• 제목/요약/키워드: TOC removal

검색결과 217건 처리시간 0.024초

생물막 여과에 의한 지하수중 질산성 질소의 제거 (Removing Nitrate from Groundwater by Biofilm Filtration)

  • 이용두;고인범
    • 상하수도학회지
    • /
    • 제12권2호
    • /
    • pp.83-89
    • /
    • 1998
  • The drinking water supply in Cheju entirely depends on the ground water and recently the polluted ground water bores are increasing. In 1993 Cheju Province Health-Environment Institute reported that the ground water quality of 26 of 98 bores under the drinking water quality standard. Therefore there are many investigation in the needs of the nitrate removal in the drinking water in the regin with no alternative water resources. In this study, the following results are obtained to remove the nitrate in biofilm filtration process in which uses ethanol as external carbon source. Over 90% of nitrate is removed after 10 days of experiment. The nitrate removal rate on filtration velocity is about 100% at 50m/day and 100m/day, and about 56% at 200m/day. The removal rate is reduced in 27% at 400m/day. Using ethanol as the external carbon source, denitrification kinetic is 1st-order. Denitrification constant k is 8.004($hr^{-1}$). The amount of the denitrificated-Nitrogen is increased as the contact time increased. Deoxydation rate constant ${\gamma}$ is 11.895($hr^{-1}$). 0.968g of ethanol(as TOC) is needed to remove 1g of nitrate and 0.291g is required to remove 1g of dissolved oxygen.

  • PDF

NF와 RO를 이용한 지하수중 용존성 물질의 제거와 막 오염의 특성에 관한 연구 (A Study on the Removal of Dissolved Matter in Groundwater and Characteristics of Fouling using NF and RO)

  • 권은미;유명진
    • 대한환경공학회지
    • /
    • 제22권12호
    • /
    • pp.2205-2213
    • /
    • 2000
  • NF와 RO를 이용한 용존성 물질의 제거특성을 관찰하기 위해 UF로 전처리된 지하수가 파일럿플랜트에 6개월 동안 연속 공급되었다. 그리고 NF와 RO에서 발생한 막 오염의 특성을 파악하고 막 오염물질을 규명하기 위해서 파일럿플랜트에서 NF와 RO를 분리하여 autopsy test를 실시하였다. Autopsy test에서는 파일럿플랜트에서 사용된 막의 투과플럭스와 화학세정에 따른 플럭스의 회복율을 측정하였다. 아울러 여기서 발생한 폐세정액의 수질을 분석하여 막 오염물질의 구성성분을 알아보고자 하였다. NF와 RO1의 비플럭스는 운전시간 100일 이후에 급격히 감소하기 시작하였고 RO1에서의 감소율이 NF에서보다 컸다. 회수율이 낮온 RO2의 비플럭스는 점진적으로 감소하였다. 파일럿플랜트에서 용존성 무기물질의 제거율은 전기전도도로 NF, RO1, RO2 막에서 각각 76.3%, 88.2%, 95.3%로 RO2에서 가장 높았다. 용존성 유기물질의 제거율은 TOC로 80%정도였다. 와권형 NF와 RO의 막 오염은 원수 유입부보다는 농축수 유출부에서 많이 발생하였다. 이것은 유출부로 갈수록 막면선속도가 낮아지고 원수 중 오염물질의 농도가 높아졌기 때문이다. 막 오염물질의 주성분은 무기성 Ca염과 유기성 Si염인 것으로 생각되며 비가역적 막 오염에 기여도가 가장 큰 물질은 Fe인 것으로 생각된다. 막 오염물질의 형상을 SEM으로 관찰한 결과 최근접 표면에 유기물질이 부착되어 있고 그 위에 판상모양의 무기성분이 쌓여 있는 형태가 관찰되었다. 미생물 막 오염은 거의 관찰되지 않았는데 이것은 UF에서 1차로 대부분의 미생물이 제거되었기 때문이다.

  • PDF

식생이 조성된 LID 시설의 효율 평가 (Assessment of Performances of Low Impact Development (LID) Facilities with Vegetation)

  • 홍정선;김이형
    • Ecology and Resilient Infrastructure
    • /
    • 제3권2호
    • /
    • pp.100-109
    • /
    • 2016
  • 도시 지역의 물순환 구축과 비점오염물질 저감을 위해 구축되는 LID 시설의 지속적 효율은 주요 내부 구성요소(식물, 토양, 여재, 미생물 등)의 최적화된 상호작용에 의하여 나타난다. 본 연구는 식생이 조성된 4가지 LID 기술 (식생체류지, 소규모 인공습지, 빗물정원 및 나무여과상자)의 실제 도시 강우유출수의 유입으로 인한 식물의 성장상태 변화와 물순환 효과 및 비점오염물질 저감능력을 평가하기 위하여 수행되었다. 도시지역의 강우유출수의 약 40% 이상의 유출저감을 위한 적정 SA/CA (facility surface area / catchment area) 비는 시설마다 차이는 있지만 1~5% 범위가 적당한 것으로 평가되었다. 강우시 LID 시설에서의 유출저감은 비점오염물질 저감효율 향상에 중요한 영향을 끼치는 기작으로 나타났으며, SA/CA는 LID 시설의 중요한 설계인자로 도출되었다. 유출저감에 효과적인 시설은 빗물정원 > 나무여과상자 > 식생체류지 > 소규모 인공습지 순으로 나타났으며 입자상 물질 (TSS)의 제거능력은 빗물정원 > 나무여과상자 > 소규모 인공습지 > 식생체류지 순으로 분석되었다. 유기물 (COD, TOC), 영양물질 (TN, TP) 및 중금속 (Cu, Pb, Cd, Zn) 제거에는 빗물정원 > 나무여과상자 > 식생체류지 > 소규모 인공습지 순으로 조사되었으며 이러한 결과들은 향후 도시지역의 물순환 구축 및 비점오염물 제거에 적용되는 LID 시설의 설계에 중요한 자료로 활용 가능할 것으로 판단된다.

Phenol 분해균주의 분리 및 페놀함유 폐수의 생물학적 처리 (Isolation of a Phenol-degrading Bacterial Strain and Biological Treatment of Wastewater Containing Phenols)

  • 이현돈;이명은;김형갑;서현효
    • 생명과학회지
    • /
    • 제23권10호
    • /
    • pp.1273-1279
    • /
    • 2013
  • 방향족화합물들로 오염되어있는 토양 및 산업폐수를 포함한 각종 시료로부터 phenol에 분해활성이 높은 56균주를 순수분리 하였으며, 이들 분리 균주 중 균체생육과 phenol 분해활성이 가장 높은 균주인 GN13을 선별하였다. 분리균주 GN13은 형태학적, 생리학적 및 생화학적 특성을 조사한 결과 Neisseria 속 세균과 유사한 것으로 판명되어 최종적으로 Neisseria sp. GN13으로 명명하였다. 분리균주 Neisseria sp. GN13의 균체생육 및 phenol 분해를 위한 최적온도와 최적 pH는 각각 $32^{\circ}C$와 7.0였다. 유일 탄소원으로 phenol 1,000 mg/l를 포함하여 최적화된 배지를 사용한 jar-fermentor 배지에서 배양 30시간에 균체생육이 최대에 이르렀으며 배양 27시간째 거의 모든 phenol이 분해되었으며, catechol deoxygenase 활성측정에 의하여 Neisseria sp. GN13은 meta-와 ortho-pathway를 통하여 catechol 분해가 일어났다. Neisseria sp. GN13은 phenol 함유 인공폐수에서의 phenol 분해율은 배양 30시간 만에 97%의 phenol이 분해되는 것으로 나타났으며, 인공폐수에 대한 Neisseria sp. GN13과 활성슬러지 처리구에서의 TOC 제거효율은 각각 83%와 78%였다. 석유화학폐수에 대한 Neisseria sp. GN13의 COD 제거율은 활성슬러지만을 포함한 대조구보다 약 1.3배 높은 효율을 나타내었다. 이러한 결과로 미루어 분리균주 Neisseria sp. GN13은 phenol을 함유하고 있는 여러 폐수에 효과적으로 적용될 수 있을 것으로 생각된다.

생물막공정에 의한 상수원수의 수질개선에 관한 연구 (A Study on the Quality Improvement of Raw-Water Using Submerged Biofilter)

  • 이수식;안승섭
    • 상하수도학회지
    • /
    • 제13권1호
    • /
    • pp.81-94
    • /
    • 1999
  • This study aims at a proposal of the plan that can improve raw water quality by an experimental study using influent water of Nak-dong river, which has been used as raw water for drinking in U-city, through the establishment of the submerged biofilter process PILOT PLANT of media packing channel method. From the analysis of removal efficiency for each water quality item of the collected sample, following results are obtained. First of all, the removal rate of suspended material, BOD, COD, T-N, TOC, turbidity, and $NH_3$ -N appear 82%, 78%, 42%, 15%, 57%, 43%, 54%, and 55% respectively and it is known that the submerged biofilter process of media packing channel method takes effects on water quality improvement from the above analysis results of water treatment efficiency. And the analyzed results for water temperature, residence time, and activities of microorganism, which can be the factors affect on water quality improvement, are as follows. 1) The removal rate variation of SS, BOD, and COD attendant on water temperature change is examined and it is known that the removal rate increases at $13^{\circ}C$ or above. 2) The removal rate of SS, BOD, and COD attendant on residence time is most active in the range of 0~18hr, 0~1.8hr, 0~2.7hr respectively, so it is found that the removal rate becomes smaller after 2.7hr. 3) From the examination of microorganism activity with the abundance of normal bacteria, it is found that the floating bacteria decrease as the flow distance from raw water inflow point of PILOT PLANT increases, and the adhesive bacteria have no concern with the flow distance. And it its known that the biomass of fine algae decreases as the flow distance from the raw water inflow point of PILOT PLANT increases from the examination with Chl-a.

  • PDF

사진현상폐수의 UV-자유반사 반응조에서의 UV/H2O2 고급산화처리 (UV/H2O2 Advanced Oxidation of Photo Processing Chemicals in a UV-free Reflecting Reactor)

  • 최경애;김영주
    • 대한환경공학회지
    • /
    • 제22권2호
    • /
    • pp.241-249
    • /
    • 2000
  • 난분해성 폐수인 사진현상폐수의 $UV/H_2O_2$$H_2O_2$의 고급산화에 의한 오염물질의 제거 실험을 실시하였다. $UV/H_2O_2$ 산화에서 $H_2O_2$의 분해로 $OH^-$ 라디칼이 발생되는데 파장 190~300 nm의 UV가 반응의 촉매 역할을 한다. $OH^-$ 라디칼은 수명은 짧으나 강력한 산화력을 갖고 있는데, 이 산화력은 폐수처리에서 폐수나 액상 폐기물의 유기물질을 제거하는데 이용된다. 본 연구에서 기존의 tube형 반응조의 단점을 보완한 UV-자유반사 반응조를 제작하여 사용하였으며 UV원으로는 수은 고압램프가 이용되었다. 본 실험에서는 반응시간과 $H_2O_2$ 주입량 및 pH 변화에 따른 오염물의 처리효율의 변화를 조사하였는데 $H_2O_2$의 주입량이 증가할수록 처리효율이 높았으나 그 차이는 미미하였으며, pH 8에서 보다는 3에서 처리효율이 약간 높았으나 그 차이 역시 크지 않았다. 본 연구에서 사진현상폐수 처리의 적정 운전조건은 pH 8, $H_2O_2$ 주입량은 유입수의 COD를 기준으로 한 1.3배 화학량론적 주입으로 나타났는데, 5시간의 처리에서 $COD_{Cr}$, TOC 및 색도의 제거효율은 각각 약 47.5%, 75.0% 및 91.5%로 나타났다. 반응 후 생분해성의 지표인 BOD/COD 비는 초기 0.04에서 0.21로 약 5.3배 증가하였다.

  • PDF

물리화학적 공정에 의한 용존성 Humic Acid의 제거 (Removal of Dissolved Humic Acid with Physicochemical Treatment Process)

  • 김종식;최준호
    • 공업화학
    • /
    • 제10권5호
    • /
    • pp.737-742
    • /
    • 1999
  • THMs의 전구물질로 잘 알려진 humic acid를 대상으로 오존처리, 응집처리 및 활성탄 흡착처리와 같은 물리화학적 처리공정 도입에 따른 humic acid의 제거특성을 조사하고, 염소주입시 생성 가능한 부산물을 정성적으로 규명하기 위하여 본 연구를 실시하였다. Humic acid에 오존을 주입한 결과 pH가 급격히 감소하였는데, 이는 분자량이 큰 humic acid가 오존에 의하여 $H_2O$$CO_2$로 완전히 산화되지 못하고 중간생성물인 저급 지방산으로 분해된 결과로 판단되었다. 그리고 용존성 humic acid의 응집특성을 조사하기 위하여 PAC 160 mg/L로 응집을 실시한 결과 TOC는 약 25%, $COD_{Cr}$는 24%가 제거되었으나, 색도는 단지 5%만이 제거되어, humic acid에 의해 유발되는 색도는 응집으로 제거하기 어려운 것으로 판단되었다. 그러나 오존처리에서는 95% 이상의 색도가 제거되었으며, 이때 색도는 오존 접촉시간에 대해 1차반응으로 제거되었고, 반응속도상수값 k는 $0.067min^{-1}$로 조사되었다. 활성탄 흡착 실험에서는 오존 전처리를 실시함으로써 활성탄 흡착 효율이 크게 증가함을 확인할 수 있었으며, humic acid에 염소를 주입한 결과 THMs만 검출되었을 뿐 다른 휘발성 미량 유기화합물은 검출되지 않았고, 오존처리를 실시한 오존처리수에서도 알데히드류 및 케톤류와 같은 부산물은 검출되지 않았다.

  • PDF

음식물 쓰레기 및 황토 혼합물의 열분해를 통한 수질정화용 다공성 담체 개발 (Development of Porous Media for Sewage Treatment by Pyrolysis Process of Food Wastes with Loess)

  • 김상범;이명화;김용진;박철환;이종래;김경수
    • 대한환경공학회지
    • /
    • 제29권3호
    • /
    • pp.289-296
    • /
    • 2007
  • 본 연구에서는 음식물 쓰레기를 황토와 혼합하여 고온 열분해 과정을 거쳐 다공성 담체를 제조하고, 이를 하수처리용 담체로 적용하고자 하였다. 이에 열분해 장치를 이용하여 다공성 담체를 제조하는 1단계 실험과 실험실 규모의 하수처리 장치에 이 다공성 담체를 충진하여 수처리 효율을 분석하는 2단계로 실험을 진행하였다. 다공성 담체 제조를 위한 열분해 장치의 최적 운전조건을 결정하기 위하여, 1단계 실험에서 열분해 장치의 온도조건과 음식물 쓰레기와 황토의 혼합비를 달리하여 각각의 조건에서 제조된 다공성 담체의 비표면적, 기공률, 압축강도 등의 물리적 특성을 확인하였다. 그 결과로서 음식물 쓰레기와 황토의 혼합비 1:1, 열분해 온도조건 $1,100^{\circ}C$가 최적 운전조건인 것으로 나타났다. 2단계 실험에서는 제조된 다공성 담체에 대하여 수질정화용으로서의 적용가능성을 평가하였으며, 그 결과 실험시작 8일째부터 TOC 87.3%, COD 85.0%의 처리효율을 가지는 것으로 나타났다. 또한 전체 기공률 37.0% 와 $1\sim20{\mu}m$ 사이의 기공크기를 가지는 구조내에서 미생물 활성화가 활발하게 이루어지고 있는 것을 확인할 수 있었다.

무산소 조건에서의 인섭취를 이용한 생물학적 영양염류 제거 (Biological Nutrient Removal by Enhancing Anoxic Phosphate Uptake)

  • 이대성;전체옥;박종문
    • 대한환경공학회지
    • /
    • 제22권5호
    • /
    • pp.861-867
    • /
    • 2000
  • 무산소 조건에서의 인섭취를 이용한 질소, 인 화합물의 동시 제거 가능성을 연속회분식반응기(SBR)를 사용하여 고찰하였다. 혐기-호기상의 AO SBR 반응기에 점차적으로 무산소상을 도입함으로써 질산염을 전자수용체로 사용하여 탈질이 가능한 인섭취 미생물들(DPAOs)을 다량으로 축적하였다.(혐기-호기-무산소-호기상의 $(AO)_2$ SBR). 무산소상과 호기상에서의 인섭취율을 비교해 보았을 때, 전체 인제거 미생물 내에서 DPAOs의 비율이 약 10%에서 64%까지 증가하였다. $(AO)_2$ SBR은 안정된 질소, 인제거 성능을 보였으며, 유기물질, 질소, 인 화합물의 제거율은 각각 92%, 88%, 100%였다. $(AO)_2$ SBR의 운전결과와 회분식 실험으로 부터 아질산염은 무산소상에서의 인제거 반응에 어떠한 악영향도 미치지 않으며, 오히려 질산염과 함께 전자 수용체로 사용되어짐을 알 수 있었다.

  • PDF

영가철/바이오 복합처리제를 이용한 질산성 질소 오염 지하수의 현장 지중정화 적용성 평가 (Field Assessment of in Situ Remediation of NO3--contaminated Ground Water Using Zero-valent Iron/Bio Composite Media)

  • 주완호;장윤영
    • 환경영향평가
    • /
    • 제30권1호
    • /
    • pp.35-48
    • /
    • 2021
  • 본 연구에서는 예산군에 위치한 질산성 질소 오염 지하수 부지를 대상으로 오염지하수의 지중정화현장 적용성 평가를 수행하고자, 영가철/바이오 환경정화소재를 이용한 Injected PRB(Permeable Reactive Barrier)와 관측정을 현장 오염지하수부지에 적용하고 주요 정화지표에 대한 변화를 모니터링하였다. 질산성질소, 아질산성질소, 암모니아성질소, 철 이온, TOC, 탁도 등의 항목 등을 조사하고 미생물 분석을 실시하여 지중정화기술의 현장 적용성을 평가하였다. 연구대상 부지는 농경지역으로 북쪽 경계는 하천이 서쪽에서 동쪽으로 흐르며 하천 경계를 형성하고 남쪽은 불투수 경계로 이루어져 있다. 질산성질소는 전반적으로 지하수 흐름과 유사하게 하천으로 흐르는 것으로 분석되었다. 모델링 결과, 약 3년에서 5년정도 경과 후 안정 상태로 도달하는 것으로 판단되었다. 이는 추가적인 오염원 유입이 없는 현재 상태만 고려한 것으로 지속적 오염이 유입된다면 오염범위 및 안정화 기간이 증가할 수 있다. 모니터링 결과, PRB설치 전, 후 철 이온, TOC, 탁도 값이 큰 차이를 보이지 않아 PRB의 음용수 관정 영향은 없는 것으로 판단되어 해당 지중정화기술의 지중 주입 적합성을 확인하였다. 질산성질소는 PRB 설치 42일 차까지 5 mg/L보다 낮은 농도가 유지되었으나 84일 차부터 PRB 내부의 질산성질소 제거 유효 기간이 끝나 원래의 농도를 회복하였다. PRB 설치 후 아질산성 질소와 암모니아성 질소의 검출은 PRB에 의한 질산성 질소의 환원에 의한 감소를 보여주었으며, 미생물 분석 결과 종 다양성이 증가하고 탈질 미생물을 포함하고 있는 Betaproteobacteria Class 군집이 크게 증가한 결과는 질산성 질소가 생물학적 환원작용에 의한 정화 가능성도 보여주었다.