• Title/Summary/Keyword: TM9

Search Result 637, Processing Time 0.026 seconds

Improvement of Electrical/optical Characteristics Using Mg-doped GaN Spacers and Quantum Barriers for Nonpolar GaN light-emitting Diodes (마그네슘이 도핑된 GaN 공간층과 양자장벽층을 이용한 무분극 GaN 발광다이오드의 전기적/광학적 특성 향상)

  • Kim, Dong-Ho;Son, Sung-Hun;Kim, Tae-Geun
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.48 no.7
    • /
    • pp.10-16
    • /
    • 2011
  • We report on the simulation results of electrical/optical characteristics for nonpolar GaN LED having Mg-doped GaN spacer and quantum barrier, in comparison with those of the typical nonpolar GaN LED. In order to reduce the band-gap energy distortion and conduction-band discontinuity in InGaN/GaN multiple quantum wells(MQWs) of nonpolar GaN LED, and thereby to increase their current-voltage, light output power and emission peak intensity, we applied 6 nm-thick p-type($1{\times}10^{18}\;cm^{-3}$) GaN spacer and GaN QB schemes to the typical nonpolar GaN LED epitaxial structure. As a result, we found that the radiative recombination rate was increased by 23% in MQWs at 20 mA current injection. Also, the forward voltage($V_f$) and the light output power($P_{out}$) were improved by 3.7% and 7%, respectively, for the proposed nonpolar LED epitaxial structure, compared with those of the typical nonpolar GaN LED.

Comparison of Fecal Microbiota of Mongolian and Thoroughbred Horses by High-throughput Sequencing of the V4 Region of the 16S rRNA Gene

  • Zhao, Yiping;Li, Bei;Bai, Dongyi;Huang, Jinlong;Shiraigo, Wunierfu;Yang, Lihua;Zhao, Qinan;Ren, Xiujuan;Wu, Jing;Bao, Wuyundalai;Dugarjaviin, Manglai
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.29 no.9
    • /
    • pp.1345-1352
    • /
    • 2016
  • The hindgut of horses is an anaerobic fermentative chamber for a complex and dynamic microbial population, which plays a critical role in health and energy requirements. Research on the gut microbiota of Mongolian horses has not been reported until now as far as we know. Mongolian horse is a major local breed in China. We performed high-throughput sequencing of the 16S rRNA genes V4 hypervariable regions from gut fecal material to characterize the gut microbiota of Mongolian horses and compare them to the microbiota in Thoroughbred horses. Fourteen Mongolian and 19 Thoroughbred horses were used in the study. A total of 593,678 sequence reads were obtained from 33 samples analyzed, which were found to belong to 16 phyla and 75 genera. The bacterial community compositions were similar for the two breeds. Firmicutes (56% in Mongolian horses and 53% in Thoroughbred horses) and Bacteroidetes (33% and 32% respectively) were the most abundant and predominant phyla followed by Spirochaete, Verrucomicrobia, Proteobacteria, and Fibrobacteres. Of these 16 phyla, five (Synergistetes, Planctomycetes, Proteobacteria, TM7, and Chloroflexi) were significantly different (p<0.05) between the two breeds. At the genus level, Treponema was the most abundant genus (43% in Mongolian horses vs 29% in Thoroughbred horses), followed by Ruminococcus, Roseburia, Pseudobutyrivibrio, and Anaeroplasma, which were detected in higher distribution proportion in Mongolian horses than in Thoroughbred horses. In contrast, Oscillibacter, Fibrobacter, Methanocorpusculum, and Succinivibrio levels were lower in Mongolian horses. Among 75 genera, 30 genera were significantly different (p<0.05) between the two breeds. We found that the environment was one of very important factors that influenced horse gut microbiota. These findings provide novel information about the gut microbiota of Mongolian horses and a foundation for future investigations of gut bacterial factors that may influence the development and progression of gastrointestinal disease in horses.

Comparison of slim bristled and V-shaped orthodontic toothbrushes in patients with fixed orthodontic appliances (고정식 교정장치 장착환자에서 슬림모 칫솔과 V형 교정칫솔 간의 구강위생관리 효과 비교)

  • Choi, Jin-Hugh
    • The korean journal of orthodontics
    • /
    • v.39 no.6
    • /
    • pp.383-392
    • /
    • 2009
  • Objective: The purpose of this study was to evaluate the efficacy of a slim bristled toothbrush compared with a V-shaped orthodontic toothbrush in patients with fixed orthodontic appliances. Methods: Thirty four orthodontic patients receiving edgewise treatment were randomly assigned to two groups, a slim bristled toothbrush (Nano silver slim care) and a V-shaped toothbrush (Oral-B). Plaque index, gingival index and bleeding index were recorded at the beginning of the study (baseline), 2 weeks, 4 weeks and 6 weeks after new toothbrushes were supplied and the results were analyzed statistically. Results: No statistically significant differences were found for plaque index, gingival index and bleeding index between toothbrush groups during the 6 weeks. Plaque and gingival indices were decreased at 2 weeks and 4 weeks but increased at 6 weeks in both toothbrush groups. Bleeding index in the V-shaped toothbrush group showed the lowest value at 2 weeks then increased at 4 weeks and 6 weeks but in the slim bristled toothbrush group decreased from 2 weeks through 6 weeks to under baseline levels. Patients in their twenties had significantly lower values than teenagers in the slim bristled toothbrush group (p < 0.013). Conclusions: The results would suggest that both of the toothbrushes are equally effective but the use of a slim bristled toothbrush may be of benefit in promoting gingival health for fixed orthodontic appliance patients in their twenties and over.

Bioequivalence of Two Nilvadipine Tablet (닐바디핀 정제에 대한 생물학적 동등성 평가)

  • 김종국;이사원;최한곤;고종호;이미경;김인숙
    • Biomolecules & Therapeutics
    • /
    • v.6 no.3
    • /
    • pp.289-295
    • /
    • 1998
  • The bioequivalence of two nilvadipine products was evaluated in 16 normal male volunteers (age 22-32 yr, body weight 57-80 kg) following sidle oral dose. Test product was Overca $l_{R}$ tablet (Choong-Wae Pharm. Corp., Korea) and reference product was Nivadi $l_{R}$ tablet (Hyundai Pharm. Corp., Korea). Both products contain 4 mg of nilvadipine. One tablet of the test or the reference product was administered to the volunteers, respectively, by randomized two period cross-over study (2$\times$2 Latin square method). The determination of nilvadipine was accomplished using a validated capillary column GC with electron-capture detection. As a result of the assay validation, the quantiflcation of nilvadipine in human plasma by this technique was possible down to 0.5 ng/ml using 1 ml of plasma. Absolute overall recovery from five replicate analyses of nilvadipine-spiked sample were 88.4$\pm$ 10.24% (mean$\pm$ 5.D.) for human plasma of 10 ng/ml. The coefficients of variation (C.V.) were less than 20% and the actual concentration of nilvadipine measured by GC ranged from 80 to 99% in all plasma. Average drug concentrations at each sampling time and pharmacokinetic parameters calculated were not significantly different between two products (p>0.05); the area under the curve from time zero to 8 hr (AUCo-$_{8 hr}$) (22.8$\pm$5.90 vs 22.2$\pm$6.10 ng . hr/ml), maximum plasma concentration ( $C_{max}$) (10.0$\pm$2.85 vs 9.3$\pm$3.28 ng/ml) and time to reach maximum plasma concentration ( $T_{max}$) (1.2$\pm$0.31 vs 1.3 $\pm$0.47 hr). The differences of mean AU $Co_{8hr}$ $C_{max}$, and $T_{max}$ between the two products (2.25, 7.65, and 10.30%, respectively) were less than 20%. The power (1-$\beta$) and treaeent difference (7) for AU $Co_{8hr}$, and $C_{max}$ were more than 0.8 and less than 0.2, respectively. Although the power for Tmax was under 0.8, Tm\ulcorner of the two products was not significantly different from each other (p>0. 05). These results suggest that the bioavailability of Overeat tablet is not significantly different from that of Nivadil tablet. Therefore, two products are bioequivalent based on the current results.sults.lts.lts.lts.

  • PDF

Evaluation of Conventional Culture Methods and Validation of Immunoassays for Rapid Detection of Listeria monocytogenes in Dairy and Processed Foods (유제품 및 가공식품에서 Listeria monocytogenes 검출을 위한 배지법과 신속 검사키트의 유효성 검증)

  • Han, So-Ri;Hyeon, Ji-Yeon;Kim, Hee-Yun;Park, Jong-Seok;Heo, Seok;Shin, Ho-Chul;Seo, Kun-Ho
    • Food Science of Animal Resources
    • /
    • v.28 no.5
    • /
    • pp.616-622
    • /
    • 2008
  • Listeria monocytogenes is a foodborne pathogen inducing listeriosis in human. We compared two different culture methods for detection of L. monocytogenes and validated two commercial kits, $VIDAS^{(R)}$ and $REVEAL^{(R)}$ for Listeria. L. monocytogenes was inoculated into various food samples to generate partial positive samples. The inoculated samples were enriched in half-Fraser broth for 48 hr at $30^{\circ}C$. The enriched samples were streaked onto Oxford agar at 24 and 48 hr postincubation followed by biochemical confirmation and concurrently analyzed by using the two commercial kits for comparison. When the enrichment period was extended from 24 to 48 hr, the numbers of positive samples were dramatically increased from 6 to 52 out of 80 samples tested using the culture method. With the commercial kits, the numbers of positive samples were also significantly increased from 10 to 18 and 1 to 18, respectively, when the enrichment period was extended from 48 to 72 hr. There was no statistical difference between the 24 hr culture method and $VIDAS^{(R)}$ or $Reveal^{(R)}$ with 48 hr enrichment. In conclusion, the 24 hr for the culture method was insufficient to detect L. monocytogenes in various foods. The commercial kits could be adequate means for presumptive screening of L. monocytogenes in food.

Three-dimensional image analysis of the skull using variable CT scanning protocols-effect of slice thickness on measurement in the three-dimensional CT images (두개골의 3차원 영상 분석을 위한 전산화단층촬영 방법의 비교-상층 두께가 3차원 영상의 계측에 미치는 영향)

  • Jeong Ho-Gul;Kim Kee-Deog;Park Hyok;Kim Dong-Ook;Jeong Haijo;Kim Hee-Joung;Yoo Sun Koo;Kim Yong Oock;Park Chang-Seo
    • Imaging Science in Dentistry
    • /
    • v.34 no.3
    • /
    • pp.151-157
    • /
    • 2004
  • Purpose : To evaluate the quantitative accuracy of three-dimensional (3D) images by means of comparing distance measurements on the 3D images with direct measurements of dry human skull according to slice thickness and scanning modes. Materials and Mathods : An observer directly measured the distance of 21 line items between 12 orthodontic landmarks on the skull surface using a digital vernier caliper and each was repeated five times. The dry human skull was scanned with a Helical CT with various slice thickness (3, 5, 7 mm) and acquisition modes (Conventional and Helical). The same observer measured corresponding distance of the same items on reconstructed 3D images with the internal program of V-works 4.0/sup TM/(Cybermed Inc., Seoul, Korea). The quantitative accuracy of distance measurements were statistically evaluated with Wilcoxons' two-sample test. Results: 11 line items in Conventional 3 mm, 8 in Helical 3mm, 11 in Conventional 5mm, 10 in Helical 5mm, 5 in Conventional 7mm and 9 in Helical 7mm showed no statistically significant difference. Average difference between direct measurements and measurements on 3D CT images was within 2mm in 19 line items of Conventional 3mm, 20 of Helical 3mm, 15 of Conventional 5mm, 18 of Helical 5mm, II of Conventional 7mm and 16 of Helical 7mm. Conclusion: Considering image quality and patient's exposure time, scanning protocol of Helical 5mm is recommended for 3D image analysis of the skull in CT.

  • PDF

Comparison of cone beam computed tomography and conventional panoramic radiography in assessing the topographic relationship between the mandibular canal and impacted third molars (하악 제3대구치와 하악관과의 위치관계에 대한 파노라마 방사선사진과 cone beam형 전산화단층촬영상의 비교)

  • Choi, Hyung-Soo;Kim, Gyu-Tae;Choi, Yong-Suk;Hwang, Eui-Hwan
    • Imaging Science in Dentistry
    • /
    • v.38 no.3
    • /
    • pp.169-176
    • /
    • 2008
  • Purpose : To assess the diagnostic accuracy and value in an imaging technique field through the comparison of cone beam computed tomography and conventional panoramic radiography in assessing the topographic relationship between the mandibular canal and impacted third molars. Materials and Methods : Participants consisted of 100 patients offered the images through cone beam computed tomography and panoramic radiography. PSR-$9000^{TM}$ Dental CT system (Asahi Roentgen Ind. Co., Ltd, Japan) was used as the unit of cone beam computed tomography. CE-II (Asahi Roentgen Ind. Co., Ltd, Japan) and Pro Max (Planmeca Oy, Finland) were used as the unit of panoramic radiography. The images obtained through panoramic radiography were classified into 3 types according to the distance between mandibular canal and root of mandibular third molar. And they were classified into 4 types according to the proximity of radiographic feature. The images obtained through cone beam computed tomography based on the classification above were classified into 4 types according to the location between the mandibular canal and the root and were analyzed. And they were classified into buccal, inferior, lingual, and between roots, according to the location between mandibular canal and root. The data were statistically analyzed and estimated by $X^2$-test. Results : 1. There was no statistical significance according to 3 types (type I, type II, type III) through CBCT. 2. The results of 4 types (type A, type B, type C, type D) through CBCT were as high prevalence of CBCT 1 in type A, CBCT 2 in type B, CBCT 3 in type C, and CBCT1 in type D and those of which showed statistical significance (P value=0.03). 3. The results according to location between mandibular canal and root through CBCT recorded each 49, 25, 17, 9 as buccal, inferior, lingual, between roots. Conclusion : When estimating the mandibular canal and the roots through the panoramic radiography, it could be difficult to drive the views of which this estimation was considerable. Thus it is required to have an accurate diagnostic approaching through CBCT that could estimate the location between mandibular canal and roots.

  • PDF

Matrix Metalloproteinase-1 and Tissue Inhibitor of Metalloproteinase-1 levels in Exudative Pleural Effusions (삼출성 흉수에서 기질 금속단백분해효소-1과 금속단백분해효소의 조직억제제-1)

  • Cho, Jae Hwa;Nam, Jeong Hyeon;Lee, Kyum Ho;Yoon, Byeong Kab;Ryu, Jeong Sun;Kwak, Sung Min;Lee, Hong Lyeol
    • Tuberculosis and Respiratory Diseases
    • /
    • v.59 no.5
    • /
    • pp.517-521
    • /
    • 2005
  • Background : The balances of the proteinases and antiproteinases system have been implicated in the pathogenesis of various exudative pleural effusions. The aim of this study was to examine the matrix metalloproteinase-1 (MMP-1) and tissue inhibitor of metalloproteinase-1 (TIMP-1) levels in exudative pleural effusions. Methods : The study included 33 tuberculous effusions, 17 malignant, and 5 transudates. The pleural levels of MMP-1 and TIMP-1 were determined using a commercially available ELISA assay. Results : The group of tuberculous effusions showed higher pleural MMP-1 levels than the malignant and transudates. The pleural TIMP-1 levels of the tuberculous and malignant effusions were higher than the transudates. Conclusion : Elevated pleural MMP-1 and TIMP-1 levels were found in tuberculous effusions.

Analysis of Correlation Coefficient Between Movements of Thoracoabdominal Tumors and External Respiration Using Image Guided Radiotherapy(IGRT) (영상유도 방사선치료장치(IGRT)를 이용한 흉·복부 종양의 움직임과 외부호흡과의 상관관계 분석)

  • Kim, Gha-Jung;Hong, Ju-Youn;Han, Sang-Hyun
    • The Journal of the Korea Contents Association
    • /
    • v.14 no.9
    • /
    • pp.362-370
    • /
    • 2014
  • This study measured and analyzed the correlation coefficient between movements of thoracoabdominal tumors and external respiration in a free-breathing state, using cyberknife image guided radiotherapy(IGRT). This study subjects included a total of 30 patients with lung tumors(n=10), liver tumors(n=10) and pancreatic tumor(n=10) who underwent radiotherapy, and the movements of tumors were analyzed using converted log data of the tumor motion tracking system(MTS). In a free-breathing state, In relation to Peason's correlation coefficient between external respiration and lung tumors in the entire treatment process, the correlation coefficient was 0.646(p<0.05) in the cranio-caudal direction, 0.365(p<0.088) in the left and right direction and 0.196(p<0.115) in the antero-posterior direction. The correlation coefficient of liver tumors was 0.841(p<0.000) in the cranio-caudal direction, 0.346 (p<0.179) in the left and right direction and 0.691(p<0.001) in the antero-posterior direction. The correlation coefficient of Pancreatic tumors was 0.683(p<0.000) in the cranio-caudal direction, 0.397(p<0.006) in the left and right direction and 0.268(p<0.127) in the antero-posterior direction. In conclusion, the measurement findings of thoracoabdominal tumor movement using IGRT would be helpful in determining an accurate target volume. Moreover, the analysis of correlation between external respiration and movements of internal tumors would provide important information to correct movements of tumors for diverse radiotherapy techniques.

Understanding the Viscoelastic Properties and Surface Characterization of woodflour-Polypropylene Composites (목분-폴리프로필렌 복합재의 점탄성적 성질과 표면특성)

  • Son, Jungil;Gardner, Douglas J.
    • Journal of Adhesion and Interface
    • /
    • v.3 no.4
    • /
    • pp.1-9
    • /
    • 2002
  • The main goal of this study was to analyze the effect of process additives, i.e. maleated polypropylene (MAPP), and nucleating agent on the viscoelastic properties of different types of extruded polypropylene-wood plastic composites manufactured from either PP homopolymer, high crystallinity PP or PP impact copolymer using dynamic mechanical thermal analysis. And also, the esterification reaction between wood flour and maleated polypropylene, and its role in determining the mechanical properties of wood flour-polypropylene composites was investigated. The wood plastic composites were manufactured using 60% pine wood flour and 40% polypropylene on a Davis-Standard $Woodtruder^{TM}$. Dynamic mechanical thermal properties, polymer damping peaks(than ${\delta}$), storage modulus (E') and loss modulus (E") were measured using a dynamic mechanical thermal analyzer. XPS (X-ray Photoelectron Spectroscopy), also known as ESCA (Electron Spectroscopy for Chemical Analysis) study of wood flour treated with MAPP was performed to obtain information on the chemical nature of wood fiber before and after treatment. To analyze the effect of frequency on the dynamic mechanical properties of the various composites, DMA tests were performed over a temperature range of -20 to $100^{\circ}C$, at four different frequencies (1, 5, 10 and 25 Hz), and at a heating rate of $5^{\circ}C/min$. From these results, the activation energy of the various composite was measured using an Arrhenius relationship to investigate the effect of maleated PP and nucleating agent on the measurement of the interphase between the wood and plastic of the extruded polypropylene wood plastic composites.

  • PDF