• Title/Summary/Keyword: TL Analysis

Search Result 285, Processing Time 0.2 seconds

Analysis of Heavy Metals in $[^{201}Tl]$TICI Injection Using Polarography (폴라로그래피를 이용한 $[^{201}Tl]$염화탈륨 주사액의 중금속 분석)

  • Chun, Kwon-Soo;Suh, Yong-Sup;Yang, Seung-Dae;Ahn, Soon-Hyuk;Kim, Sang-Wook;Choi, Kang-Hyuk;Lee, Dong-Hoon;Lim, Sang-Moo;Yu, Kook-Hyun
    • The Korean Journal of Nuclear Medicine
    • /
    • v.34 no.4
    • /
    • pp.336-343
    • /
    • 2000
  • Purpose: Thallous-201 chloride produced at Korea Cancer Center Hospital(KCCH) is used in detecting cardiovascular disease and cancer. Thallium impurity can cause emesis, catharsis and nausea, so the presence of thallium and other metal impurities should be determined. According to USP and KP, their amounts must be less than 2 ppm in thallium and 5 ppm in total. In this study, the detection method of trace amounts of metal impurities in $[^{201}Tl]$TICI injection with polarography was optimized without environmental contamination. Materials and Methods: For the detection of metal impurities, Osteryoung Square Wave Stripping Voltammetry method was used in Bio-Analytical System (BAS) 50W polarograph. The voltammetry was composed of Dropping Mercury Electrode (DME) as a working electrode, Ag/AgCl as a reference electrode and Pt wire as a counter electrode. Square wave stripping method, which makes use of formation and deformation of amalgam, was adopted to determine the metal impurities, and pH 7 phosphate buffer was used as supporting electrolyte. Results: Tl, Cu and Pb in thallous-201 chloride solution were detected by scanning from 300 mV to -800 mV Calibration curves were made by using $TINO_3,\;CuSO_4\;and\;Pb(NO_3){_2}$ as standard solutions. Tl was confirmed at -450 mV peak potential and Cu at -50 mV Less than 2 ppm of Tl and Cu was detected and Pb was not detected in KCCH-produced thallous-201 chloride injection. Conclusion: Detection limit of thallium and copper is approximately 50 ppb with this method. As a result of this experiment, thallium and other metal impurities in thallous-201 chloride injection, produced at Korea Cancer Center Hospital, are in the regulation of USP and KP Polarograph could be applied for the determination of metal impurities in the quality control of radiopharmaceuticals conveniently without environmental contamination.

  • PDF

Analysis of Resonant MTM-TL Using Transmission Line Theory and Its Applications (전송 이론을 이용한 공진 MTM-TL 특성 분석 및 응용)

  • Jang, Seong-Nam;Lee, Bom-Son
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.20 no.10
    • /
    • pp.1091-1096
    • /
    • 2009
  • Some closed-form expressions for circuit parameters are derived based on the equivalent circuits for the resonant MTM-TL(open and short). The lumped series resistance and shunt conductance, which explain radiation effects of a unit cell may be found by |$S_{11}$|(simulated or measured) with open and short terminations, respectively. The EM-simulated results, circuit-simulated results(obtained using extracted circuit parameters) and measurement results are shown to be in good agreement.

Defect of $^{18}F-FDG$ Uptake Observed in Infarcted Myocardium Showing Reverse Redistribution on Rest / 24-Hour Delayed $^{201}Tl$ Myocardial SPEG after Acute Myocardial Infarction (급성 심근경색 후 휴식 / 24시간 지연 $^{201}Tl$ 심근 SPECT 상 역재분포를 보인 경색심근에서 관찰된 $^{18}F-FDG$ 섭취 결손)

  • Lee, Ho-Young;Paeng, Jin-Chul;Oh, So-Won;Kim, Ji-Yeong;Chung, Woo-Young
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.6
    • /
    • pp.478-481
    • /
    • 2008
  • Reverse redistribution is frequently observed after revascularization in acute myocardial infarction, and usually regarded as a predictor of viable myocardium on stress/rest and 2- to 4-hour redistribution $^{201}Tl$ SPECT. However, there is not enough report of reverse redistribution in case of 24-hour delayed SPECT, which is commonly used for viability assessment. In this report, a case of reverse redistribution on rest and 24-hour delayed $^{201}Tl$ SPECT is reported with use of automatic segmental quantitative analysis. The myocardium of reverse redistribution was dysfunctional on gated SPECT, and diagnosed as non-viable on $^{18}F-FDG$ PET.

Acoustic Transmission Loss Measurement of the Exhaust System with TL Tube (TL 튜브를 이용한 소음기의 음향 전달 손실 계측법)

  • 류윤선;김윤석;이성홍
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.770-773
    • /
    • 2004
  • The transmission loss coefficient is very important acoustic property in parallel with absorption and acoustic impedance categorizing the acoustical materials, which can control the acoustical problems. At the same time, the transmission loss coefficient is a key parameter to choose the optimum material for the analysis of acoustical characteristics of material using SEA(Statistical Energy Analysis). In this paper, the acoustic transmission loss measurement system using 4-microphone TL tube is applied to the exhaust system, which is one of the most important acoustic control parameters in a car, based on the idea calculating the full transfer matrix. The theoretical background and measurement system are introduced, and finally the measurement results are verified.

  • PDF

Detection Characteristics of PSL and TL Methods in Spices Irradiated with Different Radiation Sources (조사선원에 따른 향신료의 PSL과 TL 검지 특성)

  • Kim, Kyu-Heon;Kwak, Ji-Young;Kim, Jung-Ki;Hwang, Cho-Rong;Lee, Jae-Hwang;Park, Yong-Chjun;Kim, Jae-I;Jo, Tae-Yong;Lee, Hwa-Jung;Lee, Sang-Jae;Han, Sang-Bae
    • Journal of Radiation Industry
    • /
    • v.7 no.1
    • /
    • pp.15-21
    • /
    • 2013
  • The detection characteristics of irradiated spices were investigated depending on radiation sources and doses by photostimulated luminescence (PSL) and Thermoluminescence (TL). 6 kinds of spices (turmeric, onion powder, red pepper, basil, parsley, black pepper) were irradiated at 0 to 10 kGy under ambient conditions by both a $^{60}Co$ gamma irradiator and an electron beam (EB) accelerator, respectively. The PSL analysis showed negative results for non-irradiated spices, while irradiated spices gave intermediate and positive value, which presented the limited potential of PSL technique. In TL measurement, TL glow curves on non-irradiated samples appeared at about $300^{\circ}C$ with low intensity. All irradiated samples were easily distinguishable through radiation-specific strong TL glow curves with maximum peak in range of $150{\sim}200^{\circ}C$. TL ratio ($TL_1/TL_2$) obtained by a re-irradiation step could verify the detection result of $TL_1$ glow curves, showing ratios lower than 0.1 in the non-irradiated sample and higher than 0.1 in irradiated ones. Therefore, in PSL measurement, the identification of irradiated spices showed more clear results in electron beam irradiated samples. TL analysis showed obvious difference between non-irradiated and irradiated samples in gamma ray and electron beam irradiated samples.

Monitoring microbiological contamination, pre-decontamination, and irradiation status of commercial dried laver (Porphyra sp.) products (시판 유통 김의 미생물 오염도, 사전 살균처리 및 전자선 조사 여부 확인)

  • Lee, Eun-Jin;Kim, Gui-Ran;Lee, Hye-Jin;Kwon, Joong-Ho
    • Korean Journal of Food Science and Technology
    • /
    • v.49 no.1
    • /
    • pp.20-27
    • /
    • 2017
  • Eighteen commercial laver (Porphyra sp.) products were purchased from Korean market and were monitored for their microbial contamination, pre-decontamination, and luminescence properties. The laver samples showed considerable variation in their microbial contamination, from $10-10^7CFU/g$ of total aerobic counts, <$10-10^2CFU/g$ of coliforms in 4 dried laver samples, and <$10-10^6CFU/g$ of yeasts and molds except in 3 samples. In addition, $10^2CFU/g$ of Bacillus cereus was found in one sample. DEFT/APC analysis was suitable for demonstrating whether the samples were pre-decontaminated or not, with DEFT/APC values lower than 2.0 log for non-heated samples and 1.0-8.5 log for heatprocessed samples. In photostimulated luminescence (PSL) calibration, 15 samples irradiated at 1 kGy showed positive (irradiated) values more than 5000 PCs. Furthermore, thermoluminescence (TL) analysis by separating the marker minerals from samples revealed the potential to be employed in identifying irradiation status by determining $1^{st}$ TL glow at $125-175^{\circ}C$ and TL ratio ($TL_1/TL_2$) of all the samples.

Studies on the Applications of TL and ESR Methods for the Detection of Spices, Berry Fruits and Pollen Extract Product (TL과 ESR 분석을 통한 일부 향신료, 장과류 및 화분가공추출물 검지 특성 연구)

  • Kim, Kyu-Heon;Son, Jin-Hyok;Kang, Yoon-Jung;Park, Hye-Young;Kwak, Ji-Young;Lee, Jae-Hwang;Park, Yong-Chjun;Jo, Tae-Yong;Lee, Hwa-Jung;Lee, Sang-Jae;Han, Sang-Bae
    • Journal of Radiation Industry
    • /
    • v.7 no.1
    • /
    • pp.69-74
    • /
    • 2013
  • This study examined radiation detection characteristics of spices (cumin, caper and turmeric), other small fruits (hut-gae berry and boxthorn), and pollen extract product. Each samples were irradiated at dose of 1, 5, and 10 kGy and analyzed by the thermoluminescence (TL) and electron spin resonance (ESR) methods. To compare between non-irradiated and irradiated food, all samples were irradiated with $^{60}Co$ gamma-ray source. In TL analysis, most of samples could be applied to detect irradiated foods because of showing TL ratio above 0.1. The glow curves examined by TL method were estimated in the range of $150{\sim}250^{\circ}C$ in irradiated samples. In ESR measurements, the intensity of ESR signal (single-line) increased as the increase of irradiation dose. In particular, the specific ESR signals of irradiation-induced radical were detected in hut-gae berry and pollen extract product. As a results, it is considered that TL and ESR methods can be used to detect both hut-gae berry and pollen extract product. But cumin, caper, turmeric and boxthorn irradiated with gamma ray could be detected only by TL method. It is concluded that TL and ESR methods are suitable for detection of irradiated samples and a combined method is recommendable for enhancing the reliability of detection results.

Identification of Irradiated Food Additives by Photostimulated Luminescence (PSL) Method (Photostimulated Luminescence (PSL) 방법에 의한 국내 유통 분말형 식품가공원료의 방사선 조사 여부 모니터링)

  • Yun, Hyejeong;Hur, Jungmu;Yang, Suhyung;Lee, Byoung-Hun;Kwon, Joong-Ho;Kim, Dongho
    • Journal of Radiation Industry
    • /
    • v.2 no.1
    • /
    • pp.27-34
    • /
    • 2008
  • Photostimulated luminescence (PSL), electron spin resonance (ESR) and thermoluminescence (TL) analyses were conducted to detect whether 258 kinds of extracted and powdered forms food additives were irradiated or not. In a view of the PSL results, 9 kinds of the extracted and powdered samples (3.2%) showed over 5,000 photon counts $(60sec)^{-1}$ and these samples were judged to be irradiation-positive. Thirty nine kinds of the samples (15.6%) yielded 700~5,000 photon counts $(60sec)^{-1}$ and these samples were grouped into irradiation-potential, while the samples showed below 700 photon counts $(60sec)^{-1}$ sec were judged to be irradiation-negative. TL glow curves for minerals separated from 5 samples were detected at $150^{\circ}C$ with high intensity. However, TL analysis did not apply to other irradiation-positive and irradiation-potential samples because the minerals for TL detection were not separated from the samples. ESR measurements for irradiation-positive and irradiation-potential samples, judged by PSL detection, showed no specific signals to irradiation. The results indicated that PSL could be applied to identify irradiation treatment of extracted and powdered food additives, while TL was optional and ESR was not suitable for detection extracted and powdered food additives.

The Development of Earthenware Kilns in Bongsan-ri Archaeological Site, Osong: Implications for Pre- and Post-1950 AD Absolute Age Determination (AD 1950년 전후 고고유적의 절대연대측정에 대한 고찰: 오송 봉산리 옹기가마 유적을 중심으로)

  • Kim, Myung Jin;Son, Myoung Soo;Kim, Tae Hong;Sung, Ki Seok
    • Journal of Conservation Science
    • /
    • v.34 no.6
    • /
    • pp.481-492
    • /
    • 2018
  • We conducted TL/OSL dating for the earthenware kilns in the Bongsan-ri archaeological site, Osong, which was occupied from the late nineteenth to the late twentieth century. With the SAR-TL/OSL method, paleodose was determined from the equivalent dose during the burial period($ED_{burial}$), the background dose($ED_{BG}$), the fading correction factor(f), and the overestimation correction factor(C). The annual dose rates and their provenance were evaluated from the measurement of natural radionuclides $^{238}U$, $^{232}Th$, and $^{40}K$. Because the comprehensive absolute age was provided by combining the resulting TL/OSL and radiocarbon data, we concluded that, for the absolute chronology of a modern archaeological site, TL/OSL dating and radiocarbon dating must be carried out together and summed. The construction and occupation of earthenware kilns in the Bongsan-ri site had changed from stage I (No.5, 6 kilns), to stage II (No.1, 2, 3 kilns), to stage III (No.4) in chronological order. When Bayesian statistics were applied, we found that the absolute ages of occupation for stages I, II, and III correspond to AD $1910{\pm}23$, AD $1970{\pm}10$, and AD $1987{\pm}4$. These results were in good agreement with the archaeological context or chronology.

Reproducibility of Gated Myocardial Perfusion SPECT for the Assessment of Myocardial Function: Comparison with Thallium-201 and Technetium-99m-MIBI (심근 기능 측정에 사용된 게이트 심근 관류 SPECT 방법의 재현성 평가: $^{201}Tl$$^{99m}Tc$-MIBI 게이트 SPECT의 비교)

  • Hyun, In-Young;Seo, Jeong-Kee;Hong, Eui-Soo;Kim, Dae-Hyuk;Kim, Sung-Eun;Kwan, Jun;Park, Keum-Soo;Choe, Won-Sick;Lee, Woo-Hyung
    • The Korean Journal of Nuclear Medicine
    • /
    • v.34 no.5
    • /
    • pp.381-392
    • /
    • 2000
  • Purpose: We compared the reproducibility of $^{201}Tl\;and\;^{99m}Tc$-sestamibi (MIBI) gated SPECT measurement of myocardial function using the Germano algorithm Materials and Methods: Gated SPECT acquisition was repeated in the same position in 30 patients who received $^{201}Tl$ and in 26 who received $^{99m}Tc$-MIBI. The quantification of end-diastolic volume (EDV), end-systolic volume (ESV), and ejection fraction (EF) on $^{201}Tl\;and\;^{99m}Tc$-MIBI gated SPECT was processed independently using Cedars quantitative gated SPECT software. The reproducibility of the assessment of myocardial function on $^{201}Tl$ gated SPECT was compared with that of $^{99m}Tc$-MIBI gated SPECT Results: Correlation between the two measurements for volumes and EF was excellent by the repeated gated SPECT studies of $^{201}Tl$ (r=0.928 to 0.986; p<0.05) and $^{99m}Tc$-MIBI (r=0.979 to 0.997; p<0.05). However, Bland Altman analysis revealed the 95% limits of agreement (2 SD) for volumes and EF were tighter by repeated $^{99m}Tc$-MIBI gated SPECT (EDV: 14.1 ml, ESV: 9.4 ml and EF: 5.5%) than by repeated $^{201}Tl$ gated SPECT (EDV: 24.1 ml, ESV: 18.6 ml and EF: 10.3%). The root mean square (RMS) values of the coefficient of variation (CV) for volumes und EFs were smaller by repeated $^{99m}Tc$-MIBI gated SPECT (EDV: 2.1 ml, ESV 2.7 ml and EF: 2.3%) than by repeated $^{201}Tl$ gated SPECT (EDV: 3.2 ml, ESV: 3.5 ml and EF: 5.2%). Conclusion: $^{99m}Tc$-MIBI provides more reproducible volumes and EF than $^{201}Tl$ on repeated acquisition gated SPECT. $^{99m}Tc$-MIBI gated SPECT is the preferable method for the clinical monitoring of myocardial function.

  • PDF