• Title/Summary/Keyword: TC4

Search Result 1,981, Processing Time 0.039 seconds

Reports on the Meetings of ISO/TC108 Mechanical Vibration and Shock and ISO/TC108/SC3 Use and Calibration of Shock Measuring Instruments Tokyo, Nov. 4-8, 2002

  • Kim, Kwang-Joon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.05a
    • /
    • pp.468-474
    • /
    • 2003
  • 1. Schedule for the meetings of ISO/TC108 Mechanical vibration and shock and ISO/TC108/SC3 Use and calibration of shock measuring instruments 2. Minutes for the seventh meeting of ISO/TC108/WG23 Mechanical vibration and shock - Resilient mounting systems - Information for the application of source and receiver isolation (omitted)

  • PDF

ISO TC307 블록체인 정보보호 표준기술 동향

  • NAH, Jae Hoon
    • Review of KIISC
    • /
    • v.32 no.4
    • /
    • pp.113-117
    • /
    • 2022
  • ISO/TC 307(블록체인/분산원장) 기술위원회에도 금융 이슈가 두각을 나타내고 있다. 영국이 TC 307에서의 활동은 조직적이고 열정적이다. 그 이면에는 지향하는 목표가 있다. 금융 대국 영국이 신기술 분야에서 핀테크를 어우르는 블록체인 기반 산업에서 선두 지위를 확보하고자 노력하고 있다는 것을 피부로 느낄 수 있는 활동이라고 판단이 된다. COVID-19 팬데믹의 어려움에도 불구하고 AG3 (Digital currencies)와 AHG3 (pNFT) 임시 그룹의 신설은 TC307 위원회에 신선한 자극을 주고 있다. 2022년 6월 온라인 총회를 중심으로 ISO/TC 307 기술위원회의 국제표준화 동향을 살펴본다.

Usefulness of Tc-99m MIBI Scan in the Postoperative Follow Up Of Well-Differentiated Thyroid Cancer (분화된 갑상선암의 수술후 경과 관찰에서 Tc-99m MIBI 스캔과 다른 추적 지표들의 유용성 비교)

  • You, Kye-Hwa;Song, Jae-Soon;Shinn, Joon-Jae;Lee, Hyun-Kyung;Cha, Wang-Ki;Kim, Do-Min;Kim, Eun-Sil;Kim, Chong-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.31 no.3
    • /
    • pp.356-364
    • /
    • 1997
  • To evaluate the clinical utility of Tc-99m MIBI scan in the detection of residual thyroid tissue or metastatic lesion in postoperative thyroid cancer patients, we compared Tc-99m MIBI scan with I-131 diagnostic and therapeutic scan in 30 postoperative well-differentiated thyroid cancer patients. Thyroglobulin levels of both on and off thyroid hormone medication and antithyroglobulin antibody were tested [Tg(on), Tg(off)]. Positive rates for I-131 diagnostic and Tc-99m MIBI scan were 81% and 68% respectively. Concordance between I-131 diagnostic and Tc-99m MIBI scan was observed in 15 cases; 12 positive and 3 negative respectively. Among the 6 cases with negative I-131 diagnostic scan and positive Tc-99m MIBI scan, 4 were Positive in the therapeutic I-131 scan We concluded that Tc-99m MIBI scan maybe a useful complementary modality to the currently established method of I-131 scan and serum thyroglobulin level in the detection of recurrent or metastatic thyroid cancer, especially in the case of negative I-131 diagnostic scan.

  • PDF

Diagnostic Role of Tc-99m MIBI Scintimammography in Suspected Breast Cancer Patients: Results of Unicenter Trial (유방암이 의심되는 환자에서 Tc-99m MIBI 유방스캔의 진단적 역할: 단일기관의 결과)

  • Kim, Seong-Jang;Kim, In-Ju;Kim, Yong-Ki;Bae, Young-Tae
    • The Korean Journal of Nuclear Medicine
    • /
    • v.34 no.3
    • /
    • pp.234-242
    • /
    • 2000
  • Purpose: Tc-99m MIBI scintimammography has been validated as an useful non-invasive diagnostic tool for the primary breast cancer. But most studies have included small population of patients. We have experienced a large study population and investigated the diagnostic usefulness of Tc-99m MIBI scintimammography in detection of primary breast cancer and axillary lymph node metastasis. Materials and Methods: This study included 305 patients who underwent scintimammogtaphy for palpable breast masses or abnormal radiologic findings. Tc-99m MIBI scintimammography was performed 10 minutes after intravenous injection of 925 MBq of Tc-99m MIBI. If the early image revealed abnormal finding, 3 hour delayed image was also acquired. We calculated early and delayed lesion to non-lesion ratios (L/N). The pathologic diagnosis was obtained from surgical operation or FNAB and compared with the results of Tc-99m MIBI scintimammography. Results: Malignant breast diseases were 155 and benign ones were 150. Tc-99m MIBI scintimammography revealed 132 true positive, 23 false negative, 10 false positive, and 140 true negative cases. The sensitivity, specificity, positive predictive value and negative predictive value for the primary breast cancer detection were 85.2%, 93.4%, 92.9%, and 85.9%, respectively. The sensitivity, specificity, positive predictive and negative predictive values of Tc-99m MIBI scintimammography in detecting metastatic axillary lymph node involvement were 22%, 90.4%, 61.9% and 62.3%, respectively. Early L/N of malignant breast disease was significantly higher than that of benign one ($2.44{\pm}0.97\;vs\;1.94{\pm}0.78$, p=0.01). Delayed L/N had no significant difference between malignant and benign breast diseases ($1.94{\pm}0.52\;vs\;1.91{\pm}0.73$, p=0.43). Conclusion: Our study revealed that Tc-99m MIBI scintimammography was an useful diagnostic tool for the diagnosis of breast cancer. And early L/N ratio might provide complementary role in the detection of breast cancer. But the Tc-99m MIBI scintimammography had limited value in the detection of small breast cancer (less than 1 cm) and axillary lymph node metastasis.

  • PDF

Optimization of Correction Factor for Linearization with Tc-99m HM PAO and Tc-99m ECD Brain SPECT (Tc-99m HMPAO와 Tc-99m ECD 뇌SPECT의 뇌혈류량 정량화에 사용되는 Linearization Algorithm의 Correction Factor 조사)

  • Cho, Ihn-Ho;Hayashida, Kohei;Won, Kyu-Chang;Lee, Hyoung-Woo;Watabe, Hiroshi;Kume, Norihiko;Uyama, Chikao
    • Journal of Yeungnam Medical Science
    • /
    • v.16 no.2
    • /
    • pp.237-243
    • /
    • 1999
  • We conducted this study to find the optimal correction factor(${\alpha}$) of Lassen's linearization algorithm which has been applied for correction of flow-limited uptake at a high flow range in $^{99m}Tc$ d,l-hexamethylpropy leneamine oxime(HMPAO) and $^{99m}Tc$ ethyl cysteinate dimer(ECD). Ten patients with chronic cerebral infarction were involved in this study. We obtained the corrected $^{99m}Tc$ HMPAO and $^{99m}Tc$-ECD brain SPECT(single photon emission computed tomography) using the algorithm with ${\alpha}$ values that varied from 0.1 to 10 and compared the results with regional cerebral blood flow determined by positron emission tomography (PET-rCBF). The multi-modal volume registration by maximization of mutual information was used for matching between PET-rCBF and SPECT images. The highest correlation coefficient between $^{99m}Tc$-HMPAO and $^{99m}Tc$-ECD brain uptake and PET-rCBF was revealed at ${\alpha}$ 1.4 and 2.1, respectively. We concluded that the ${\alpha}$ values of Lassen's linearization algorithm for $^{99m}Tc$-HMPAO and $^{99m}Tc$-ECD brain SPECT images were 1.4 and 2.1, respectively to indicate cerebral blood flow with comparison of PET-rCBF.

  • PDF

Retention Characteristics of Tc-99m-Pullulan-Derivatives in CT26 Tumor of Mice (마우스 CT26 종양에서 Tc-99m 표지 플루란유도체의 저류 특성)

  • Heo, Young-Jun;Song, Ho-Chun;Bom, Hee-Seung;Na, Kun;Kim, Seong-Min
    • The Korean Journal of Nuclear Medicine
    • /
    • v.37 no.6
    • /
    • pp.393-401
    • /
    • 2003
  • Objective: Pullulan derivatives (PD) can be used to make self-assembled hydrogel nanoparticles which are responsive to ionic strength. The aim of this study is to evaluate the potential of PD as a retaining carrier of radioisotope inside tumors. Materials and Methods: Four types of PD were evaluated which included pullulan acetate (PA), succinylated PA (SPA), PA-DTPA and SPA-DTPA conjugates. They were radiolabeled with Tc-99m. Labelling efficiencies were determined at 30 min, 1, 2, 4 and 12 hours after radiolabeling. CT-25 colon cancer cells were subcutaneously injected into Balb/c mice. After 2 weeks of subcutaneous injection, Tc-99m-labelled PD (Tc-99m-PD) were injected into the tumors. Whole body images of mice were obtained at 30 min, 1, 2, and 12 hr after intratumoral injection. All twenty mice were grouped into four groups by largest diameter; control A (largest diameter = 5 mm, n = 5), control B (largest diameter = 10 mm, n = 5), pullulan A (largest diameter = 5 mm, n = 5), pllulan B (largest diameter = 10 mm, n = 5). Dynamic images were obtained for 1 hour after intratumoral injection. Static images were obtained at 1 hr, 2 hr, 3 hr and 4 hr after intratumoral injection with Tc-99m pertechnetate and Tc-99m-PA. Target-to-background ratios and retention rates were calculated. Results: Labeling efficiencies of PA, SPA, PA-DTPA and SPA-DTPA were $94.5{\pm}5.9%,\;97.8{\pm}3.5%\;94.2{\pm}3.8%,\;and\;92.5{\pm}6.2%$, respectively (p>0.05). Percent retention rates (%RR) of PA and PA-DTPA were significantly higher than those of control, however, those of SP-DTPA and SPA became similar to control at 4 and 12 hr, respectively. %RR of pullulan A and pullulan B at 1, 4 and 8 hr is significantly higher than that of control (p < 0.05). However, %RR between pullulan A and pullulan B were similar. Conclusion: The lonic strength dependent PD-nanoparticles are retained in the tumor. No difference of %RR according to tumor size was noted. Therapeutic application of PD labelled with beta- or alpha- emitting radionuclides can be expected.

Solubilities and Major Species of Selenium and Technetium in the KURT Groundwater Conditions (KURT 지하수 조건에서 셀레늄과 테크네튬의 용해도 및 주요 화학종)

  • Kim, Seung-Soo;Min, Je-Ho;Baik, Min-Hoon;Kim, Gye-Nam
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.10 no.1
    • /
    • pp.13-19
    • /
    • 2012
  • The long-lived fission products $^{79}Se$ and $^{99}Tc$ have been considered as the major concern nuclides for the disposal of radioactive waste because of their high solubilities and the existence of anionic species in natural water. In this study, the solubilities of $FeSe_2(s)$ and $TcO_2(s)$, known as respective Solubility Limiting Solid Phase (SLSP) of selenium and technetium, were measured in the KURT (KAERI Underground Research Tunnel) groundwater under various pH and redox conditions. And their solubilities and major species were also calculated using geochemical codes under conditions similar to experimental solutions. Experimental results and calculation for $FeSe_2$ show that the solubility of selenium was found to be below $1{\times}10^{-6}mol/L$ under the condition of pH 8~9.5 and Eh=-0.3~-0.4 V while the dominant species was identified as $HSe^-$. For $TcO_2$, the solubility of technetium was found to be $5{\times}10^{-8}{\sim}1{\times}10^{-9}mol/L$ in the solutions of pH 6~9.5 and Eh<-0.1 V, while the dominant species was $TcO(OH)_2$. However, when the Eh of the solution is -0.35 V, $TcO(OH)_3^-$ and $TcO_4^-$ are calculated as the dominant species at pH 10.5~12 and pH>12, respectively.

Usefulness of the transcutaneous bilirubinometer during phototherapy in neonatal jaundice (신생아 황달에서 광선치료 동안에 경피적 빌리루빈 측정기의 유용성)

  • Lee, Yung Kwun;Kim, Kyung Ah;Ko, Sun Young;Lee, Yeon Kyung;Shin, Son Moon
    • Clinical and Experimental Pediatrics
    • /
    • v.49 no.12
    • /
    • pp.1296-1300
    • /
    • 2006
  • Purpose : We studied the usefulness of transcutaneous bilirubinometers in follow-up of bilirubin levels during phototherapy in neonatal jaundice patients. Methods : Transcutaneous bilirubin (TcB) was measured twice per day on 90 neonatal jaundice patients without risk factors of jaundice by transcutaneous bilirubinometer JM-103(Minolta/Hill-Rom Air-shields, Japan). TcB was measured simultaneously on the patched-forehead (TcB-PF), patchedchest(TcB-PC), unpatched-forehead (TcB-UF) and unpatched-chest (TcB-UC) of infants with neonatal jaundice. Plasma bilirubin (PB) was measured by American Optical bilirubinometer (American Optical Co, Buffalo, USA) within 30 minutes after transcutaneous bilirubinometer measurement. Each TcB was compared with PB. Results : In the study group, the mean gestational age was $38.6{\pm}1.3wk$, the mean birthweight was $3,207.0{\pm}472.1g$, the mean age at start of phototherapy was $4.9{\pm}0.9days$ and the mean duration of phototherapy was $1.3{\pm}0.6days$. The correlation between TcB and PB level was observed. The correlation between TcB of the patched part (TcB-PF, TcB-PC) and PB was more significant than that of the unpatched part (TcB-UF, TcB-UC) and PB. The most significant correlation was between PB and TcB-PC. Conclusion : TcB was useful in the follow-up of jaundice during phototherapy as well the screening of jaundice in neonatal jaundice patients. TcB of patched-chest area was the most reliable site in transcutaneous bilirubinometer examination in neonatal jaundice patients.

A Study on $^{99m}Tc$-pertechnetate thyroid uptake in various thyroid diseases (각종(各種) 갑상선질환(甲狀腺疾患)의 $^{99m}Tc$-pertechnetate 갑상선섭취(甲狀腺攝取)에 관(關)한 연구(硏究))

  • Choi, Sung-Jae;Min, Hae-Sook;Koh, Chang-Soon;Lee, Mun-Ho
    • The Korean Journal of Nuclear Medicine
    • /
    • v.8 no.1_2
    • /
    • pp.29-37
    • /
    • 1974
  • The $^{99m}Tc$-pertechnetate thyroid uptake rates(20 min) were measured in 24 healthy normal subjects, 140 patients with nontoxic goiter and 98 patients with thyrotoxicosis who were treated at the Thyroid Clinic, Seoul National University Hospital, from August 1972 to August 1973. Diagnostic reliabilities and correlations between $^{99m}TcO_4$-thyroid uptake rate (20 min) and other thyroid function tests were evaluated. The observed results were as follows 1. The $^{99m}TcO_4$-thyroid uptake rates (20 min) in normal subjects, euthyroid group and hyperthyroid group were $4.1{\pm}0.9%,\;5.2{\pm}1.8%\;and\;29.7{\pm}10.6%$. There was a significant difference between the mean of the euthyroid group and the mean of the hyperthyroid group and so differentiation between them can be easy. 2. In the diagnosis of hyperthyroidism, the reliabilities of $^{99m}TcO_4$- thyroid uptake rate(20 min), $^{131}I$ thyroid uptake rate(24hrs), serum $T_3$ resin uptake rate, serum $T_4\;and\;T_7\;were\;87.9{\sim}97.9%,\;81.2{\sim}94.4%,\;87.9{\sim}97.9%,\;90.5{\sim}99.3%\;and\;93.7{\sim}100%$. $^{99m}TcO_4$-thyroid uptake rate(20 min) is more accurate than $^{131}I$ thyroid uptake rate (24 hrs) in the diagnosis of hyperthyroidism. 3. $^{99m}TcO_4$-thyroid uptake rate (20 min) was well correlated with $^{131}I$ thyroid uptake rate (24 hrs), serum $T_3$ resin uptake rate, serum $T_4\;and\;T_7$. Points in favor of $^{99m}Tc$ are that it gives a small radiation dose to the thyroid, that tests can be repeated at the short interval, the study can be completed at a single patient visit and it is particularly well suited for the assessment of thyroid function in patients being treated with an antithyroid drug.

  • PDF

Discharge Characteristics of Indicator Microorganisms from Agricultural-Forestry Watersheds (농지-임야에서 발생하는 지표미생물 유출 특성)

  • Kim, Geonha
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.1B
    • /
    • pp.153-160
    • /
    • 2008
  • To estimate microbial contaminant loading discharged from diffuse sources, rainfall runoff of six rainfall events were monitored at three study watersheds of forestry and agricultural land use. Monitored indicator microorganism constituents were total coliform (TC), fecal coliform (FC), Escherichia coli (EC), and fecal streptococcus (FS). Soil loss during elevated flow rate caused higher suspended solid concentrations. Indicator microorganism concentrations were closely related with flow rate. TC event mean concentration (EMC) from unpolluted forestry was $5.3{\times}10^3CFU/100ml$, FC EMC was $1.4{\times}10^3CFU/100ml$, EC EMC was $1.1{\times}10^3CFU/100ml$, and FS EMC was $2.9{\times}10^2CFU/100ml$. From a watershed with agricultural-forestry land use, TC EMC was $1.7{\times}10^5CFU/100ml$, FC EMC was $8.5{\times}10^4CFU/100ml$, EC EMC was $8.9{\times}10^4CFU/100ml$, and FS EMC was $3.4{\times}10^4CFU/100ml$. Mixed land use of agricultural-forestry with bigger area, TC EMC was $1.9{\times}10^5CFU/100ml$, FC EMC was $9.6{\times}10^4CFU/100ml$, EC EMC was $7.0{\times}10^4CFU/100ml$, and FS EMC was $5.1{\times}10^4CFU/100ml$.