• Title/Summary/Keyword: TEE

Search Result 309, Processing Time 0.021 seconds

Korean University Students' Perceptions about Native and Non-native English Speaking Teachers in TEE Courses

  • Yang, Taesun
    • English Language & Literature Teaching
    • /
    • v.17 no.3
    • /
    • pp.237-254
    • /
    • 2011
  • This study investigated Korean university students' perceptions of NESTs (Native English Speaking Teachers) and NNESTs (Non-native English Speaking Teachers) in TEE (Teaching English through English) courses to examine strengths and weaknesses of NESTs and NNESTs. 100 university students who had an experience in taking TEE courses with both NESTs and NNESTs answered the questionnaire in which they were asked to answer questions of general area, language skills, affective areas, and teaching behaviors. 20 students out of them were also interviewed to consolidate the data. The results revealed that except for speaking ability, students did not express a strong preference for NESTs and they did have a preference in learning some specific skills. In terms of affective areas, students had a preference for NNESTs. In addition, there were differences in teaching behaviors of NESTs and NNESTs. These findings have valuable implications for NNESTs to improve their speaking proficiency: analyzing and participating in discourses, and monitoring teaching practice through videotaping.

  • PDF

Three-Dimensional Rigid Plastic Fintie Element Analysis of Extruding-bulging Process of Tee Tubes

  • Shan, Debin;Kim, Hyun-Soo;Kim, Young-Suk
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2000.04a
    • /
    • pp.35-39
    • /
    • 2000
  • Three-dimensional rigid plastic FEM is adopted to analyze the extruding-bulging process of tee tubes. Equivalent strain-rate stress distributions and the deformation characteristic in extruding-bulging process of tee tubes are revealed which provide scientific and reliable basis for correctly designing technologcial scheme and rationally selecting parameters. meanwhile some approaches for three-dimensional rigid plastic FEM are also discussed in this paper

  • PDF

ASSESSMENT OF THERMAL FATIGUE IN MIXING TEE BY FSI ANALYSIS

  • Jhung, Myung Jo
    • Nuclear Engineering and Technology
    • /
    • v.45 no.1
    • /
    • pp.99-106
    • /
    • 2013
  • Thermal fatigue is a significant long-term degradation mechanism in nuclear power plants. In particular, as operating plants become older and life time extension activities are initiated, operators and regulators need screening criteria to exclude risks of thermal fatigue and methods to determine significant fatigue relevance. In general, the common thermal fatigue issues are well understood and controlled by plant instrumentation at fatigue susceptible locations. However, incidents indicate that certain piping system Tee connections are susceptible to turbulent temperature mixing effects that cannot be adequately monitored by common thermocouple instrumentations. Therefore, in this study thermal fatigue evaluation of piping system Tee-connections is performed using the fluid-structure interaction (FSI) analysis. From the thermal hydraulic analysis, the temperature distributions are determined and their results are applied to the structural model of the piping system to determine the thermal stress. Using the rain-flow method the fatigue analysis is performed to generate fatigue usage factors. The procedure for improved load thermal fatigue assessment using FSI analysis shown in this study will supply valuable information for establishing a methodology on thermal fatigue.

Shear Test on New Modified Double Tee Slabs including Service Ducts at the Ends (단부에 설비덕트를 포함하는 새로운 더블티 전단실험)

  • Kim Yun Soo;Song Hyung Soo;Ryu Jeong Wook;Lee Bo Kyung;Lee Jung Woo;Yu Sung Yong
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.05a
    • /
    • pp.71-74
    • /
    • 2005
  • The increasement in the floor hight may be one of the most significant problem in the use of precast concrete double slab in the multi-story buildings. The modified double-tees including duct space at the ends of slab were considered in this study. The length and thickness of nib of modified double tee was increased to receive the uniform reaction from rectangular beam, while the original PCI dapped one to receive the point load from inverted tee beam to the leg of double tee. Shear tests were performed on the ends of the modified double tees which were designed by strut-tie model. The modified double tees generally show more ductile flexural failure in the long thickened nib. It is concluded that they show superior failure patterns than that of original dapped one with shear failure.

  • PDF

Prevalence of Patent Foramen Ovale and Diagnostic Efficacy of Transcranial Doppler Sonography in Cryptogenic Ischemic Stroke Patients

  • Kim, Dae-Sik;Kim, Byung-Weon;Cho, Sung-Jun
    • Biomedical Science Letters
    • /
    • v.15 no.1
    • /
    • pp.17-23
    • /
    • 2009
  • The prevalence of patent foramen ovale (PFO) in healthy persons was estimated as about $10{\sim}25%$ and was up to 40% in patients with stroke. Transesophageal echocardiography (TEE) was considered to be the most sensitive method to detect PFO and was used as the gold standard. Transcranial doppler sonography (TCD) of the middle cerebral artery (MCA) during a contrast (saline bubble) injection has recently been proposed as an alternative detecting method for PFO. In this study, we would like to know the difference between TCD value and TEE value in subjects with cryptogenic ischemic stroke. We performed TCD and TEE tests to detect PFO on 64 patients (30 women and 34 men, mean age was 59.4 years) with cryptogenic ischemic stroke. PFO prevalence through TCD was 45.3% (29 of 64 patients) and the prevalence through TEE was 34.4% (22 of 64 patients). There was no statistical significance between PFO test and TCD test (P=0.206). But TCD had a sensitivity of 90.9% (20 of 22 patients), specificity of 78.6% (33 of 42 patients), positive predictive value of 69.0% (20 of 29 patients), and negative predictive value of 94.3% (33 of 35 patients). We concluded that TCD was a highly sensitive method for detecting a right-left shunt. Therefore, the non-invasive TCD test is a method more effective than the anti-invasive TEE test in the cost and evaluation of the existence or nonexistence of right to left shunt in addition to the screening method of the cerebrovascular disorder. Considering these points, TCD test could be recommended for patients with cryptogenic ischemic stroke as a useful and convenient method for screening of the existence or nonexistence of a right to left shunt caused by PFO.

  • PDF

Design of a Microwave Bias-Tee Using Lumped Elements with a Wideband Characteristic for a High Power Amplifier (광대역 특성을 갖는 집중 소자를 이용한 고출력 증폭기용 마이크로파 바이어스-티의 설계)

  • Oh, Hyun-Seok;Jeong, Hae-Chang;Yeom, Kyung-Whan
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.22 no.7
    • /
    • pp.683-693
    • /
    • 2011
  • In this paper, a design of high current and broad-band microwave bias-tee was presented for a stable bias of a high power amplifier. An input impedance of bias-tee should be shown to 50 ohm with the wideband in order to be stably-biased the amplifier. For this design of the bias-tee, a capacitor of bias-tee for a DC block was designed with a high wide-band admittance by a parallel sum of capacitors, and a inductor for a RF choke and a DC feeding was designed with a high wide-band impedance by a series sum of inductors. As this inductor and capacitor for the sum has each SRF, band-limitation of lumped element was driven from SRF. This limitation was overcome by control of a resonance's quality factor with adding a resistor. 1608 SMD chips for design's element was mounted on the this pattern for the designed bias-tee. The fabricated bias-tee presented 10 dB of return loss and wide-band about 50 ohm input impedance at 10 MHz~10 GHz.

Continuity for Double Tee Slabs (더블티 슬래브의 연속화)

  • 유승룡
    • Journal of the Korea Concrete Institute
    • /
    • v.13 no.2
    • /
    • pp.99-106
    • /
    • 2001
  • The main objective of this study is to develop a continuity of double tee slab with two modified dap-ends to solve the problems of excessive moment, slab depth, deflection, and joint cracking in the original simply supported double tee slab systems. The modified joint is produced in a combination with two slabs with modified dap and one rectangular beam. The modified joint can be justified as following different merits. The span capacity for a design load is increased, while the deflection of the slab is decreased due to the decrease of positive moment at the center span of the slab. The joint cracking between slab and beam, which occur frequently in the original slab systems of double tee will be reduced. No more additional form work is needed to cast topping concrete for continuity. Three point loading tests are performed on the specimens with a variable of an amount of main longitudinal reinforcement to evaluate flexural and shear behavior. Following conclusions are obtained from the experimental investigation. The continuity of double tee slab effectively is provided by placing longitudinal steel reinforcement in the topping concrete over the connection, and generally leads to an increase in span capacity of double tee slabs with reduced deflection. It is more effective to control the initial cracking at the connection than that of some simply supported double tee slab systems.

Proposal of Connection Details for a Double Split Tee Connection Without a Shear tap (전단탭이 없는 상·하부 스플릿 티 접합부의 접합부상세 제안)

  • Yang, Jae Guen;Lee, Hyung Dong;Kim, Yong Boem;Pae, Da Sol
    • Journal of Korean Society of Steel Construction
    • /
    • v.27 no.5
    • /
    • pp.423-433
    • /
    • 2015
  • A double split tee connection, which is a beam-column moment connection, shows different behavioral characteristics under the influences of the thickness of a T-stub flange, a high-strength bolt gauge distance, and the number and diameter of a high-strength bolt. A double split tee connection is idealized and designed that a flexural moment normally acting on connections can be resisted by a T-stub and a shear force by a shear tap. However, where a double split tee connection is adopted to a low-and medium-rise steel structure, a small-sized beam member can be adopted. Then, a shear tab may not be bolted to the web of a beam. This study was conducted to suggest the details of a connection to secure that a double split tee connection with a geometric shape has a sufficient capacity to resist a shear force. To verify this, this study was conducted to make a three-dimensional nonlinear finite element analysis on a double split tee connection.

Comparison of total energy intakes estimated by 24-hour diet recall with total energy expenditure measured by the doubly labeled water method in adults

  • Kim, Eun-Kyung;Fenyi, Justice Otoo;Kim, Jae-Hee;Kim, Myung-Hee;Yean, Seo-Eun;Park, Kye-Wol;Oh, Kyungwon;Yoon, Sungha;Ishikawa-Takata, Kazuko;Park, Jonghoon;Kim, Jung-Hyun;Yoon, Jin-Sook
    • Nutrition Research and Practice
    • /
    • v.16 no.5
    • /
    • pp.646-657
    • /
    • 2022
  • BACKGROUND/OBJECTIVES: The doubly labeled water (DLW) method is the gold standard for estimating total energy expenditure (TEE) and is also useful for verifying the validities of dietary evaluation tools. In this study, we compared the accuracy of total energy intakes (TEI) estimated by the 24-h diet recall method with TEE obtained using the doubly labeled water method. SUBJECTS/METHODS: This study involved 71 subjects aged 20-49 yrs. Over a 14-day period, three 24-h diet recalls per subject (2 weekdays and 1 weekend day) were used to estimate energy intakes, while TEE was measured using the DLW method. The paired t-test was used to determine the significance of differences between TEI and TEE results, and the accuracy of the 24-h recall method was determined by accuracy predictions percentage, root mean square error, and bias. RESULTS: Average study subject age was 33.4 ± 8.6 yrs. The association between TEI and TEE was positive and significant (r = 0.463, P < 0.001), and the difference between TEI (2,084.3 ± 684.2 kcal/day) and TEE (2,401.7 ± 480.3 kcal/day) was also significant (P < 0.001). In all study subjects, mean TEI was 12.0% (307.5 ± 629.3 kcal/day) less than mean TEE, and 12.2% (349.4 ± 632.5 kcal/day) less in men and 11.8% (266.7 ± 632.5 kcal/day) less in women. Rates of TEI underprediction for all study subjects, men, and women, were 60.5%, 51.4%, and 66.7%, respectively. CONCLUSIONS: This study shows that 24-h diet recall underreports energy intakes. More research is needed to corroborate our findings and evaluate the accuracy of 24-h recall with respect to additional demographics.

Utility of Multidetector Computed Tomographic Angiography as an Alternative to Transesophageal Echocardiogram for Preoperative Transcatheter Mitral Valve Repair Planning

  • Craig Basman;Caroline Ong;Tikal Kansara;Zain Kassam;Caleb Wutawunashe;Jennifer Conroy;Arber Kodra;Biana Trost;Priti Mehla;Luigi Pirelli;Jacob Scheinerman;Varinder P Singh;Chad A Kliger
    • Journal of Cardiovascular Imaging
    • /
    • v.31 no.1
    • /
    • pp.18-23
    • /
    • 2023
  • BACKGROUND: Three-dimensional (3D) transesophageal echocardiogram (TEE) is the gold standard for the diagnosis of degenerative mitral regurgitation (dMR) and preoperative planning for transcatheter mitral valve repair (TMVr). TEE is an invasive modality requiring anesthesia and esophageal intubation. The severe acute respiratory syndrome coronavirus 2 pandemic has limited the number of elective invasive procedures. Multi-detector computed tomographic angiography (MDCT) provides high-resolution images and 3D reconstructions to assess complex mitral anatomy. We hypothesized that MDCT would reveal similar information to TEE relevant to TMVr, thus deferring the need for a preoperative TEE in certain situations like during a pandemic. METHODS: We retrospectively analyzed data on patients who underwent or were evaluated for TMVr for dMR with preoperative MDCT and TEE between 2017 and 2019. Two TEE and 2 MDCT readers, blinded to patient outcome, analyzed: leaflet pathology (flail, degenerative, mixed), leaflet location, mitral valve area (MVA), flail width/gap, anterior-posterior (AP) and commissural diameters, posterior leaflet length, leaflet thickness, presence of mitral valve cleft and degree of mitral annular calcification (MAC). RESULTS: A total of 22 (out of 87) patients had preoperative MDCT. MDCT correctly identified the leaflet pathology in 77% (17/22), flail leaflet in 91% (10/11), MAC degree in 91% (10/11) and the dysfunctional leaflet location in 95% (21/22) of patients. There were no differences in the measurements for MVA, flail width, commissural or AP diameter, posterior leaflet length, and leaflet thickness. MDCT overestimated the measurements of flail gap. CONCLUSIONS: For preoperative TMVr planning, MDCT provided similar measurements to TEE in our study.