• Title/Summary/Keyword: TEMPERATURE

Search Result 88,815, Processing Time 0.074 seconds

An Effect of Temperature on the Fatigue Crack Propagation Behavior of Spring Steel for Vehicle (차량용 스프링강의 피로거동에 미치는 온도의 영향)

  • 박경동;류찬욱
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.12 no.1
    • /
    • pp.83-90
    • /
    • 2004
  • In this study, CT specimens were prepared from spring steel(SUP9) processed shot peening which was room temperature and low temperature experiment. And we got the following characteristics from fatigue crack growth test carried out in the environment of room temperature and low temperature at $25^{\circ}C$, $-30^{\circ}C$, $-50^{\circ}C$, $-70^{\circ}C$,$-100^{\circ}C$, and $-150^{\circ}C$, in the range of stress ratio of 0.05 by means of opening mode displacement. The threshold stress intensity factor range ΔKth in the early stage of fatigue crack growth (Region I)was increased but stress intensity factor range ΔK in the stable of fatigue crack growth (Region II) was decreased in proportion to decrease temperature. It is assumed that the fatigue resistance characteristics and fracture strength at low temperature and high temperature is considerably higher than that of room temperature in the early stage and stable of fatigue crack growth region.

Design of Temperature Stable Pulse Width Modulation Circuit Using CMOS Process Technology (CMOS 공정을 이용하는 동작온도에 무관한 펄스폭 변조회로 설계)

  • Kim, Do-Woo;Choi, Jin-Ho
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.186-187
    • /
    • 2007
  • In this work, a temperature stable PWM(Pulse width modulation) circuit is proposed. The designed PWM circuit has a temperature dependent current source and a temperature independent voltage to compensate electrical characteristics with operating temperature. The variation of driving current is from about 4% to -6% in the temperature range $0^{\circ}C\;to\;70^{\circ}C$ compared to the current at the room temperature. The variation of bandgap voltage reference is from about 1.3% to -0.2% with temperature when the supply voltage is 3.3 volts. From simulation results, the variation of output pulse width is less than from 0.86% to -0.38% in the temperature range $0^{\circ}C\;to\;70^{\circ}C$.

  • PDF

Temperature-dependence of Mechanical Properties of Die Steel STD61 (금형강 STD61의 온도에 따른 기계적 성질의 변화)

  • 여은구;이용신
    • Transactions of Materials Processing
    • /
    • v.13 no.5
    • /
    • pp.435-440
    • /
    • 2004
  • The temperature in hot forming of metallic materials, such as hot extrusion and hot forging, ranges from $300^{\circ}C$ to $900^{\circ}C$. Correspondingly, the die also exhibits high temperatures close to that of a work piece and its life is limited generally by high temperature fatigue. Thus, the analysis of high temperature fatigue would need the mechanical properties over the wide ranges of temperature. However, very few studies on the high temperature fatigue of brittle materials have been reported. Especially, the study on the fatigue behavior over such transition temperature regime is very rare. In this paper, the stress-strain curves and stress-life curves of a die steel such as STD61 are experimentally obtained. The wide ranges of temperature from $300^{\circ}C$ to $900^{\circ}C$ are considered in experiments and the transition temperature zone is carefully examined.

Climate Change Assessment on Air Temperature over Han River and Imjin River Watersheds in Korea

  • Jang, S.;Hwang, M.
    • International conference on construction engineering and project management
    • /
    • 2015.10a
    • /
    • pp.740-741
    • /
    • 2015
  • the downscaled air temperature data over study region for the projected 2001 - 2099 period were then ensemble averaged, and the ensemble averages of 6 realizations were compared against the corresponding historical downscaled data for the 1961 - 2000 period in order to assess the impact of climate change on air temperature over study region by graphical, spatial and statistical methods. In order to evaluate the seasonal trends under future climate change conditions, the simulated annual, annual DJF (December-January-February), and annual JJA (June-July-August) mean air temperature for 5 watersheds during historical and future periods were evaluated. From the results, it is clear that there is a rising trend in the projected air temperature and future air temperature would be warmer by about 3 degrees Celsius toward the end of 21st century if the ensemble projections of air temperature become true. Spatial comparison of 30-year average annual mean air temperature between historical period (1970 - 1999) and ensemble average of 6-realization shows that air temperature is warmer toward end of 21st century compared to historical period.

  • PDF

Research on Measurement of Infrared Thermograpphy under High Temperature Condition (고온 환경에서의 적외선 열화상 측정에 관한 연구)

  • Jun-Sik Lee;Jae-Wook Jeon
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.27 no.1
    • /
    • pp.57-62
    • /
    • 2024
  • This study conducted a measurement method of high temeprature conditions using infrared termography. All objects emit infrared light, and this emissivity has a significant impact on the temperature measurements of infrared thermal imaging (IR) cameras. In order to measure the temperature more accurately with the IR camera, correction equations were derived by measuring the emissivity according to the temperature change of combustible metals in a high-temperature environment. Two combustible metals, Mg and Al, were used to measure emissivity with changing temperature. Each metal was heated, the emissivity was measured by comparing the temperature with IR camera and thermocouples so that the correlation between temperature and emissivity could be anslyzed. As a result of the experiment, the emissivity of the metals increases as the temperature increased. This can be interpreted as a result of increased radiation emission as the thermal movement of internal metal molecules increased.

A Study on the Vertical Temperature Difference of Steel Box Girder Bridge by Field Measurement (실측에 의한 강박스거더교의 상하 온도차에 대한 연구)

  • Lee, Seong-Haeng;Park, Young-Chun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.8
    • /
    • pp.545-551
    • /
    • 2018
  • For domestic application of the temperature gradient model proposed by foreign design standards, a specimen of steel box girder bridge was fabricated with the following dimensions: 2.0 m width, 2.0 m height and 3.0 m length. Temperature was measured using 24 temperature gauges during the summer of 2016. The reliability of the measured data was verified by comparing the measured air temperature with the ambient air temperature of the Korea Meteorological Administration. Of the measured gauges, four temperature gauges that can be compared with the temperature difference of the Euro code were selected and used to analyze the distribution of the measured temperatures at each point. The reference atmospheric temperature for the selection of the maximum temperature difference was determined by considering the standard error. Maximum and minimum temperatures were calculated from the four selected points and the resulting temperature difference was calculated. The model for the temperature difference in the steel box girder bridge was shown by graphing the temperature difference. Compared to the temperature distribution of the Euro code, the presented temperature difference model showed a temperature difference of $0.9^{\circ}C$ at the top and of $0.3^{\circ}$ to $0.4^{\circ}C$ at the intermediate part. These results suggested that the presented model could be considered relatively similar to the Euro code The calculated standard error coefficient was 2.71 to 2.84 times the standard error and represents a range of values. The proposed temperature difference model may be used to generate basic data for calculating the temperature difference in temperature load design.

Comparison of the Thermal Environment in the Downtown Location and the Outskirt Site base on the Field Observations in the Summer (미기상 관측을 통한 하절기 도심과 외곽의 열환경 비교)

  • Jung, Im-Soo;Choi, Dong-Ho;Lee, Bu-Yong
    • Journal of the Korean Solar Energy Society
    • /
    • v.29 no.6
    • /
    • pp.94-101
    • /
    • 2009
  • This study which is the fundamental work to investigate the property of urban climate compared the property of thermal environment in the downtown location and the outskirt site based on the field observation in the summer. We analysed thermal environment in the downtown location mainly by distributional characteristics during day and night with changes and correlation analysis of the air temperature, the globe temperature and the surface temperature through the simultaneous observation of the property of thermal environment at two places in real time. The summary of finding in this study is as follows. (1)It is observed on the day chosen by sample that diurnal air temperature range in the downtown location is $22.3{\sim}34.9^{\circ}C$, and diurnal air temperature range in the Outskirt site is $20.0{\sim}34.3^{\circ}C$, so, we found that the diurnal air temperature range in the outskirt site is $1.7^{\circ}C$ higher than in the downtown location. (2)In comparison of the globe temperature after sunset, we found the change of more sudden temperature drops in the outskirt site than in the downtown location. (3)It is observed on the days chosen by sample that the average of globe temperature range is $1.1^{\circ}C$, the average of surface temperature range is $1.0^{\circ}C$, and air temperature range is $2.0^{\circ}C$, thus, the we found that the average of air temperature is $1.0^{\circ}C$ higher than globe temperature and the surface temperature. (4)After the consideration of air temperature and globe temperature distribution, the highest temperature reaching time of globe temperature is one hour earlier than air temperature in the downtown location, on the other hand, although the highest temperature reaching time of globe temperature in the outskirt sites is one hour later than in the downtown location, the timelag found in the downtown location was not found in the outskirt site.

Comparison by Measurement Sites in Temperature of Neonates : Ear-based rectal, Rectal, Axilla, Abdominal Temperature (측정부위별 신생아의 체온 비교 : 고막기준 직장체온, 직장체온, 액와체온, 복부체온)

  • 김화순;안영미
    • Journal of Korean Academy of Nursing
    • /
    • v.29 no.4
    • /
    • pp.903-916
    • /
    • 1999
  • The purpose of this study was to compare the ear-based rectal temperature measured with a tympanic thermometer with the rectal temperature measured with a glass mercury thermometer in order to test the accuracy of tympanic thermometer and to determine relationship among rectal, axilla, and abdominal temperature in neonates. The samples consisted of thirty four neonates admitted to the neonatal intensive care unit and nursery at an university affiliated hospital. The mean age of the subjects was 4.9 days. The ear-based rectal temperatures were taken with a tympanic thermometer in rectal mode (First Temp Genius 3000). Rectal and axilla temperatures were taken with a glass mercury thermometer, Abdominal temperature was continuously monitored with the probe connected to the servo controller of incubator. The results of the study can be summarized as follows : 1. Intrarater comparison : Agreement between the first and the second ear-based rectal temperature was 97% within 0.1$^{\circ}C$. 2. Comparison of ear-based rectal temperature and the rectal temperature from a glass mercury thermometer : ear-based rectal temperature ranged from 36.95$^{\circ}C$d to 37.95$^{\circ}C$, with a mean of 37.58$^{\circ}C$(SD=0.22$^{\circ}C$). Rectal temperature from a glass mercury thermometer ranged from 36.2$0^{\circ}C$ to 37.2$0^{\circ}C$, with a mean 36.75$^{\circ}C$(SD=0.29). The mean difference between both temperatures was 0.84$^{\circ}C$. The correlation coefficient between both temperatures was r=0.77(p=0.00). 3. Comparison of rectal and axilla temperature : Axilla temperature ranged from 35.8$0^{\circ}C$ to 37.1$0^{\circ}C$, with a mean of 36.55$^{\circ}C$. The mean absolute difference between the rectal and axilla temperature was 0.23$^{\circ}C$. The correlation coefficient between rectal and axilla was r=0.67. 4. Comparison of axilla and abdominal temperature : Abdominal temperature ranged from 36.2$0^{\circ}C$ to 37.0$0^{\circ}C$, with a mean of 36.58$^{\circ}C$. The mean absolute difference between axilla and abdominal temperature was only -0.03$^{\circ}C$. Findings of this study suggest that ear-based rectal temperature overestimates the actual rectal temperatures in neonates. Therefore, the interchangeble use of both temperatures in clinics seems problematic. The site offset(adjustment value) programmed in rectal mode of the tympanic thermometer needs to be readjusted. Choosing one optimal site for temperature measurement for each patient, and using the specific site consistently would result in more consistent measurements of changes in body temperature, and thus can be more effective in diagnosing fever or hypothermia.

  • PDF

Air Temperature Variation by Effect of Green Space Condition (녹지 조건에 따른 기온변화)

  • Yoon, Yong-Han
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.6 no.1
    • /
    • pp.28-33
    • /
    • 2003
  • In this study, we observed air temperature to make clear that land coverage condition and stand form has a certain relationship to air temperature during the night in various green space. And with revolution analysis, we interpreted relationship of air temperature distribution in the green space, The way of analysis is this land coverage rate and air temperature, of number of tree volume of tree air temperature. With this experimental result, we can propose green plan, which is taking into consideration lower effect of air temperature. In this result, lower zone is formed in forest and water area, higher zone is formed in paved surface and barren ground. but this gap is a little. arbor+subarbor area, in the point of water area surrounded stand is formed relative lower air temperature. As a result to make up efficiency lower air temperature area, it is needed to make water area which has surrounded forest, and it is needed to make stand form lower air temperature 2~3 layer forest. In order of arbor, subarbor, shrub, the lower air temperature is more effect.

Effect of Storage Temperature on the Dispersion Stability of O/W Nano-emulsions (O/W 나노에멀젼 분산안정성에 미치는 보관온도의 영향)

  • Lee, Ye-Eun;Yoo, In-Sang
    • KSBB Journal
    • /
    • v.29 no.5
    • /
    • pp.385-391
    • /
    • 2014
  • In this study, the emulsion dispersion stability of optimizing storage temperature was investigated. The system was based on oil/water (O/W) emulsions. In order to evaluate the stability, mean diameter of droplet was measured as a function of temperature with various mixed hydrophilic lipophilic balance (HLB). In addition, the correlations between phase inversion temperature (PIT) and the optimum storage temperature were probed. In this system, majority of the smallest droplet was shown at temperature of $20^{\circ}C$ below PIT. Whether the temperature was increased or decreased from the optimum, size of the droplet increased. According to the mixed HLB, the particle size and optimum storage temperature were also affected. As the concentrations of surfactant were increased, the size of particle decreased with lower optimum temperature for storage. If the surfactant (4 wt%) were mixed with HLB, the optimum storage temperature was $21^{\circ}C$ for maintaining the size of smallest droplet at 108.3 nm in diameter. At above optimum condition, increased size of particle was observed approximately 4 % increases from 108.2 nm to 112.3 nm after 600 hours. The size of particle in emulsion was maintained stably without any considerable effect of Ostwald ripening phenomena at the optimum storage temperature with low polydispersity index.