• Title/Summary/Keyword: TLC(SOS)

Search Result 2, Processing Time 0.015 seconds

Detection of Sulfa-Drugs and Antibiotics Residues in Raw Milk (원유중의 잔류항생물질 및 썰파제 조사)

  • 박병옥;백미순;권기호;우기방;장기윤
    • Korean Journal of Veterinary Service
    • /
    • v.14 no.1
    • /
    • pp.63-69
    • /
    • 1991
  • Antibiotic residues of raw milks collected in Anyang area were tested by TTC-reduction test, EEC-4plate method and TLC(SOS-kit ) method to improve and monitor the quality of milk. Antibiotic substances were not detected from 100 raw milk samples, but sulfamethazine was detected from only one sample(1.3PPM) by SOS test. Unclassified anti-microbic substances were detected from 22 samples by EEC-4 plate method. EEC-4 plate test was useful to categorize the species of antibacterial substances and SOS test was useful to detect the sulfamethazine field screening test.

  • PDF

Detection of residual antibiotics by TLC and EEC-4 plate method in slaughtered pigs (도축돈에서 TLC와 EEC-4 plate법을 이용한 항생물질 잔류조사)

  • 권오성;김순태;김영욱;손재권
    • Korean Journal of Veterinary Service
    • /
    • v.20 no.3
    • /
    • pp.313-321
    • /
    • 1997
  • The antibiotic residues of the urine, the liver, the lung, the kidney and the spleen in slaughtered pigs at Kyongbuk province were detected by TLC(505 kit) and EEC-4 plate method. 1. The positive rate of residual sulfamethazine which was detected by 505 kit in the urine (n=200) was 0.0%. 2. The positive rate of residual sulfamethazine which was detected by EEC-4 plate in the urine (n=126), the liver(n=98), the kidney(n=72), the spleen (n=68) and the lung(n=48) were 63%, 49%, 36%, 34% and 24%, respectively. 3. By EEC-4 plate method, the positive detection rates of the urine were 53.0% in BS(pH 6.0), 29.0% in BS(pH 7.2), 11.5% in BS(pH 8.0) and 13.0% in ML(pH 8.0) medium, that of the liver 41.5% in BS(pH 6.0), 22.0% in BS(pH 7.2), 6.5% in BS(pH 8.0) and 5.0%, in ML (pH 8.0) medium, that of the lung 21.0% in BS(pH 6.0), 9.5%, in BS(pH 7.2) and 8.5% in BS(pH 8.0) medium, and that of the kidney 31.5% in BS(pH 6.0), 14.5% in BS(pH 7.2), 20.0% in BS(pH 8.0) and 3.0% in ML(pH 8.0) medium. In the spleen, only in BS(pH 6.0) medium the positive rate was detected as 33.5 %. 4. The positive rates of samples which shown TLC-positive detected by EEC-4 plate method were 53.9% in no band, 77.8% in one band, 80.9% in two bands, 66.7% in three bands, respectively. In conclusion, the EEC-4 plate method could be applied for the detection of residual antibiotics in samples which shown as out of standard Rf values by TLC-method (SOS kit).

  • PDF