• Title/Summary/Keyword: TOF method

Search Result 262, Processing Time 0.027 seconds

Mobility Determination of Thin Film a-Si:H and poly-Si

  • Jung, S.M.;Choi, Y.S.;Yi, J.S.
    • Journal of Sensor Science and Technology
    • /
    • v.6 no.6
    • /
    • pp.483-490
    • /
    • 1997
  • Thin film Si has been used in sensors, radiation detectors, and solar cells. The carrier mobility of thin film Si influences the device behavior through its frequency response or time response. Since poly-Si shows the higher mobility value, a-Si:H films on Mo substrate were subjected to various crystallization treatments. Consequently, we need to find an appropriate method in mobility measurement before and after the anneal treatment. This paper investigates the carrier mobility improvement with anneal treatments and summarizes the mobility measurement methods of the a-Si:H and poly-Si film. Various techniques were investigated for the mobility determination such as Hall mobility, HS, TOF, SCLC, TFT, and TCO method. We learned that TFT and TCO method are suitable for the mobility determination of a-Si:H and poly-Si film. The measured mobility was improved by $2{\sim}3$ orders after high temperature anneal above $700^{\circ}C$ and grain boundary passivation using an RF plasma rehydrogenation.

  • PDF

Analysis on the Mean energy of electrons in $SF_6-Ar$ Mixtures Gas used by MCS-BEq Algorithm ($SF_6-Ar$ 혼합기체(混合氣體)의 MCS-BEq알고리즘에 의한 전자(電子) 평균(平均)에너지 해석(解析))

  • Kim, Sang-Nam;Ha, Sung-Chul
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.05a
    • /
    • pp.281-284
    • /
    • 2004
  • Mean energy of electrons in $SF_6-Ar$ Mixtures Gas used by MCS-BEq algorithm has been analysed over the E/N range $30{\sim}300[Td]$ by a two term Boltzmann equation and by a Monte Carlo Simulation using a set of electron cross sections determined by other authors, experimentally the electron swarm parameters for 0.2[%] and 0.5[%] $SF_6-Ar$, 0.1[%] and 5.0[%], $SF_6-Ar$ mixtures were measured by time-of-flight(TOF) method. The transport Coefficients for electrons in (100[%])$SF_6$. (100[%])Ar, (0.2[%])$SF_6-Ar$ and (0.5[%]) $SF_6-Ar$, (5.0[%]) $SF_6-Ar$, (0.1[%])$SF_6-Ar$ mixtures were measured by time-of-flight method, and the electron energy distribution function and the parameters of the velocity and the diffusion were determined by the variation of the collision cross-sections with energy. The results obtained from Boltzmann equation method and Monte Carlo simulation have been compared with present and previously obtained data and respective set of electron collision cross sections of the molecules.

  • PDF

Distance measurement using pulsed eye-safe laser (펄스형 eye-safe 레이저를 이용한 거리측정)

  • 유병헌;조성학;장원석;김재구;황경현;이동주
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.10a
    • /
    • pp.106-109
    • /
    • 2004
  • In this project, we have developed the eye-safe LRF system of 1.54 ${\mu}{\textrm}{m}$ wavelength using OPO. The maximum measured distance was 3.7km in outdoor experiment. We used Nd:YAG (1064nm) as a laser medium. It was applied BBO to construct the system. We also developed a time-counter for the range finder using a method of TOF (time of flight). The counter-clock used at the time counter was 320MHz making resolution within $\pm$1m. Start and stop signals were detected by two channel systems using PIN and APD. The LRF's repetition rate was 4 times per minute. The energy was measured to be over 9mJ. And, pulse-duration was 23ns. Resolution was $\pm$2m at the distance measurement using a target.

  • PDF

The mean Energy in $SiH_4-Ar$ mixtures ($SiH_4-Ar$혼합기체의 평균에너지)

  • Kim, Sang-Nam
    • Proceedings of the KIEE Conference
    • /
    • 2007.11c
    • /
    • pp.155-159
    • /
    • 2007
  • This paper calculates and gives the analysis of electron swarm transport coefficients as described electric conductive characteristics of pure Ar, pure $SiH_4$, $Ar-SiH_4$ mixture gases ($SiH_4$--0.5%, 2.5%, 5%) over the range of E/N =$0.01{\sim}300$[Td], P=0.1, 1, 5.0[Torr] by Monte Carlo the Backward prolongation method of the Boltzmann equation using computer simulation without using expensive equipment. The results have been obtained by using the electron collision cross sections by TOF, PT SST sampling, compared with the experimental data determined by the other author. It also proved the reliability of the electron collision cross sections and shows the practical values of computer simulation.

  • PDF

The Study of Electron Transport coefficients in $SiH_4$-Ar Mixtures by Using Boltzmann Equation Analysis and Monte-Carlo Simulation (볼츠만방정식과 몬테칼로법에 의한 $SiH_4$-Ar 혼합가스의 전자수송계수에 관한 연구)

  • 하성철;전병훈
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.14 no.2
    • /
    • pp.169-174
    • /
    • 2001
  • The electron transport coefficients(the electron drift velocity, W, and the longitudinal and transverse diffusion coefficient, D$_{L}$ and D$_{T}$) in SiH$_4$-Ar mixtures containing 0.5% and 5.0% monosilane were calculated over the E/N range from 0.01 to 300 Td and over the gas pressure range 0.5, 1.0 and 1.5 Torr by the time-of-flight(TOF) method of the Boltzmann equation(BE.) and Monte-Carlo simulation(MCS). The electron energy distribution function in each SiH$_4$-Ar mixtures at E/N=10 Td and L=0.2 cm, which in equilibrium region in the mean electron enregy were compared.red.

  • PDF

NEUTRON ELASTIC AND NON-ELASTIC SCATTERING STUDIES IN TENS OF MeV REGION

  • Baba Mamoru;Ibaraki Masanobu;Miura Takako;Aoki Takao;Nakashima Hiroshi;Tanaka Shin-ichiro Meigo Susumu
    • Journal of Radiation Protection and Research
    • /
    • v.26 no.3
    • /
    • pp.265-270
    • /
    • 2001
  • Experimental data have been obtained on the neutron elastic scattering cross sections for 55, 65 and 75 MeV neutrons, and non-elastic scattering cross sections for 40 to 80 MeV neutrons using the $^7Li(p,n)$ neutron source at TIARA of Japan Atomic Energy Research Institute and the TOF method. Data were obtained for C, Si, Fe, Zr, and Pb of natural elements. Elastic scattering data were obtained for 25 laboratory angles between 2.6 and 53.0 that clarified the angular distributions and angle integrated values. The data obtained were compared favorably with recent LA150 data library.

  • PDF

Application of Malononitrile Derivatization Method for Structural Glycomics Study in Matrix-assisted Laser Desorption/Ionization Time-of-flight Mass Spectrometry

  • Ahn, Yeong-Hee;Yoo, Jong-Shin
    • Journal of Photoscience
    • /
    • v.8 no.2
    • /
    • pp.83-86
    • /
    • 2001
  • Structural analyses of oligosaccharide-malononitrile derivatives were conducted by matrix-assisted laser desorption/ionization post-source decay (MALDI-PSD) analysis in positive ion mode. The malononitrile derivatives of oligosaccharides, which were developed for highly sensitive detection of multi-component oligosaccharides by negative ion electrospray ionization mass spectrometry (ESI MS), were detected by positive-ion MALDI with the detection limit of 2 pmol level from the crude derivatization sample. The used matrix affected drastically the analytical results of oligosaccharide-malononitrile derivative by matrix-assisted laser desoprtion/ionization mass spectrometry (MALDI MS). The malononitrile derivatization of oligosaccharide also affect the patterns of MALDI-PSD spectra and give much more structural information than the free oligosaccharide.

  • PDF

High Throughput Proteomic Approaches for the Dissection of Light Signal Transduction Pathways in Photosynthetic Cyanobacterium Synechocystis sp.PCC 6803

  • Chung Young-Ho;Park Young Mok
    • Proceedings of the Microbiological Society of Korea Conference
    • /
    • 2002.10a
    • /
    • pp.203-205
    • /
    • 2002
  • Light is an environmental signal that regulates photomovement and main energy source of photosynthesis in the cyanobacterium Synechocystis sp. PCC 6803 (Syn6803). Syn6803 is a popular model system for study of plant functional genomics. In this report, we adopted 2D gel based proteomics study to investigate proteins related with the light absorption and photo-protection in Syn6803. More than 700 proteins were detected on the SDS-gels stained with silver nitrate. Several proteins showing different expression level under various light conditions were identified with MALDI-TOF Mass spectrometry. As a comparison, we also conducted ICAT-based proteome study using WT and cphl (cyanobacterial phytochrome 1) mutant. A cphl deletion led to changes in the expression of proteins involved in translation, photosynthesis including photosystem and CO2 fixation, and cellular regulation. We are currently involved in TAP-tagging method to study protein-protein interactions in search for the molecular component involved in the light signal transduction of Syn6803 photomovement.

  • PDF

Proteomic identification of the bovine pregnancy associated proteins by peptide mass fingerprinting

  • Kang, Sun-Chul;Kim, Eun-Jung;Pyo, Jae-Hoon;Lim, Jin-Kyu
    • 한국생물공학회:학술대회논문집
    • /
    • 2002.04a
    • /
    • pp.558-561
    • /
    • 2002
  • In this study, a method for the localization of pregnancy-specific proteins from cow urine on 2-D gel have been established. The proteins were digested with trypsin in gel and then analyzed with MALDI- TOF or transferred to a membrane and microsequenced. To examine the pregnancy associated protein spot 2 as a diagnosis marker in bovine urine 2-D western blotting was performed. This antibody was reacted specifically in the protein of pregnant cow’s urine. Consequently spot 2 was identified and found to be good candidates for developing cow pregnancy detection assay kit.

  • PDF

MR Angiography with Simultaneous Data Acquisition of Arteries and Veins(SAAV) method and Artery-Vein Color Mapping in 0.3T MR system

  • 조종운;조지연;문치웅
    • Proceedings of the KSMRM Conference
    • /
    • 2002.11a
    • /
    • pp.104-104
    • /
    • 2002
  • 목적: SAAV sequence를 이용하여 동시에 획득한 동맥과 정맥의 두 MRA 영상을 Color Mapping으로 동맥과 정맥을 구분하여 한 영상에 나타냄으로써 AVM 이나 DAVF 등과 같은 혈관질환의 임상적 진단 및 치료에 도움을 주고자 하였다. 대상 및 방법: 일반적으로 MRA 영상은 사전 포화방법(presaturation)을 이용한 2D TOF 기법을 통하여 동맥과 정맥을 구분하여 영상을 획득한다. 이러한 일반적인 사전포화방법을 응용한 SAAV 기법은 일정영역을 미리 포화(saturation)시킨 후 포화영역의 위, 아래의 영역을 한번에 영상화하여 동맥과 정맥의 구분된 영상을 한번에 획득할 수 있다. 마산 삼성병원의 0.3T MRI system(Megfinder, AILab. Korea)에서 SAAV sequence를 이용하여 정상적인 피험자로부터 목 부위의 동맥과 정맥 혈관영상을 동시에 얻었다. 이들의 각 2D 영상을 Color Mapping으로 조합한 후 Maximum Intensity Projection(MIP) 기법을 통해 3D Artery-Vein Color Mapping(AVCM) MRA 영상으로 재구성하였다. 3명의 피험자에 대한 SAAV MRA data를 256$\times$256$\times$64(resolution: 0.89$\times$0.89$\times$2㎣)로 획득하였다.

  • PDF