• 제목/요약/키워드: TN removal

검색결과 277건 처리시간 0.023초

자유수면형 인공습지에서 식물식재 유무가 처리효율에 미치는 영향 (Effects of Plant on Pollutant Removal Rate n Surface-flow Constructed Wetlands)

  • 함종화;김형중;김동환;홍대벽
    • 한국농공학회논문집
    • /
    • 제53권6호
    • /
    • pp.85-91
    • /
    • 2011
  • Three different types of wetlands (unplanted wetland, reed planted wetland, cattail planted wetland) were constructed at the mouth of Seokmoon reservoir with 910 $m^2$ each to examine the effects of wetland plant on pollutant removal rate in constructed wetland, and operated for 9 years (2002~2010). Water depth of the wetland was maintained at 0.3~0.5 m, flow rate was about 40~200 $m^3$/day, and retention time was managed at about 1~5 days. There was no difference in removal rate of SS, TN, and TP between reed wetland and cattail wetland. Removal rate of SS and TN in planted wetland with reed and cattail were higher than unplanted wetland, whereas removal rate of TP in unplanted wetland was higher then planted wetland. The monthly variation of removal rate in planted wetlands was high compared with unplanted wetland. From the long term monitoring results, SS and TN removal rates of period3 (2008~2010) were higher than period1 (2002~2004) in planted wetland, whereas TP removal rate was decreased as time goes on. Overall, pollutant removal rate in constructed wetland was more influenced by existence of plants than by plant species. Although constructed wetland is operated long term period, SS, TN, and TP removal rate (SS 90 %, TN 60 %, TP 40 %) can be maintained high values.

무산소-산소 공정에서 양론적 질소제거 연구 (Stoichiometric Study for Nitrogen Removal in Anoxic-oxic Process)

  • 이병대
    • 대한환경공학회지
    • /
    • 제27권11호
    • /
    • pp.1222-1227
    • /
    • 2005
  • 대표적인 질소제거 시스템인 무산소-산소공정을 대상으로 주어진 유입수 수질 조건에서 최대의 질소제거를 위한 최적의 슬러지 반송비를 질화/탈질 반응식을 이용하여 양론적으로 계산하였다. 양론적 계산에 고려된 수질 항목은 질화/탈질에 영향을 미치는 암모니아성 질소, 질산성질소, 알칼리도, COD, 용존산소로 설정하였다. 최대의 질소제거를 위한 최적의 슬러지 반송비를 앞의 5가지 유입수 항목으로 나타내었다. 양론적 계산에 의한 각 공정의 유출수와 최종 유출수 중의 TN농도가 실제 보고된 하 폐수 처리장의 TN농도와 잘 일치 하였다. 또한 양론적 계산에 의해 실제 처리장 최종 유출수 중의 TN농도를 ${\pm}5.0\;mg/L$ 내에서 예측 가능하였다.

B3공법을 이용한 분뇨처리시설 처리효율에 관한 연구 (Performance of Night Soil Treatment Plant using B3(Bio-Best-Bacillus) System)

  • 서윤하;이정봉;최성용;김득호;김진환;변정복
    • 상하수도학회지
    • /
    • 제24권4호
    • /
    • pp.407-412
    • /
    • 2010
  • The purpose of this study was to investigate removal efficiencies of contaminants in night soil treatment plant using the B3 system. The samples were collected from retaining tank and settlement tank in Yechon night soil plant. We experimented concentrations of BOD, COD, SS, TN and TP. Concentration data were processed using removal efficiencies by season and correlation analysis with pilot running parameters. Removal efficiencies of total organic carbon was over 96%, TN was 98% during summer, 80.9% during winter. In the case of TP, the highest removal efficiencies was 94.1% during fall and the lowest removal efficiencies was 82% during spring. Results of correlation analysis showed two positive correlation groups and one negative group. Positive correlations were among temperature, BOD and TN. The others were pH, BOD, COD, SS, TN and TP. Negative correlation were among MLSS, BOD, COD, SS, TN, TP.

하수의 N/P 비가 Botryococcus braunii 증식과 영양염류제거에 미치는 영향 (Effect of N/P Ratio on the Biomass Productivity and Nutrient Removal in the Wastewater using Botryococcus braunii)

  • 최희정;이승목
    • 대한환경공학회지
    • /
    • 제36권9호
    • /
    • pp.609-613
    • /
    • 2014
  • 본 연구는 미세조류 생장에 중요한 영향인자인 N/P ratio가 미세조류의 생장과 하수의 영양염류 제거에 미치는 영향을 알아보고자 하였다. 실험을 위하여 1-70까지의 다양한 N/P ratio를 준비하였으며, 미세조류는 Botryococcus braunii를 사용하였다. 실험결과 바이오매스 생산을 위하여 필요한 N/P ratio는 5-30이었다. TN의 제거율은 N/P ratio 1-30까지는 82%, 31-70까지는 73-78%의 제거율을 나타내어 TN 제거를 위한 N/P ratio는 1-30까지가 가장 좋았다. TP의 제거율 N/P ratio 1-20까지는 80% 이상의 높은 제거율을 나타내었지만, 20 이상부터는 급격하게 하락하여 50 이상에서는 22% 정도의 제거율로 변화가 없이 일정하였다. 따라서 바이오매스 생산량과 하수에서의 TN, TP의 제거를 위한 N/P ratio는 1-30이 가장 좋은 비율로 나타났다. TN, TP 제거율과 바이오매스의 생산량 상관관계는 TP 제거율과 바이오매스 생산량의 상관계수가($R^2$) 0.9126으로 상관관계가 매우 높았으나, TN 제거율과 바이오매스 생산량과의 상관관계는 찾을 수가 없었다. 이는 하수에서 TP의 함량이 TN의 함량보다 바이오매스 생산량에 밀접한 관계가 있음을 알 수 있다.

AnnAGNPS 모형을 이용한 수변구역의 비점오염물질 제거능 산정 (Estimation of Nonpoint Pollutant Removal Capacity in the Buffer Strip with AnnAGNPS Model)

  • 박윤희;김태근
    • 한국환경복원기술학회지
    • /
    • 제9권5호
    • /
    • pp.22-31
    • /
    • 2006
  • AnnAGNPS model would be applied to simulate the pollutant removal capacity with the buffer strip in the Deachung reservoir watershed. In 2002, 2,270 tons of TN and 221 tons of TP were discharged from the nonpoint source pollutants in this watershed. During the rainy season, from June to September, 66.4% of TN and 71.9% of TP resulted from nonpoint source loads. AnnAGNPS model was also used to simulate the nutrients removal capacity from the buffer strip under the condition that the present landuse would be changed to forest. As the result of simulation, the removal rates of nutrients from the buffer strip of Daecheong reservoir watershed are 406 tons of TN, 39 tons of TP, which means reduction rates are TN 17.9%, TP 17.8%, respectively.

하천수를 정화하는 갈대습지의 개수부에 의한 질소제거 비교 (Comparison of Nitrogen Removal in Reed Wetlands with and Without Open Water Purifying Effluent from a Treatment Pond)

  • 양홍모
    • 한국환경복원기술학회지
    • /
    • 제8권1호
    • /
    • pp.37-44
    • /
    • 2005
  • Nitrate($NO_3-N$) and total nitrogen(TN) removal by a reed wetland with open water(Wetland 1) was compared with that of a reed wetland without open water(Wetland 2) from March to October 2002. The two wetlands were 25mL by 6mW. An open water area, 3mL by 6mW was designed at the middle of Wetland 1. Reeds(Phragmites australis) were transplanted into the wetlands in June 2000. Water of Sinyang Stream flowing into the Kohung Estuarine Lake located in the southern part of Korea was pumped into a primary treatment pond, whose effluent was discharged into the secondary pond. Effluent from the secondary pond was funneled into the wetlands. Inflow into the wetlands averaged about 20.0$m^3$/day and their hydraulic retention time was approximately 1.5 days. Average $NO_3-N$ removal by Wetland 1 was 117.61mg/$m^2{\cdot}day$ and that by Wetland 2 was 106.39mg/$m^2{\cdot}day$. $NO_3-N$ removal efficiency of Wetland 1 and 2 was 37% and 34%, respectively. TN removal by Wetlands 1 and 2 averaged 226.80 and 214.54mg/$m^2{\cdot}day$, respectively. TN abatement efficiency of Wetland 1 was 43% and that of Wetland 2 was 40%. $NO_3-N$ removal efficiency of Wetland 1 was significantly higher(p=0.038) than Wetland 2. TN removal efficiency of Wetland 1 was also significantly higher(p=0.044) than Wetland 2. The wetland with open water was more efficient for removal of $NO_3-N$ and TN than one without.

노랑꽃창포 자유수면습지의 계절에 따른 질소제거 비교 (Comparison of Seasonal Nitrogen Removal by Free-Water Surface Wetlands Planted with Iris pseudacorus L.)

  • 양홍모
    • 한국환경복원기술학회지
    • /
    • 제14권1호
    • /
    • pp.121-132
    • /
    • 2011
  • Removal rates of $NO_3$-N and TN in the free-water surface wetland system during winter; December, January, February and March, spring and fall; April, May, October and November, and summer; Jun, July, August and September were investigated. The system was established on floodplain in the downstream reach of the Gwangju Stream in 2008. It measures 50 meters in length and 5.5 meters in width. Iris pseudacorus L. grown in pots for about two years were planted in the system. The water stream was funneled in by gravity and its effluent was discharged back in. Volumes and water quality of inflow and outflow were analyzed from December 2008 to November 2010. The inflow was averaged approximately 350 $m^3/day$ and hydraulic residence time was about 3 hours. Average influent and effluent $NO_3$-N concentration was 3.75 and 3.35 mg/L, respectively and $NO_3$-N retention was amounted to 10.6%. Influent and effluent TN concentration were averaged 4.93 and 4.30 mg/L, respectively and TN abatement reached to 12.9%. One-way ANOVA statistics claimed that the average removal rates of $NO_3$-N and TN during winter, spring and fall, and summer were not always the same (p<0.001). The t-Tests of three pairs among $NO_3$-N removal rates of winter, spring and fall, and summer illustrated that the removal rates of winter ($5.04{\pm}1.94$), spring and fall ($10.53{\pm}2.24$), and summer ($18.61{\pm}2.26$) were significantly different each others (p<0.001). Among TN removal rates, the three pairs of t-Tests of three seasons showed that the removal rates of winter ($5.21{\pm}2.51$), spring and fall ($11.71{\pm}3.12$), and summer ($21.53{\pm}4.86$) were significantly different from each others (p<0.001).

Estimation of the Pollutant Removal Efficiency in a Buffer Strip Using a SWAT Model

  • Lee, Eun-Jeong;Choi, Kyoung-Sik;Kim, Tae-Geun
    • Environmental Engineering Research
    • /
    • 제16권2호
    • /
    • pp.61-67
    • /
    • 2011
  • The water quality from nonpoint source run off results from different land use types has been studied. The construction of a buffer strip is one method of nonpoint source pollutant control. The Soil and Water Assessment Tool (SWAT) model has been applied to estimate the pollutant removal through the buffer strip. When the non-business land has been changed into grass to form a buffer-strip, the change of land use effects the results of the model according to measures of the water quality. The data from a water level station within the watershed in the years 2006 and 2007 was used for calibration and validation of the model. Under the rainfall conditions in 2007, the removal rates of SS, BOD, TN, TP were 11.5%, 9.5%, 1.2%, and 4.5%, respectively. During the rainy days, the removal rates at the buffer strip were 92.3% of SS, 91.2% of BOD, 82.4% of TN, and 83.5% of TP. The pollutants from nonpoint sources were effectively removed by over 80% as they passed through the buffer strips. Rainfall resulted in soil erosion, which led to an increase in the SS concentration, therefore, the construction of buffer strips protected the streams from SS inflows. Since TN concentrations are affected by the inflows of ground water and the N concentration of the rainfall, the removal rate of TN was relatively lower than for the other pollutants.

Estimation of Optimal Operation Conditions in Step Feed Processes Based on Stoichiometric Nitrogen Removal Reactions

  • Lee, Byung-Dae
    • 한국응용과학기술학회지
    • /
    • 제28권1호
    • /
    • pp.6-9
    • /
    • 2011
  • Step feed process was analyzed stoichiometrically for the optimal operation conditions in this study. In case of optimal operation conditions, minimum R (sludge recycling) value, r (internal recycling ratio) value, and n (influent allocation ratio) value for the step feed process to acquire the maximum TN removal efficiency were identified by theoretical analysis. Maximum TN removal efficiency, based on stoichiometric reaction, can be obtained by controlling n value for the step feed process.

MARPOL 73/78의 기준에 따른 선박오수 처리 장치(SBR 및 MBR 복합공정)의 사용 가능성 평가 : 영양염류 위주 (T-N 및 T-P) (Feasibility Study of a Shipboard Sewage Treatment Plant (Sequencing Batch Reactor and Membrane Bioreactor) in Accordance with MARPOL 73/78, Focusing Mostly on Nutrients (T-N and T-P))

  • 정진희;윤영내;최영익
    • 한국환경과학회지
    • /
    • 제25권9호
    • /
    • pp.1233-1239
    • /
    • 2016
  • This study aimed to evaluate changes in the TN and TP removal efficiencies, depending on whether or not a settling process is applied, in a sequencing batch reactor (SBR) process with a membrane bioreactor (MBR). Nutrient removal was considered in terms of developing an advanced water treatment system for ships in accordance with water quality standards set forth by 227(64). For these purposes, the TN and TP concentrations in the inflow and outflow water were measured to calculate the TN and TP removal efficiencies, depending on whether or not a settling process was used. Water discharged from a bathroom, which was constructed for the experiment, was used as the raw water. The experiment that included a settling process was conducted twice, and the operating conditions were: aeration for 90 min, settling for 30 min, agitation for 15 min, and settling for 15 min for one experiment; and aeration for 150 min, settling for 45 min, agitation for 15 min, and settling for 15 min in the other. Operating conditions for the experiment that did not include a settling process were: aeration for 180 min and agitation for 60 min. The concentration of the mixed liquor suspended solids (MLSS) in the reactor was 3,500 mg/L, while the aeration rate was 121 L/min and the water production rate was 1.5 L/min. For the two experiments where a settling process was applied, the average TN removal efficiencies were 44.39% and 41.05%, and the average TP removal efficiencies were 47.85% and 46.04%. For the experiment in which a settling process was not applied, the average TN removal efficiency was 65.51%, and the average TP removal efficiency was 52.51%. Although the final nutrient levels did not satisfy the water quality standards of MEPC 227(64), the TN and TP removal efficiencies were higher when a settling process was not applied.