• Title/Summary/Keyword: TOC (Total Organic Carbon)

Search Result 268, Processing Time 0.025 seconds

Outlier Detection and Treatment for the Conversion of Chemical Oxygen Demand to Total Organic Carbon (화학적산소요구량의 총유기탄소 변환을 위한 이상자료의 탐지와 처리)

  • Cho, Beom Jun;Cho, Hong Yeon;Kim, Sung
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.26 no.4
    • /
    • pp.207-216
    • /
    • 2014
  • Total organic carbon (TOC) is an important indicator used as an direct biological index in the research field of the marine carbon cycle. It is possible to produce the sufficient TOC estimation data by using the Chemical Oxygen Demand(COD) data because the available TOC data is relatively poor than the COD data. The outlier detection and treatment (removal) should be carried out reasonably and objectively because the equation for a COD-TOC conversion is directly affected the TOC estimation. In this study, it aims to suggest the optimal regression model using the available salinity, COD, and TOC data observed in the Korean coastal zone. The optimal regression model is selected by the comparison and analysis on the changes of data numbers before and after removal, variation coefficients and root mean square (RMS) error of the diverse detection methods of the outlier and influential observations. According to research result, it is shown that a diagnostic case combining SIQR (Semi - Inter-Quartile Range) boxplot and Cook's distance method is most suitable for the outlier detection. The optimal regression function is estimated as the TOC(mg/L) = $0.44{\cdot}COD(mg/L)+1.53$, then determination coefficient is showed a value of 0.47 and RMS error is 0.85 mg/L. The RMS error and the variation coefficients of the leverage values are greatly reduced to the 31% and 80% of the value before the outlier removal condition. The method suggested in this study can provide more appropriate regression curve because the excessive impacts of the outlier frequently included in the COD and TOC monitoring data is removed.

Characteristics and Effective Usage of Organic Indexes in Water Environments -Lakes in Nakdong River Basin- (물환경에서의 유기물질 지표 특성 및 효율적 이용방안 -낙동강수계 호소수를 대상으로-)

  • Kang, Meea
    • Journal of Wetlands Research
    • /
    • v.16 no.1
    • /
    • pp.153-160
    • /
    • 2014
  • TOC environmental standard was established to understand the pollution level accurately and to improve the water quality. It was found that the relationship between COD and TOC showed a significant coefficient($R^2$=0.639) in four lakes for drinking water located in Nakdong River basin. The relationship between COD and TOC($R^2$=0.774) was higher with respect to the elevated concentration level when the data was added. Resulting in the oxidation(C) was $62{\pm}8%$ regardless of COD concentrations. It was difficult to find a significant difference by lakes. The result showed the similar organic property in study lakes. It was necessary to evaluate the level of organic matters in consideration of characteristics and utilization of lakes to use COD data wisely until TOC data be accumulated sufficiently.

지하수의 채취 및 전처리 방법에 따른 TOC 농도변화

  • 조수영;윤윤열;이길용;김용재
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2004.09a
    • /
    • pp.413-416
    • /
    • 2004
  • TOC(total organic carbon)분석은 폐수 및 강수의 오염특성을 평가하기 위한 도구로서 BOD(biochemical oxygen demand), COD(chemical oxygen demand) 와 함께 사용되어 왔다. TOC 측정시간은 10분 정도로 BOD(5~6일), COD(2~3시간)에 비해 아주 짧은 시간에 측정할 수가 있으며, 전처리과정이 단순하고 정확도도 높은 것으로 알려져 있다. 본 연구는 지하수의 잠재오염성을 밝혀내기 위한 도구로 TOC를 활용하여 신뢰성 있는 분석 값을 얻기 위해서 시료의 채취, 보관, 측정까지의 최적 조건을 도출하는데 목적을 두었다. 아울러 시료 채취 후 일정 경과 시간에 따른 TOC의 변화를 관찰하였다. 시료채취 용기, 채취 후 산성화, 보관방법 및 기간에 대한 실험 결과, 대상 변수에 따라서 TOC의 농도변화에 커다란 차이점을 볼 수 있었다. TOC 농도가 낮은 지하수시료의 측정에서는 빛을 차단시킨 불투명 유리병을 사용해야만 하고 채취 즉시 산도를 높여(pH<2)주며 4$^{\circ}C$ 이하에서 보관하여야 한다. 지하수중 TOC 측정시료는 가능한 보관 기간에 있어서 채수 후 24시간 이내에 측정하는 것이 좋으나 1) 본 연구에서는 채취현장과의 거리를 고려하면 현실적으로 불가능하므로 기간에 따른 TOC 변화를 30일까지 측정, 조사하였다.

  • PDF

Improvement of Water Treatment Efficiency by pH Decreasing Agent (H2SO4) for Droughty Seasons (갈수기 정수장운영관리 사례 - 갈수기 pH저감제(황산)투입에 의한 정수처리효율 향상)

  • Ka, Gilhyun;Kim, Yunyung;Lee, Junho;Ahn, Chihwa;Han, Ihnsup;Min, Byungdae
    • Journal of Korean Society on Water Environment
    • /
    • v.24 no.4
    • /
    • pp.415-422
    • /
    • 2008
  • Drinking water treatment is enhanced by coagulant dosages and chlorine injection because of pH increase in raw water in droughty seasons such as spring and fall. But water quality deterioration is occurred by increase in residual aluminium and disinfection by-products. Coagulation process can be used to control natural organic matter (NOM) during water treatment. The effect of coagulation process appeared to depend on the pH of water rather than coagulant dosages. In this study, for water treatment in high pH season $H_2SO_4$ was applied for pH adjustment at full scale. Before and after pH adjustment by $H_2SO_4$ injection, water quality of drinking water was evaluate. In the result of investigation of total organic carbon (TOC) removal in high pH season, TOC was removed approximately 30~40%, which showed decrease in water treatment efficiency. Also, it is increased both particle numbers and residual Al concentration in the water. After $H_2SO_4$ injection for adjustment to pH<7.5 in settled water, treated water turbidity decreased in 0.047 NTU from 0.059 NTU, and particle numbers of filtered water decreased in 20/mL from 90/mL. On the other side, TOC removal efficiency increased in approximately 10% after adjustment of pH. In the result of decrease in pH in raw water through more coagulants and prechlorine without $H_2SO_4$ injection, trihalomethanes (THMs) concentration increased in $16{\mu}g/L$ from $8{\mu}g/L$.

Optimal Condition of TOC Removal Parameter for Sewage Effluent using Electrolysis Process (하수방류수 내 TOC 제거를 위한 전기분해공정의 최적 조건)

  • An, Sang-Woo;Jung, Hyuk-Sang;Lee, Hui-Kyung;Ko, Jun-Geol;Myoung, Dae-Won
    • Journal of the Korean GEO-environmental Society
    • /
    • v.18 no.4
    • /
    • pp.23-29
    • /
    • 2017
  • As the Enforcement Ordinance of Environmental Policy Act was revised in 2013, Total Organic Carbon (TOC) was added as an indicative parameter for organic matter in Water and Aquatic Ecosystem Environmental Criteria. Under these imminent circumstances, a regulatory standard is needed to achieve the proposed TOC limitation control water quality from the STP (Sewage Treatment Plant). In this study, a electrolysis utilizing the electrochemical reaction was investigated in lab-scale experiments for the treatment of TOC in sewage effluent. TOC reduction by a electrolysis was investigated response surface methodology using the Box-Begnken methods were applied to the experimental results. A central composite design was used to investigate the effects of the independent variables of electrode space ($x_1$), current density ($x_2$) and electrolyte concentration ($x_3$) on the dependent variables removal efficiency of TOC (y). The optimal conditions for electrolysis were determined: electrode space, current density and electrolyte concentration were 50 mm, $10.3mA/cm^2$ and 0.1M, respectively. Statistical results showed the order of significance of the independent variables to be electrode space > current density > electrolyte concentration.

Formation of Chloroform from Algal Cell Cultures by Chlorination (배양조류의 염소소독에 의한 클로로포름 생성특성 연구)

  • Kim, Hak-Chul;Choi, Il-Whan
    • Journal of environmental and Sanitary engineering
    • /
    • v.24 no.2
    • /
    • pp.40-48
    • /
    • 2009
  • Unusual bloom of toxic cyanobacteria in water bodies have drawn attention of environmentalists world over. Major bloom of Anabaena, Microcystis in water storage reservoir, rivers and lake leading to adverse health effects have been reported from Australia, England and many part of the world. These cyanobacterial cells can release intercellular matter like toxin in water and these intercellular matter can increase the concentration of organic matter. Cellysis can occur when algal cells meet the disinfectants like chlorine in water treatment plant and the resultant rising up of DOC(Dissolved Organic Carbon) or TOC(Total Organic Carbon) can increase the formation of disinfection by products. Disinfectants that kill microorganisms react with the organic or inorganic matter in raw water. In general disinfectants oxidize the matter in raw water and the resultant products can be harmful to human. There are always conflict about which is more important, disinfection or minimizing disinfection by products. The best treatment process for raw water is the process of the lowest disinfection by products and also the the lowest microorganism. In this study the cultured cells, Microcytis Aeruginosa(MA), Anabaena Flos-aquae(AF), Anabaena Cylindrica(AC), and the cells obtained in Daechung Dam(DC) whose dominant species was Anabaena Cylindrica were subjected to chlorination. Chlorination oxidizes inorganic and organic compounds and destruct live cells in raw water. Chloroform was analyzed for the cultured cells which were treated with $20mg/\ell$ dose of chlorine. In general chloroform is easily formed when dissolved organic matter react with chlorine. The cultured cells contributes the concentration of dissolved organic carbon and also that of total organic carbon which might be potent precusors of chloroform formed. The correlations of the concentration of chloroform, DOC and TOC were investigate in this study.

Behavior of Refractory Organic Matter in Leachate from Landfill Contaminated by Foot-and-mouth Disease (구제역 매몰지역 침출수에서 발생하는 난분해성 유기물질 거동)

  • Kang, Meea;An, Yaesol
    • The Journal of Engineering Geology
    • /
    • v.23 no.4
    • /
    • pp.427-434
    • /
    • 2013
  • The leachate from landfill (Andong city) contaminated by foot-and-mouth disease (FMD) contains 44%-50% hydrophilic organic matter, compared with 22%-27% in natural water bodies such as ground water, lake water, and river water. In such natural water, the organic matter content is reduced by the metabolism of microbes in the water. However, in the case of leachate-1 and -2, the concentrations of RTOC (refractory total organic carbon) and RDOC (refractory dissolved organic carbon) were higher than the initial TOC and DOC after burial. According to time elapsed after burial, the concentrations of RTOC and RDOC were decreased below the initial TOC and DOC. In the case of leachate-6 (386 days after burial), RDOC made up 91% of RTOC. This result shows that organic matter in the leachate was composed dominantly of RDOM, most of which was not removed by the metabolism of microbes. Hence, the presence and characteristics of RDOM provide a valuable indication of the effect of leachate on the quality of surface water and ground water. Such information is useful in understanding leachate environments.

Cleaning Validation Studies for Multi-Purpose Facility : Vial Filling Machine (다품목 공용 제약설비인 바이알 충전기에 대한 세척공정 밸리데이션)

  • Choi, Han-Gon;Yang, Ho-Joon;Kim, Young-Ran;Sung, Jun-Ho;Hwang, Ma-Ro;Kim, Jong-Oh;Yong, Chul-Soon
    • Journal of Pharmaceutical Investigation
    • /
    • v.39 no.4
    • /
    • pp.263-267
    • /
    • 2009
  • The purpose of this study is to evaluate the efficacy of stipulated cleaning process, and the prohibition of cross-contamination and microbiological contamination, which inadequate cleaning in multi-production could occur, through cleaning validation of multi-purpose facility used to produce five biopharmaceutical products as sterile injection. After production of five biopharmaceutical products such as hGH, rhGCSF, rhEPO, rhFSH and rhIFN using vial filling machine, the cleaning validation such as residual analysis of active ingredients or human serum albumin, measurement of total organic carbon (TOC), residual analysis of detergent and microbiological contamination were carried out. In the case of rhGH and rhGCSF clean validations, drug residues were not detected. Furthermore, in the case of rhEPO, rhFSH and rhIFN clean validations, human serum albumin residues were not detected. At TOC (total organic carbon) analysis, all clean validations gave the TOC of about average 137.93%, not more than 150% of acceptance criteria. At sodium analysis for the checking of residues of cleaning agent, sodium residues were not detected. In sterility test, they showed no microbiological contamination of bacteria and fungi. Thus, this cleaning validation was determined as successful in protection of cross-contamination and induction of safety in multi-purpose facility.

Effect of Adding Gypsum and Coal Fly Ash on Composting Process of Pig Manure (돈분 퇴비화 공정에서 석고 및 석탄회의 첨가효과)

  • 유현철;김정섭;곽명화;이히인;박승조
    • Resources Recycling
    • /
    • v.11 no.1
    • /
    • pp.32-36
    • /
    • 2002
  • This study was conducted to compost the mixture of Pig manure, gypsum and fly ash. Initial moisture contents of sample A (Pig manure : saw dust = 6 : 4) and C (Pig manure : saw dust : gypsum : coal fly ash= 6 : 2 : 1 : 1) in the reactor were 64 and 50%. Also temperature and pH of samples in the reactor was nearly the same. Total Organic Carbon (TOC) concentration of sample A and C were about 5500, 2900 mg/kg respectively. This sample was needed a lot of time to mature as viewing cation exchange capacity (CEC) after experiment was over. However added with gypsum and coal fly ash in Process of Pig manure composting Process was suggested that gypsum and coal fly ash have a roles of additive agent.

Development and Evaluation of Simple Regression Model and Multiple Regression Model for TOC Contentation Estimation in Stream Flow (하천수내 TOC 농도 추정을 위한 단순회귀모형과 다중회귀모형의 개발과 평가)

  • Jung, Jaewoon;Cho, Sohyun;Choi, Jinhee;Kim, Kapsoon;Jung, Soojung;Lim, Byungjin
    • Journal of Korean Society on Water Environment
    • /
    • v.29 no.5
    • /
    • pp.625-629
    • /
    • 2013
  • The objective of this study is to develop and evaluate simple and multiple regression models for Total Organic Carbon (TOC) concentration estimation in stream flow. For development (using water quality data in 2012) and evaluation (using water quality data in 2011) of regression models, we used water quality data from downstream of Yeongsan river basin during 2011 and 2012, and correlation analysis between TOC and water quality parameters was conducted. The concentrations of TOC were positively correlated with Chemical Oxygen Demand (COD), Biochemical Oxygen Demand (BOD), TN (Total Nitrogen), Water Temperature (WT) and Electric Conductivity (EC). From these results, simple and multiple regression models for TOC estimation were developed as follows : $TOC=0.5809{\times}BOD+3.1557$, $TOC=0.4365{\times}COD+1.3731$. As a result of the application evaluation of the developed regression models, the multiple regression model was found to estimate TOC better than simple regression models.