• Title/Summary/Keyword: TEMPERATURE

Search Result 88,815, Processing Time 0.075 seconds

Effects of Natural Convection Cells on Temperature Uniformity in Hot Plate Chamber for Wafer Baking Process (반도체용 핫플레이트 챔버 내 자연대류가 핫플레이트 표면 온도 균일도에 미치는 영향)

  • Park, Jun-Su;Kwon, Hyun-Goo;Cho, Hyung-Hee
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.2512-2517
    • /
    • 2007
  • Effect of natural convention for hot plate surface temperature uniformity was studied by experiments that were adjusted height of chamber and temperature difference. The hot plate chamber is composed of the hot plate and the upper heater and adiabatic vertical wall. The hot plate diameter is 220mm and maintains temperature at $150^{\circ}C$. Flow pattern compares with surface temperature and confirms that natural convection affects on temperature uniformity of hot plate surface. In case, temperature non-uniformity of hot plate surface is due to heater pattern, lots of weak and small flow cells more improve temperature uniformity than stronger flow cells or non-developing flow cell. Improve temperature uniformity $1.2^{\circ}C$ when developing weak and small flow cells.

  • PDF

A Study on Development of Curing Apparatus for In-place Standard Curing Specimen (현장 표준양생 공시체 관리함의 개발에 관한 연구)

  • 김경민;전충근;손성운;김기철;한천구
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2004.05a
    • /
    • pp.97-100
    • /
    • 2004
  • In-place curing box for specimens is used to cure the compressive strength specimens for control in place concrete. The box if composed of insulating chamber maintaining 20$\pm$3$^{\circ}C$ of temperature, in this paper, strength and temperature history of specimens cured at in plate curing box are investigated to verify field applicability. According to test results, air temperature at measured time shows large temperature variation and below zero, whereas, inside temperature of in place curing box maintains within 20$\pm$3$^{\circ}C$ due to temperature control function. For curing condition. temperature of specimens cured at outside shows large temperature deviation. specimens lured at in-place curing box is not affected by outer temperature.

  • PDF

Estimation Model of the Change in Dairy Leaf Surface Temperature Using Scaling Technique

  • Eom, Ki-Cheol;Eom, Ho-Yong
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.46 no.5
    • /
    • pp.359-364
    • /
    • 2013
  • This study was conducted to develop a model to estimate crop leaf surface temperature. The results were as following; A definition for the daily time based on elapsed time from the midnight (00:00) as "E&E time" with the unit of Kmin. was suggested. The model to estimate the scaled temperature ($T^*e$) of crop leaf surface temperature by scale factor ($T^*$) according to the "E&E time : Kmin."(X) was developed as eq. (1) $T^*e=0.5{\cdot}sin(X+780)+0.5$ (2) $T^*=(Tx-Tn)/(Tm-Tn)$, Tx : Daily leaf temperature, Tm : Daily maximum leaf temperature, Tn : Daily minimum leaf temperature. Relative sensitivity of the measured temperature compared to the estimated temperature of red pepper, soybean and persimmon was 1.078, 1.033 and 0.973, respectively.

A Study on the Shot Peening on the High Temperature Fatigue Crack Propagation (쇼트피이닝 가공된 스프링강의 고온 피로균열진전 평가)

  • 박경동;정찬기;하경준
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2001.10a
    • /
    • pp.264-268
    • /
    • 2001
  • In this study, CT specimens were prepared from spring steel(SUP9) processed shot peening which was room temperature, low temperature and high temperature experiment. And we got the following characteristics from fatigue crack growth test carried out in the environment of room, and high temperature at $25^{\circ}C,\; 50^{\circ}C, \;100^{\circ}C,\; 150^{\circ}C,\; and\; 180^{\circ}C$ in the range of stress ratio of 0.05 by means of opening mode displacement. The threshold stress intensity factor range $\DeltaK_{th}$ in the early stage of fatigue crack growth (Region I ) and stress intensity factor range $\Delta$K in the stable of fatigue crack growth (Region II) was decreased in proportion to descend temperature. It assumed that the fatigue resistance characteristics and fracture strength at low temperature and high temperature is considerable higher than that of room temperature in the early stage and stable of fatigue crack growth region.

  • PDF

Study on Economic analysis and Dessemination Policy of Unused Energy (미활용에너지의 경제적 효과 및 보급지원방안 연구)

  • An, Hyung-Jun;Baek, Sung-Kwon;Heo, Eunn-Yeong
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2008.05a
    • /
    • pp.95-98
    • /
    • 2008
  • Temperature difference energy is a good energy source replacing the fossil fuels. In the study, we classified the temperature difference energy as 4 types by the source & using method. For the understanding economic property of temperature difference energy, we tried simle economic analysis. As the result, Pay back period of 4 case of the temperature difference energy are from 1.23 to 12.65 years. Major factors influenced economic effect are operation time and energy user distance from the temperature difference energy source. If we can select optimal capacity and look for more effient energy users, Temperature difference energy play a important role of replacing fossil energy. So, for dess emination of temperature difference energy, we suggest that temperature difference energy must be included in renewable energy. Applying the effective methods among various promotion program of renewable energy policy, utilization of temperature difference energy could be activated.

  • PDF

Combustion Characteristics of A Regenerative Combustor with the Change of Alternating Period (절환주기 변화에 다른 축열 연소기의 연소특성)

  • Yang, B.O.;Lim, I.G.
    • Journal of the Korean Society of Combustion
    • /
    • v.4 no.1
    • /
    • pp.95-103
    • /
    • 1999
  • Experimental study on combustion characteristics of a regenerative combustor has performed. High-temperature air combustion in the regenerative combustor is obtained through heat recovery from exhaust gas flow by porous ceramic materials and through alternation of air flow direction through the combustor. Temperature field, CO and NOx emission with respect to the frequency of alternation are measured. It is found that at initial stage of the alternation, temperature of inlet section of main combustion chamber is increased sharply since both high temperature air preheated by the ceramics and prompt fuel injection results in rapid combustion. Following this initial stage, combustion temperature is reduced as the preheated air temperature is reduced. However peak temperature in the chamber and exhaust gas temperature are decreased as the alternation period is reduced, increased temperature of ceramic is observed. CO and NOx emission with respect to the alternation period is also examined. It is found that there exists a range of optimum alternating period for CO and NOx emission characteristics.

  • PDF

CFD ANALYSIS OF DISTRIBUTION OF AIR TEMPERATURE ON PLATFORMS OF A LARGE RAILWAY STATION IN SUMMER SEASON

  • Tsukamoto Kenji;Iino Akinaru;Tominaga Yoshihide
    • Proceedings of the KSRS Conference
    • /
    • 2005.10a
    • /
    • pp.173-177
    • /
    • 2005
  • The purpose of this study is to analyze the principal causes of increases in air temperature on platforms of railway station. We analyzed the distribution of air temperature on Shinkansen platforms at Station 'A' using Computational Fluid Dynamics (CFD). We focused on the factors that influence the temperature dynamics associated with heat generated by trains and station buildings and their effect on the ambient temperature on platforms. In the case of heat generated by trains, air temperature on Shinkansen platforms increased by 4 to 7 degrees compared to when trains generated no heat. When a 50-m high station building was located on the windward side of the platforms, air temperature on Platform X was 2 degrees higher than when the station buildings were absent. Air? temperature on platforms VII to IX increased progressively, and the maximum air temperature on platform VIII was 3 K higher than if station buildings were absent.

  • PDF

An Experimental Study on the Characteristics of Compressive Strength in Cement Mortar under High Temperature conditions in an Early Age (초기 고온이력이 시멘트 모르터의 강도발현에 미치는 영향에 관한 연구)

  • Kim Young-Joo;Choi Maeng-Ki;Gong Min-Ho;Park Hee-Gon;Kim Kwang-Ki;Jung Sang-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2005.05a
    • /
    • pp.45-48
    • /
    • 2005
  • This study is basic experiment for estimating influence of strength by curing temperature of concrete's heat of hydration and estimate relationship of compressive strength development by initial curing temperature factor, and then asume temperature factor which influence compressive strength development and for showing basic document of qualify control. According to the result of cement mortar by the curing temperature factor high-curing temperature shows high strength on 3 day compare with low curing-temperature, shows higher strength than the piece of high curing temperature.

  • PDF

The Study on the Temperature Distribution for 154kV Power Transformers (154kV 전력용 변압기의 온도분포에 관한 연구)

  • Woo, Jung-Wook;Koo, Kyo-Sun;Kwak, Joo-Sik;Kim, Kyung-Tak;Kweon, Dong-Jin
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.9
    • /
    • pp.56-61
    • /
    • 2011
  • The temperature of power transformers is very important factor for power system operation in substation because load capacity and limited lifetime of power transformers are determined by winding temperature. Also, The temperature of power transformers varies with the structure, capacity, operation condition and manufacturers. Thus, it is necessary for temperature distribution to be exactly investigated because of efficient load management and prediction of limited lifetime. Nevertheless, there was no case of analysis as well as measurement of the temperature of power transformers. In this paper, we manufactured the 154kV standard power transformer for the test. And we measured the temperature by the heat run test and analyzed the temperature distribution of transformer.

A Study on the Temperature-Dependent Discharge Characteristics in Alternating Current Plasma Display Panel (AC PDP의 온도에 따른 방전 특성 연구)

  • Lee, Seok-Hyun;Kim, Jee-Yong
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.3
    • /
    • pp.577-582
    • /
    • 2007
  • The plasma display panel is an image expression display using gas discharge plasma. However, gas discharge characteristics vary with temperature as gas discharge is sensitive to temperature. The discharge time lag extends a lot in low temperature and it is known as the cause which hinders high speed addressing which is essential for the size enlargement of the panel. Accordingly this research aims at identifying the temperature-dependent discharge characteristic. The lower temperature becomes, the longer addressing discharge time lag becomes. Particularly the statistical time lag extends much in low temperature. The increasing of electric field shortens discharge time lag in low temperature. Also, when priming particles are sufficiently supplied, stable discharge can be performed regardless of the influence of temperature.