• 제목/요약/키워드: TM4

검색결과 1,649건 처리시간 0.029초

악성 종양 환자에 대한 DR-$70^{TM}$ 면역 분석법의 의의: Validation Study (Meaning of the DR-$70^{TM}$ Immunoassay for Patients with the Malignant Tumor)

  • 이기호;조동희;김상만;이득주;김광민
    • IMMUNE NETWORK
    • /
    • 제6권1호
    • /
    • pp.43-51
    • /
    • 2006
  • Background: The DR-$70^{TM}$ immunoassay is a newly developed cancer diagnostic test which quantifies the serum fibrin degradation products (FDP), produced during fibrinolysis, by antibody reaction. The purpose of this study was to evaluate the potential of DR-$70^{TM}$ Immunoassay in screening malignant tumor. Methods: Sample subjects were 4,169 adults, both male and female, who visited the health promotion center of a general hospital from March 2004 to April 2005 and underwent the DR-$70^{TM}$ immunoassay test and other tests for cancer diagnosis. The patient group was defined as 42 adults out of the sample subjects who were newly diagnosed with cancer during the same time period when the DR-$70^{TM}$ immunoassay test was performed. Final confirmation of a malignant tumor was made by pathological analysis. Results: The mean DR-$70^{TM}$ level was $0.83{\pm}0.65{\mu}g/ml$ (range: 0.00 (0.0001)${\sim}7.42{\mu}g/ml)$ in the control group (n=4,127) as opposed to $2.70{\pm}2.33{\mu}g/ml$ (range: $0.12{\sim}9.30{\mu}g/ml)$ in the cancer group (n=42), and statistical significance was established (p<0.0001, Student t-test). When categorized by the type of malignant tumor, all cancer patients with the exception of the subgroups of colon and rectal cancer showed significantly higher mean DR-$70^{TM}$ levels compared with the control group (p<0.0001, Kruscal-Wallis test). The receiver operating characteristic (ROC) curve analysis revealed ${\geq}1.091{\mu}g/ml$ as the best cut-off value. Using this cut-off value, the DR-$70^{TM}$ immunoassay produced a sensitivity of 71.4%, a specificity of 70.1%, a positive predictability of 69.4%, and a negative predictability of 69.2% (1). Conclusion: A significant increase in the mean DR-$70^{TM}$ value was observed in the cancer group (thyroidal, gastric, breast, hepatic and ovarian) com pared with the control group. In particular, the specificity and sensitivity of the DR-$70^{TM}$ immunoassay was relatively high in the subgroups of breast, gastric, and thyroidal cancer patients. There is need for further studies on a large number of malignant tumor patients to see how the DR-$70^{TM}$ level might be changed according to the differentiation grade and postoperative prognosis of the malignant tumor.

이중나사산 임플란트의 안정성에 대한 평가 - 오스텔 멘토를 이용한 초기 안정성 ; PART I (Evaluation of Stability of Double Threaded Implant-Emphasis on Initial Stability Using Osstell MentorTM; Part I)

  • 김시엽;김병국;허진호;이주연;정창모;김용덕
    • 구강회복응용과학지
    • /
    • 제23권4호
    • /
    • pp.327-336
    • /
    • 2007
  • Fixture의 안정도를 평가하는 장비인 Osstell Mentor와 기존 Osstell과의 비교 시험 및 측정환경에 따른 노이즈 발생 시험 결과를 통해 다음과 같은 결과를 얻었다. 1. US II Fixture와 SS II Fixture의 ISQ 값을 측정한 1차 검증에서는 Osstell과 Osstell Mentor의 ISQ 값 경향의 차이가 크게 나타나지 않음을 확인하였다. 2. SS II Fixture를 얕게 매식한 것과 정상적인 매식한 것의 ISQ 값 비교를 한 2차 검증에서는, Osstell과 Osstell Mentor 모두 매식 깊이에 따른 동일한 경향의 결과를 보였다. 3. 3차 검증에서는 골질별로 Osstell과 Osstell Mentor의 ISQ 값이 일정한 경향을 보이는 것을 확인하였고, 특히 Osstell Mentor 장비는 Osstell 장비보다 사용함에 있어서 편리성이 뛰어나다고 판단된다. 또한 ISQ 값을 100% 신뢰하기는 어렵지만 Osstell Mentor를 임상 및 실험에 적용하는데 있어서는 문제가 없을 것으로 판단된다. 4. 측정환경에 따라 전자파를 발생시키는 환경이 존재하면 노이즈가 발생할 수 있으나, 실제 측정결과 휴대폰이 작동 중인 환경을 제외하고는 노이즈가 발생하지 않았다. 실제 치과 내에서의 사용에서도 노이즈는 발생하지 않음을 확인하였다. 5. 비교적 안전하게 장치를 장착 및 탈착 할 수 있어 측정과정에 의해 발생되는 임플란트와 주위골에 대한 잠재적 위험도가 낮고 측정위치에 따른 오차가 적어 임상적으로 불리한 상황과 다양한 환경에서의 임플란트 안정성 측정이 가능해 임상적 활용도가 높다고 판단된다.

ENG 영차 공진을 이용하여 대역폭이 개선되고 지향성 방사 패턴을 갖는 하이브리드 안테나 (Broadband Hybrid Antenna with Directional Radiation Pattern Utilizing Epsilon Negative Zeroth-Order Resonance)

  • 김인호;이정혜
    • 한국전자파학회논문지
    • /
    • 제21권8호
    • /
    • pp.886-892
    • /
    • 2010
  • 본 논문에서는 epsilon negative(ENG) 영차 공진과 $TM_{010}$-모드를 결합하여 넓은 대역폭을 갖고, 지향성 방사 패턴을 갖는 하이브리드 안테나를 제안한다. ENG 영차 공진을 얻기 위해 버섯 구조를 이용하였고, $TM_{010}$ 모드를 얻기 위해 패치 안테나를 이용하였다. 이 두 개의 안테나 사이에 갭을 주어 하나의 동축 선로 급전 구조로 두 개의 안테나를 결합하였다. ENG ZOR 주파수는 4 GHz, $TM_{010}$의 주파수는 3.9 GHz로 설계하였다. 두 주파수가 근접해 있기 때문에 이중 공진을 형성할 수 있고, 따라서 대역폭을 확장시킬 수가 있다. ENG ZOR 안테나는 전방향성의 방사 패턴을 갖지만, ENG ZOR 주파수와 $TM_{010}$의 주파수가 매우 근접해 있기 때문에 전방향성의 방사 패턴의 널 부분을 $TM_{010}$ 모드 방사가 보상해줄 수 있어 제안된 안테나는 지향성 방사 패턴을 갖는다. 제안된 안테나는 버섯 구조의 단위 셀을 각각 4개, 3개, 2개로 줄여나가면서 3가지 종류로 설계하여 특성을 분석하였다. 각각의 제안된 안테나는 비대역폭 $4.29{\sim}4.95 %$, 이득 3.16~5.57 dBi, 효율 62.4~94.2 %의 특성을 가지고 있다.

시판중인 불소 바니쉬의 불소이온 유리량 및 초기우식병소의 재광화 효과 비교 (A Comparison of the Amount of Fluoride Ion Released and Remineralization Effect on the Initial Caries Lesion of the Various Fluoride Varnishes)

  • 이가영;이상호;이난영;지명관
    • 대한소아치과학회지
    • /
    • 제43권4호
    • /
    • pp.443-451
    • /
    • 2016
  • 본 연구는 현재 시판되고 있는 불소 바니쉬 제품의 불소이온 유리 능력을 측정하고 이와 함께 정량 광 형광기를 이용하여 치질의 재광화 효과를 비교, 분석하였다. 평가하고자 하는 불소 바니쉬는 다음과 같은 6가지 제품을 대상으로 하였다; $FluoroDose^{(R)}$ (FD, Centrix Inc., USA), $Enamelast^{TM}$ (EL, Ultradent Product Inc., USA), $Clinpro^{TM}$ white varnish (CW, 3M ESPE, USA), $CavityShield^{TM}$ (CS, 3M ESPE, USA), V $varnish^{TM}$ (VV, Vericom, Korea), MI $varnish^{TM}$ (MI, GC, Japan). MI $varnish^{TM}$와 V $varnish^{TM}$에서 누적 불소이온 유리량과 재광화율이 가장 높게 나타난(p < 0.05) 반면 CS $varnish^{TM}$가 가장 낮은 누적 불소이온 유리량과 재광화율을 보였다(p < 0.05).

임플랜트 안정성을 위한 자기공명막대의 소독방법에 따른 수명에 관한 연구 (A study of $Smartpeg^{TM}'s$ lifetime according to sterilization for implant stability)

  • 원호연;조인호;이준석
    • 대한치과보철학회지
    • /
    • 제46권1호
    • /
    • pp.42-52
    • /
    • 2008
  • 임플랜트가 개발된 이후 임플랜트 안정성을 아기 위한 여러 방법들이 연구되어 왔고 여러 측정 장치들이 고안되어 왔다. 그 중에서도 공명주파수분석법(Resonance Frequency Analysis)을 이용한 방법이 요즘 각광을 받고 있다. 가장 최근에 공명주파수분석법을 이용한 측정 장치의 하나인 $Osstell^{TM}$ 보다 간편한 $Osstell^{TM}$ mentor의 출시로 임상적으로 더 편하게 임플랜트의 안정성을 측정 할 수 있게 되었다. 본 연구는 $Osstell^{TM}$ mentor 의 자기공명막대인 $Smartpeg^{TM}$을 사용할 때 임상에서 측정 가능한 측정횟수가 얼마나 되는지를 확인하고 또한 소독 후에도 측정값이 안정한지를 확인하고자 실험을 하였다. 실험 목적은 5가지로 나누어 알아보고자 하였다: 1. 자기공명막대의 반복측정의 영향: 자기 공명막대와 $Osstell^{TM}$ mentor를 고정시키고 반복적인 측정을 하여 몇 회까지 측정값이 안정한가? 2. 자기공명막대의 탈부착 반복의 영향: 자기공명막대를 탁부착을 반복하면서 몇회까지 측정값이 안정한가? 3. 자기공명막대의 소독방법에 따른 영향: 진료실내의 소독방법 후에도 자기 공명막대 측정값이 안정한가? 4. 자기 공명막대의 반복되는 고압증기멸균 소독 후의 영향: 고압증기 멸균법 10회 반복적인 소독 후에도 측정값이 안정한가? 5. 자기 공명막대의 자성소실온도 확인: 자기공명막대의 자성을 잃는 온도는 몇 도인가? 실험방법은 각 실험별 8개의 자기공명막대를 준비하고 각각의 구별을 위해 컬러펜으로 표식을 했으며 실험전 측정값을 재고, 실험후 측정값을 재어 비교하였다. 자기공명막대 반복측정의 영향을 알아본 실험은 최초의 측정값과 변화가 있는 횟수를 알아보려 했으며 측정값에 변화가 없을 경우 400회까지 측정하여, 1-100회, 101-200회, 201-300회, 301-400회 4군으로 나누어 유의수준을 살펴보았다. 자기공명막대 탈부착 반복의 영향을 알아본 실험은 자기 공명막대 8개를 각각 400회씩 탈부착하여 측정값의 변화를 1-100회, 101-200회, 201-300회, 301-400회 4군으로 나누어 군간 유의수준을 확인하였다. 자기공명막대 소독방법에 따른 영향에 대한 실험은 8개의 자기공명막대를 소독 전 측정값과 소독 후 측정값을 비교확인하였다. 자기 공명막대 반복되는 고압증기멸균 소독 후의 영향에 대한 실험은 8개의 자기공명막대를 10회 반복 소독하면서 소독 전 측정값을 0군, 1-10회까지 소독 후를 10군으로 나누어 군간 유의수준을 확인하였다. 자기공명막대 자성 소실 온도 확인실험은 8개의 자기 공명막대를 $138^{\circ}C$/10분, $150^{\circ}C$/5분, $150^{\circ}C$/10분으로 나누어 자기공명막대가 자성을 잃는 온도가 몇 도인지 실험하였다. 실험결과; 1. 자기공명막대 반복측정의 영향 실험에서는 각 군간 유의성이 없었다(p>0.05). 2. 자기공명막대 탈부착측정의 영향에 대한 실험은 각 군간 유의 확률이 0.123으로 유의성이 없었다(p>0.05). 3. 자기공명막대 소독방법에 따른 영향에 대한 실험은 소독 전 측정값과 소독 후 측정값의 유의성이 없었다(p>0.05). 4. 자기공명막대 반복되는 고압증기멸균소독 후의 영향에 대한 실험은 각 군간 유의성이 없었다.(p>0.05). 5. 자기공명막대 자성 소실온도확인 실험은 $138^{\circ}C$/10분에서는 소독 전, 후간 측정값에 유의성이 없었고(p>0.05), $150^{\circ}C$/5분에서는 2개가 측정 불가였으며, $150^{\circ}C$/10분에서는 8개 모두 ISQ값을 측정할 수가 없었다. 결론으로 말하면, 자기 공명막대가 나사산이 손상되지 않고 자성을 잃지 않으면 측정값이 변하지 않을 것으로 사료된다. 그리고 자기공명막대를 $150^{\circ}C$/10분에서 진공건열멸균 소독 후에 자성을 잃는 것으로 나타난 결과로 추론해 보건데, 진료실에서 가장 높은 온도를 보이는 고압증기멸균 소독이 $132^{\circ}C$/15분 이므로 진료실내의 소독방법들에는 아무런 문제가 없는 것으로 사료된다. 몇 번 사용할 수 있는지의 문제는 400번 측정 시 수치에 변화가 없으므로 측정되지 않을 때까지 사용해도 무방하리라 사료된다.

라디아타 소나무 수피로부터 제조한 PinuxTM염료의 화학조성과 견섬유와의 염색성 (Dyeability with Silk Fabrics and Chemical Composition of Natural Dye PinuxTM Manufactured from Pinus Radiata Balk)

  • 송경헌;문성필;김대성;홍영기
    • 한국생활과학회지
    • /
    • 제18권6호
    • /
    • pp.1315-1321
    • /
    • 2009
  • The chemical composition of natural powder dye $Pinux^{TM}$ manufactured from Pinus radiata bark and dyeability of dyed silk fabrics with $Pinux^{TM}$ were examined. It is made up of the optimum dyeing condition of silk fabric according to the dyeing concentration, dyeing time, and dyeing temperature. Also, we examined the colorfastness and antibiosis of dyed silk fabrics to washing, rubbing, perspiration and light. For the analysis of the chemical composition of $Pinux^{TM}$, the total contents of phenolic compound, proanthocyanidin(PA) and anti-oxidative activities of the dye were analyzed. As a result, it was found that the main components of the $Pinux^{TM}$ manufactured from Pinus radiata bark is proanthocyanidin, mostly a flavonoid containing a procyanidin structure, and it consists of approximately 63% phenol. As a result of examining the dyeability of silk fabrics with $Pinux^{TM}$, it showed that the dyeability was best under the conditions of the concentration of dye $1{\sim}1.5%$(wt/v%), dyeing time of 90 minutes, and dyeing temperature at $90^{\circ}C$. It was found that the colorfastness of dyed silk fabrics, colorfastness to washing, perspiration for acidic and rubbing were as good as grade 4 or 4-5. However, the colorfastness to light was low at grade 1, the same as the results of other natural dyed fabrics. As a result of the antibiosis measurement for the $Pinux^{TM}$-dyed silk fabrics, it showed high antibacterial properties to Staphylococcus sureus at 99.6%.

파목신 캅셀(아목시실린 500 mg)에 대한 곰실린 캅셀의 생물학적동등성 (Bioequivalence of GomcillinTM Capsule to FamoxinTM Capsule (Amoxicillin 500 mg))

  • 이윤영;최미희;이경률;이희주
    • Journal of Pharmaceutical Investigation
    • /
    • 제34권4호
    • /
    • pp.311-317
    • /
    • 2004
  • A bioequivalence study of $Gomcillin^{TM}$ capsules (DAEWOONG Pharmaceutical Co., Korea) to $Famoxin^{TM}$ capsules (Dong Wha Pharm. Ind. Co., Korea) was conducted according to the guideline of Korea Food and Drug Administration (KFDA). Twenty four healthy male Korean volunteers received each medicine at the amoxicillin dose of 500 mg in a $2{\times}2$ crossover study. There was a one-week wash out period between the doses. Plasma concentrations of amoxicillin were monitored by a high-performance liquid chromatography for over a period of 8 hours after the administration. $AUC_t$ (the area under the plasma concentration-time curve from time zero to 8 hr) was calculated by the linear trapezoidal rule method. $C_{max}$ (maximum plasma drug concentration) and $T_{max}$ (time to reach $C_{max}$) were compiled from the plasma concentration-time data. Analysis of variance was carried out using logarithmically transformed $AUC_t$ and $C_{max}$. No significant sequence effect was found for all of the bioavailability parameters indicating that the crossover design was properly performed. The 90% confidence intervals of the $AUC_t$ ratio and the $C_{max}$ ratio for $Gomcillin^{TM}/Famoxin^{TM}$ were $log0.91\;{\sim}\;log1.03$ and $;log0.93\;{\sim}\;log1.10$, respectively. These values were within the acceptable bioequivalence intervals of $log0.80\;{\sim}\;log1.25$. Thus, our study demonstrated the bioequivalence of $Gomcillin^{TM}$ and $Famoxin^{TM}$ with respect to the rate and extent of absorption.

Retrospective and Prospective Determination of the Cow's Milk-Related Symptom Score (CoMiSSTM) Values in Symptomatic Infants

  • Kozlowska-Jalowska, Anna;Horvath, Andrea;Vandenplas, Yvan;Szajewska, Hania
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • 제24권4호
    • /
    • pp.384-391
    • /
    • 2021
  • Purpose: The Cow's Milk-related Symptom Score (CoMiSSTM) was developed as an awareness tool for evaluating cow's milk-related symptoms in otherwise healthy children. Using a convenience sample of participants, this cross-sectional study aimed to determine CoMiSSTM values of symptomatic infants based on retrospectively or prospectively obtained information. Methods: CoMiSSTM values were determined in infants aged <12 months with symptoms suggestive of cow's milk protein allergy or functional gastrointestinal disorders. The exclusion criteria were previous diagnosis with acute or chronic disease, treatment with a therapeutic formula, and in case of breastfeeding, an elimination diet followed by the mother. Two CoMiSSTM values were assessed. A retrospective collection was defined as the collection of data after initial contact with the medical center but before the first medical consultation. A prospective collection was defined as the collection of data within 24 hours from the time of medical consultation but before starting any therapeutic intervention. The CoMiSSTM total and individual component scores obtained retrospectively or prospectively were compared between groups using the Wilcoxon signed-rank test. Results: This study was performed between August and November 2019. Data of 110 children (62 males and 48 females), with a mean±standard deviation age of 18.2±11.7 weeks, were obtained. The total CoMiSSTM value (p<0.001) and some individual component scores (crying, regurgitation, and stool) were significantly lower when collected prospectively than when collected retrospectively. Conclusion: CoMiSSTM values were retrospectively and prospectively determined. Lower CoMiSSTM values were obtained during prospective evaluation. Possible differences should be considered when using CoMiSSTM in clinical practice.

Physicochemical properties, cytotoxicity and penetration into dentinal tubules of sodium hypochlorite with and without surfactants

  • Hernan Coaguila-Llerena;Isadora Barbieri ;Mario Tanomaru-Filho ;Renato de Toledo Leonardo;Ana Paula Ramos ;Gisele Faria
    • Restorative Dentistry and Endodontics
    • /
    • 제45권4호
    • /
    • pp.47.1-47.11
    • /
    • 2020
  • Objectives: The aim of this study was to assess the physicochemical properties, cytotoxicity and penetration into dentinal tubules of ChlorCidTM Surf (3% sodium hypochlorite [NaOCl] with surfactant) in comparison to ChlorCidTM (3% NaOCl without surfactant). Materials and Methods: The physicochemical properties evaluated were pH, surface tension, free available chlorine (FAC) and contact angle. Cytotoxicity was evaluated in L929 fibroblasts exposed to the solutions by 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyl tetrazolium bromide and neutral red assays. Assessment of penetration into dentinal tubules was performed by staining single-rooted permanent human teeth with crystal violet (n = 9), which were irrigated with the solutions and analyzed in cervical, middle and apical segments. Data were analyzed by one-way analysis of variance (ANOVA) and Tukey's post-test, 2-way ANOVA and Bonferroni's post-test or t-test (α = 0.05). Results: ChlorCidTM Surf and ChlorCidTM FAC values were close to those indicated by the manufacturer. ChlorCidTM Surf showed lower surface tension and contact angle on dentin, and higher pH than ChlorCidTM (p < 0.05). The penetration of ChlorCidTM Surf was higher in cervical and middle segments, compared with ChlorCidTM (p < 0.05). There was no difference in irrigant cytotoxicity (p > 0.05). Conclusions: ChlorCidTM Surf showed lower surface tension, lower contact angle on root canal dentin, higher penetration into dentinal tubules and more alkaline pH, compared with ChlorCidTM. However, both solutions showed similar cytotoxicity and FAC content.

A군 연쇄구균성 인두편도염 진단을 위한 두 종류 신속항원검사법의 비교 (Comparison of Two Rapid Antigen Detection Tests for Diagnosis of Group A Streptococcal Pharyngotonsillitis)

  • 송승규;홍미애;오경창;안승인;태미현;신혜정;장진근;차성호
    • Clinical and Experimental Pediatrics
    • /
    • 제45권8호
    • /
    • pp.973-979
    • /
    • 2002
  • 목 적: A군 베타용혈성 연쇄구균은 급성 인두편도염의 원인이 되는 세균으로 류마티스성 열 및 사구체 신염과 같은 심각한 합병증을 유발할 수 있어 정확한 진단과 치료를 해야 하는 질병이다. A군 연쇄구균성 인두편도염은 증상만으로는 진단하기 어렵고, 가장 좋은 검사방법인 인두배양검사는 시간을 요하는 단점이 있다. 최근에 비교적 검사과정이 간단한 신속항원검사법을 이용할 수 있게 되었다. 이에 저자들은 두 종류의 신속항원검사법의 민감도와 특이도를 알아보고, 일치도를 평가하기 위해 본 연구를 시행하였다. 방 법: 2001년 11월부터 2002년 2월까지 한일병원 소아과 외래를 방문한 환자 중 인두의 발적과 부종, 인두의 삼출물, 인두의 점상 출혈이 있는 61명의 환자를 대상으로 인두배양검사와 신속항원검사를 시행하였다. 신속항원검사법은 BD $LINK2^{TM}$ Strep A(Becton, Dickinson & Company, U.S.A.)와 $QuickVue^{(R)}$ $In-LINK^{TM}$(Quidel Corporation, U.S.A.)를 사용하였다. 결 과 : 1) 61례의 검체 중 22례(36.1%)에서 인두배양검사상 A군 베타용혈성 연쇄구균이 배양되었다. 2) 집락수 1+는 2례(9.1%), 집락수 2+는 1례(4.5%), 집락수 3+는 10례(45.5%), 집락수 4+는 9례(40.9 %)로 배양되었다. 3) 인두배양검사에서 양성으로 나온 환자 중 3세에서 5세 사이가 14례(63.6%)로 본 연구에서 A군 연쇄구균성 인두편도염의 가장 흔한 연령층이었다. 4) 인두배양검사상 양성으로 나온 환자의 임상 증상 및 징후는 발열과 림프절 종대가 각각 18례(81.8%)에서 나타났고, 인두통 16례(72.7%), 구토 11례(50.0%), 성홍열양 피부발진 8례(36.4%), 두통 7례(31.8%), 복통 7례(31.8%), 딸기모양의 혀는 6례(27.7%)에서 관찰되었다. 5) 민감도는 BD $LINK2^{TM}$ Strep A가 81.8%(18례/22례), $QuickVue^{(R)}$ $In-LINK^{TM}$이 77.3%(17례/22례)이었다. 특이도는 BD $LINK2^{TM}$ Strep A가 89.7%(35례/39례), $QuickVue^{(R)}$ $In-LINK^{TM}$이 100%(39례/39례)이었다. 6) 양성 예측도는 BD $LINK2^{TM}$ Strep A가 81.8%, $QuickVue^{(R)}$ $In-Line^{TM}$이 100%이었다. 음성 예측도는 BD $LINK2^{TM}$ Strep A가 89.7%, $QuickVue^{(R)}$ In-Line$^{TM}$이 88.6%이었다. 7) 인두배양검사에 대한 BD $LINK2^{TM}$ Strep A의 k값은 0.72로 일치도 좋음을 보였고, $QuickVue^{(R)}$ $In-Line^{TM}$의 k값은 0.81로 일치도 아주 좋음을 나타냈다. 결 론 : 신속항원검사법인 BD $LINK2^{TM}$ Strep A와 $QuickVue^{(R)}$ $In-LINK^{TM}$은 민감도와 특이도, 일치도가 높을 뿐 아니라 신속하고 간편하게 결과를 알 수 있어서 인두배양검사와 병행하여 급성 인두편도염을 진단하고 치료하는데 많은 도움이 될 수 있을 것으로 사료된다.