, Korea (영산강과 섬진강 수계의 질소 분포와 유기질소 분해속도)

  • Kim, Jihye;Kim, Bomchul;Shin, Myoungsun;Kim, Jaiku;Jung, Sungmin;Lee, Yunkyoung;Park, Juhyun
    • Journal of Korean Society on Water Environment
    • /
    • v.25 no.1
    • /
    • pp.142-150
    • /
    • 2009
  • The distribution of organic nitrogen and its decomposition rate were studied in the Youngsan River and the Sumjin River system in Korea. Samples were conducted seasonally in June, August, December of 2006, and February of 2007. Collected samples were incubated for 20 days in a dark chamber ($20{\pm}1^{\circ}C$) and analyzed the changes of nitrogen form (particulate organic nitrogen, dissolved organic nitrogen, ammonia, nitrite, and nitrate). The mean total nitrogen (TN) concentration in the Youngsan River and the Sumjin River were $2.62mgN{\cdot}L^{-1}$ and $1.53mgN{\cdot}L^{-1}$, respectively. TN comprised of 65% DIN and 35% ON. The decomposition coefficients of organic nitrogen were also determined by two different fitting models. The decomposition rates of nitrogen species (TON, LPON, LDON, ${NH_4}^+$ and ${NO_2}^-$) ranged from 0.024 to $1.043day^{-1}$ in the Youngsan River and 0.008 to $0.693day^{-1}$ in the Sumjin River, respectively. The result of this study can give a guide to the selection of parameters in the calibration processes of water quality models.

Nutrient Balance in the Paddy Fields Watershed with a Source of River Water (하천관개지역 광역논에서의 영양물질의 물질수지)

  • Lee, Jeong Beom;Lee, Jae Yong;Li, Si Hong;Jang, Jeong Ryeol;Jang, Ik Geun;Kim, Jin Soo
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.56 no.5
    • /
    • pp.11-19
    • /
    • 2014
  • The objective of this research was to investigate concentration and load of nutrients such as total nitrogen (TN), nitrate nitrogen ($NO_3$-N) total phosphorous (TP), and phosphate phosphorous ($PO_4$-P) in a 23.4-ha paddy fields watershed with river water source. Water samples for irrigation water, drainage water, ponded water and groundwater were collected, and irrigation and drainage water were measured at 5~10 day intervals during normal days and at 2~6 hours intervals during three storm events. The amount of irrigation water in the study area was over 2,000 mm, which is almost identical to that in the area irrigated from a large reservoir but much more than that in the area irrigated from a pumping station. Mean flow-weighted concentrations of TN and TP in irrigation water were 2.8 and 0.15 mg/L, respectively, higher than those in the area irrigated from a large reservoir or a pumping station. The ratios of irrigation load to total inflow load for TN and TP were 88 %, and the ratios of surface outflow load to total outflow load for TN and TP were over 90 %, indicating that total nutrient load may be greatly affected by water management. The nutrient loads per area in the study area were estimated as TN 21.1 kg/ha and TP 1.1 kg/ha. Especially, the TP load per area in the study area was smaller than that in the area irrigated from a large reservoir or a pumping station. This may be because outflow load is not high likely due to sedimentation of particulate P and irrigation water load is high due to high TP concentration in irrigation water and high amount of irrigation water.