• Title/Summary/Keyword: TE6

Search Result 883, Processing Time 0.028 seconds

Effects of post-annealing temperature of CeO$_2$ buffer layers on the surface morphology, structures and microwave properties of YBa$_2$Cu$_3$O$_{7-{\delta}}$ films on sapphire

  • Yang, W.I.;Lee, J.H.;Ryu, J.S.;Ko, Y.B.;Chung, Y.S.;Hur, Jung;Lee, Sang-Young
    • 한국초전도학회:학술대회논문집
    • /
    • v.10
    • /
    • pp.201-206
    • /
    • 2000
  • Effects of the post-annealing temperature of CeO$_2$ buffer layers on the properties of YBCO films on CeO$_2$-buffered sapphire were investigated. 45 nm-thick CeO$_2$ buffer layer was prepared in-situ on r-cut sapphire using an on-axis rf magnetron sputtering method, which was later post-annealed at temperatures between 950$^{\circ}$C and 1100$^{\circ}$C in an oxygen-flowing environment. YBCO films were prepared on CeO$_2$-buffered sapphire (CbS), for which the surface morphology, crystal structures and electrical properties of the YBCO films were studied. YBCO films on post-annealed CbS appeared to have better properties than those on as-grown CbS with regard to the morphological, structural and electrical properties when the YBCO films were prepared on CeO$_2$ buffer layer post-annealed at temperatures of 1000 - 1050$^{\circ}$C. A TE$_{011}$ mode rutileloaded cylindrical cavity resonators was fabricated with the YBCO films placed as the endplates, for which the unloaded Q of the resonator was measured. It turned out that the resonator with the endplates prepared from the YBCO films on postannealed CbS at 1000 $^{\circ}$C showed the highest unloaded Q with the value more than 8 ${\times}$ 10$^5$ at 30 K and 8.6 CHz, revealing that the YBCO films on post-annealed CbS at 1000$^{\circ}$C the temperature could be the lowest among the YBCO films on post-annealed CbS.

  • PDF

Development of the Near Infrared Camera System for Astronomical Application

  • Moon, Bong-Kon
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.35 no.1
    • /
    • pp.39.2-39.2
    • /
    • 2010
  • In this paper, I present the domestic development of near infrared camera systems for the ground telescope and the space satellite. These systems are the first infrared instruments made for astronomical observation in Korea. KASINICS (KASI Near Infrared Camera System) was developed to be installed on the 1.8m telescope of the Bohyunsan Optical Astronomy Observatory (BOAO) in Korea. KASINICS is equipped with a $512{\times}512$ InSb array enable L band observations as well as J, H, and Ks bands. The field-of-view of the array is $3.3'{\times}3.3'$ with a resolution of 0.39"/pixel. It employs an Offner relay optical system providing a cold stop to eliminate thermal background emission from the telescope structures. From the test observation, limiting magnitudes are J=17.6, H=17.5, Ks=16.1 and L(narrow)=10.0 mag at a signal-to-noise ratio of 10 in an integration time of 100 s. MIRIS (Multi-purpose InfraRed Imaging System) is the main payload of the STSAT-3 in Korea. MIRIS Space Observation Camera (SOC) covers the observation wavelength from $0.9{\mu}m$ to $2.0{\mu}m$ with a wide field of view $3.67^{\circ}{\times}3.67^{\circ}$. The PICNIC HgCdTe detector in a cold box is cooled down below 100K by a micro Stirling cooler of which cooling capacity is 220mW at 77K. MIRIS SOC adopts passive cooling technique to chill the telescope below 200K by pointing to the deep space (3K). The cooling mechanism employs a radiator, a Winston cone baffle, a thermal shield, MLI of 30 layers, and GFRP pipe support in the system. Opto-mechanical analysis was made in order to estimate and compensate possible stresses from the thermal contraction of mounting parts at cryogenic temperatures. Finite Element Analysis (FEA) of mechanical structure was also conducted to ensure safety and stability in launching environments and in orbit. MIRIS SOC will mainly perform the Galactic plane survey with narrow band filters (Pa $\alpha$ and Pa $\alpha$ continuum) and CIB (Cosmic Infrared Background) observation with wide band filters (I and H) driven by a cryogenic stepping motor.

  • PDF

MIRIS 우주관측카메라 FM Dewar 설계

  • Cha, Sang-Mok;Mun, Bong-Gon;Jeong, Ung-Seop;Lee, Dae-Hui;Nam, Uk-Won;Park, Yeong-Sik;Lee, Chang-Hui;Park, Seong-Jun;Lee, Deok-Haeng;Ga, Neung-Hyeon;Han, Won-Yong;Park, Jang-Hyeon;Seon, Gwang-Il;Yang, Sun-Cheol;Park, Jong-O;Lee, Seung-U;Lee, Hyung-Mok;Matsumoto, Toshio
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.35 no.1
    • /
    • pp.40.2-40.2
    • /
    • 2010
  • MIRIS 우주관측카메라는 과학기술위성 3호의 주탑재체로서 $0.8{\sim}2.0{\mu}m$의 근적외선영역에서 우주배경복사와 우리은하 평면의 Pa-$\alpha$ survey 관측을 목적으로 한다. 이러한 임무를 수행하기 위해 MIRIS 우주관측카메라에는 MCT(HgCdTe) IR 검출기가 사용되고 6개의 필터를 장착할 수 있는 필터휠이 설계되었으며, 열잡음을 줄이고 원하는 SNR을 얻기 위해 모두 100K 이하로 냉각이 요구된다. 효과적인 냉각 및 저온유지를 위해서 외부의 열을 1차적으로 차단하는 Cryostat 외부용기와 100K 이하로 냉각되는 내부 Cold Box의 이중구조를 가지는 Dewar가 설계 되었다. 내부 Cold Box의 냉각은 소형 stirling cooler로 이루어지고 외부의 열 유입량이 Cooler의 냉각용량을 넘지 않도록 설계하였다. Cryostat 외부용기는 radiation cooling으로 냉각되어 200K 이하의 온도를 유지하며 내부 Cold Box로의 열유입을 최소화하기 위해 GFRP(Glass Fiber Reinforced Plastic) 단열 지지대와 MLI(Multi Layer Insulation)가 사용된다. 또한 100K으로 냉각시 필터고정부와 Cold Box 구조에서 일어날 수 있는 구조적인 피로도를 줄이고 열변형에 의한 문제를 방지하기 위한 고려가 설계에 포함되었다. FM(Flight Model)은 고진공 환경의 우주공간에서 문제가 발생하지 않도록 설계되었다. 또한 EQM 진동시험결과를 토대로 발사환경에서 발생하는 강한 진동을 견딜 수 있도록 FEM(Finite Elements Method) 구조해석을 통하여 필터고정부에 flexible structure 설계와 완충제를 추가하고 필터휠 구동부와 harness 고정부 및 cooler 지지부를 비롯한 전체 구조물에서 충분히 진동을 극복할 수 있도록 설계하였다.

  • PDF

Bidirectional Regulation of Manganese Superoxide Dismutase (MnSOD) on the Radiosensitivity of Esophageal Cancer Cells

  • Sun, Guo-Gui;Hu, Wan-Ning;Wang, Ya-Di;Yang, Cong-Rong;Lu, Yi-Fang
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.13 no.7
    • /
    • pp.3015-3023
    • /
    • 2012
  • The mitochondrial antioxidant protein manganese superoxide dismutase (MnSOD) may represent a new type of tumor suppressor protein. Overexpression of the cDNA of this gene by plasmid or recombinant lentiviral transfection in various types of cancer leads to growth suppression both in vitro and in vivo. We previously determined that changes in MnSOD expression had bidirectional effects on adriamycin (ADR) when combined with nitric oxide (NO). Radiation induces free radicals in a manner similar to ADR, so we speculated that MnSOD combined with NO would also have a bidirectional effect on cellular radiosensitivity. To examine this hypothesis, TE-1 human esophageal squamous carcinoma cells were stably transfected using lipofectamine with a pLenti6-DEST plasmid containing human MnSOD cDNA at moderate to high overexpression levels or with no MnSOD insert. Blastidicin-resistant colonies were isolated, grown, and maintained in culture. We found that moderate overexpression of MnSOD decreased growth rates, plating efficiency, and increased apoptosis. However, high overexpression increased growth rates, plating efficiency, and decreased apoptosis. When combined with NO, moderate overexpression of MnSOD increased the radiosensitivity of esophageal cancer cells, whereas high MnSOD overexpression had the opposite effect. This finding suggests a potential new method to kill certain radioresistant tumors and to provide radioresistance to normal cells.

Effects of Electroacupuncture on the Hemiplegic Upper Extremity after Stroke (중풍 환자의 상지마비에 대한 전침치료의 효과)

  • 류순현;이경섭;김태경;최요섭;윤상필;장종철;문상관;고창남;조기호
    • The Journal of Korean Medicine
    • /
    • v.23 no.2
    • /
    • pp.180-189
    • /
    • 2002
  • Background and Purpose : The hemiplegic upper extremity is affected in many stroke patients, and recovery is often poor. The purpose of this study was to assess the efficacy of electroacupuncture (EA) in enhancing the upper extremity motor and functional recovery of ischemic stroke patients. Subjects and Methods : Forty ischemic stroke patients (the upper extremity Fugl-Meyer motor scale (FM) score lower than 46, lesion location within middle cerebral artery territory) within 2 weeks of stroke onset were randomly allocated to either an EA group that received EA treatment or a control group that received only routine ward care. The EA was applied at Quchi-Shousanli (LI11-LI10), Waiguan-Hegu (TE5-LI4) points on the hemiparetic side six times per week for 4 weeks. The frequency of stimulation was 25-50Hz and the intensity was set at a level sufficient to induce muscle contraction. EA treatment was given for 30 minutes and all patients of both groups received standard rehabilitation program. Outcomes were assessed, in a blind manner, before treatment began and at 4 weeks after treatment, with the FM, the Motor Power score (MP) for shoulder/elbow, and the subsection of the Modified Barthel Index (MBI) for drinking/feeding/dressing upper body/grooming. Results : These 2 groups had comparable clinical characteristics, lesion location, lesion size, and pretreatment impairment scores. By the end of treatment, the EA group showed significantly more improvement than the control group in the subsection of the FM for shoulder/elbow/coordination (6.4 vs. 3.7; P=0.047) and the MP for shoulder/elbow (5.3 vs. 3.3; P=0.008). The subsection scores of the MBI for drinking/feeding/dressing upper body/grooming were not significantly different between two groups. No adverse effects due to treatment were found Conclusion : These results suggest that EA enhances the upper extremity motor recovery of acute stroke patients. However, this study failed to demonstrate any significant functional benefit related with upper extremity. Future study should be carried out in a larger sample size and use the functional outcome measure that is more specific and sensitive to the upper extremity.

  • PDF

Simulation of Resonance Shift and Quality Factor for Opto-fluidic Ring Resonator (OFRR) Biosensors (광-유체링공진기(OFRR) 바이오센서에 관한 공진이동과 양호도의 시뮬레이션)

  • Cho, Han-Keun;Han, Jin-Woo;Yang, Gil-Mo
    • Journal of Biosystems Engineering
    • /
    • v.36 no.1
    • /
    • pp.23-32
    • /
    • 2011
  • In this work, the finite element method was used to investigate the shifts of resonance frequencies and quality factor of whispering-gallery-mode (WGM) for an opto-fluidic ring resonator (OFRR) biosensor. To describe the near-field radiation transfer, the time-domain Maxwell's equations were employed and solved by using the in-plane TE wave application mode of the COMSOL Multiphysics with RF module. The OFRR biosensor model under current study includes a glass capillary with a diameter of 100 mm and wall thickness of 3.0 mm. The resonance energy spectrum curves in the wavelength range from 1545 nm to 1560 nm were examined under different biosensing conditions. We mainly studied the sensitivity of resonance shifts affected by changes in the effective thickness of the sensor resonator ring with a 3.0 mm thick wall, as well as changes in the refractive index (RI) of the medium inside ring resonators with both 2.5 mm and 3.0 mm thick walls. In the bulk RI detection, a sensitivity of 23.1 nm/refractive index units (RIU) is achieved for a 2.5 mm thick ring. In small molecule detection, a sensitivity of 26.4 pm/nm is achieved with a maximum Q-factor of $6.3{\times}10^3$. These results compare favorably with those obtained by other researchers.

Surgical Outcomes of Intra-articular Fractures of Calcaneus using AO Calcaneal Plate (관절내 종골 골절에 대해 AO 종골 금속판을 이용한 수술적 치료 결과)

  • Kim, Seong-Tek;Youn, Te-Hyun;Park, Jin-Bum;Lee, Jun-Young
    • Journal of Korean Foot and Ankle Society
    • /
    • v.13 no.1
    • /
    • pp.75-79
    • /
    • 2009
  • Purpose: To evaluate the outcomes of intra-articular calcaneal fractures treated using AO calcaneal plate surgically. Materails and Methods: Total 15 cases of intra-articular calcaneal fracture that treated with open reduction and internal fixation using AO calcaneal plate were evaluated. The patients were followed over a mean period of 19.8 months. The mean age was 41.6 years. By Sanders classification, there were 2 cases of type II, 10 cases of type III, and 3 cases of type IV. We evaluated radiological outcomes by Bohler angle, Gissane angle, calcaneal hight, calcaneal width and clinical outcomes by Creighton-Nebraska health foundation score. Results: All fractures united at a mean duration of 13.3 weeks. Radiologically, the mean preoperative Bohler angle was $8.5^{\circ}$ and restored to $23.3^{\circ}$. The mean preoperative Gissane angle was $118.7^{\circ}$ and restored to $124.2^{\circ}$. The mean preoperative calcaneal hight was 30.8 mm and restored to 38.9 mm. The mean preoperative calcaneal width was 41.3 mm and restored to 35.3 mm. 10 cases had excellent and good clinical outcomes and 5 cases having fair outcome. Conculsion: In our study, open reduction and internal fixation using AO calcaneal plate showed good results with anatomical restoration of articular surface and stable fixation without late collapse.

  • PDF

Comparative Study for the Unloaded Quality Factors of High-Tc Superconductor-Dielectric Resonators Measured by Using S-parameter Circle-fit Method and Lorentzian-fit Method (S-parameter circle fit 방법과 Lorentzian fit 방법으로 측정된 고온초전도 유전체 공진기의 Unloaded Quality Factor 비교)

  • Kim, M.J.;Lee, J.H.;Park, E.K.;Yang, W.I.;Jung, H.S.;Choi, Y.O.;Lee, S.Y.
    • Progress in Superconductivity
    • /
    • v.8 no.2
    • /
    • pp.143-151
    • /
    • 2007
  • Accurate measurements of the microwave surface resistance (Rs) of high temperature superconductor (HTS) films are important with regard to applications of HTS materials for wireless communications. As the surface resistance values of HTS films are usually extracted from the measured unloaded quality factor ($Q_0$) of resonators made of HTS films, it is essential to measure the resonator $Q_0$ with accuracy. The $TE_{011}\;mode\;Q_0$ of sapphire resonators with the endplates made of $YBa_2Cu_3O_{7-{\delta}}$(YBCO) film on $LaAlO_3$ is measured by using the S-parameter circle-fit method at a frequency of about 19.6 GHz and temperatures of 30 K to 90 K, which is compared with the measured values by using the Lorentzian-fit method. Good agreements are found between the two sets of $Q_0$ values measured by using the two different methods whether the resonator is used in a weak-coupling scheme or a strong-coupling scheme, showing reliability of both methods fur measuring the resonator $Q_0$ accurately. The $Q_0$ of sapphire resonators with a gap between the top plate and the rest of the resonator is also discussed.

  • PDF

Scientific Study of Magnetic Acu-point Therapy on Eight Extraordinary Meridian for Lowering Blood Pressure (기경팔맥 자석침의 혈압 강하 효과에 대한 과학적 검증 연구)

  • Yoo, Ho-Rhyong;Lee, Jae-Hwi;Kang, Ji-Sun;Moon, Seung-Hee;Kang, Byung-Gab;Lim, Seung-Min;An, Joung-Jo;Jo, Hyun-Kyung;Kim, Yoon-Sik;Seol, In-Chan
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.24 no.1
    • /
    • pp.165-170
    • /
    • 2010
  • This study assessed effects of magnetic acu-point therapy as an add-on to conventional antihypertensive managements such as medication or lifestyle modification for hypertensive or pre-hypertensive subjects. This study was conducted with the purpose to evaluate the decreasing effect of the blood pressure on the hypertensive patients who were given to magnetic acu-point therapy. A single-blind, placebo-controlled trial by cross matching was conducted at Daejeon University Oriental Hospital. The washout periods of cross matching are 10 days. 22 hypertensive (systolic BP>140 mmHg or diastolic BP>90 mmHg) volunteers were recruited and treatments were donemagnetic acu-points on Oegwan(TE 5), Jogimeup(GB 41), Naegwan(PC 6), Gongson(SP 4), Hugye(SI 3), Sinmaek(BL 62). The treated group was statistically significant decrease of the blood pressure, while control group show no statistically significant difference of BP. From the results, magnetic acu-point therapy seems to offer a benefit to the treatment of hypertensive patients.

전이금속이 도핑된 Si 박막의 열처리 효과에 따른 구조 및 자기적 성질

  • Seo, Ju-Yeong;Park, Sang-U;Lee, Gyeong-Su;Song, Hu-Yeong;Kim, Eun-Gyu;Son, Yun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.184-184
    • /
    • 2011
  • 반도체 전자 소자의 초고집적회로(VLSI, Very Large Scale Integrated Circuit)가 수년간 지속됨에 따라 실리콘 기반으로 하는 MOSFET 성능의 한계에 도달하게 되었다. 재료 물성, 축소, 소자 공정 등에 대한 원인으로 이를 극복하고자 하는 재료와 성능향상에 관한 연구가 진행되고 있다. 이에 기존 시스템의 전자의 전하 정보만을 응용하는 것이 아니라 전자의 스핀 정보까지 고려하는 스핀트로닉스 연구분야가 주목을 받고 있다. Spin-FET는 스핀 주입, 스핀 조절, 스핀측정 등으로 나뉘어 연구되고 있으며 이 중 스핀 주입의 효율 향상이 우선시 해결되어야 한다. 일반적으로 스핀 주입 과정에서 소스가 되는 강자성체와 스핀 확산 거리가 긴 반도체 물질과의 Conductance mismatch가 문제되고 있다. 이에 자성 반도체는 근본적인 문제를 해결하고 반도체와 자성체의 특성을 동시에 나타내는 물질로써, Si과 Ge (4족) 등의 반도체뿐만 아니라, GaAs, InP (3-5족), ZnO, ZnTe (2-6족) 등의 반도체 또한 많은 연구가 이루어지고 있다. 자성 반도체에서 해결해야 할 가장 큰 문제는 물질이 자성을 잃는 Curie 온도를 상온 이상으로 높이는 것이다. 이에 본 연구는 전이금속이 도핑된 4족 Si 반도체 박막을 성장하고 후처리 공정을 통하여 나타나는 구조적, 자기적 특성을 연구하였다. 펄스 레이저 증착 방법을 통하여 p-type Si 기판위에 전이금속 Fe이 도핑된 박막을 500 nm 로 성장하였다. 성장 온도는 $250^{\circ}C$로 하였고, 성장 분압은 $3 {\times}10^{-3}$Torr 로 유지하며 $N_2$ 가스를 사용하였다. 구조적 결과를 보기 위해 X선 회절 분석과 원자력 현미경 결과를 확인하였고, 자기적 특성을 확인하기 위해 저온에서 초전도 양자 간섭계로 조사하였다. XRD를 통해 (002)면, (004)면의 Si 기판 결정을 보았으며, Fe 관련된 이차상이 형성됨을 예측해 보았다. ($Fe_3Si$, $Fe_2Si$ 등) 초전도 양자 간섭계에서 20 K에서 측정한 이력 현상을 관찰하고, 온도변화에 따른 전체 자기모멘트를 관찰하였으며 이는 상온에서도 강자성 특성이 나타남을 확인하였다.

  • PDF