• Title/Summary/Keyword: TGA analysis

Search Result 1,010, Processing Time 0.031 seconds

Chemical synthesis of processable conducting polyaniline derivative with free amine functional groups

  • Kar, Pradip
    • Advances in materials Research
    • /
    • v.3 no.2
    • /
    • pp.117-128
    • /
    • 2014
  • Processable conducting polyaniline derivative with free amine functional groups was successfully synthesized from the monomer o-phenylenediamine in aqueous hydrochloric acid medium using ammonium persulfate as an oxidative initiator. The synthesized poly(o-phenylenediamine) (PoPD) in critical condition was found to be completely soluble in common organic solvents like dimethyl sulfoxide, N,N-dimethyl formamide etc. From the intrinsic viscosity measurement, the optimum condition for the polymerization was established. The polymer was characterized by ultraviolet visible spectroscopy, Fourier transform infrared spectroscopy, proton magnetic resonance spectroscopy ($^1HNMR$) and thermogravimetric (TGA) analyses. The weight average molecular weights of the synthesized polymers were determined by the dynamic light scattering (DLS) method. From the spectroscopic analysis the structure was found to resemble that of polyaniline derivative with free amine functional groups attached to ortho/meta position in the phenyl ring. However, very little ladder unit was also present with in the polymer chain. The moderate thermal stability of the synthesized polymer could be found from the TGA analysis. The average DC conductivity of $2.8{\times}10^{-4}S/cm$ was observed for the synthesized polymer pellet after doping with hydrochloric acid.

Studies on thermal and swelling properties of Poly (NIPAM-co-2-HEA) based hydrogels

  • Shekhar, Suman;Mukherjee, M.;Sen, Akhil Kumar
    • Advances in materials Research
    • /
    • v.1 no.4
    • /
    • pp.269-284
    • /
    • 2012
  • Thermoresponsive hydrogels based on N-Isopropylacrylamide (NIPAM) and 2-Hydroxyethylacrylate (HEA) were prepared by free radical polymerization. The hydrogels were characterized by elemental (CHN) analysis, differential scanning calorimetry (DSC) and thermo gravimetric analysis (TGA). DSC thermogram showed two endothermic transitions which are due to hydration of water present in different environments. One near $0^{\circ}C$ called melting transition of ice and was used to calculate the quantitative determination of the amounts of freezing and non freezing water. The other transition above the ambient temperature was due to the combination of hydrophobic hydration and hydrophilic hydration which changes with the copolymer compositions. Swelling and deswelling studies of the hydrogels were carried out using the aqueous media, salt and urea solutions. The experimental results from swelling studies revealed that copolymers have lower rates of swelling and deswelling than the homopolymer.

A Study on the Firing Reaction and Calcination Characteristics of Waste Shellfish (폐 패각류의 소성 및 하소 특성에 관한 연구)

  • Yoon, Cheol-Hun
    • Journal of the Korean Applied Science and Technology
    • /
    • v.21 no.4
    • /
    • pp.352-358
    • /
    • 2004
  • The firing reaction and calcination characteristics of the waste shellfish were examined for the future use as absorbent. The weight variation was measured according to thermal-decomposition using TGA and observed variation of the phase. The qualitative and quantitative analysis of the sample were performed using XRD and the structural analysis, SEM. The results of TGA and XRD experiments showed that the almost all of the raw Corbicula Japonica and Ostrea virginjca were changed from calcite to lime by firing and calcination reaction. The result of SEM experiment showed that the plate type of the raw sample was changed to circle type, so the surface area ratio was increased. Above results suggested that waste shellfish were usable as absorbent in the viewpoint of the reuse of resource and the decrease of environmental pollution.

Thermal Characteristics Analysis of Pre-Treated Rayon Fibers for Preparing Activated Carbon Fibers (활성탄소섬유 제조시 전처리된 레이온 섬유의 열특성 분석)

  • Choi, Sang Seun;Lee, Soon Hong
    • Journal of the Korean Society of Safety
    • /
    • v.29 no.4
    • /
    • pp.61-72
    • /
    • 2014
  • The aim of this study is to define the condition of optimal pre-treatment for preferable activated carbon fibers (ACFs), which are based on rayon fibers. This paper shows the ideal path of ACFs preparation process; implies that rayon fibers are pre-treated by various solvents with different times before the heating process. The pre-treated rayon fibers finally turned into desirable rayon fiber-based ACFs through optimal pre-treatment condition by heating processes. The thermal analysis method of pre-treated rayon fibers by thermo-gravimetry analyser (TGA) is an idealized tool, which analyzes the best thermal condition of pre-treatment process. Surface morphologies of resulting rayon fibers based ACFs were examined by scanning electron microscope(SEM). The results of TGA and SEM analyses show that the optimal pre-treatment condition for preparing ACFs was clearly defined, in terms of thermal stability and surface morphology.

A Study on the Sulfonation of Persimmon Tannin (감타닌의 술폰화에 관한 연구)

  • Kwon, Seul Gi;Bae, Do Gyu
    • Textile Coloration and Finishing
    • /
    • v.29 no.2
    • /
    • pp.69-76
    • /
    • 2017
  • To get the proper treatment conditions, sulfonation reactions of persimmon tannin with sodium sulfite and sulfuric acid were proceeded in various settings, respectively. Also, the property changes were investigated by carrying out the additional analysis: elementary analysis and instrumental analysis using FT-IR, DSC, and TGA. The degree of $-SO_3Na$ substitutions appeared 0.216 and 0.208 under the treatment time of 3 hours and 6 hours, respectively and the degree of $-SO_3H$ substitutions indicated 0.200 and 0.167 under 9 hours and 18 hours, respectively by elemental analysis. In terms of the FT-IR spectras, there was a peak based on the bonds of pyran ring and ether in relation to non-treated and sulphonated tannin at $1,102cm^{-1}$. No peak was shown in the sulfited tannin. An absorption peak which was due to the $C{\rightarrow}O$ of secondary -OH group became evident in nontreated and sulfited tannin at $1,092cm^{-1}$ and $1,090cm^{-1}$, respectively but the same result was not found in sulphonated tannin. The results of TGA analysis of the sulfonated persimmon tannin showed that the sulfonation of it improved thermal properties.

Combustion Characteristics and Thermal Properties for Wood Flour-High Density Polyethylene Composites (목분-고밀도폴리에틸렌 복합체의 연소성 및 열적특성)

  • Shin, Baeg-Woo;Chung, Kook-Sam
    • Fire Science and Engineering
    • /
    • v.26 no.1
    • /
    • pp.89-95
    • /
    • 2012
  • In this study, we were manufactured wood flour-HDPE composites by modular co-rotating twin screw extruder with L/D ratio of 42. We was measured cone calorimeter test and thermogravimetric analysis (TGA) to find the combustion characteristics and thermal properties for wood flour-HDPE composites. We then evaluated the effect of three additive-type flame retardants on fire resistance performance. The cone calorimeter test showed that the heat release rate (HRR) of untreated composites was the highest Peak HRR ($446.6kW/m^2$) as well as Mean HRR ($185.5kW/m^2$). From the TGA, it was shown that composites added flame retardants began early thermal decomposition and improved thermal stability.

Effect of enzyme treatment on the DSC and TGA behavior of silkworm powder

  • Jo, You-Young;Bae, Sung Min;Kim, HyunBok;Lee, Kwang Gill;Kweon, HaeYong
    • International Journal of Industrial Entomology and Biomaterials
    • /
    • v.37 no.1
    • /
    • pp.29-32
    • /
    • 2018
  • Silkworm powder's thermal property is an important factor for its storage and marketing. This study examined the effect of edible enzyme on the thermal property of silkworm powder using Thermogravimetric Analysis (TGA) and Differential Scanning Calorimetry (DSC). Results of the TGA showed that regardless of the enzyme treatment, the weight loss patterns of silkworm powders exhibited 3 step thermal property deterioration at approximately $80^{\circ}C$, $280^{\circ}C$, and $480^{\circ}C$ due to water evaporation and thermal degradation. This is similar with the DSC which also resulted in all samples two endothermic peaks attributed also to water evaporation and thermal degradation. These results indicated that the use of enzyme such as protease and cellulase might not affect significantly the thermal properties of silkworm powder.

Mechanical and Thermal Properties of Hydroxypropyl Cellulose/TEMPO-oxidized Cellulose Nanofibril Composite Films (Hydroxypropyl cellulose/TEMPO-산화 처리된 셀룰로오스 나노섬유를 이용한 복합필름의 기계적 및 열적 특성)

  • Jo, Yu-Jeong;Cho, Hye-Jung;Chun, Sang-Jin;Lee, Sun-Young
    • Journal of the Korean Wood Science and Technology
    • /
    • v.43 no.6
    • /
    • pp.740-745
    • /
    • 2015
  • Hydroxypropyl cellulose (HPC) composite films filled with TEMPO-oxidized cellulose nanofibrils (TOCN) were prepared in this study. In order to investigate mechanical and thermal properties of HPC/TOCN composite films, tensile strength and thermogravimetric analysis (TGA) wer performed. As the loading level of TOCN increased, the tensile strength and modulus increased significantly. However, thermal stability of HPC/TOCN composite films was not related to the loading levels of the TOCN.

Analysis of Partial Discharge in High Voltage Motor Model Coils (고압전동기 모델 코일에서 부분방전 분석)

  • Kim, Hee-Dong
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.55 no.4
    • /
    • pp.178-182
    • /
    • 2006
  • Five model coils of 6.6 kV motor were manufactured with several defects. These stator coils have artificial defects such as void of groundwall insulation, removal of semi-conductive coating and damage of strand insulation. Epoxy-mica coupler(80 pF) was connected to five model coil terminals. The voltage applied to the coils was 3.81 kV, 4.76 kV, 6.0 kV and 6.6 kV, respectively. Partial discharge(PD) tests performed in the laboratory and shield room. Digital PD detector(PDD) and turbine generator analyzer(TGA) were used to measure PD activity. TGA summarizes each plot with two quantities such as the normalized quantity number(NQN) and the peak PD magnitude(Qm). The PD levels in pC were measured with PDD. PD patterns of model coils were indicated the internal and slot discharges. PD patterns are consistent with the result of measurement using PDD and TGA instruments. AC breakdown test was performed on five model coils in order to confirm the result of PD measurements. All the failures were located in a line-end coil at the exit from the core slot.