• 제목/요약/키워드: TN-C-S

검색결과 130건 처리시간 0.036초

감전사고 예방을 위한 영국의 보호도체 적용 방법 (The Application Method of a Protection Conductor for the Prevention of Electric Shock in England)

  • 정진수;정종욱;한운기;이준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.2216-2217
    • /
    • 2008
  • This paper write about earth system for the prevention electric shock and a protection of equipment in england. The IEC60364 and BSI(British Standards Institution) define earthing method(IT, TT, TN-C, TN-S, TN-C-S)-BSI is british standards and in case of england almost use the TN system. TN system can classify TN-S & TN-C-S(PME). The findings on survey in england are used the TN-S system and TN-C-S system about 70% and residue 30% are used TT system and IT system from the exiting state of things.

  • PDF

TN-C-S계통에서 PEN도체의 단선고장의 위험성 및 보호대책 (Hazards and Solutions of Loss of the PEN Conductor in TN-C-S System)

  • 이복희;이규선;안창환;김한수
    • 조명전기설비학회논문지
    • /
    • 제21권8호
    • /
    • pp.113-120
    • /
    • 2007
  • 본 논문은 TN-C-S계통에서 중성선 겸용 보호도체(PEN도체)의 단선고장시 감전의 위험성 및 보호대책에 관한 것으로 PEN도체의 단선고장시 노출도전성 부분의 접촉전압을 줄이기 위하여 전원측 접지저항과 수용가 추가접지 저항에 따른 PEN도체 단선시 노출도전성 부분에 나타나는 접촉전압을 실험적으로 조사하였다. 그 결과 TN-C-S 계통으로 공급되는 설비에 대하여 등전위본딩은 중요한 요건이다. 수용가의 인입구에 추가접지를 하는 것은 PEN 도체의 단선시 노출도전성 부분에 나타나는 접촉전압을 저감시키는 방법 중의 하나이다. 접촉전압을 안전전압 50[V]이하로 제한하는데 필요한 추가접지의 접지저항은 부하용량과 고장회로정수에 의하여 정해진다. 또한 부족전압계전기는 TN-C-S계통에서 PEN도체의 단선고장을 검출할 수 있는 적절한 해결방안이 될 수 있다.

IEC 60364 기반 접지계통 비교 분석 (The Comparison and Analysis about Earth System based on IEC60364)

  • 정진수;한운기;김오환;김재철
    • 조명전기설비학회논문지
    • /
    • 제24권1호
    • /
    • pp.56-62
    • /
    • 2010
  • 본 논문에서는 IEC 60364에서 제시하고 있는 접지계통(TT접지계통, TN-S 접지계통 및 TN-C)의 누전차단기 동작특성 및 보호도체의 임피던스변화에 따른 Loop Impedance 특성분석을 실시하였다. 분석결과 Loop Impedance의 경우 저항성분과 인턱턴스성분에 영향을 받는 것으로 나타났다. 접지계통별 전류 전압특성은 TN-S 접지계통 및 TN-C 접지계통의 경우 사고전류가 높고 접촉전압이 낮은 특성을 나타낸 반면 TT 접지계통의 경우 사고전류는 낮고 접촉전압이 높게 나타남을 확인하였다.

TN-C-S 접지계통에서 외부 루프 임피던스의 실측 및 기준값 설정에 관한 연구 (A Study on the Measurement and Determination of External Loop Impedance on TN-C-S System)

  • 이건호;정진수;문현욱;김선구
    • 전기학회논문지
    • /
    • 제62권8호
    • /
    • pp.1163-1168
    • /
    • 2013
  • The maximum allowable value of loop impedance($Z_s$) to secure the operation of overcurrent protective devices and the safety for indirect contact is a very important in TN-C-S system. The loop impedance is divided into inner loop impedance which consumer can adjust and external loop impedance($Z_e$) which only electric operator can adjust. Thus, an external loop impedance which limits to less than a certain value is a very important factor for human body protection against electric shock in TN-C-S system. The concept of loop impedance($Z_s$) is recently introduced to the domestic, the study about external loop impedance is yet insufficient. However, the study about the reference impedance as specified by the IEC 60725 standard to improve the quality and reliability of the power supply is being made. In this paper, reference value of external loop impedance($Z_e$) to meet domestic environment will be proposed by the nationwide measurement and statistical analysis.

TN-C-S계통에서 PEN도체 단선이 인체안전에 미치는 영향 (Personnel Safety Related to Disconnection of PEN Conductor in TN-C-S System)

  • 김정철;이규선;이복희
    • 조명전기설비학회논문지
    • /
    • 제26권5호
    • /
    • pp.58-64
    • /
    • 2012
  • In electric power supply systems, an earthing system determines the electric potential of the conductors related to that of the Earth's surface. The choice of earthing system has implications for the safety of the power supply systems. There are considerably different regulations for earthing (grounding) systems in each country. A protective earth(PE) conductor ensures that all exposed conductive surfaces are at the same electric potential as the earth surface. This paper deals with that when PEN conductor of TN-C-S system is disconnected, dangerous touch voltage causes personnel body to be harmed and human being's property to be damaged seriously. For this reason, this paper explains how serious problems can occur when the fault current flows. As a consequence, we can understand how we can design earthing system properly to ensure the personnel safety against earth faults. The result shows the way that TN-C-S system can be applied safely in Korea.

TN-C-S계통에서 PEN도체 단선이 인체안전에 미치는 영향 (Personnel safety related to a loss of PEN conductor in TN-C-S system)

  • 김정철;이복희;이규선;조정현
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2009년도 추계학술대회 논문집
    • /
    • pp.59-62
    • /
    • 2009
  • In electrical power supply systems, an earthing system determines the electrical potential of the conductors relative to that of the Earth's conductive surface. The choice of earthing system has implications for the safety of the power supply. Note that regulations for earthing (grounding) systems vary considerably among different countries. A protective earth(PE) connection ensures that all exposed conductive surfaces are at the same electrical potential as the surface of the Earth, This paper investigates that when PEN conductor of TN-C-S system is disconnected, dangerous touch voltage is caused at personnel body. According to this paper, we can understand that when TN-C-S system is applied in Korea, what we should set up to ensure the personnel safety from fault current.

  • PDF

급성관동맥증후군 관련 검사 (Tests for Acute Coronary Syndrome)

  • 김경동
    • Journal of Yeungnam Medical Science
    • /
    • 제18권1호
    • /
    • pp.13-29
    • /
    • 2001
  • The enzyme activities of creatine kinase (CK), its isoenzyme MB (CK-MB) and of lactate dehydrogenase isoenzyme 1 (LD-1) have been used for years in diagnosing patients with chest pain in order to differentiate patients with acute myocardial infarction (AMI) from non-AMI patients. These methods are easy to perform as automated analyses, but they are not specific for cardiac muscle damage. During the early 90's the situation changed. First, creatine kinase ME mass (CK-MB mass) replaced the measurement of CK-MB activity. Subsequently cardiac-specific proteins, troponin T (cTnT) and troponin I (cTnI) appeared and displacing LD-1 analysis. However, troponin concentrations in blood increase only from four to six hours after onset of chest pain. Therefore a rapid marker such as myoglobin, fatty acid binding protein or glycogen phosphorylase BB could be used in early diagnosis of AMI. On the other hand, CK-MB isoforms alone may also be useful in rapid diagnosis of cardiac muscle damage. Myoglobin, CK-MB mass, cTnT and cTnI are nowadays widely used in diagnosing patients with acute chest pain. Myoglobin is not cardiac-specific and therefore requires supplementation with some other analyses such as troponins to support the myoglobin value. Troponins are very highly cardiac-specific. Only the sera of some patients with severe renal failure, which requires hemodialysis, have elevated cTnT and/or cTnI without there being any evidence of cardiac damage. The latest studies have shown that elevated troponin levels in sera of hemodialysis patients point to an increased risk of future cardiac events in a similar manner to the elevated troponin values in sera of patients with unstable angina pectoris. In addition, the bedside tests for cTnT and cTnI alone- or together with myoglobin and CK-ME mass can be used instead of quantitative analyses in the diagnosis of patients with chest pain. These rapid tests are easy to perform and they do not require expensive instrumentation. For the diagnosis of patient with chest pain, routinely myoglobin and CK-ME mass measurements should be performed whenever they are requested (24 h/day) and cTnT or cTnI on admission to the hospital and then 4-6 and 12 hours later and maintained less than 10% in imprecision.

  • PDF

홍릉수목원수종의 개화기에 관하여 (On the Flowering Dates of the Woody Plant Species in the Hongneung Arboretum, Seoul)

  • Yang-Jai Yim;Muyon Cho
    • The Korean Journal of Ecology
    • /
    • 제1권1호
    • /
    • pp.17-23
    • /
    • 1977
  • Flowering dates of 389 plant species in the Hongneung Arboretum, Seoul, had been recorded from 1968 through 1975. The thermal analysis on the air temperature as the key factor determining the first flowering date, with climatological data obtained in the Arboretum, were undertaken by Nuttonson's Index (1948) and Lindsey & Newman's Index (1956). The results and conclusion in this study are as follow; Peak in the bell shape distribution curve of the species and first flowering dates, largely, was early May. Flower spans of most species were 10 to 20 days, neverthless, some species flower only a few days while others may stay flowering a hundred days even more. Increase-curves of summation temperature from early spring through late-summer showed almost the same mode in both Nuttonson;s Index (Tn) and Lindsey & Newman's Index (T1). These Indices manifested the exponential curve, increasing slowly at the beginning of spring chiefly but rapidly from the middle part of April. The equation of the linear relationahip between Tn and Tl as far as in thisstudy is as follow. Tl=230Tn It appears that the distribution of summation temperature, below Tn=400°C·day, affects the first flowering, even though it could be modified somehow by the distribution of precipitation, day length and others. Nuttonson's Index (Tn.f) and Lindsey & Newman's Index (Tl.f) upon the thermal amount first flowering dates have been respectively simulated as follow. Tn.f=θa + C Tl.f=230θa + 230C where θ is air temperature 10°C, a and C are a constant.

  • PDF

실리콘 기반 타원편광계식 바이오센서를 이용한 심근경색 생체표지자의 실시간 초고감도 진단 농도 측정 (Real-time Highly Sensitive Measurement of Myocardial Infarction Biomarkers Using Silicon-based Ellipsometric Biosensors)

  • 민윤기;조현모;조재흥
    • 한국광학회지
    • /
    • 제30권2호
    • /
    • pp.59-66
    • /
    • 2019
  • $2^{\circ}$ 기울어진 산화막 코팅 실리콘 기판의 바이오칩과 프리즘으로 제작한 바이오센서와 검광자 회전 타원편광계를 이용하여 심근경색 생체표지자인 미오글로빈과 cTnI의 진단 농도를 수백 초 내에 실시간 초고감도로 측정하는데 성공하였다. 러닝 버퍼로는 순수한 phosphate buffered saline (PBS) 또는 PBS에 10% 인간 혈청을 섞은 러닝 버퍼를 사용하였다. PBS 조건에서는 미오글로빈과 cTnI가 각각 1 ng/mL와 5 pg/mL로 측정되었으며, PBS에 인간 혈청을 10% 섞은 조건에서는 미오글로빈과 cTnI는 각각 1 ng/mL과 1 pg/mL로 측정되었다. 이러한 심근경색 생체표지자의 진단 농도는 현재 제시된 세계보건기구의 심근경색 진단 기준 농도보다 미오글로빈은 1/15배 낮고, cTnI는 1/80배 낮다.

Transposon Tn5 및 Reverse Field Electrophoresis를 이용한 Caulobuter crescentus의 유전자 분석 연구 (Genetic Analysis of Caulobuter crescentus by Using Transposon Tn5 and Reverse Field Electrophoresis)

  • 구본성;버트일리
    • 한국미생물·생명공학회지
    • /
    • 제17권3호
    • /
    • pp.183-187
    • /
    • 1989
  • 일반적으로 Mu phage를 가지고 있는 plasmid를 장내 세균에 삽입시키면 대부분의 Mu에 민감한 세균들은 zygotic induction이 일어나서 recipient cell 들이 살아남지 못하게 된다. 그러나 Mu 저항성 세균을 사용하면 cell이 죽지않고 recipient내에 삽입되는데 그 정확한 현상은 아직 밝혀지지 않았으나 Mu의 복제에 필요한 host의 기능이 결여된 것으로 추정되고 있다. 또한 reverse field electrophoresis를 사용하여 insertion mutant 나 deletion mutant들 의 염색체 및 거대 분자 DNA의 변이를 쉽게 비교 분석할 수가 있다. 본 실험에서는 Mu phage 저항성 C. crescentus를 사용하여 Tn5에 의한 영향 요구성 돌연변이주 출현률 및 운동성 돌연변이주 출현률을 조사한 결과 2%∼3% 수준으로 돌연변이가 일어났으며 이들 변이주들의 염색체를 Dra I 제한효소로 절단한 다음 reverse field electrophoresis로 분석한 결과 영양 요구성 돌연변이 균주들은 Tn5가 여러 위치에, 운동성에 돌연변이를 일으킨 균주들은 유사한 위치에 Tn5가 삽입된 것을 확인할 수 있었으나 hybridization 방법으로 확인한 것처럼 동시에 여러 위치를 확인할 수는 없었다. 그러나 이와 같은 문제들은 전기장의 교차시간 간격을 조절함으로 더 정확하게 확인할 수 있을 것으로 사료된다.

  • PDF