• Title/Summary/Keyword: TM Joint

Search Result 58, Processing Time 0.025 seconds

CRANIUM-ORIENTED MAXILA AND CONDYLE POSITIONING DEVICE (두개골에 기준을 둔 상악 및 과두 고정용 장치)

  • Lee, Won-Hak;Hong, Kwang-Jin;Lee, Jeong-Gu;Sohn, Hong-Bum;Cho, Yun-Ju
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.21 no.1
    • /
    • pp.29-34
    • /
    • 1999
  • Special attention should be directed toward the preservation of preoperative condylar position during orthognathic surgery because their positional change may leads to postoperative skeletal relapse as well as TM joint problem. Various condylar positioning devices, therefore, have been introduced and utilized in orthognathic surgery. Even though most of them provided us with improvement of surgical results, we also found some problems including limited indication, etc. For more accurately repositioning the maxilla and the mandible and its wide versatility, a newly designed maxilla and condylar positioning device based on the fixed part of cranium is introduced.

  • PDF

Optimal Design of the Forging Processes of Flare Nut for Automobiles using Finite Element Analysis (유한요소해석에 의한 승용차용 플레어 너트 단조공정의 최적설계)

  • 추덕열;한규택
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.28 no.1
    • /
    • pp.83-89
    • /
    • 2004
  • Flare nut is an important Part that used to joint a brake tube-end in automobiles. It was made of SWCH 10A by machining. But we studied to make it by metal forming. The main focus of this paper is to investigate an optimal forging processes for flare nut using the DEFORM$^{TM}$-3D. commercially available finite element code and tests. Actually an explicit finite element analysis of the flare nut forging processes has been carried out to predict an optimal shape of the flare nut and its results were reflected in the tests of the forging processes design for flare nut. The simulation results which had obtained from finite element analysis were contributed to the forging processes design for flare nut. An optimal shape of nave nut showed agreements with test results. Furthermore. this paper should contribute to a development of the forging process for a variety of parts.s.

Block Shape Adaptive Candidate List Derivation for Inter Prediction in Versatile Video Coding (VVC) (VVC 의 블록모양 적응적 화면간 예측 후보 리스트 유도 기법)

  • Do, JiHoon;Park, Dohyeon;Kim, Jae-Gon;Jeong, Dae-Gwon
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2018.06a
    • /
    • pp.257-259
    • /
    • 2018
  • 최근 JVET(Joint Video Experts Team)는 새로운 비디오 압축 표준을 VVC(Versatile Video Coding)으로 이름 짓고 2020 년 완료를 목표로 그 표준화를 시작하였다. HEVC 및 VVC 에서는 화면간 예측의 부호화 효율을 위하여 공간적/시간적 주변블록의 움직임 정보로부터 Merge/AMVP(Advanced Motion Vector Prediction)의 후보 리스트를 구성하고 최적의 움직임 정보를 활용한다. 본 논문에서는 Merge/AMVP 의 후보 리스트를 유도할 때, 현재블록의 모양을 고려하여 상관성이 높은 주변블록의 움직임 정보를 우선 순위로 유도하는 기법을 제안한다. 실험을 통하여 VTM(VVC TM) 대비 제안기법의 성능을 확인한다.

  • PDF

Positional change of the condylar heads after wearing complete denture on dental cone beam CT (치과용 콘빔 CT영상에서 총의치 장착 후 하악과두의 위치변화)

  • Lee, Bong-Ho;Kim, Jae-Duk;Chung, Chae-Heon
    • Imaging Science in Dentistry
    • /
    • v.38 no.1
    • /
    • pp.23-27
    • /
    • 2008
  • Purpose: The aim of this study was to evaluate the change in the position of the mandibular condyle within articular fossa by a CBCT after wearing complete denture (CD). Materials and Methods: CBCT of 34 temporomandibular joints were taken from 9 male and 8 female patients with CB $Mercuray^{TM}$ (Hitachi, Japan) before and after wearing a CD for rehabilitation. Position of mandibular condyle within articular fossa at centric occlusion was evaluated with $Vimplant2.0^{TM}$ (CyberMed, Korea) on the central parasagittal view and curved panoramic coronal view of the condylar head. A statistical evaluation was done with SPSS. Results: The range of anteroposterior positional rate (AP) of condylar head within articular fossa was -16-5 and -10-12 respectively on the right and left sides. Before wearing CD, the AP rate showed discrepancy between right and left sides (p<0.05). After wearing CD, both condyles showed a tendency to decrease in posterior condylar position (right side; p<0.05). The average discrepancy between right and left side in mediolateral positional rate (MD) was 15.5 and 4.5 respectively before and after wearing CD. The improvement was observed in mediolateral relationship of both condylar heads after wearing CD (p< 0.01). Before wearing CD, the average horizontal angle of long axis of condylar head was $79.6{\pm}2.7^{\circ}\;and\;80.1{\pm}5.7^{\circ}$ respectively on the right and left sides. After wearing CD, both condyles were rotated in the same direction in average on axial plane. Conclusion: We observed with CBCT the significant clinical evidence in case of positional change of mandibular condyle after wearing complete denture.

  • PDF

A Study on the Masticatory Efficiency after Treament for Temporomandibular Disorders (측두하악장애 치료후 저작능률에 관한 연구)

  • Nam, Cheon-Woo;Han, Kyung-Soo
    • Journal of Oral Medicine and Pain
    • /
    • v.24 no.4
    • /
    • pp.439-453
    • /
    • 1999
  • This study was performed to investigate the masicatory efficiency in patients with temporomandibular disorders (TMDs), especially internal derangement of temporomandibular (TM) joint. For this study, 26 patients after treatment and 33 dental students who had no signs and symptoms of TMDs were selected as the patients group and as the normal group, respectively. Mean treatment duration of the patients was. 5.1 months. Verbal rating scale(VRS) and Visual analogue scale(VAS) were used for recording of subjective symptoms. Treatment index (VAS Ti) derived from VAS was calculated for evaluation of treatment progress and clinical examination was also performed for objective symptoms. BioEGN(Bioresearch Inc., Milwaukee, USA) was used for observation chewing movement pattern on peanut, caramel candy, and gum chewing. Chewing time in second and symptoms after chewing were recorded, and pattern of chewing stroke between in affected side and in contralateral side or between in right in left side were compared, and especially, gum chewing pattern between before and after treatment were also compared in the patients group. The data obtained were analysed by SPSS windows program and the results of this study were as follows : 1. Subjective symptoms evaluated by VAS showed no difference between the two groups, but those by VRS showed slight difference for TM joint pain, head not neck symptoms, and chewing ability. 2. There were no difference at the level of subjective symptoms between the subgroups divided by treatment duration of five months in the patients group. However, value of VAS Ti of pain was higher in subgroup of long treatment duration than that of subgroup of short treatment duration. 3. There were no difference in chewing time for peanut or caramel candy between the two groups, but on caramel candy chewing, the patients group complained slight discomfort after swallowing. Chewing velocity and range of motion on gum chewing after treatment in the patients group showed significant difference and greatly improved compared to those to before treatment, and which were not differ from those of normal subjects. In conclusion, treatment of temporomandibular disorders about for five months would greatly improve chewing ability and movement pattern in most of the patients with TMDs.

  • PDF

Electro-rheological Measurements of Phase Inversion of Emulsions under Shear Flow (전단응력 하에서 에멀젼 상 변이의 측정을 위한 전기 유변학적 연구)

  • Seung Jae, Baik;Young-Jin, Lee;Yoon Sung, Nam;Chin Han, Kim;Han Kon, Kim;Hak Hee, Kang
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.30 no.2
    • /
    • pp.147-151
    • /
    • 2004
  • This study aims at measuring electrical and rheological properties of cosmetic emulsions on the skin under shear flow. The effects of volume ratio and surfactants on structural changes of emulsions were examined by determining the changes of electrical resistance, viscosity, and morphology. As the ratio of the internal phase increased, the phase inversion occurred more quickly. The viscosity change was found to increase with increasing of the variation of electrical resistance of the emulsions. This phenomenon may be caused by decreased resistant force against the shear flow because of the breakdown of the internal phase. Surfactants a]so played a key ro]e on phase transition of emulsions. It is likely that polymeric surfactants anchoring on the emulsion surface reinforced the interfacial mechanical strength. As the concentration of surfactants increased, the phase transition occurred more slowly. It has been demonstrated that the phase changes of emulsions under shear flow can be monitored on the real-time basis by using a JELLI$\^$TM/ chip system, a combination of conductiometry and rheometry. Our approach is expected to a useful experimental tool for predicting the phase transition of the cosmetic products during skin application.

Bioabsorbable Screws Used in Hallux Valgus Treatment Using Proximal Chevron Osteotomy (무지외반증 환자의 근위 갈매기형 절골술에서 생체 흡수성 나사못을 이용한 고정)

  • Shin, Woo-Jin;Chung, Young-Woo;An, Ki-Yong;Seo, Jae-Woong
    • Journal of Korean Foot and Ankle Society
    • /
    • v.22 no.4
    • /
    • pp.181-183
    • /
    • 2018
  • Hallux valgus is a deformity that causes pain in the first metatarsophalangeal joint. Surgical methods are quite diverse and a range of osteotomies are used at the proximal and distal part of the metatarsal bone and proximal phalange. Fixation methods, such as plate, screw, K-wire, and others have been used in various ways. The fixation device is often removed with various side effects due to the fixation devices. In the case of instruments that are absorbed in vivo, these procedures are not necessary to remove and there is an advantage of not performing the second operation. Three patients were treated, in which a proximal chevron osteotomy was used with a bioabsorbable screw (K-$MET^{TM}$; U&I Corporation).

Measurement of Muscle Strength of Ankle Joint Using Isokinetic Dynamometer in Normal Korean Adults (등속성 운동검사를 이용한 정상 한국인 성인에서의 발목관절 근력 측정)

  • Choi, Seung-Myung;Park, Ji-Kang;Ha, Yoon-Won;Cho, Byung-Ki
    • Journal of Korean Foot and Ankle Society
    • /
    • v.19 no.4
    • /
    • pp.142-150
    • /
    • 2015
  • Purpose: Restoration of ankle stability through the strengthening exercise of peroneus muscles is considered an important factor for achievement of successful outcomes, in the rehabilitation program following ankle ligament injuries. However, there were few definitive data on normal muscle strength, including eversion power by peroneus muscles. This study was conducted to evaluate the muscle strength of ankle joint measured using an isokinetic dynamometer in normal Koreans. Materials and Methods: Sixty adults (120 ankles) were recruited and divided into three groups (20 in their twenties, 20 in thirties, and 20 in forties). Each group consisted of 10 males and 10 females. The selection criteria were no history of ankle injury and no evidence of instability. The peak torque, total work, and deficit ratio were measured using the Biodex$^{TM}$ (Biodex Medical Systems). Differences in muscle strength by age, gender and dominant versus non-dominant side were analyzed. Results: The peak torque of dorsiflexion was average 31.5 Nm at $30^{\circ}/s$ of angular velocity and 18.8 Nm at $90^{\circ}/s$; average 69.3 Nm ($30^{\circ}/s$) and 42.4 Nm ($90^{\circ}/s$) on plantarflexion; average 19.6 Nm ($30^{\circ}/s$) and 10.8 Nm ($90^{\circ}/s$) on inversion; average 12.9 Nm ($30^{\circ}/s$) and 8.0 Nm ($90^{\circ}/s$) on eversion. The deficit ratio of strength in women was average 61.1% of men on dorsiflexion; average 66.2% on plantarflexion; average 48.5% on inversion; average 55.4% on eversion. The deficit ratio in non-dominant foot was average 88.6% of dominant foot on dorsiflexion; average 90.1% on plantarflexion; average 85.1% on inversion; average 85.6% on eversion. Conclusion: The muscle strength of the ankle joint showed a tendency to weaken with age. There were significant differences in muscle strength by gender and dominancy. Further studies for comparison of patients with ankle instability, a comparison between before and after surgery for instability, the correlation between clinical outcomes and the recovery in muscle strength will be needed.

A COMPUTER ANALYSIS ON THE CONDYLAR PATH OF BALANCING SIDE IN MANDIBULAR LATERAL MOVEMENT (하악 측방운동시 평형측 과두의 운동 궤적에 관한 컴퓨터 분석)

  • Lee Dong-Hyun;Choi Dae-Gyun;Park Nam-Soo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.31 no.4
    • /
    • pp.549-564
    • /
    • 1993
  • The purpose of this study was to research the condylar path and the anterior angle of glenoid fossae and classify the patterns of condylar path. Thirty male and female dental students with normal occlesion and masticatory system ranging in age from 21 to 30, without present symptoms and an)r history of TM joint disturbance, were selected for this study. Transcranial radiographs of TM joints under mandibular lateral movement were obtained. By the computer analysis on the radiographs, the angle of posterior slope of articular eminance, the sagittal condylar guidance angie, condylar movement patterns and the height of glenoid fossa was measured respectively, and studied their interrelationship comparatively. The results obtained were as follows : 1. The total distance of condylar movement on balancing side during mandibular lateral movement was 4.55mm for Lt. and 4.78mm for Rt. when mandible moved from C.R. to canine to canine relation and 7.86mm for the Lt. and 8.10mm for the Rt. when mandible moved from C.R. to 7.5mm. 2. The horizontal distance of condylar movement on balancing side during mandibular lateral movements was 3.16mm for the Lt. and 3.52mm for the Rt. when mandible moved from C.R. to canine to canine relation and 6.10mm for the Lt. and 6.30mm for the Rt. when mandible moved from C.R. to 7.5mm. 3. The sagittal condylar guidance angle on balancing side during mandibular lateral movements was $45.96^{\circ}$ for the Lt. and $43.22^{\circ}$ for the Rt. when mandible moved from C.R. from canine to canine relation and $41.14^{\circ}$ for the Lt. and $39.77^{\circ}$ for the Rt. when mandible moved from C.R. to 7.5mm. 4. The height of glenoid fossa was 8.23mm for the Lt. and 7.80mm for the Rt. and the angle of posterior slope of articular eminence was $38.30^{\circ}$ for the Lt. and $38.79^{\circ}$ for the Rt. by method-A and $55.61^{\circ}$ for the Lt. and $55.64^{\circ}$ for the Rt. by method-B. 5. The sequence of the frequency of condylar movement patterns on balancing side during mandibular lateral movement were concave type(30 cases), convex type(16 cases), reverse S shape curve(9 cases) and S shape curve(5 cases) when mandible moved from C.R. to canine to canine relation and concave type(27 cases), 5 shape curve(13 cases), convex type(11 cases) and reverse S shape curve(9 cases) when mandible moved from C.R. to 7.5mm.

  • PDF

Effect of Groove Conditions on the Mechanical Properties of Welds Produced by the Combined Welding Process of Flux Cored Arc and Electro Gas in EH36 TMCP Steel Plate for Hull Structures (선체구조용 EH36 TMCP 후판의 FCAW 및 EGW 조합 용접부 기계적 성질에 미치는 개선조건의 영향)

  • Kim, Kihyuk;Kim, Kiwon;Sim, Hoseop;Bae, Kangho;Hong, Hyunuk;Park, Byunggyu
    • Journal of Welding and Joining
    • /
    • v.33 no.5
    • /
    • pp.35-40
    • /
    • 2015
  • Characterization of microstructures and mechanical properties of 83mm thickness EH36-TM welds produced by the combined flux cored arc (FCA) and electro gas (EG) welding processes has been studied with the two different groove conditions, single-V (SV) and double-V (DV) bevels. The welding consumables used for FCA and EG welding processes were ASME/AWS A5.29 (E81T1-K2) and A5.26 (EG72T), respectively. Experimental results showed that all the mechanical properties of welds such as tensile property, CVN toughness and Vickers hardness met IACS requirements. The tensile strength of EG welded plates were reduced by approximately 4% (DV: 3.8%, SV: 4.2%) compared to the base metal. The hardness value of SV-beveled weld metal was slightly lower than that of DV-beveled one. There were no significant differences as per welding groove conditions except for the weld metal. In addition, at the fusion line, the toughness of SV condition was 20J lower and the weld metal was 40J lower than DV condition, respectively. On the basis of microstructural analysis, grain boundary ferrite (GBF) structures for SV condition were 2 times higher volume fraction than for DV condition and their packet sizes were coarsened to almost double. It was thus suggested that the GBF volume fractions and packet sizes in the weld metal of EH36-TM steel plates are the most important factors affecting the mechanical properties of the combined FCA and EG welded joint. Nevertheless, all the results of welds with both DV and SV conditions were found to be excellent.