• Title/Summary/Keyword: TDR sensors

Search Result 28, Processing Time 0.02 seconds

A Study on Estimation of Breakdown Location using UHF Sensors for Gas Insulated Transmission Lines (UHF센서를 이용한 가스절연송전선로 절연파괴 위치 추정에 관한 연구)

  • Park, Hung-Sok;Han, Sang-Ok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.4
    • /
    • pp.805-810
    • /
    • 2011
  • This paper deals with the method and algorithm used to find fault locations in gas insulated transmission line. The method uses UHF sensors and digital oscilloscope to detect discharge signals emitted to the outside through insulating spacer in the event of breakdown inside GIL. UHF sensors are the external type and installed at outside of insulating spacers of GIL. And we used wavelet signal processing to analyze the discharge signals and confirm the exact fault location findings in the GIL test line. This method can overcome demerit of TDR(Time Domain Reflectometer) method having been applied to detect fault location for conventional underground transmission lines, and Ground Fault Sensors used in conventional GIS systems. TDR method requires high level of specialty and experience in analyzing the measured signals. Ground fault sensors are installed inside GIL and can be destroyed by high transient voltage. This paper's method can simplify the fault location process and minimize the damage of sensors. In addition, this method can estimate the fault location only by the time difference when discharge signals are arrived to detecting sensors at the ends of GIL sections without reasons of breakdown. To test the performance of our method, we installed sensors at the ends of test line of GIL(84m) and sensed discharge signals occurred in GIL, energized with AC voltage generator up to 700kV.

A Study on Measuring and Calibration Method using Time Domain Reflectometry Sensor under Road Pavement (Time Domain Reflectometry 방식을 이용한 도로 하부의 함수비 계측 및 보정 방안에 관한 연구)

  • Cho, Myung-Hwan;Lee, Yoon-Han;Kim, Nak-Seok;Park, Joo-Young
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.10 no.2
    • /
    • pp.23-30
    • /
    • 2010
  • The research presents moisture content measuring and calibration method of road pavement, especially asphalt concrete pavement for performance evaluation or remaining life prediction using Time Domain Reflectometry(TDR) sensor, CS616 made by campbell INC. Before calibration test of CS616, accomplished a sensor verification tests. Verification test items were covering depth and interference effect of two CS616 sensors, temperature effects between $5^{\circ}C\sim25^{\circ}C$ and compaction ratio effects. Covering depth and interference effects between two CS616 sensors were just small and the effects of temperature and compaction ratio effected a Volumetric Moisture Contents at $\pm6%$ under disregard appeared with the fact that was possible. Also, obtained the calibration equation of the subgrade and subbase course, $R^2$ showed above of all 0.9.

Refractive index-based soil moisture sensor (굴절률 기반 토양 수분 센서)

  • Sim, Eun-Seon;Hwa, Su-Bin;Jang, Ik-Hoon;Na, Jun-Hee;Kim, Min-Hoi
    • Journal of Sensor Science and Technology
    • /
    • v.30 no.6
    • /
    • pp.415-419
    • /
    • 2021
  • We developed a highly accurate, yet inexpensive, refractive index (RI)-based soil moisture sensor. To detect the RI, a light guide was set with a light-emitting diode and photodiode. When the air fills the space between the soil particles, most of the incident light is reflected at the interface between the waveguide and the air because of the large RI difference. As the moisture of the soil increases, the macroscopic soil RI increases. This allows incident light to pass through the interface. The intensity of the light reaching the photodiode was simulated according to the change in the soil RI. Using the simulation results, we designed and manufactured a curved glass waveguide. We evaluated the performance of the RI-based soil sensor by comparing it with a commercially available, high-cost and high-performance time-domain reflectometer (TDR). Our sensor was 96% accurate, surpassing the costly TDR sensor.

Verification of Soil Volumetric Water Content Measured by TDR, FDR Sensors (TDR, FDR 센서로 측정한 토양수분 함량의 정확성 검정)

  • Hur, Seung-Oh;Jung, Kang-Ho;Park, Chan-Won;Ha, Sang-Keon;Kim, Jeong-Gyu
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2007.05a
    • /
    • pp.229-235
    • /
    • 2007
  • 관개나 수분수지 규명을 위한 기본적인 자료는 토양수분 함량이다. 그러나, 포장상태에서의 토양수분 함량은 직접 측정하는 것이 쉽지 않기 때문에 많은 경우 건조기를 이용한 중량수분 함량측정 방법을 이용하거나 토양수분 포텐셜 측정용인 텐시오미터를 이용한 토양수분의 에너지 특성을 관개에 활용하는 것이 현실이었다. 중량수분 함량은 시료를 채취해서 건조하기 때문에 시료채취 당시의 토양수분 함량을 아는 것이 어렵고, 토양수분 포텐셜은 에너지를 측정하는 것이기 때문에 이 역시 토양의 수분함량을 얻는 것이 불가능 하다. 따라서, 최근에 이런 측정상의 어려움을 극복하기 위해 여러 나라에서 포장에서의 토양수분 함량을 직접 측정하는 다양한 센서를 개발하고 있고 있다. 그 중 몇 가지는 현재 우리나라에 공급되고 있는데, 가격 등의 문제로 별로 알려져 있지는 않다. 센서는 현장에서 수분함량을 파악할 수 있는 장점이 있기 때문에 관개에 직접 적용이 가능하며 자동화시설이나 수분수지 모형 산정에도 활용할 수 있다. 본 시험은 우리나라에 소개되어 있는 몇 가지의 토양수분 측정용 센서를 현장에서 코어를 이용해 측정한 용적수분 함량과 비교하여 센서의 정확도나 이용 가능성을 검정하고자 하였다. 코어를 이용해 실측한 토양 용적수분 함량과 비교하고자 7종의 센서를 선택해 실험에 이용하였다. 가격이 비싼 것으로 알려진 TDR 형태의 센서가 2종이었으며, 나머지 5종은 FDR 형태의 센서였다. TDR 센서는 Soilmoisture사에서 제작한 MiniTrase와 Imko 사의 Trime이고, FDR은 Sentek사에서 개발한 EasyAG, EnviroSCAN과 Delta-T사에서 제작한 PR-1과 WET-2 및 Decagon사에서 제작한 $ECH_2O$ 센서였다. 실헙방법은 본량사양토인 포장에서 건조한 상태인 시험구와 물이 포화된 시험구를 만들어 놓고, 그곳에서 센서 종류별로, 측정 깊이별로 토양의 용적수분 함량을 측정하고, 센서로 측정한 위치 바로 옆에서 코어를 이용해 토양시료를 채취하고 이를 건조기에 건조해 용적수분 함량을 측정하였다. 비교결과 TDR인 MiniTrase가 결정계수$(r^2)$가 0.964이고 표준오차(SE)가 0.01로 좋은 결과를 보여줬고 WET-2가 $r^2$와 SE가 0.932와 0.013이였으며 EasyAG는 0.877과 0.0211, EnviroSCAN은 0.803과 0.0259의 값을 보였다. 일반적으로 토양수분 함량 측정오차가 1% 미만인 센서가 정확한 수분함량 해석을 유도할 것이지만 위의 센서 중 MiniTrase를 비롯한 4개의 센서 정도가 토양의 수분 함량을 측정하는데 유용할 것이라는 결론을 얻었다.

  • PDF

Effect of Water Content in Coir Substrates on the Growth and Yield of Mini-Paprika in Summer Hydroponics (여름철 소과형 파프리카 수경재배 시 코이어 배지함수량이 생육과 수량에 미치는 영향)

  • Rhee, Han Cheol;Choi, Gyoeng Lee;Roh, Mi Young;Jeong, Jae Woan;Cho, Myeung Hwan;Kim, Young Cheol;An, Chul Geun
    • Journal of Bio-Environment Control
    • /
    • v.21 no.3
    • /
    • pp.236-242
    • /
    • 2012
  • This study was carried out to investigate the effect the water content in coir substrates as according to growth stage on the growth and yield of mini-paprika of three varieties 'E 499524' (red color), 'E 499526' (yellow colar) and 'E 499531' (orange colar) in summer hydroponics. Treatments of I, II and III were composed of 55-65-60, 50-60-55 and 45-55-50% in water contents of growth stages, respectively. Time domain reflectometry (TDR) sensors were used in a drip irrigation system. The early growth of mini-paprika was increased by high medium water content of treatment I in all of three varieties. Mean fruit weight was not affected by medium water content, but the fruit number per plant and yield were increased at high medium water content of treatment I. The Yield of treatment I was higher than that of treatment II and III in all of three varieties. The sugar content was increased by low medium water content of treatment in all of three varieties. The incidence of brown-stem fruit, blossom-end rot and sunburn was decreased with increasing water content of medium. Occurred in the low water content of medium. Mineral contents of fruits such as nitrogen (N), potassium (K), calcium (Ca), magnesium (Mg) etc. were not affected in all of three varieties.

A Study on the Seepage Behavior of Embankment with Weak Zone using Numerical Analysis and Model Test (취약대를 가진 모형제방의 침투거동에 관한 연구)

  • Park, Mincheol;Im, Eunsang;Lee, Seokyoung;Han, Heuisoo
    • Journal of the Korean GEO-environmental Society
    • /
    • v.17 no.7
    • /
    • pp.5-13
    • /
    • 2016
  • This research is focused on the seepage behavior of embankment which had the weak zone with big permeability. The distributed TDR (Time Domain Reflectometer) and point sensors such as settlement gauge, pore water pressuremeter, vertical total stressmeter, and FDR (Frequency Domain Reflectometer) sensor were used to measure the seepage characteristics and embankment behavior. Also, the measured data were compared to the data of 2-D and 3-D numerical analysis. The dimension of model embankment was 7 m length, 5 m width and 1.5 m height, which is composed of fine-grained sands and the water level of embankment was 1.3 m height. The seepage behavior of measuring and numerical analysis were very similar, it means that the proper sensing system can monitor the real-time safety of embankment. The result by 2-D and 3-D numerical analysis showed similar saturation processing, however in case of weak zone, the phreatic lines of 2-D showed faster movement than that of 3-D analysis, and finally they converged.

Effect of Water Content in Substrates as According to Growth Stage on the Growth and Yield of Paprika in Summer Hydroponics (여름철 파프리카 수경재배 시 생육단계별 코이어 배지함수량이 생육과 수량에 미치는 영향)

  • Rhee, Han-Cheol;Seo, Tae-Cheol;Choi, Gyoeng-Lee;Roh, Mi-Young;Cho, Myeung-Whan;Kim, Young-Cheol
    • Journal of Bio-Environment Control
    • /
    • v.20 no.4
    • /
    • pp.258-262
    • /
    • 2011
  • This study was carried out to investigate the effect the water content in substrates as according to growth stage on the growth and yield of paprika in summer hydroponics. Treatments of I, II and III were composed of 55-65-60, 50-60-55 and 45-55-50 % in water contents of growth stages, respectively. Time domain reflectometry (TDR) sensors were used in a drip irrigation system. The early growth of paprika was increased by high medium water content of treatment I. Mean fruit weight was not affected by medium water content, but the fruit number per plant and yield were increased at high medium water content of treatment I. The yield of treatment I was higher than that of treatment II and III. The incidence of brown stem fruit, blossom end rot and sunburn was decreased with increasing water content of medium. Occurred in the low water content of medium. The nitrogen (N) was higher content in brown stem fruit than normal stem, but mineral contents such as potassium (K), calcium (Ca), magnesium (Mg) etc. were not affected.

Establishment and Operation of a Soil Moisture Monitoring System Considering Temporal and Spatial Features of Representation (시공간 대표성을 고려한 토양수분 모니터링 System의 구축 및 운영)

  • Kim, Ki-Hoon;Kim, Sang-Hyun;Kim, Hyung-Sub;Kim, Won
    • Journal of Korea Water Resources Association
    • /
    • v.38 no.1
    • /
    • pp.73-82
    • /
    • 2005
  • A soil moisture measuring method of a hillslope for Korean watershed is developed to configure spatial-temporal distribution of soil moisture. Intensive surveying of topography had been performed to make a digital elevation model(DEM). Flow distribution algorithms were applied and a distribution pattern of the measurement sensors was determined to maximize representative features of spatial variation of soil moisture. Inverse surveying provides appropriate information to install the waveguides in the field. Measurements were performed at the right side hillslope of Bumrunsa located at the Sulmachun watershed. A multiplex monitoring system has been established and spatial-temporal variation of soil moisture data has been measured for a rainfall-runoff event. Acquired soil moisture data show that physical hydrologic interpretations as well as the effectiveness of monitoring system. Lack of connectivity in vertical distribution of soil moisture suggests that preferential flow and macropore flux are important components in the hillslope hydrology.

A critical comparison of reflectometry methods for location of wiring faults

  • Furse, Cynthia;Chung, You Chung;Lo, Chet;Pendayala, Praveen
    • Smart Structures and Systems
    • /
    • v.2 no.1
    • /
    • pp.25-46
    • /
    • 2006
  • Aging wiring in buildings, aircraft and transportation systems, consumer products, industrial machinery, etc. is among the most significant potential causes of catastrophic failure and maintenance cost in these structures. Smart wire health monitoring can therefore have a substantial impact on the overall health monitoring of the system. Reflectometry is commonly used for locating faults on wire and cables. This paper compares Time domain reflectometry (TDR), frequency domain reflectometry (FDR), mixed signal reflectometry (MSR), sequence time domain reflectometry (STDR), spread spectrum time domain reflectometry (SSTDR) and capacitance sensors in terms of their accuracy, convenience, cost, size, and ease of use. Advantages and limitations of each method are outlined and evaluated for several types of aircraft cables. The results in this paper can be extrapolated to other types of wire and cable systems.

Effect of Air Humidity and Water Content of Medium on the Growth and Physiological Disorder of Paprika in Summer Hydroponics (여름철 착색단고추 수경재배 시 공중습도 및 배지함수량이 생육 및 과실의 생리장해에 미치는 영향)

  • Rhee, Han-Cheol;Seo, Tae-Cheol;Choi, Gyoeng-Lee;Roh, Mi-Young;Cho, Myeung-Whan
    • Journal of Bio-Environment Control
    • /
    • v.19 no.4
    • /
    • pp.305-310
    • /
    • 2010
  • This study was carried out to investigate the effect of air humidity and water content of medium on the growth and physiological disorder of paprika in summer hydroponics. Treatments were composed of air humidity of control (over 90%) and dehumidification (low 90%) and water content of 80% and 50%. Time domain reflectometry (TDR) sensors and dehumidifier were used in a drip irrigation system and control system of air humidity, respectively. The early growth of paprika was not affected by air humidity but increased by high water content (80%) of medium. Mean fruit weight was reduced at high air humidity and low water content (50%) of medium, but the fruit number per plant and yield were increased at low air humidity. The incidence of brown fruit stem increased with increasing air humidity and water content of medium. Rate of blossom end rot increased in the low water content medium compared with the high water content medium. The nitrogen (N) was higher content in brown fruit stem than normal stem, but calcium (Ca) was lower.