• Title/Summary/Keyword: TEM observation

Search Result 259, Processing Time 0.03 seconds

TEM specimen preparation for observation of Cu oxides precipitated in the polyimide film and characterization of Cu oxide particles (폴리이미드박막내에 석출된 구리산화물 관찰을 위한 TEM 시편 제조와 구리산화물 분석)

  • You, Young-Sek;Kim, Young-Ho
    • Applied Microscopy
    • /
    • v.25 no.1
    • /
    • pp.130-138
    • /
    • 1995
  • TEM specimen preparation methods have been examined to characterize Cu oxide particles in the polyimide film. Polyimide films were prepared by coating polyamic acid onto Cu films which had been deposited on TEM-mask and glass substrates and Cu foil, followed by thermal curing. In case of TEM-mask, direct observation was possible without further preparation. In other cases, TEM specimen were made by separating polyimide film from the substrate. Polyimide films were removed from glass and Cu foil by dissolving glass in HF solution and Cu foil in $H_{2}SO_{4}$ solution. TEM-mask observation confirms that fine $Cu_{2}O$ particles precipitate in the polyimide as a result of reaction of polyamic acid with Cu. However $Cu_{2}O$ particle reacts with HF and $H_{2}SO_{4}$ solution during dissolving the substrate and interpretation could be misled. It is concluded characterization of $Cu_{2}O$ particle in polyimide using TEM-mask is better than other methods.

  • PDF

TEM sample preparation of microsized LiMn2O4 powder using an ion slicer

  • Jung Sik Park;Yoon‑Jung Kang;Sun Eui Choi;Yong Nam Jo
    • Applied Microscopy
    • /
    • v.51
    • /
    • pp.19.1-19.7
    • /
    • 2021
  • The main purpose of this paper is the preparation of transmission electron microscopy (TEM) samples from the microsized powders of lithium-ion secondary batteries. To avoid artefacts during TEM sample preparation, the use of ion slicer milling for thinning and maintaining the intrinsic structure is described. Argon-ion milling techniques have been widely examined to make optimal specimens, thereby making TEM analysis more reliable. In the past few years, the correction of spherical aberration (Cs) in scanning transmission electron microscopy (STEM) has been developing rapidly, which results in direct observation at an atomic level resolution not only at a high acceleration voltage but also at a deaccelerated voltage. In particular, low-kV application has markedly increased, which requires a sufficiently transparent specimen without structural distortion during the sample preparation process. In this study, sample preparation for high-resolution STEM observation is accomplished, and investigations on the crystal integrity are carried out by Cs-corrected STEM.

Synthesis of Graphene Using Thermal Chemical Vapor Deposition and Application as a Grid Membrane for Transmission Electron Microscope Observation (열화학증기증착법을 이용한 그래핀의 합성 및 투과전자현미경 관찰용 그리드 멤브레인으로의 응용)

  • Lee, Byeong-Joo;Jeong, Goo-Hwan
    • Korean Journal of Materials Research
    • /
    • v.22 no.3
    • /
    • pp.130-135
    • /
    • 2012
  • We present a method of graphene synthesis with high thickness uniformity using the thermal chemical vapor deposition (TCVD) technique; we demonstrate its application to a grid supporting membrane using transmission electron microscope (TEM) observation, particularly for nanomaterials that have smaller dimensions than the pitch of commercial grid mesh. Graphene was synthesized on electron-beam-evaporated Ni catalytic thin films. Methane and hydrogen gases were used as carbon feedstock and dilution gas, respectively. The effects of synthesis temperature and flow rate of feedstock on graphene structures have been investigated. The most effective condition for large area growth synthesis and high thickness uniformity was found to be $1000^{\circ}C$ and 5 sccm of methane. Among the various applications of the synthesized graphenes, their use as a supporting membrane of a TEM grid has been demonstrated; such a grid is useful for high resolution TEM imaging of nanoscale materials because it preserves the same focal plane over the whole grid mesh. After the graphene synthesis, we were able successfully to transfer the graphenes from the Ni substrates to the TEM grid without a polymeric mediator, so that we were able to preserve the clean surface of the as-synthesized graphene. Then, a drop of carbon nanotube (CNT) suspension was deposited onto the graphene-covered TEM grid. Finally, we performed high resolution TEM observation and obtained clear image of the carbon nanotubes, which were deposited on the graphene supporting membrane.

A New TEM Observation of the Copper Precipitate in High Strength Al-Cu-Mg Alloy (고강도 알루미늄 합금(Al-Cu-Mg)에서 새로운 Cu 석출물의 TEM 관찰)

  • Kim, Hwang-Su
    • Applied Microscopy
    • /
    • v.36 no.2
    • /
    • pp.47-55
    • /
    • 2006
  • In this paper a transmission electron microscope (TEM) observation of fine Cu precipitates distributed randomly in Al-2.5Cu-1.5Mg wt.% alloy is first reported. This new observation happened to occur when an ion milling was peformed to remove oxides on the specimen, particularly, aged 100 hours at $150^{\circ}C$. Meanwhile the oxides were identified to be $Cu_2O$ particles. For this work involved with analysis of diffraction rings, the formulation of the electron diffraction rings pattern for powder particles was made. Finally the significance of this unexpected ion milling effort on the alloy was discussed