• 제목/요약/키워드: TEST-1

검색결과 59,887건 처리시간 0.068초

대형삼축압축시험 및 대형직접전단시험에 의한 사석재료의 전단강도 평가 (Comparison of Shear Strengths of Crushed Rock Determined by Large Triaxial Test and Direct Shear Test)

  • 신동훈;안태봉;이경필;이한출
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2002년도 가을 학술발표회 논문집
    • /
    • pp.259-264
    • /
    • 2002
  • In this study the shear strengths of a poorly grad ed rock material(d/sub max/≤50.8mm, C/sub u/=1.86) were determined by large direct shear test and large triaxial test. The obtained stress-strain curves by the above large shear tests for the rock materials are similar to the loose sand's or normally consolidated clay's curve, in which the peak strength does not appear obviously. And for the uniformly graded rock material the shear strength by large direct shear test may be overestimated around 1.54∼1.70 times that of large triaxial test.

  • PDF

기와집 1/2 축소 모델의 지진 실험 (Seismic Test of a 1/2 Scale Model of Wood House with Tiled Roof)

  • 류혁;김재관;전봉희;김병현
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2003년도 춘계 학술발표회논문집
    • /
    • pp.362-367
    • /
    • 2003
  • To improve the reliability of seismic hazard assessment of historic earthquake, shaking table test of a 1/2 scale model of wood house with tiled roof was performed. Scaled model was constructed through rigorous verification process to have quantitative relationship between the intensity of earthquake and damage state. The completed model was mounted on a shaking table and subjected to the dynamic tests. Two kinds of tests were performed: exploratory test and fragility test. The exploratory test was done with low intensity shaking. In the fragility test, the behavior of the model was carefully monitored while increasing the shaking intensity. The construction details of the model are provided and test procedures are reported. Finally important test results are presented and their implications are discussed.

  • PDF

초가집 1/2 축소 모델의 지진 실험 (Seismic Test of a 1/2 Scale Model of Wood House with Thatched Roof)

  • 류혁;김재관;허영철;전봉희
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2003년도 추계 학술발표회논문집
    • /
    • pp.247-252
    • /
    • 2003
  • To improve the reliability of seismic hazard assessment of historic earthquake, shaking table test of a 1/2 scale model of wood house with thatched roof was peformed. Scaled model was constructed through rigorous verification process to have quantitative relationship between the intensity of earthquake and damage state. The completed model was mounted on a shaking table and subjected to the dynamic tests. Two kinds of tests were performed: exploratory test and fragility test. The exploratory test was done with low intensity shaking. In the fragility test, the behavior of the model was carefully monitored while increasing the shaking intensity. The construction details of the model are provided and test procedures are reported. Finally important test results are presented and their implications are discussed.

  • PDF

나무의사 자격시험의 실태분석과 제도개선 방안 - 제1차 시험을 중심으로 - (Analysis of the Actual Condition of the Tree Doctor Qualification Test and Improvement of the System - Focus on the First Test -)

  • 정용조;김학철
    • 한국환경과학회지
    • /
    • 제32권1호
    • /
    • pp.11-24
    • /
    • 2023
  • This study aimed to provide preliminary data for the improvement of the tree doctor qualification test (first written test), which was newly created by enforcing the Forest Protection Act on June 28, 2018., The high demand for system improvement accelerated this study. The results were analyzeds through literature and questionnaire surveys. Writing test questions and the license of the tree doctor qualification exam are currently managed by the Korea Forestry Research Institute, and it is deemed that the test should be entrusted to Human Resources Development Service of Korea for fair and transparent management. Additionally, the plan for the improvement of the subject-wise scope of examination questions writing, difficulty of test questions, and acceptance rate of the first test should be prepared after public hearings or seminars related to the examination questions.

소형 발사체 무선 통신시스템 검증을 위한 테스트 베드 설계 (Test-bed Design for the Evaluation of Wireless Communication System on Small Launch Vehicle)

  • 이대현;오택근;박동화;이홍기;박동현;송호진
    • 한국항행학회논문지
    • /
    • 제22권4호
    • /
    • pp.311-318
    • /
    • 2018
  • 본 논문에서는 소형발사체의 무선통신 시스템 검증을 위한 테스트 베드를 제안한다. 제안하는 테스트 베드는 안테나 테스트 커플러와 RF 감쇄기 및 스위칭 시스템으로 구성되어 있다. 안테나 테스트 커플러는 소형 발사체에 장착되어 있는 각 대역별 안테나를 서로 격리 시키며 무선신호를 송/수신하기 위한 장치이며 RF 감쇄기 및 스위칭 시스템은 각 대역의 안테나별 통신점검을 위하여 안테나별 경로를 선택해 주는 장치이다. 안테나 테스트 커플러 설계 결과, UHF-, S-, X-대역에서 39.3, 47.1, 56.1 dB 이상의 차폐율을 확인 할 수 있었다. 실제 소형 발사체에 적용하여 발사체 통신 시스템을 점검한 결과, 정상적으로 데이터 송/수신을 확인 할 수 있었으며, 안테나 경로 스위칭을 통하여 각 대역의 안테나별 통신 점검을 수행할 수 있었다.

Double-Punch Test에 의한 콘크리트의 인장강도 시험에 관한 연구 (A Study on Double - Punch Test for Tensile Strength of Concrete)

  • 이우종;고재군
    • 한국농공학회지
    • /
    • 제30권2호
    • /
    • pp.82-94
    • /
    • 1988
  • The purpose of this study is to introduce the Double Punch test method which is an indirect testing method of tensile strength of concrete, and to compare with the tensile strength of concrete as determined by the split-cylinder test, a practical method for performing the Double Punch test to obtain the tensile strength of concrete is proposed and recommended for general use. In this study, the dimensions of cylindrical specimens used in the Double-Punch test were 15X30cm, 15X15cm, 10${\times}$(20cm, and 5${\times}$l0cm, and in the split-cylinder test were 15${\times}$(30cm, 15${\times}$(15cm, and 10${\times}$(20cm. And the diameters of loading punches used in the Double-Punch test were 1.5cm, 2.5cm, and 3.5 cm. The results obtained from tests are summarized as follows ; 1. In the split-cylinder test, the tensile strength of concrete by the linear elasticity theory is similar to that of plasticity theory. 2. Both split-cylinder test and Double-Punch test, tensile strength of concrete is increased with decreasing specimen size. This tendency is identical when the ratio of specimen diameter to height is 1: 2, but that tendency is quite different when the ratio is 1: 3. In the Double-Punch test, if specimen size is constant, by increasing the punch size, tensile strength of concrete is increased, too. 4. Using a 15 ${\times}$( 15 cm cylinder specimen and 3.5 cm diameter punch in the Double Punch test would give the most uniform and consistent result in tensile strength, and the result showed a gQod correlation with splitting tensile strength from 15 x 30cm specimen. 5. In order to obtain satisfactory results and to nuninuze variability, it is proposed that specimens of 15 cm in diameter and 15 cm in height with two 3.5 cm diameter punches should be used. It seems, therefore, reasonable tt) take f't=0.0024 P(kg / cm$^2$) as a working formula for computing the tensile strength in the Double Punch test for concrete.

  • PDF

TSH, FT4 검사의 Two-point Calibration Curve 적용의 유용성 평가 (Utility Evaluation of Two-point Calibration Curve applied for TSH, FT4 Tests)

  • 박혜미;유선희;이선호;김년옥
    • 핵의학기술
    • /
    • 제20권2호
    • /
    • pp.75-79
    • /
    • 2016
  • Purpose The ASAN Medical Center, Nuclear Medicine performs TSH (Thyroid stimulating hormone) and FT4 (Free Thyroxine) tests 8 times per day. Accordingly, 70 ~ 80 kit tubes are consumed every day for the measurements and the time consumed for reagent dispensing averages over 170 seconds, where the TAT (turnaround time) may be effected when the number of test samples is larger than expected. Therefore, the following test was conducted with the purpose to reduce the number of kit tubes consumed, and reduce the time for reagent dispensing. Materials and Methods The test is based on applying the same reagent for tests where the number of samples is 30 or less. The test for TSH was conducted 9 times from July $1^{st}$ 2015 to July $10^{th}$ 2015. The test for FT4 was conducted 4 times from June $18^{th}$ 2015 to June $22^{nd}$, 2015. Standard Solution No.2 (0.153 uU/mL) and No.5 (4.96 uU/mL) was selected as the two-point standards for the TSH test, and Standard Solution No.3 (0.777 ng/dL) and No.4 (2.044 ng/dL) was selected as the two-point standards for the FT4 test. 38 test samples were subject to correlation analysis. Results For TSH, the result of the normal test shows ranges of 0.20 ~ 0.37 uU/mL for Control1, 0.53 ~ 0.71 uU/mL for Control2, and 6.77 ~ 7.94uU/mL for Control3, while the result of two-point calibration curve test shows ranges of 0.18 ~ 0.27 uU/mL for Control1, 0.53 ~ 0.71 uU/mL for Control2, and 7.30 ~ 8.52 uU/mL for Control3. For FT4, the result of the normal test shows ranges of 0.85 ~ 0.94 ng/dL for Control1 and 4.23 ~ 4.57 ng/dL for Control2, while the result of two-point calibration curve test shows ranges of 0.61 ~ 0.75 ng/dL for Control1 and 3.88 ~ 5.71 ng/dL for Control2. For TSH, the CV% of the normal test for Control1, Control2 and Control3 are 10.5, 3.3 and 3.6 respectively, while the CV% of the two-point calibration curve test for Control1 and Control1 are 12.4, 8.2 and 5.1 respectively. The result shows an outstanding correlation of TSH: y = 0.9985x - 0.0459 $R^2=0.9986$. For FT4, the CV% of the normal test for Control1 and Control2 are 0.70 and 0.71 respectively, while the CV% of the two-point calibration curve test for Control1 and Control1 are 8.7 and 16.2 respectively. The result shows an outstanding correlation of FT4: y = 1.2674x - 0.1133 $R^2=0.9824$. Conclusion The two-point calibration curve can be efficiently applied for TSH in cases where the number of test samples is not large, since the number of samples to be re-tested increases when the result is abnormal from the calibration curve. The two-point calibration curve test should not be applied for FT4 where the results do not consistently comply with the quality assessment range. Depending on how the two-point calibration curve is applied, up to 5 test tubes can be conserved per test, and the reduced time for reagent dispensing is anticipated to have a positive effect on the TAT (turnaround time).

  • PDF

Java/RTI를 위한 Test Suite 개발 (Development for Java/RTI Test Suite)

  • 이정욱;김용주;김영찬
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2003년도 춘계종합학술대회
    • /
    • pp.749-752
    • /
    • 2003
  • HLA(High Level Architecture)는 미 국방성에서 제안한 분산 시뮬레이션을 위한 실시간 분산 데이터 공유를 위한 객체, 시간, 인터페이스 규격을 말한다. 이 HLA는 (1) Rules, (2) Interface Specification, (3) Object Model Template 둥의 3가지 구성요소로 정의되며, 인터페이스 명세를 구현한 것이 RTI(Run-Time Infrastructure)이다. RTI는 분산 운영체계가 응용 프로그램에게 서비스를 제공하는 것과 유사한 방법으로 Federation을 구성하고 있는 Federate들에게 상호연동에 필요한 서비스를 제공한다. 모든 서비스들이 표준에 적합하게 구현되었는지 테스트하기 위한 방법은 DMSO에서 제안한 RTI를 검증하기 위한 2단계 과정을 통해 테스트된다. 본 논문에서는 1단계 테스트를 위한 테스트 절차와 그 방법에 대해 논한다 테스트 결과를 토대로 각 영역에서 DMSO에서 제안한 Level One Test Procedures에 따라 RTI가 Interface Specification에 적합하게 구현되었는지 확인하며, 각 단계마다 올바른 명령과 예상된 결과가 나오는지 테스트하기 위한 Test Suite를 개발한다.

  • PDF

Numerical simulation of tensile failure of concrete using Particle Flow Code (PFC)

  • Haeri, Hadi;Sarfarazi, Vahab
    • Computers and Concrete
    • /
    • 제18권1호
    • /
    • pp.39-51
    • /
    • 2016
  • This paper considers the tensile strength of concrete samples in direct, CTT, modified tension, splitting and ring tests using both of the experimental tests and numerical simulation (particle flow code 2D). It determined that which one of indirect tensile strength is close to direct tensile strength. Initially calibration of PFC was undertaken with respect to the data obtained from Brazilian laboratory tests to ensure the conformity of the simulated numerical models response. Furthermore, validation of the simulated models in four introduced tests was also cross checked with the results from experimental tests. By using numerical testing, the failure process was visually observed and failure patterns were watched to be reasonable in accordance with experimental results. Discrete element simulations demonstrated that the macro fractures in models are caused by microscopic tensile breakages on large numbers of bonded discs. Tensile strength of concrete in direct test was less than other tests results. Tensile strength resulted from modified tension test was close to direct test results. So modified tension test can be a proper test for determination of tensile strength of concrete in absence of direct test. Other advantages shown by modified tension tests are: (1) sample preparation is easy and (2) the use of a simple conventional compression press controlled by displacement compared with complicate device in other tests.

정량적 관리 기반 무기체계 시험업무 프로세스 개선 연구 (A Study on the Improvement of the Test Process for Defense Systems Based on Quantitative Management)

  • 나태흠;이주연;김영민
    • 시스템엔지니어링학술지
    • /
    • 제20권spc1호
    • /
    • pp.1-11
    • /
    • 2024
  • Today, the importance of test and evaluation of defense systems is increasing day by day. In performing efficient defense systems test works, process improvement based on quantitative management is essential. The purpose of this paper is to present the results of process improvement for the defense systems test works of the test organization based on quantitative management activities. As a methodology to confirm process improvement performance, the 'MPM(Managing Performance and Measurement)' practice area of the CMMI model was applied. The quantitative management model for defense systems test works was developed so that it could be practically applied not only to the entire test organization but also to the organization at the department level that actually performs the test work. Finally, the application cases of the quantitative management model for defense system test works and the results of process improvement were described.