EFFECT OF RESIN MATRIX ON DEGREE OF CONVERSION AND FRACTURE TOUGHNESS OF DENIAL COMPOSITES (기질레진의 조성에 따른 복합레진의 물리적 성질에 관한 연구)

  • Lee, Yun-Shin;Choi, Kyoung-Kyu;Park, Sang-Jin
    • Restorative Dentistry and Endodontics
    • /
    • v.27 no.1
    • /
    • pp.77-86
    • /
    • 2002
  • Current composites are made with dimethacrylate monomers and silane-treated silica microfillers, either alone or with silane treated glass fillers The main reasons for clinical failure of dental composites are secondary caries, wear and fracture. Most of practitioner want to get a composite which is more tougher under occlusal stress, less polymerization contraction, and better handling properties in application clinically. The aim of this study was to investigate the influence of resin matrix with various flows on the physical proper-ties such as fracture toughness and degree of conversion of the experimental resins. It was hypothesized that flexible or tough resin composites can be designed by judicious choice of monomer composition Various flow resin matrices containing Bis-GMA, UDMA, and TEG-DMA were made by altering the pro-portion of the monomers. After the unfilled resins were light-cured for different light intensity, the fracture toughness(K$_{1c}$) was measured according to ASTM standard using the single edge notched geometry, and degree of conversion(DC) was measured by FTIR. And experimental composites were formulated with variations in the proportion of silanated quartz and strontium glass fillers as 60, 75, and 77wt%. Also, the physical properties of composites with various filer contents were evaluated as same manner. All resulting data were compared by ANOVA/Tukeys test at 0.05 level. The results were as follows; 1. The degree of conversion of high flow resin containing less Bis-GMA was higher than that of low flow unfilled resin 2. While the degree of conversion of unfilled resin was increased according to light intensity for polymerization, there was no significant increase with moderate and high light intensity. Also, the fracture toughness was not increased by high light intensity. 3. The fracture toughness was high in the low flow unfilled resin containing higher contents of Bis-GMA. 4. There was a significant increase for fracture toughness and a tendency for degree of conversion to be reduced when the content of fillers was increased. 5. In the experimental composites, the flow of resin matrix did not affected on the fracture toughness, even, which was decreased as increase of viscosity. These results showed that the physical properties of a dental composite could be attributed to the flow of resin matrix with relative content of monomers. Specific combination of resin monomers should be designed to fulfil the needs of specific indication for use.

Changes of Coagulability after Off-pump CABG: Comparison with On-pump CABG (심폐바이패스 없이 시행하는 관상동맥우회술 후 혈액응고 기늠의 변화: 심폐바이패스하 관상동맥우회술 후 혈액응고 상태와의 비교)

  • 장우익;김기봉;김욱성;정철현;허재학;장지민;이동순;한규섭
    • Journal of Chest Surgery
    • /
    • v.37 no.3
    • /
    • pp.245-251
    • /
    • 2004
  • Hemostatic function is regarded to be preserved after an off-pump coronary artery bypass grafting (CABG), compared to conventional CABG, and the preserved hemostatic function may increase thrombotic occlusion of the graft. We studied the changes of hemostatic variables in patients undergoing off-pump CABG, and compared to those of on-pump CABG. We studied the changes of coagulation function in 11 patients who underwent off-pump CABG (group I), and compared them with those of 11 patients who underwent on-pump CABG and Dor procedure (group II). Coagulation status was evaluated by thromboelastography and blood coagulation test preoperatively, postoperative 1$^{st}$ day, 2$^{nd}$ day, 3$^{rd}$ day, and 5$^{th}$ day, respectively. Among the variables measured by thromboelastography (such as r time, k time, $\alpha$ angle, and MA value) and blood coagulation test (such as factor Ⅶ, protein S, protein C, antithrombin III, activated protein C resistance test, plasminogen, D-dimer, prothrombin time, activated partial thromboplastin time, platelet count, hemoglobin, and fibrinogen), there were significant differences in the MA value, $\alpha$ angle, and platelet counts between the two groups. MA values were 140$\pm$72% and 153$\pm$98% in group I, and 87$\pm$27% and 78$\pm$28% in group II, at postoperative 3$^{rd}$ and 5$^{th}$ days, respectively (p<0.05). $\alpha$ angle was 122$\pm$92% in group I and 69$\pm$23% in group II at postoperative 3$^{rd}$ day (p=0.09). Platelet count was 63$\pm$55% in group I and 33$\pm$13% in group II at postoperative 3$^{rd}$ day (p<0.05). Patients who underwent off-pump CABG showed increased coagulability during postoperative periods, compared to those who underwent on-pump CABG. Our data suggest that aggressive perioperative anticoagulation therapy is warranted in patients undergoing off-pump CABG. CABG.