• Title/Summary/Keyword: TKA

Search Result 53, Processing Time 0.361 seconds

Safety of Temporary Use of Recycled Autoclaved Femoral Components in Infected Total Knee Arthroplasty: Confirming Sterility Using a Sonication Method

  • Park, Hyung-Jin;Kim, Hee-June;Kim, Shukho;Kim, Seong-Min;Mun, Jong-Uk;Kim, Jungmin;Kyung, Hee-Soo
    • Clinics in Orthopedic Surgery
    • /
    • v.10 no.4
    • /
    • pp.427-432
    • /
    • 2018
  • Background: The purpose of this study was to evaluate the usefulness of sonication technique for microbiological diagnosis and the sterility of the recycled autoclaved femoral components from infected total knee arthroplasty (TKA) using a sonication method. Methods: Nineteen femoral implants explanted from patients with infected TKA were sterilized with a standard autoclave method. Standard culture of the fluid before and after sonication of the sterilized implants was performed to detect pathogenic microorganisms. Additional experiments were performed to evaluate the sterility of the recycled implant by inducing artificial biofilm formation. Methicillin-resistant Staphylococcus aureus (MRSA) was inoculated into 10 implants and sterilization in a standard autoclave was performed, and then the fluid was cultured before and after sonication. Results: Two of the 19 sterilized implants were positive for growth of bacteria after sonication, whereas no growth was detected in the cultured fluid from the sterilized implants before sonication. The bacteria were Staphylococcus species in all two cases. In one of 10 implants inoculated with MRSA, the culture was positive for growth of bacteria both before and after sonication. However, Staphylococcus epidermidis was cultured from both occasions and thus this implant was thought to be contaminated. Conclusions: We found sonication for identification of pathogens could be helpful, but this finding should be interpreted carefully because of the possibility of contamination. Sterilization of an infected femoral implant with an autoclave method could be a good method for using the temporary articulating antibiotic spacer in two-stage revision arthroplasty.

The analgesic efficacy of the continuous adductor canal block compared to continuous intravenous fentanyl infusion with a single-shot adductor canal block in total knee arthroplasty: a randomized controlled trial

  • Kim, Min Kyoung;Moon, Hyoung Yong;Ryu, Choon Gun;Kang, Hyun;Lee, Han Jun;Shin, Hwa Yong
    • The Korean Journal of Pain
    • /
    • v.32 no.1
    • /
    • pp.30-38
    • /
    • 2019
  • Background: The adductor canal block (ACB) is an effective intervention for postoperative analgesia following total knee arthroplasty (TKA). However, the ideal ACB regimen has not yet been established. We compared the analgesic effects between a continuous ACB group and fentanyl-based intravenous patient-controlled analgesia (IV-PCA) with a single-shot ACB group. Methods: Patients who underwent TKA were randomly allocated to either a continuous ACB group (Group CACB) or IV-PCA with a single-shot ACB group (Group IVACB). Before the surgery, ultrasound guided ACB with 0.5% ropivacaine 20 cc was provided to all patients. Before skin incision, the infusion system (0.2% ropivacaine through an adductor canal catheter in group CACB vs. intravenous fentanyl in group IVACB) was connected. The postoperative pain severity; the side effects of local anesthetics and opioids; administration of rescue analgesics and anti-emetics; and sensorimotor deficits were measured. Results: Postoperative pain severity was significantly higher in the IVACB group at 30 min, 4 h, 24 h, and 48 h after surgery. The averages and standard deviations (SD) of the NRS score of postoperative pain were $0.14{\pm}0.37$, $4.57{\pm}2.37$, $6.00{\pm}1.63$, and $4.28{\pm}1.49$, respectively in the IVACB group. Rescue analgesic requirements and quadriceps muscle strength were not statistically different between the groups throughout the postoperative period. Moreover, rescue antiemetic requirements were higher in group IVACB than group CACB. Conclusions: In this study, the continuous ACB provided superior analgesia and fewer side effects without any significant motor deficit than the IV-PCA with a single-shot ACB.

The Effect of Cycle Ergometer Exercise Inducing Movement of the Affected Side on Knee Joint Function after Total Knee Arthroplasty (환측사용유도 고정식자전거운동이 무릎관절 기능에 미치는 영향: 무릎인공관절수술 환자를 대상으로)

  • Choi, Eun-Ji;Lee, Sang-Yeol
    • PNF and Movement
    • /
    • v.20 no.1
    • /
    • pp.91-101
    • /
    • 2022
  • Purpose: The purpose of this study was to examine the effect of cycle ergometer exercise inducing movement of the affected side on knee joint function after total knee arthroplasty (TKA). Methods: The primary experiment was conducted on 19 members of the cycle ergometer exercise group to measure the muscle activity of the rectus femoris, hamstring, tibialis anterior, and gastrocnemius muscles during cycle ergometer exercise that induced the affected side's movement. In the second experiment, after receiving physiotherapeutic intervention for 30 min, the general bicycle exercise group and cycle ergometer exercise group performed the corresponding exercise for 15 min, 5 times per week, for 2 weeks. The ROM, muscle strength, pain, and balance were then measured and compared between the two groups. Results: In the results of the primary experiment, cycle ergometer exercise inducing movement of the affected side showed a significantly larger increase in the activity of leg muscles (rectusfemoris, hamstring, tibialis anterior, gastrocnemius) on the affected side than the general bicycle exercise (p <0.05). In the second experiment, the cycle ergometer exercise group showed a significantly larger increase in range of movement of affected side knee flexion and muscle strength of affected side knee flexion, knee extension, and plantarflexion than the general bicycle exercise (p <0.05). No significant between-group difference was observed in pain and balance before or after the intervention (p >0.05). Conclusion: Cycle ergometer exercise inducing movement of the affected side increases use of the muscles around the affected side knee joint after TKA more than general bicycle exercise and produces better effects for enhancing muscle strength. The application of cycle ergometer exercise inducing movement of the affected side is expected to reduce the patients' unbalanced use during the early postoperative period and help them to quickly return to normal daily life through rapid muscle strength recovery.

Osteolysis-Related Bioabsorbable Suture Anchor Fixation in a Medial Collateral Ligament Avulsion Fracture during Total Knee Arthroplasty (슬관절 인공관절 치환술 중 발생한 내측 측부 인대 견열 골절에 대해 생흡수성 봉합 나사못을 이용한 고정 후 발생한 골용해)

  • Huh, Jung-Wook;Park, Man-Jun;Hong, Seong-Hwak;Park, Joon-Hyung
    • Journal of the Korean Orthopaedic Association
    • /
    • v.55 no.6
    • /
    • pp.545-549
    • /
    • 2020
  • Although rare, the treatment options for a medial collateral avulsion fracture during total knee arthroplasty (TKA) range from conservative management using a cast and orthosis to internal fixation using metal screws. Bioabsorbable suture anchors have been used to replace metal fixators with distinct advantages, such as biocompatibility, radiolucency, and unnecessary second removal surgery, but complications, such as osteolysis, have been reported. This paper reports a potential risk of an extensive osteolysis-related suture anchor fixation of a medial collateral ligament (MCL) avulsion fracture during TKA in conjunction with a literature review.

Clinical and radiologic study of total knee replacement arthroplasty using Doujet GF bone cement (liquid-powder bone cement containing gentamicin) (Doujet GF 골 시멘트를 사용한 인공 슬관절치환술의 임상적, 방사선적 고찰)

  • Sungwook Choi;Seong-meen Yoon;Joseph Y. Rho;In-seok Son
    • Journal of Medicine and Life Science
    • /
    • v.20 no.2
    • /
    • pp.60-66
    • /
    • 2023
  • Gentamicin-loaded bone cement used in total joint arthroplasty is indispensable, as it provides stability by directly binding the surfaces of implants and bones. Depending on multiple factors, including the material of the bone cement used, common complications, such as aseptic loosening, osteolysis, and infection can occur postoperatively. In clinical practice, Doujet bone cement is easy to handle (pre-packed all-in-one system), and has shown low failure rates and non-inferior results compared with similar available products. We conducted a retrospective comparative study to analyze the clinical and radiological results of each bone cement group to establish the safety and usefulness of Doujet bone cement. From July 2020 to July 2022, we enrolled 198 patients in this study after an average follow-up period of 37 months (range, 6-48 months). In 99 patents, Doujet® bone cement (Injecta, Gunpo, Korea) was used for total knee arthroplasty (TKA), while Refobacin® bone cement (Biomet, Warsaw, IN, USA) was used in 99 patients. The average range of motion (ROM) of the knee increased by 2.4° (from 127.0° preoperatively to 129.4° postoperatively) in the Doujet group, and by 0.1° (from 128.7° to 128.8°) in the Refobacin group (P=0.701). The Western Ontario and McMaster Universities (WOMAC) osteoarthritis index scores decreased from 44.1 to 7.8 in the Doujet group, and from 44.2 to 6.3 in the Refobacin group (P=0.162). Complications, such as osteolysis or post-operative wound infection, did not occur in more than two cases in both groups. The WOMAC and ROM of the knee in both groups had no clinical differences. Both Doujet and Refobacin similarly showed low complication rates after TKA.

Role of the Gastrocnemius Musculocutaneous with a Propeller Style Skin Flap in Knee Region Reconstruction: Indications and Pitfalls

  • Gianluca Sapino;Rik Osinga;Michele Maruccia;Martino Guiotto;Martin Clauss;Olivier Borens;David Guillier;Pietro Giovanni di Summa
    • Archives of Plastic Surgery
    • /
    • v.50 no.6
    • /
    • pp.593-600
    • /
    • 2023
  • Background Soft tissue reconstruction around the knee area is still an open question, particularly in persistent infections and multiple reoperations scenario. Flap coverage should guarantee jointmobility and protection, even when foreign materials are implanted. The chimeric harvesting of the musculocutaneous gastrocnemius flap, based on the sural artery perforators, can extend its applicability in soft tissue reconstruction of the upper leg, overcoming the drawbacks of the alternative pedicled flaps. Methods A multicenter retrospective study was conducted enrolling patients who underwent to a pedicled, chimeric gastrocnemius musculocutaneous-medial sural artery perforator (GM-MSAP) or lateral sural artery perforator (GM-LSAP) flap for knee coverage in total knee arthroplasty (TKA) recurrent infections and oncological or traumatic defects of the upper leg from 2018 to 2021. Outcomes evaluated were the successful soft tissue reconstruction and flap complications. Surgical timing, reconstruction planning, technique, and rehabilitation protocols were discussed. Results Twenty-one patients were included in the study. Nineteen GM-MSAPs and 2 GM-LSAPs were performed (soft tissue reconstruction in infected TKA [12], in infected hardware [4], and in oncological patients [5]). Donor site was closed primarily in 9 cases, whereas a skin graft was required in 12. Flap wound dehiscence (1), distal flap necrosis (1), distal necrosis of the skin paddle (1), and donor site infection (1) were the encountered complications. Flap reraise associated to implant exchange or extensive debridement was successful without requiring any further flap surgery. Conclusion The propeller-perforator GM-MSAP offers qualitative defect coverage and easiness of multiple flap reraise due to skin availability and its laxity.

Dual Plate Fixation for Periprosthetic Femur Fracture after Total Knee Arthroplasty (슬관절 전치환술 후 발생한 대퇴골 삽입물 주위 골절의 이중 금속판 고정술)

  • Kim, Dong Hwi;Cha, Dong Hyuk;Ko, Kang Yeol
    • Journal of the Korean Orthopaedic Association
    • /
    • v.56 no.1
    • /
    • pp.26-33
    • /
    • 2021
  • Purpose: This study evaluated the results of dual plate fixation for periprosthetic femur fracture after total knee arthroplasty (TKA). Materials and Methods: From October 2007 to February 2013, 23 cases of periprosthetic femur fracture after TKA were treated at the author's hospital. There were 13 cases of fixation using a medial and lateral dual plate when the stability of the fracture site could not be achieved by one side fixation with a follow-up of more than one year. The cases included no loosening of the femoral component in fractures that were categorized as Lewis-Rorabeck classification II and supracondylar comminuted fractures and elongation of the fracture line to the lateral epicondyle of the femur or stem in the medullary canal. The mean age was 72 years (65-82 years), and 11 cases were female. Three cases had a stem due to revision. The mean bone marrow density was -3.2 (-1.7 to -4.4), and the mean period from primary TKA to periprosthetic fractures was 28 months (1-108 months). The mean follow-up period was 23 months (12-65 months). The medial fracture site was first exposed via the subvastus approach. Second, the supplementary plate was fixed on the lateral side of the fracture using a minimally invasive plate osteosynthesis technique. The average union time, complications, and Hospital for Special Surgery Knee Score (HSS) at the last follow-up were evaluated. Results: The mean union time was 17.4 weeks (7-40 weeks). Two cases showed delayed bone union and nonunion occurred in one case, in whom bone union was achieved three months later after re-fixation using a dual plate with an autogenous bone graft. The mean varusvalgus angulation was 1.67 degrees (-1.2-4.9 degrees), and the mean anterior-posterior angulation was 2.86 degrees (0-4.9 degrees) at the last follow-up. The mean knee range of motion was 90 degrees, and the HSS score was 85 points (70-95 points) at the last follow-up. Conclusion: Dual plate fixation for periprosthetic femur fractures that had not achieved stability by one side plate fixation after TKA showed a good clinical result that allowed early rehabilitation.

Strength Evaluation of Sin91e-Radius Total Knee Replacement (TKR) (인공무릎관절의 단축법위 회전시 근력정가)

  • Wan, Jin-Young;Sub, Kwak-Yi
    • Journal of Life Science
    • /
    • v.14 no.3
    • /
    • pp.484-489
    • /
    • 2004
  • Artificial joint replacement is one of the major surgical advances of the 21th century. The primary purpose of a TKA (Total Knee Arthroplasty) is to restore normal knee Auction. Therefore, ideally, a TKA should: (a) maintain the natural leverage of the knee joint muscles to ensure generating adequate knee muscle moments to accomplish daily tasks such as rising from a chair or climbing stairs;(b) allow the same range of motion as an complete knee; and (c) provide adequate knee joint stability. Four individuals (2 peoples after surgery one year and 2 peoples after surgery three years) participated in this study. All they were prescreened for health and functional status by the same surgeon who performed the operations. Two days of accommodation practice occurred prior to the actual strength testing. The isometric strength (KIN-COM III) of the quadriceps and hamstring were measured at 60$^\circ$ and 30$^\circ$ of knee flexion, respectively. During isokinetic concentric testing, the range of motion was between 10$^\circ$ to 80$^\circ$ of knee flexion (stand-to-sit) and extension (sit-to-stand). for a given test, the trial exhibiting maximum torque was analyzed. A 16-channel MYOPACTM EMG system (Run Technologies, Inc.) was used to collect the differential input surface electromyographic (EMG) signals of the vastus medialis (VM), vastus lateralis(VL), rectus femoris (RF) during sit-to-stand and stand-to-sit tests. Disposable electrodes (Blue SensorTM, Medicotest, Inc.) were used to collect the EMG signals. The results were as follows; 1. Less maximum concentric (16% and 21% less for 1 yew man and 3 years mm, respectively) and isometric (12% and 29%, respectively) quadriceps torque for both participants. 2.14% less maximum hamstrings concentric torque for 1 year man but 16% greater torque for 3 years mm. However, 1 year man had similar hamstring isometric peak torque for both knees. 3. Less quadriceps co-contraction by 1 year man except for the VM at 10$^\circ$-20$^\circ$ and 30$^\circ$-50$^\circ$ range of knee flexion.

Clinical Result of a Staged Reimplantation of Fungus Related Periprosthetic Joint Infection after Total Knee Arthroplasty (슬관절 전치환술 후 인공관절 주위 진균 감염의 임상적 결과)

  • Kim, Hyung Joo;Bae, Ki Cheor;Min, Kyung Keun;Choi, Hyeong Uk
    • Journal of the Korean Orthopaedic Association
    • /
    • v.54 no.1
    • /
    • pp.52-58
    • /
    • 2019
  • Purpose: Fungal periprosthetic joint infection (PJI) is a rare but devastating complication following total knee arthroplasty (TKA). On the other hand, a standardized procedure regarding an accurate treatment of this serious complication of knee arthroplasty is lacking. The clinical progress of staged reimplantation in patients who had fungus-related PJI after TKA was reviewed retrospectively. Materials and Methods: Ten patients who had a fungal related PJI after TKA between 2006 and 2017 using staged reimplantation surgery were reviewed. These patients were compared with 119 patients who had a PJI in the same period. The failure rate of infection control, intravenous antimicrobial using the period, and the clinical results were evaluated by comparing the range of motion and Korean knee score (KKS) between pre-staged reimplantation and the last follow-up. Results: In the fungal infection group, 7 out of 10 cases (70.0%) had failed in infection control using staged reimplantation and in the non-fungal group, 7 out of 119 cases (5.9%) had failed (p=0.04). In the non-fungal group, the mean duration of antibiotics was 6.2 weeks. In the fungus group, the mean duration of antibiotics was 15.3 weeks, which was 9.1 weeks longer (p<0.001). The range of motion of the knee was increased in the two groups (p=0.265). At the last follow-up, the KKS was 71.01 points in the non-fungal group and 61.3 points in the fungal group (p=0.012). Erythrocyte sedimentation rate and C-reactive protein (CRP) decreased in the two groups, but the CRP was significantly different in the two groups (p=0.007). Conclusion: The treatment of fungus-related PJIs using staged reimplantation showed uneven clinical progress and unsatisfactory clinical improvements compared to non-fungal PJI. Therefore, it is necessary to consider the use of an antifungal mixed cement spacer at resection arthroplasty and oral antifungal agent after reimplantation.

The effects of aroma inhalation on pain, anxiety, and heart rate variability among elderly women with total knee arthroplasty during continuous passive motion exercise (향 흡입법이 슬관절 전치환술 여성노인 환자의 수동적 관절운동 시 통증, 불안 및 심박변이도에 미치는 효과)

  • Park, So Young;Kim, Tae Im
    • Journal of the Korean Data and Information Science Society
    • /
    • v.28 no.6
    • /
    • pp.1383-1402
    • /
    • 2017
  • This study aims to investigate the effects of aroma inhalation on pain, anxiety, and heart rate variability of elderly women with total knee arthroplasty (TKA) during continuous passive motion (CPM) exercise. Equivalent control group pretest-posttest design was used. Participants were randomized to intervention group (n=26) or control group (n=27). Participants inhaled aroma or distilled water for 5 minutes before CPM exercise and for 40 minutes during CPM exercise on 3 consecutive days. Pain NRS, number of painkiller used, anxiety NRS, blood pressure, and heart rate variability (HRV) were measured before and after intervention. Pain NRS, anxiety NRS, blood pressure in experimental group were significantly lower than those of control group. All indices of HRV were significantly different between the two groups. Based on these results, it can be concluded that aroma inhalation was effective in decreasing pain and anxiety and changing HRV among elderly women with TKA during CPM exercise.