• Title/Summary/Keyword: TOC removal

Search Result 217, Processing Time 0.024 seconds

Removal of Total Organic Carbon and Micropollutants in Tertiary Treated Sewage by Medium Pressure UV/H2O2 (중압 자외선과 과산화수소 공정을 이용한 하수 3차 처리수중 총유기탄소와 미량오염물질 제거)

  • Lee, Jai-Yeop;Kim, Ilho
    • Journal of Korean Society on Water Environment
    • /
    • v.36 no.4
    • /
    • pp.314-321
    • /
    • 2020
  • This study evaluated the applicability of UV-AOP process using medium-pressure UV lamp and H2O2 to remove TOC and emerging micropollutants in the effluent from a sewage treatment plant. The UV lamp with higher output(1.6~8.0 kW) showed slightly higher amount of power in removing TOC of 1 mg/L(0.09 kWh/mg/L~0.11 kWh/mg/L), however it was found that there was no significant difference for each cases. In addition, under the condition that the H2O2 concentration is sufficient, as the power consumption of the UV lamp increases, the unit TOC removal concentration per unit H2O2 decomposition concentration also increases, resulting in effective removal of TOC. The removal rate of 7 new trace contaminants, such as antibiotics by the UV-AOP tested, was at least 89.4%, and the ability to remove the emerging micro pollutants in the process was very effective. But, it was judged that it could not be excluded that the probablity of transforming to oxidated by-product in the case of a low TOC removal efficiency. Depending on the operating conditions of the UV and H2O2 processes, a higher BOD concentration is found in the treated water than in the influent, and it is necessary to review the UV power and proper injection conditions of H2O2 to maintain the BOD concentration increase below a certain level.

A study on operation and management for TOC removal of public sewage treatment works (하수처리시설에서 총유기탄소(TOC) 처리를 위한 운영·관리 고찰)

  • Jeong, Dong-Hwan;Chung, Hyenmi;Cho, Yangseok;Kim, Eunseok;Kim, Changsoo;Park, Junwon;Lee, Wonseok
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.32 no.6
    • /
    • pp.535-550
    • /
    • 2018
  • Total organic carbon (TOC) will replace chemical oxygen demand ($COD_{Mn}$) as an effluent water quality standard in public sewage treatment works (PSTWs) from 2021 in Korea. To ensure effective control of TOC in the effluent, investigation was carried out into TOC levels and sewage treatment operation factors in five target PSTWs using anaerobic-anoxic-aerobic ($A_2O$) processes, media, membrane, and sequencing batch reactor (SBR) technologies. TOC removal efficiencies appeared to be 93-96% on average. As a fraction of TOC, biodegradable dissolved organic carbon (BDOC) was reduced from 64% in the influent to 9% in the effluent in these PSTWs. During the investigation, biological treatment processes were applied flexibly for operation factors such as HRT, SRT, MLSS, F/M ratios and BOD volume loads, based on the influent characteristics and design conditions. As a result, we suggest efficient operating conditions in PSTWs by evaluating relationships between TOC removal and operation factors.

A Comparison of N and P Removal Characteristics by the Variation of Non-aeration Time in A2O SBBR (A2O SBBR에서 비포기 시간 배분에 따른 질소-인 제거 특성 비교)

  • Park, Young-Seek;Jeong, No-Sung;Kim, Dong-Seog
    • Journal of Environmental Science International
    • /
    • v.16 no.7
    • /
    • pp.813-821
    • /
    • 2007
  • Laboratory scale experiments were conducted to investigate the removal characteristics of nitrogen and phosphorus in two sequencing batch biofilm reactors (SBBRs). SBBR1 had a short first non-aeration period and SBBR2 had a long first non-aeration period. The removal characteristics of nitrogen and phosphorus in each SBBR were precisely observed according to the variation of influent TOC concentration, and the operation control parameters (pH, DO concentration, ORP) in each reactor were measured. In biological nitrogen removal, there was little difference between SBBR1 and SBBR2 and the nitrogen removal efficiencies were very low. The nitrogen and phosphorus removal characteristics in high influent TOC concentration were different from those in low TOC. Nitrogen removals by simultaneous nitrification/denitrification (SND) were occurred in both SBBR1 and SBBR2. The P removal in SBBR1 was superior to that in SBBR2. The second P release was observed in SBBR1 which had long second non-aeration period.

Preparation and Characteristics of Immobilized Sludge by the PAA Entrapment Method (PAA 포괄법에 의한 고정화 슬러지의 제조 및 특성에 관한 연구)

  • 최석순
    • Journal of Environmental Health Sciences
    • /
    • v.28 no.3
    • /
    • pp.49-54
    • /
    • 2002
  • This study was conducted to evaluate the feasibility and characteristics of poly acrylamide (PAA) immobilized sludge as a microbial entrapment bead for wastewater treatment. In the PAA method of immobilized sludge, it was found that the optimum acrylamide concentration for actual wastewater treatment was to be 12%. When the sequencing batch reactor (SBR) was operated during 30 days, removal efficiencies of TOC and phosphate was 95% and 70ft, respectively. From this research, repeated cycle of anaerobic and aerobic conditions is required to enhance the removal of TOC and phosphate. During the operation, immobilized cells could be used without being disrupted.

Outlier Detection and Treatment for the Conversion of Chemical Oxygen Demand to Total Organic Carbon (화학적산소요구량의 총유기탄소 변환을 위한 이상자료의 탐지와 처리)

  • Cho, Beom Jun;Cho, Hong Yeon;Kim, Sung
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.26 no.4
    • /
    • pp.207-216
    • /
    • 2014
  • Total organic carbon (TOC) is an important indicator used as an direct biological index in the research field of the marine carbon cycle. It is possible to produce the sufficient TOC estimation data by using the Chemical Oxygen Demand(COD) data because the available TOC data is relatively poor than the COD data. The outlier detection and treatment (removal) should be carried out reasonably and objectively because the equation for a COD-TOC conversion is directly affected the TOC estimation. In this study, it aims to suggest the optimal regression model using the available salinity, COD, and TOC data observed in the Korean coastal zone. The optimal regression model is selected by the comparison and analysis on the changes of data numbers before and after removal, variation coefficients and root mean square (RMS) error of the diverse detection methods of the outlier and influential observations. According to research result, it is shown that a diagnostic case combining SIQR (Semi - Inter-Quartile Range) boxplot and Cook's distance method is most suitable for the outlier detection. The optimal regression function is estimated as the TOC(mg/L) = $0.44{\cdot}COD(mg/L)+1.53$, then determination coefficient is showed a value of 0.47 and RMS error is 0.85 mg/L. The RMS error and the variation coefficients of the leverage values are greatly reduced to the 31% and 80% of the value before the outlier removal condition. The method suggested in this study can provide more appropriate regression curve because the excessive impacts of the outlier frequently included in the COD and TOC monitoring data is removed.

Photo and Electrocatalytic Treatment of Textile Wastewater and Its Comparison

  • Singaravadivel, C.;Vanitha, M.;Balasubramanian, N.
    • Journal of Electrochemical Science and Technology
    • /
    • v.3 no.1
    • /
    • pp.44-49
    • /
    • 2012
  • Electrochemical and photochemical techniques have been proved to be effective for the removal of organic pollutants in textile wastewater. The present study deals with degradation of synthetic textile effluents containing reactive dyes and assisting chemicals, using electro oxidation and photo catalytic treatment. The influence of various operating parameters such as dye concentration, current density, supporting electrolyte concentration and lamp intensity on TOC removal has been determined. From the present investigation it has been observed that nearly 70% of TOC removal has been recorded for electrooxidation treatment with current density 5 mA/$dm^2$, supporting electrolyte concentration of 3 g/L and in photocatalytic treatment with 250 V as optimum lamp intensity nearly 67% of TOC removal was observed. The result indicates that electro oxidation treatment is more efficient than photocatalytic treatment for dye degradation.

Fundamental Study on the Removal Properties of Polyethylene Glycols by Mesh Filtration Batch Bio-reactor (메쉬 침지여과분리형 회분식 생물반응조를 이용한 PEG제거의 기초 연구)

  • Jung, Yong-Jun
    • Journal of Korean Society on Water Environment
    • /
    • v.25 no.4
    • /
    • pp.502-506
    • /
    • 2009
  • The removal properties of Polyethylene glycols (PEGs) known as the important group of synthetic polymers of ethylene oxide were examined by the bio-reactor equipped with a mesh filter module. PEG-1000 and PEG-2000 were fairly removed on the basis of TOC, which were 75.1% and 51.6%, respectively. In the case of PEG-20000, the removal efficiency of TOC was less than 15.2% and the favorable acclimation of microbes was not obtained. It was suggested that this system could effectively maintain microbes for the biodegradation of low molecular weight of PEG and TOC removal was significantly influenced by PEG molecular weight.

Reduced Post-Chlorine Dosage Required for Disinfection: Improvement with Ozonation and GAC Process (오존 및 입상활성탄 도입시 후염소 주입량 저감효과 분석)

  • Baek, Young-Ae;Joe, Woo-Hyeun;Kim, Jong-Moon;Choi, Young-Jun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.21 no.4
    • /
    • pp.445-452
    • /
    • 2007
  • This study was carried out to examine effect of post-chlorine dosage reduction by ozonation and GAC process in the field plant for 3years in the "G" water purification plant in Seoul. And it is to compare GAC with BAC process in removal effects of TOC, THMs, THMFP, $UV_{254}$. As a result, chlorine dosage of ozonation and GAC(=BAC) is less demand than GAC. Seasonal reduction of chlorine demand is from about 37% to 59% with BAC, and from 24 to 46% with GAC. Higher reduction in BAC could be achieved. The efficiency of chlorine demand reduction with ozonation was depending on the organic carbon removal. $UV_{254}$ concentration is less about 0.13~0.74L/mg.m in BAC than GAC. Therefore, the combination of ozonation and GAC was more effective in reducing post-chlorine than the single GAC. TOC was also monitored, and results show that a linear relationship between TOC and chlorine demand is appropriate under each treatment process. It means that removal of organic matter(TOC) from finished water is necessary to reduce post-chlorine dosage in clear well and to minimize order of chlorine in distribution systems.

Performance Evaluation for the A/O Pure-Oxygen Biofilm (POB) Process on the Removal of Organics and TKN in the Industrial Wastewater (혐기/호기 순산소 생물막공법에 의한 산업폐수의 유기물 및 TKN 제거 성능평가)

  • Jang, Am;Kim, Hong Suck;Kim, In S.
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.5
    • /
    • pp.837-847
    • /
    • 2000
  • For the treatment of wastewaters generated from beer industry and petrochemical company with high organic and nitrogen contents, laboratory scale of A/O Pure-Oxygen Biofilm (POB) process was developed and studied by means of the comparative economic analysis with extended aeration process. When the wastewater of beer company was initially treated by the A/O POB process in the ranges of 70 to 150 mg TOC/L diluted with tap water, higher than 92% of TOC removal was accomplished in the all ranges. In case of petrochemical wastewater, the initial TOC removal was as low as 52%, though, it increased to 86% after 32 days of operation and also the TKN removal marked 71% after 27 days. Continuous high removal rates were monitored in both the TOC and TKN parameters during the experimental period. Due to the cost for PSA (Pressure Swing Adsorption) setting and biomass supporting media installation, the initial construction cost of A/O POB process was 2.9 times higher than that of extended aeration process. However, the advantages such as low sludge production, no need for sludge recycling and low energy consumption allow the A/O POB process to have 2.5 times lower operation and maintenance costs. Consequently, in the long term of operation, it is likely that A/O POB process would show higher performance as well as cost effectiveness compared to extended aeration process.

  • PDF

Effects of Recycled Washwater on Pollutant Removal and Particle Characteristics during Coagulation (회수수가 응집공정의 오염물질 제거 및 입자특성에 미치는 영향)

  • 문병현;김승현;박미선;이향인;이강춘
    • Journal of Environmental Science International
    • /
    • v.11 no.9
    • /
    • pp.955-960
    • /
    • 2002
  • The recycled washwater, which has different water quality and is produced about 5 to 20% of the total water volume treated, affects the unit operation of water treatment, especially coagulation process. However, the effects of recycled washwater on unit operation of water treatment have not been fully investigated. In this study, effects of recycled washwater on coagulation process were investigated to find the optimum coagulation condition by analyzing turbidity, $UV_{254}$, TOC removal efficiencies. In addition, effects of recycled washwater on residual Al after coagulation were studied by analyzing soluble and particulate Al. The size distribution and fractal dimension of coagulated also analyzed. The recycled washwater was lower pH than the raw water. And the recycled washwater had higher $UV_{254}$, TOC and residual Al concentration than the raw water. Residual Al concentration of recycled washwater was about 50 times higher than that of raw water. Optimum coagulant dosages on the blending recycled washwater and the raw water for turbidity, $UV_{254}$ and Al removal were lower than that on the raw water. However, TOC removal increased by increasing coagulant dosage. The size and fractal dimension of coagulated particle produced in the blending recycled washwater were larger, which imply faster settling velocity, than those produced in the raw water only.