• Title/Summary/Keyword: TM4

Search Result 1,649, Processing Time 0.029 seconds

A Research on the Regulations and Perception of Interactive Game in Data Broadcasting: Special Emphasis on the TV-Betting Game (데이터방송 인터랙티브 게임 규제 및 이용자 인식에 관한 연구: 승부게임을 중심으로)

  • Byun, Dong-Hyun;Jung, Moon-Ryul;Bae, Hong-Seob
    • Korean journal of communication and information
    • /
    • v.35
    • /
    • pp.250-291
    • /
    • 2006
  • This study examines the regulatory issues and introduction problems of TV-betting data broadcasts in Korea by in-depth interview with a panel group. TV-betting data broadcast services of card games and horse racing games are widely in use in Europe and other parts of the world. In order to carry out the study, a demo program of TV-betting data broadcast in the OCAP(OpenCableTM Application Platform Specification) system environment, which is the data broadcasting standard for digital cable broadcasts in Korea was exposed to the panel group and then they were interviewed after watching and using the program. The results could be summarized as below. First of all, while TV-betting data broadcasts have many elements of entertainment, the respondents thought that it would be difficult to introduce TV-betting in data broadcasts as in overseas countries largely due to social factors. In addition, in order to introduce TV-betting data broadcasts, they suggested that excessive speculativeness must be suppressed through a series of regulatory system devices, such as by guaranteeing credibility of the media based on safe security systems for transactions, scheduling programs with effective time constraints to prevent the games from running too frequently, limiting the betting values, and by prohibiting access to games through set-top boxes of other data broadcast subscribers. The general consensus was that TV-betting could be considered for gradual introduction within the governmental laws and regulations that would minimize its ill effects. Therefore, the government should formulate long-term regulations and policies for data broadcasts. Once the groundwork is laid for safe introduction of TV-betting on data broadcasts within the boundary of laws and regulations, interactive TV games are expected to be introduced in Korea not only for added functionality of entertainment but also for far-ranging development of data broadcast and new media industries.

  • PDF

A New Approach with Combined Stereotactic Trans-multiarc Beams for Radiosurgery Based on the Linear Accelerator : Photon Knife (입체적횡다증회전조사를 병합한 방사선수술의 새로운 접근 : 포톤나이프)

  • Choi, Tae-Jin;Kim, Jin-Hee;Kim, Ok-Bae
    • Radiation Oncology Journal
    • /
    • v.14 no.2
    • /
    • pp.149-158
    • /
    • 1996
  • Purpose : To get an accute steepness of dose gradients at outside the target volume in intracranial lesion and a less limitation of beam selection avoiding the high dose at normal brain tissue, this Photon Knife Radiosurgery System was developed in order to provide the three-dimensional dose distribution through the reconstruction of CT scan and the combined stereotactic trans-multiarc beam mode based on linear accelerator photon beam. Materials and methods : This stereotactic radiosurgery, Photon Knife based on linear accelerator photon beam was provided the non-coplanar multiarc and trans-multiarc irradiations. The stereotactic trans-multiarc beam mode can be obtained from the patient position in decubitus. This study has provided the 3-dimensional isodose curve and anatomical structures with the surface rendering technique. The dose distribution from the combined two trans-multiarcs (2M 2TM) was compared to that of four non-coplanar multiarcs (4M) with same collimator size of 25 mm in a diameter and total gantry movements. Results : In this study, it shows that the dose distributions of stereotactic beam mode are significantly depended on the selected couch and gantry angle in same collimator size. Practical dose distribution of combined stereotactic trans-multiarc beam has shown a more small rim thickness than that of the non-coplanar multiarc beam mode in axial, sagittal and coronal plane in our study. 3-Dimensional dose line displayed with surface rendering of irregular target shape is helpful to determine the target dose and to predict the prognosis in follow-up radiosurgery. Conclusions : 3-Dimensional dose line displayed with surface rendering of irregular target shape is essential in stereotactic radiosurgery. This combined stereotactic trans-multiarc beam has shown a less limitation of the selection couch and gantry beam angles for the target surrounding critical organs. It has shown that the dose distribution of combined trans-multiarc beam greatly depended on the couch and gantry angles. In our experiments, the absorbed dose has been decreased to $27%$ / mm in maximum at the interval of $50\%$ to $80\%$ of isodose line.

  • PDF

A STUDY ON THE POLYMERIZATION SHRINKAGE OF COMPOSITE RESIN ACCORDING TO VARIOUS LIGHT-CURING METHODS (광조사 방법에 따른 복합레진의 중합수축에 관한 연구)

  • Kwon, Oh-Jin;Kim, Jong-Soo;Kwon, Soon-Won
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.30 no.1
    • /
    • pp.102-109
    • /
    • 2003
  • The purpose of this study was to evaluate the linear polymerization shrinkage(%) and microhardness of composite resin(Z-100, 3M, USA) according to 2-step light curing method. Conventional light curing unit(Curing Light 2500, 3M USA) and 2-step light curing unit(Elipar Highlight, ESPE, Germany) were used as light source. The strain gauge method was used for determination of polymerization shrinkage(%). Samples were divided by 3 groups according to light curing methods (Group I : $450mW/cm^2$, 40sec, Group II : $650mW/cm^2$, 40sec, Group III : $150mW/cm^2$, 10sec & $650mW/cm^2$, 30sec). Preparations of acrylic molds were followed by filling and curing. Strain gauges attached to each sample were connected to a strainmeter. Measurements were recorded at each second for the total of 10 minutes including the periods of light application. And microhardness of each group after 24hours from light irradiation were measured. Obtained data were analyzed statistically using Ore-way ANOVA and/or Scheffe test. The results of the present study can be summarized as follows: 1. Composite resin in acrylic molds showed the initial expansion at the early phase of polymerization. This was followed by the contraction with the rapid increase in volume during the first 60 seconds and gradually diminished as curing process continued. 2. The lowest linear polymerization shrinkage(%) was found in group III followed by group I, II during the measuring periods. 3. Group III using 2-step curing method showed statistically significant reduction of linear polymerization shrinkage(%) compared with group I, II at 1 minute and 10 minutes from light irradiation(p<0.05). 4. The microhardness values of each group not revealed significant difference.

  • PDF

LONG-TERM EVALUATING OF THE REMINERALIZATION OF INTERPROXIMAL CARIES ADJACENT TO GLASS IONOMER RESTORATIONS: A MICRO-CT STUDY (미세 전산화 단층 촬영을 이용한 글라스 아이오노머 수복물의 인접면우식 재광화 효과에 관한 장기간 연구)

  • Lee, Hyeok-Sang;Kim, Young-Jae;Kim, Jung-Wook;Jang, Ki-Taeg
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.33 no.3
    • /
    • pp.498-503
    • /
    • 2006
  • This in vitro study compared the remineralization of incipient interproximal caries in the presence of three glass ionomer cements (highly-filled glass ionomer cement, compomer, resin-modified glass ionomer cement) and a resin composite(control). The long-term changes in remineralization caused by each material were evaluated by microtomography. Proximal restoration was simulated by placing tooth specimens and the various glass ionomer cements in closed containers with artificial saliva at $37^{\circ}C$ and pH 7.0 for 30 days with constant circulation Tomographic images were obtained with a micro CT scanner at 90, 180, and 270 days, and density-measuring software was used to calculate the micro-density of artificial caries lesions in the specimens. The mean density changes were compared between groups in order to evaluate the effects of remineralization. All data were analyzed using one-way ANOVA and the post-HOC Tukey multiple comparison test at p<0.05. While the density of artificial caries lesions increased for all treatments, the increases for the three glass ionomer groups were significantly higher than that for the resin group in each three month period. As time went on, the amount of density increase of the glass ionomer groups decreased, and significant differences were found between the remineralization effects of the glass ionomer groups.

  • PDF

Effects of Dissolved Oxygen and Depth on the Survival and Filtering Rate and Pseudofeces Production of a Filter-feeding Bivalve (Unio douglasiae) in the Cyanobacterial Bloom (남조류 대발생 환경에서 수심과 용존산소 변화에 따른 담수산 이매패(말조개)의 생존율, 여과율 및 배설물 생산)

  • Park, Ku-Sung;Kim, Baik-Ho;Um, Han-Yong;Hwang, Soon-Jin
    • Korean Journal of Ecology and Environment
    • /
    • v.41 no.spc
    • /
    • pp.50-60
    • /
    • 2008
  • We performed the experiment to evaluate the effect of different DO concentrations (0.5, 4.5 and 9.0 $mgO_2L^{-1}$) and water depths (20, 50 and 80 cm) on the filtering rate, mortality, and pseudifeces production of Unio douglasiae against the cyanobacterial bloom (mainly Microcystis aeruginosa). A solitary-living bivalve U. douglasiae was collected in the upstream region of the North Han River (Korea). The harvested mussels were carefully transferred to the laboratory artificial management system, which was controlled temperature $(18{\pm}2^{\circ}C)$, flow rate (10L $h^{-1}$), food $(Chlorella^{TM})$, sediment (pebble and clay), light intensity (ca. $20{\mu}mol$ photons), and photocycle (12 L : 12 D). In the field observation, the mussel mortality was significantly correlated with water temperature, pH and DO concentration (P<0.05). The mortality was decreased with water depth; 65, 90, 80% of mortality at 20, 50, 80 cm water-depth, respectively. Filtering rate (FR) showed the highest value at 50 cm water depth, and thereby the concentration of chlorophyll-${\alpha}$ decreased continuously by 94% of the control at the end of the experiment. In contrast, FR decreased by 34% of the initial concentration at 20 cm water depth. Over the given water-depth range, the mussel FR ranged from $0.15{\sim}0.20L\;gAFDW^{-1}hr^{-1}$ during the 18hrs of experiment, and thereafter, they appeared to be approximately 0.11, 0.26 and 0.30 L $gAFDW^{-1}hr^{-1}$ at 20, 50 and 80cm water depth, respectively. FR was highest with the value of 0.46L $gAFDW^{-1}hr^{-1}\;at\;0.5mgO_2 L^{-1}$ at the early stage of the experiment, while it increased with DO concentration. Maximum pseudofaeces production was 11.2 mg $gAFDW^{-1}hr^{-1}\;at\;9.0mgO_2L^{-1}$. Our results conclude that U. douglasiae has a potential to enhance water quality in eutrophic lake by removing dominant cyanobacteria, but their effects vary with environmental parameters and the water depth at which they are located.

Development of Yoghurt with Sanmeoru (Vitis amurensis Ruprecht) Wine as an Additive (산머루 와인을 첨가한 요구르트의 품질 특성)

  • Kim, Jae-Kyeoung;Lee, Jai-Sung;Jeong, Yu-Tae;Bae, In-Hyu
    • Journal of Dairy Science and Biotechnology
    • /
    • v.30 no.1
    • /
    • pp.23-30
    • /
    • 2012
  • This study was carried out to investigate the quality characteristics of yoghurt with varying contents of Sanmeoru (Vitis amurensis Ruprecht) wine (SW). Yoghurts were fermented with 2 kinds of lactic acid bacteria (Streptococcus thermophilus and Lactobacillus bulgaricus; Yo-$MIX^{TM5}505$, Danisco, Denmark). The changes in quality characteristics were investigated during fermentation and storage, and anthocyanin composition was analyzed after fermentation. The pH decreased in all treatments, while titratable acidity and viscosity gradually increased during fermentation. The viscosity of the yoghurt with 5.0% cultured SW added was higher than in other groups. The viable counts of lactic acid bacteria gradually increased during fermentation. The sample of the 5.0% cultured SW-yoghurt was higher than that of the other groups. The pH slowly decreased during the storage period; this was lower in the control yoghurt than in the yoghurts containing SW, and the changes of titratable acidity in the samples containing 5.0% and 30.0% cultured SW were lower than that in the yoghurt containing 1.0% cultured SW and in the control. The change in viscosity and number of viable cells during storage was higher in the yoghurts containing SW than in the control group. The levels of anthocyanin increased with the SW content in the yoghurt. Sensory scores for taste of the yoghurt with 1.0% added SW was significantly higher than for the other groups. Yoghurt with added SW kept at $4^{\circ}C$ for 12 days retained its quality characteristics fairly well.

  • PDF

The Etiological Role of Legionella Pneumophila in Patients with Community-Acquired Pneumonia in Korea (입원한 지역사회획득 폐렴 환자에서 요중 레지오넬라항원 검사를 통해 본 Legionella Pneumophila 감염의 비중)

  • Song, Hong-Seok;Suh, Ji-Hyeon;Ahn, Jong-Ho;Yoon, Byeong-In;Lee, Seung-Joon;Lee, Myung-Goo;Jun, Man-Jo;Kang, Min-Jong;Lee, Jae-Myung;Kim, Dong-Gyu;Son, Jee-Woong;Park, Myung-Jae;Hyun, In-Gyu;Jung, Ki-Suck
    • Tuberculosis and Respiratory Diseases
    • /
    • v.50 no.4
    • /
    • pp.409-414
    • /
    • 2001
  • Background : Legionella pneumophila has been recognized as an important cause of community-acquired pneumonia(CAP) requiring hospitalization. However, epidemiological data on the occurrence of legionella-related pneumonia is unavailable in Korea. The purpose of this study was to evaluate the etiological importance of legionella pneumophila serogroup 1 in patients hospitalized with CAP. Method : The CAP patients over 16 year-old were recruited from July 1999 to June 2000 at the Chunchon Sacred Heart Hospital. Fifty four patients (male 29, female 25, average age $63.8{\pm}15.3$) were included in this study. A diagnosis of a legionella pneumophila infection was based on a urinary antigen test using the Binax Company enzyme immunoassay. The severity of pneumonia was assessed using the Fine's PORT scoring system. Result : The average Fine's PORT score was 99.7(${\pm}44.9$). According to the risk classification proposed by the Infectious Disease Society of America, the number of patients in each class(from class I to class V) were 6(11.1%), 13(24.1%), 9(16.7%), 14(25.8%), and 12(22.2%), respectively. Thirty two patients(59.3%) were initially admitted to the intensive care unit. The mortality rate was 16.7%(9 in 54). In all patients, urinary antigens to Legionella pnewnophila serogroup 1 were not detected. Conclusion : Legionella pnewnophila may play little role in causing adult CAP in Korea. Therefore, the routine use of macrolide in the empirical treatment of the CAP patients based upon the ATS guidelines(1993) in Korea should be reevaluated.

  • PDF

How Reliable is Sputum PCR Test in the Diagnosis of Pulmonary Tuberculosis When Sputum Smear is Negative? (객담 결핵균 도말검사가 음성일때 중합효소연쇄반응검사와 진단적 신뢰도에 관한 연구)

  • Baek, Seung-Hoon;Lee, Jae-Myung;Kang, Min-Jong;Son, Jee-Woong;Lee, Seung-Joon;Kim, Dong-Gyu;Lee, Myung-Goo;Hyun, In-Gyu;Jung, Ki-Suck;Lee, Kyung-Wha;Joe, Hyun-Chan
    • Tuberculosis and Respiratory Diseases
    • /
    • v.50 no.2
    • /
    • pp.222-228
    • /
    • 2001
  • Backgrounds : Recent technological developments have introduced a new method to identifying M. tuberculosis complex DNA in clinical samples directly. The direct amplification test (DAT) is approved for identifying M. tuberculosis complex in respiratory specimens that are smear-positive for acid-fast bacilli (AFB). When there is a discrepancy between the AFB smear and DAT, no information on their clinical utility is currently available. In this study, the diagnostic reliability of DAT was investigated in suspected pulmonary tuberculosis patients whose sputum AFB smear was negative. Methods : From June 1, 1998 through May 30, 1999, 909 patients with presumed active pulmonary tuberculosis were enrolled. A sputum AFB stain, culture, DAT and/or biopsy were performed. Using the criteria of clinical tuberculosis or confirmed tuberculosis, the positive predictive value of DAT in diagnosing pulmonary tuberculosis was investigated. Results : The positive predictive value of DAT was 82.1% by the clinically active tuberculosis criteria. However, it decreased to 61.5% when diagnosis was restricted to only to culture positive or biopsy proven cases. The false positive rate of DAT was 18.0%. Conclusion : The DAT is a valuable diagnostic method in suspected patients whose sputum AFB is was negative.

  • PDF

Quality characteristics of soybean sprouts packaged with different packaging materials during their storage (포장 필름의 종류에 따른 저장 중 콩나물의 품질특성)

  • Hwang, Tae-Young
    • Food Science and Preservation
    • /
    • v.20 no.5
    • /
    • pp.602-607
    • /
    • 2013
  • Correct packaging enables processors to pack fresh produce and extend its shelf life. This study was carried out to investigate the effect of different packaging materials on the weight loss, pH, $O_2$, $CO_2$ and sensory characteristics of soybean sprouts during their storage at $5^{\circ}C$ for seven days. Soybean sprouts ($320{\pm}20g$) were packaged with oriented polypropylene (OPP) and cast polypropylene (CPP) films, respectively. The $O_2$ transmission rate of the packaging materials was set to have a control of $10,000cc/m^2$.day.atm, and an OP15 and CP15 with $15,000cc/m^2$.day.atm through a pre-screening test. The average weight loss of the soybean sprouts during their storage was less than 10%, and that of the soybean sprouts with a CPP film was higher than that of the OPP film. The pH of the soybean sprouts increased during their storage regardless of their packaging materials; but compared to the pH of the soybean sprouts packaged with OPP, those packaged with CPP were higher. The $CO_2$ content of the packaging increased with a decrease in the $O_2$ content. The ratio of $CO_2$ to $O_2$ in the soybean sprouts with the OPP film was 3.5 times higher than in the soybean sprouts with the CPP film. The results of the overall sensory test showed that the marketability of the soybean sprouts packaged with OPP film and stored at $5^{\circ}C$ seemed to have been maintained effectively for six days (at a $15,000cc/m^2$.day.atm $O_2$ transmission rate). When the correlation coefficients of the control, OP15 and CP15 were analyzed, the highest correlation was shown between a control and OP15 (0.986; p<0.01).

COMPARISON OF MICROLEAKAGE WITH THREE DIFFERENT ADHESIVE SYSTEMS (수 종의 복합레진 접착 시스템에서의 미세 누출의 비교)

  • Seok, Choong-Ki;Nam, Dong-Woo;Nam, Soon-Hyeun;Kim, Young-Jin;Kim, Hyun-Jung
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.31 no.4
    • /
    • pp.636-644
    • /
    • 2004
  • Recently, self-etching adhesive system have been developed and bonding procedures simplified into one or two steps, which are simultaneously applied to both enamel and dentin. These systems are easy to use and have the potential for good clinical success. The purpose of this study is to evaluate in vitro the microleakage on the cementum/dentin and enamel walls in composite resin restoration of Class V cavities, regarding the use of different adhesive systems. 30 human premolars were divided into 3 groups. A standardized Class V preparation was prepared on the buccal and lingual surface of each premolar. The preparation were made parallel to the cementoenamel junctions, with the gingival half of the preparation extending 1mm apical to the cementoenamel junction. After adhesive system was applied to teeth as manufacture's recommendation, hybrid resin composite was filled in bulk into the preparation and light polymerized according to manufacturer's recommendations. Specimen were stored in distilled water at $37^{\circ}C$ for 5 days and thermocycled 1000 times ($5^{\circ}C{\pm}2^{\circ}C\;and\;55^{\circ}C{\pm}2^{\circ}C)$, then immersed in a 2% methylene blue solution for 12 hours. After sectioning mesio distally through the restorations, the degree of dye penetration was scored under a stereomicroscope at ${\times}\;25$ magnification. The data were analyzed statistically using t-test and one-way ANOVA. The results were as follows: ${\cdot}$ There is no adhesive system which can prevent microleakage perfectly. ${\cdot}$ There is significant difference in microleakage between enamel margin and dentin margin (p<0.0001). ${\cdot}$ In enamel margin, self-etching primer systems did not show any significant difference comparing total-etching system. In denin margin, self-etching primer systems did not show any significant difference comparing one-bottle adhesive system used in combination with total-etching.

  • PDF