• Title/Summary/Keyword: TL

Search Result 1,459, Processing Time 0.023 seconds

Determination of energy resolution for a NaI(Tl) detector modeled with FLUKA code

  • Demir, Nilgun;Kuluozturk, Zehra Nur
    • Nuclear Engineering and Technology
    • /
    • v.53 no.11
    • /
    • pp.3759-3763
    • /
    • 2021
  • In this study, 3" × 3" NaI(Tl) detector, which is widely used in gamma spectroscopy, was modeled with FLUKA code, and calculations required to determine the detector's energy resolution were reported. Photon beams with isotropic distribution with 59, 81, 302, 356, 511, 662, 835, 1173, 1275, and 1332 keV energy were used as radiation sources. The photon pulse height distribution of the NaI(Tl) without influence of its energy resolution obtained with FLUKA code has been converted into a real NaI(Tl) response function, using the necessary conversion process. The photon pulse height distribution simulated in the conversion process was analyzed using the ROOT data analysis framework. The statistical errors of the simulated data were found in the range of 0.2-1.1%. When the results, obtained with FLUKA and ROOT, are compared with the literature data, it is seen that the results are in good agreement with them. Thus, the applicability of this procedure has been demonstrated for the other energy values mentioned.

Spin-Orbit Density Functional Theory Calculations for TlAt with Relativistic Effective Core Potentials

  • Choi, Yoon-Jeong;Bae, Cheol-Beom;Lee, Yoon-Sup;Lee, Sang-San
    • Bulletin of the Korean Chemical Society
    • /
    • v.24 no.6
    • /
    • pp.728-730
    • /
    • 2003
  • Bond lengths, harmonic vibrational frequencies and dissociation energies of TlAt are calculated at ab initio molecular orbital and density functional theory using effective spin-orbit operator and relativistic effective core potentials. Spin-orbit effects estimated from density functional theory are in good agreement with those from ab initio calculations, implying that density functional theory with effective core potentials can be an efficient and reliable methods for spin-orbit interactions. The estimated $R_e$, $ω_e$ and $D_e$ values are 2.937 ${\AA}$, 120 $cm^{-1}$, 1.96 eV for TlAt. Spin-orbit effects generally cause the bond contraction in Group 13 elements and the bond elongation in the Group 17 elements, and spin-orbit effects on Re of TlAt are almost cancelled out. The spinorbit effects on $D_e$ of TlAt are roughly the sum of spin-orbit effects on $D_e$ of the corresponding element hydrides. Electron correlations and spin-orbit effects are almost additive in the TlAt molecule.

Comparison of Muscle Activities of Thoracic and Lumbar Extensors during Trunk Lift Exercises According to Exercise Position (운동 자세에 따른 몸통 들기 운동 시 가슴과 허리 폄 근육의 근활성도 비교)

  • Koh, Eun-Kyung;Jung, Do-Young
    • Korean Journal of Applied Biomechanics
    • /
    • v.22 no.3
    • /
    • pp.341-348
    • /
    • 2012
  • The purpose of this study was to compare the muscle activities of the thoracic extensor(TE) and lumbar extensor(LE) during trunk lift (TL) exercise according to exercise position. Seventeen healthy subjects with no medial history of back pain were recruited for this study. Subjects performed the TL exercise in prone, quadruped and heel-sitting positions. The activities of the TE and LE were measured using surface electromyography during TL exercise in each exercise position. A one-way repeated-measures analysis of variance (ANOVA) was used to compare the normalized muscle activities of the TE and LE and the TE/LE ratio. The results showed that there was not significant effect of exercise position on the muscle activities of TE(p>.05). However, there was significant effect of exercise position on the muscle activities of LE and the TE/LE ratio(p>.05). Post hoc pair-wise comparisons with Bonferroni correction showed that both muscle activities of LE and TE/LE ratio in prone position were significantly different in those in heel-sitting and quadruped positions, during TL exercise, respectively. The TE/LE ratio was the greatest for TL exercise in heel-sitting position. Therefore, for selective activation of the TE muscle, we recommend performing the TL exercise in heel-sitting or quadruped position.

Vision-based Automatic System for Non-contact Measurement of Morphometric Characteristics of Flatfish

  • Jeong, Seong-Jae;Yang, Yong-Su;Lee, Kyounghoon;Kang, Jun-Gu;Lee, Dong-Gil
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.5
    • /
    • pp.1194-1201
    • /
    • 2013
  • This paper introduces a vision-based automatic system (VAMS) for non-contact measurement of morphometric characteristics of flatfish, such as total length (TL), body width (BW), height (H), and weight (W). The H and W are simply measured by a laser displacement and a load cell, respectively. The TL and BW are measured by a proposed morphological image processing algorithm. The proposed algorithm cans measurement, when the tail of flatfish is deformed, and when it is randomly oriented. In the experiment, the average and maximum measurement errors were recorded, and standard deviations and coefficients of variation (CVs) for the measurements were calculated. From those results, when flatfish the TL measurements had an average of 266.844 mm, a standard deviation of 0.351 mm, a CV of 0.131%, and a maximum error of 0.87 mm with straightened flatfish ($TL_A$ : 267 mm, $BW_A$ : 141 mm), and when flatfish of different sizes were measured, the errors in the TL and BW measurements were both about 0.2 %. Using a single conveyor, the VAMS can process up to 900 fishes per hour. Moreover, it can measure morphometric characteristics of flatfish with a TL of up to 500 mm.

Development of a position sensitive CsI(Tl) crystal array

  • Shi, Guo-Zhu;Chen, Ruo-Fu;Chen, Kun;Shen, Ai-Hua;Zhang, Xiu-Ling;Chen, Jin-Da;Du, Cheng-Ming;Hu, Zheng-Guo;Fan, Guang-Wei
    • Nuclear Engineering and Technology
    • /
    • v.52 no.4
    • /
    • pp.835-840
    • /
    • 2020
  • A position-sensitive CsI(Tl) crystal array coupled with the multi-anode position sensitive photomultiplier tube (PS-PMT), Hamamatsu H8500C, has been developed at the Institute of Modern Physics. An effective, fast, and economical readout circuit based on discretized positioning circuit (DPC) bridge was designed for the 64-channel multi-anode flat panel PSPMT. The horizontal and vertical position resolutions are 0.58 mm and 0.63 mm respectively for the 1.0 × 1.0 × 5.0 ㎣ CsI(Tl) array, and the horizontal and vertical position resolutions are 0.86 mm and 0.80 mm respectively for the 2.0 × 2.0 × 10.0 ㎣ CsI(Tl) array. These results show that the CsI(Tl) crystal array with low cost could be applied in the fields of medical imaging and high-resolution gamma camera.

Physical and Microbiological Approach in Proving the Identity of Gamma-irradiated Different Teas

  • Kausar, Tusneem;Kim, Byeong-Keun;Kim, Dong-Ho;Kwon, Joong-Ho
    • Food Science and Biotechnology
    • /
    • v.14 no.1
    • /
    • pp.1-5
    • /
    • 2005
  • Photostimulated luminescence (PSL), thermoluminescence (TL), electron spin resonance (ESR), and direct epiflourescent filter technique/aerobic plate count (DEFT/APC) were applied to detect dried green, black, and oolong teas irradiated between 0-10 kGy. Teas irradiated at 2.5 kGy and higher showed over 5000 photon counts/60 sec, while non-irradiated teas yielded 650-1000 photon counts/60 sec. TL glow curves for minerals separated from teas were detected at about $300^{\circ}C$ with low intensity in non-irradiated samples, whereas around $150^{\circ}C$ with high intensity in all irradiated samples. Ratio of $TL_1/TL_2$ based on re-irradiation step, showing lower than 0.1 and higher than 1.44 for non-irradiated and irradiated samples, respectively, enhanced reliability of TL results. ESR measurements for irradiated teas showed signals specific to irradiation. Log DEFT/APC ratio increased with irradiation dose; this result could be applied to identify irradiated tea samples.

Structure design of Csl-Se Detector using Monte Carlo Simulation (몬테카를로 시뮬레이션을 통한 Csl-Se 검출기의 구조 설계)

  • Park, Ji-Koon;Kang, Sang-Sik;Choi, Jang-Young;Lee, Hung-Won;Nam, Sang-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.11a
    • /
    • pp.420-423
    • /
    • 2002
  • In recent years, there has been keen interest in developing f1at panel detectors for all modalities of radiology, including gerneral radiology, fluoroscopy(angiography and cardiology), electronic portal imaging, and mammography. In this paper, we report the new hybrid x-ray detector consisted of CsI(Tl) photoemission layer and a-Se photoconductor layer to resolve conventional x-ray detector such as the direct detector using a-Se and the indirect detector using CsI(Tl)/a-Si. To design the structure of CsI(Tl)/a-Se detector, the penetrated energy spectrum and absorption fraction was estimated using MCNP 4C code. Experimental results showed that the absorption fraction of $500{\mu}m-Se$ film and $150{\mu}m-CsI\left(Tl \right)/a-Se\left( 30{\mu}m \right)$ film is 70% at 70 kVp. The absorption energy is 90% at $350{\mu}m-CsI(Tl)$.

  • PDF

Effects of Fluid Velocity on Acoustic Transmission Loss of Simple Expansion Chamber (유동속도가 단순확장관 음향투과손실에 미치는 영향 해석)

  • Kwon, Jin;Jeong, Weui-Bong;Hong, Chin-Suk
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.22 no.10
    • /
    • pp.994-1002
    • /
    • 2012
  • Acoustic power transmission loss(TL) is an important performance of the muffler system. TL will be affected by the velocity of the fluid in duct since acoustic pressure varies according to the fluid velocity. In this paper, two kinds of fluid model, potential flow and turbulent flow, for the fluid flowing in simple expansion chamber are considered. The effects of their two fluid models in acoustic TL are investigated for the straight and L-shaped simple expansion chamber. In higher frequency range, the characteristics of TL of the two fluid models show different results. The variation of TL according to the fluid velocity is shown more distinctly when turbulence model is used. Turbulent flow model should be used to obtain better estimation of acoustic TL in higher frequency range.

Evaluation of TlBr semiconductor detector in gamma camera imaging: Monte Carlo simulation study

  • Youngjin Lee;Chanrok Park
    • Nuclear Engineering and Technology
    • /
    • v.54 no.12
    • /
    • pp.4652-4659
    • /
    • 2022
  • Among the detector materials available at room temperature, thallium bromide (TlBr), which has a relatively high atomic number and density, is widely used for gamma camera imaging. This study aimed to verify the usefulness of TlBr through quantitative evaluation by modeling detectors of various compound types using Monte Carlo simulations. The Geant4 application for tomographic emission was used for simulation, and detectors based on cadmium zinc telluride and cadmium telluride materials were selected as a comparison group. A pixel-matched parallel-hole collimator with proven excellent performance was modeled, and phantoms used for quality control in nuclear medicine were used. The signal-to-noise ratio (SNR), contrast to noise ratio (CNR), sensitivity, and full width at half maximum (FWHM) were used for quantitative analysis to evaluate the image quality. The SNR, CNR, sensitivity, and FWHM for the TlBr detector material were approximately 1.05, 1.04, 1.41, and 1.02 times, respectively, higher than those of the other detector materials. The SNR, CNR and sensitivity increased with increasing detector thickness, but the spatial resolution in terms of FWHM decreased. Thus, we demonstrated the feasibility and possibility of using the TlBr detector material in comparison with commercial detector materials.

Normal Limits of Left Ventricular Volumes and Ejection Fraction Measured by Gated Myocardial Perfusion SPECT: Comparison of Tc-99m MIBI and Tl-201 (심근 게이트 SPECT로 측정한 좌심실 용적과 구혈률의 정상 값 확립: Tl-201과 Tc-99m MIBI 게이트 SPECT의 비교)

  • Hyun, In-Young;Seo, Jeong-Kee;Kwan, Jun;Park, Keum-Soo;Choe, Won-Sick;Lee, Woo-Hyung
    • The Korean Journal of Nuclear Medicine
    • /
    • v.37 no.3
    • /
    • pp.147-152
    • /
    • 2003
  • Purpose: We evaluated radioisotope and sex-specific differences of normal limits for left ventricle volumes (LWs) and ejection fraction (EF) using myocardial perfusion gated SPECT (g-SPECT). Materials and Methods: Rest Tl-201/post-stress Tc-99m MIBI g-SPECT measurements with acquisitions of 8-frame were evaluated for 70 patients (mean age $55{\pm}14.56%$ female) who either had < 10% pretest likelihood of CAD (n = 12) or had normal coronary angiography (EF > 50%) (n = 58). LVEF, LWs were automatically determined by quantitative gated SPECT using QGS program. Results: Similar results were obtained for mean LVEF between Tc-99m MIBI ($62%{\pm}7%$ and Tl-201 ($63%{\pm}8%$) g-SPECT measurements. In Contrast, Tl-201 g-SPECT had significantly lower LWs values ($EDV;\;74{\pm}23mL,\;ESV;\;28{\pm}14mL$) than Tc-99m MIBI g-SPECT ($EDV;\;82{\pm}25mL,\;ESV;\;32{\pm}15mL$) (p<0.05). Women had significantly lower EDV ($Tc-99m\;MIBI;\;71{\pm}18mL,\;Tl-201;\;65{\pm}17mL$), and ESV values ($Tc-99m\;MIBI;\;27{\pm}10mL,\;Tl-201;\;23{\pm}8mL$) compared with EDV ($Tc-99m\;MIBI;\;96{\pm}27mL,\;Tl-201;\;85{\pm}24mL$), and ESV Values ($Tc-99m\;MIBI;\;40{\pm}17mL,\;Tl-201;\;36{\pm}16mL$) of men (p<0.05). Women had significantly higher LV EF Values ($65%{\pm}7%$) than men ($60%{\pm}8%$) by Tl-201 gated SPECT (p<0.05). Conclusion: These data suggest significant differeuces in normal limits for LWs and EF, according to genders and radiopharmaceutical. Therefore, the evaluation of cardiac function in patients should consider radioisotope and sex-matched normal values.