• Title/Summary/Keyword: TEST-1

Search Result 60,001, Processing Time 0.066 seconds

Comparison of Shear Strengths of Crushed Rock Determined by Large Triaxial Test and Direct Shear Test (대형삼축압축시험 및 대형직접전단시험에 의한 사석재료의 전단강도 평가)

  • 신동훈;안태봉;이경필;이한출
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2002.10a
    • /
    • pp.259-264
    • /
    • 2002
  • In this study the shear strengths of a poorly grad ed rock material(d/sub max/≤50.8mm, C/sub u/=1.86) were determined by large direct shear test and large triaxial test. The obtained stress-strain curves by the above large shear tests for the rock materials are similar to the loose sand's or normally consolidated clay's curve, in which the peak strength does not appear obviously. And for the uniformly graded rock material the shear strength by large direct shear test may be overestimated around 1.54∼1.70 times that of large triaxial test.

  • PDF

Seismic Test of a 1/2 Scale Model of Wood House with Tiled Roof (기와집 1/2 축소 모델의 지진 실험)

  • Ryu, Hyeuk;Kim, Jae-Kwan;Jeon, Bong-Hee;Kim, Byung-Hyun
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2003.03a
    • /
    • pp.362-367
    • /
    • 2003
  • To improve the reliability of seismic hazard assessment of historic earthquake, shaking table test of a 1/2 scale model of wood house with tiled roof was performed. Scaled model was constructed through rigorous verification process to have quantitative relationship between the intensity of earthquake and damage state. The completed model was mounted on a shaking table and subjected to the dynamic tests. Two kinds of tests were performed: exploratory test and fragility test. The exploratory test was done with low intensity shaking. In the fragility test, the behavior of the model was carefully monitored while increasing the shaking intensity. The construction details of the model are provided and test procedures are reported. Finally important test results are presented and their implications are discussed.

  • PDF

Seismic Test of a 1/2 Scale Model of Wood House with Thatched Roof (초가집 1/2 축소 모델의 지진 실험)

  • Ryu, Hyeuk;Kim, Jae-Kwan;Huh, Young-Chul;Jeon, Bong-Hee
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2003.09a
    • /
    • pp.247-252
    • /
    • 2003
  • To improve the reliability of seismic hazard assessment of historic earthquake, shaking table test of a 1/2 scale model of wood house with thatched roof was peformed. Scaled model was constructed through rigorous verification process to have quantitative relationship between the intensity of earthquake and damage state. The completed model was mounted on a shaking table and subjected to the dynamic tests. Two kinds of tests were performed: exploratory test and fragility test. The exploratory test was done with low intensity shaking. In the fragility test, the behavior of the model was carefully monitored while increasing the shaking intensity. The construction details of the model are provided and test procedures are reported. Finally important test results are presented and their implications are discussed.

  • PDF

Analysis of the Actual Condition of the Tree Doctor Qualification Test and Improvement of the System - Focus on the First Test - (나무의사 자격시험의 실태분석과 제도개선 방안 - 제1차 시험을 중심으로 -)

  • Yong Jo Jung;Hak Cheol Kim
    • Journal of Environmental Science International
    • /
    • v.32 no.1
    • /
    • pp.11-24
    • /
    • 2023
  • This study aimed to provide preliminary data for the improvement of the tree doctor qualification test (first written test), which was newly created by enforcing the Forest Protection Act on June 28, 2018., The high demand for system improvement accelerated this study. The results were analyzeds through literature and questionnaire surveys. Writing test questions and the license of the tree doctor qualification exam are currently managed by the Korea Forestry Research Institute, and it is deemed that the test should be entrusted to Human Resources Development Service of Korea for fair and transparent management. Additionally, the plan for the improvement of the subject-wise scope of examination questions writing, difficulty of test questions, and acceptance rate of the first test should be prepared after public hearings or seminars related to the examination questions.

Test-bed Design for the Evaluation of Wireless Communication System on Small Launch Vehicle (소형 발사체 무선 통신시스템 검증을 위한 테스트 베드 설계)

  • Lee, Dae-Hyun;Oh, TaeckKeun;Park, Dong-Hwa;Lee, Hong-Ki;Park, Dong-Hyun;Song, Ho-Jin
    • Journal of Advanced Navigation Technology
    • /
    • v.22 no.4
    • /
    • pp.311-318
    • /
    • 2018
  • In this paper, test-bed for the evaluation of wireless communication system on a small launch vehicle is proposed. The proposed test-bed consists of antenna test-coupler, RF attenuators, and RF switch modules. The antenna test-coupler isolates antennas for each band and transmits / receives wireless signals. The RF attenuator and switch are used for path selection of testing signal path. In design and measurement result of the antenna test-coupler, the antenna test-coupler has shielding effect higher than 39.3, 47.1, 56.1 dB at UHF-, S-, X-band. Through testing on small launch vehicle wireless communication system, we were able to successfully transmit and receive data between each test system and launch vehicle with antenna path switching.

A Study on Double - Punch Test for Tensile Strength of Concrete (Double-Punch Test에 의한 콘크리트의 인장강도 시험에 관한 연구)

  • 이우종;고재군
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.30 no.2
    • /
    • pp.82-94
    • /
    • 1988
  • The purpose of this study is to introduce the Double Punch test method which is an indirect testing method of tensile strength of concrete, and to compare with the tensile strength of concrete as determined by the split-cylinder test, a practical method for performing the Double Punch test to obtain the tensile strength of concrete is proposed and recommended for general use. In this study, the dimensions of cylindrical specimens used in the Double-Punch test were 15X30cm, 15X15cm, 10${\times}$(20cm, and 5${\times}$l0cm, and in the split-cylinder test were 15${\times}$(30cm, 15${\times}$(15cm, and 10${\times}$(20cm. And the diameters of loading punches used in the Double-Punch test were 1.5cm, 2.5cm, and 3.5 cm. The results obtained from tests are summarized as follows ; 1. In the split-cylinder test, the tensile strength of concrete by the linear elasticity theory is similar to that of plasticity theory. 2. Both split-cylinder test and Double-Punch test, tensile strength of concrete is increased with decreasing specimen size. This tendency is identical when the ratio of specimen diameter to height is 1: 2, but that tendency is quite different when the ratio is 1: 3. In the Double-Punch test, if specimen size is constant, by increasing the punch size, tensile strength of concrete is increased, too. 4. Using a 15 ${\times}$( 15 cm cylinder specimen and 3.5 cm diameter punch in the Double Punch test would give the most uniform and consistent result in tensile strength, and the result showed a gQod correlation with splitting tensile strength from 15 x 30cm specimen. 5. In order to obtain satisfactory results and to nuninuze variability, it is proposed that specimens of 15 cm in diameter and 15 cm in height with two 3.5 cm diameter punches should be used. It seems, therefore, reasonable tt) take f't=0.0024 P(kg / cm$^2$) as a working formula for computing the tensile strength in the Double Punch test for concrete.

  • PDF

Utility Evaluation of Two-point Calibration Curve applied for TSH, FT4 Tests (TSH, FT4 검사의 Two-point Calibration Curve 적용의 유용성 평가)

  • Park, Hye-Mi;Yoo, Seon-Hee;Lee, Seon-Ho;Kim, Nyun-Ok
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.20 no.2
    • /
    • pp.75-79
    • /
    • 2016
  • Purpose The ASAN Medical Center, Nuclear Medicine performs TSH (Thyroid stimulating hormone) and FT4 (Free Thyroxine) tests 8 times per day. Accordingly, 70 ~ 80 kit tubes are consumed every day for the measurements and the time consumed for reagent dispensing averages over 170 seconds, where the TAT (turnaround time) may be effected when the number of test samples is larger than expected. Therefore, the following test was conducted with the purpose to reduce the number of kit tubes consumed, and reduce the time for reagent dispensing. Materials and Methods The test is based on applying the same reagent for tests where the number of samples is 30 or less. The test for TSH was conducted 9 times from July $1^{st}$ 2015 to July $10^{th}$ 2015. The test for FT4 was conducted 4 times from June $18^{th}$ 2015 to June $22^{nd}$, 2015. Standard Solution No.2 (0.153 uU/mL) and No.5 (4.96 uU/mL) was selected as the two-point standards for the TSH test, and Standard Solution No.3 (0.777 ng/dL) and No.4 (2.044 ng/dL) was selected as the two-point standards for the FT4 test. 38 test samples were subject to correlation analysis. Results For TSH, the result of the normal test shows ranges of 0.20 ~ 0.37 uU/mL for Control1, 0.53 ~ 0.71 uU/mL for Control2, and 6.77 ~ 7.94uU/mL for Control3, while the result of two-point calibration curve test shows ranges of 0.18 ~ 0.27 uU/mL for Control1, 0.53 ~ 0.71 uU/mL for Control2, and 7.30 ~ 8.52 uU/mL for Control3. For FT4, the result of the normal test shows ranges of 0.85 ~ 0.94 ng/dL for Control1 and 4.23 ~ 4.57 ng/dL for Control2, while the result of two-point calibration curve test shows ranges of 0.61 ~ 0.75 ng/dL for Control1 and 3.88 ~ 5.71 ng/dL for Control2. For TSH, the CV% of the normal test for Control1, Control2 and Control3 are 10.5, 3.3 and 3.6 respectively, while the CV% of the two-point calibration curve test for Control1 and Control1 are 12.4, 8.2 and 5.1 respectively. The result shows an outstanding correlation of TSH: y = 0.9985x - 0.0459 $R^2=0.9986$. For FT4, the CV% of the normal test for Control1 and Control2 are 0.70 and 0.71 respectively, while the CV% of the two-point calibration curve test for Control1 and Control1 are 8.7 and 16.2 respectively. The result shows an outstanding correlation of FT4: y = 1.2674x - 0.1133 $R^2=0.9824$. Conclusion The two-point calibration curve can be efficiently applied for TSH in cases where the number of test samples is not large, since the number of samples to be re-tested increases when the result is abnormal from the calibration curve. The two-point calibration curve test should not be applied for FT4 where the results do not consistently comply with the quality assessment range. Depending on how the two-point calibration curve is applied, up to 5 test tubes can be conserved per test, and the reduced time for reagent dispensing is anticipated to have a positive effect on the TAT (turnaround time).

  • PDF

Development for Java/RTI Test Suite (Java/RTI를 위한 Test Suite 개발)

  • 이정욱;김용주;김영찬
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2003.05a
    • /
    • pp.749-752
    • /
    • 2003
  • The HLA is defined by three components: (1) Rules, (2) the HLA Interface Specification, and (3) the Object Model Template(OMT). The RTI(Run-Time Infrastructure) software implements the interface specification. It provides services in a manner that is comparable to the way a distributed operating system provides services to applications. A way to test whether is suitable for a standard, and all service was implemented is tested through two phases of processes to verify the RTI which proposed in DMSO. In this paper, we discuss Level One Test Procedures and a method. Confirms whether RTI was implemented in Interface Specification according to Level One Test Procedures appropriately through a test. Develops Test Suite for every each step to test whether a correct command and the expected results are occur.

  • PDF

Numerical simulation of tensile failure of concrete using Particle Flow Code (PFC)

  • Haeri, Hadi;Sarfarazi, Vahab
    • Computers and Concrete
    • /
    • v.18 no.1
    • /
    • pp.39-51
    • /
    • 2016
  • This paper considers the tensile strength of concrete samples in direct, CTT, modified tension, splitting and ring tests using both of the experimental tests and numerical simulation (particle flow code 2D). It determined that which one of indirect tensile strength is close to direct tensile strength. Initially calibration of PFC was undertaken with respect to the data obtained from Brazilian laboratory tests to ensure the conformity of the simulated numerical models response. Furthermore, validation of the simulated models in four introduced tests was also cross checked with the results from experimental tests. By using numerical testing, the failure process was visually observed and failure patterns were watched to be reasonable in accordance with experimental results. Discrete element simulations demonstrated that the macro fractures in models are caused by microscopic tensile breakages on large numbers of bonded discs. Tensile strength of concrete in direct test was less than other tests results. Tensile strength resulted from modified tension test was close to direct test results. So modified tension test can be a proper test for determination of tensile strength of concrete in absence of direct test. Other advantages shown by modified tension tests are: (1) sample preparation is easy and (2) the use of a simple conventional compression press controlled by displacement compared with complicate device in other tests.

A Study on the Improvement of the Test Process for Defense Systems Based on Quantitative Management (정량적 관리 기반 무기체계 시험업무 프로세스 개선 연구)

  • Tae Heum Na;Joo Yeoun Lee;Young Min Kim
    • Journal of the Korean Society of Systems Engineering
    • /
    • v.20 no.spc1
    • /
    • pp.1-11
    • /
    • 2024
  • Today, the importance of test and evaluation of defense systems is increasing day by day. In performing efficient defense systems test works, process improvement based on quantitative management is essential. The purpose of this paper is to present the results of process improvement for the defense systems test works of the test organization based on quantitative management activities. As a methodology to confirm process improvement performance, the 'MPM(Managing Performance and Measurement)' practice area of the CMMI model was applied. The quantitative management model for defense systems test works was developed so that it could be practically applied not only to the entire test organization but also to the organization at the department level that actually performs the test work. Finally, the application cases of the quantitative management model for defense system test works and the results of process improvement were described.