• Title/Summary/Keyword: TC/TM Data

Search Result 18, Processing Time 0.036 seconds

Design of TM/TC data protocol of Military Unmanned Aerial Vehicles (군용 무인기의 TM/TC 데이터 프로토콜 설계)

  • Hong, Su-woon;Kim, Young-kil
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.22 no.3
    • /
    • pp.506-512
    • /
    • 2018
  • Unmanned aerial vehicles(UAVs) operating in the military for various purposes are designed to transmit information collected according to the purpose to GCS(Ground Control System), and to transmit/receive the vehicle's operational control and status information using wireless communication(or datalink). Currently, the military UAV systems in operation in Korea use unique communication methods, protocols, and message structures for each system. Among these, the Division UAV is designed to transmit fixed size TM/TC data repeatedly and the Corps UAV is designed to transmit aperiodic TM/TC data to the variable length of the message-based. In this paper, we analyze the TM/TC data protocol of existing military UAV systems and present data protocol design method which is considered to be more efficient in wireless communication environment applied to equipment under development. And we will discuss issues to be considered for standardization of technology for ensuring interoperability with many UAVs or newly introduced UAV systems.

Analysis of TM/TC data protocol of Military Unmanned Aerial Vehicles (군용 무인항공기의 TM/TC 데이터 프로토콜 분석)

  • Hong, Su-woon;Kim, Young-kil
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2017.05a
    • /
    • pp.391-393
    • /
    • 2017
  • Unmanned aerial vehicles(UAVs) operating in the military for various purposes are designed to transmit information collected according to the purpose to GCS(Ground Control System), and to transmit/receive the vehicle's operational control and status information using wireless communication(or datalink). Currently, the military UAV systems in operation in Korea use unique communication methods, protocols, and message structures for each system. In this paper, we analyze the TM/TC data protocol of two types of military UAV systems currently under development and propose a more efficient TM/TC message design scheme in wireless communication(or datalink) environment. And we will discuss issues to be considered for standardization of technology for ensuring interoperability with many UAVs or newly introduced UAV systems.

  • PDF

Water Management Program for TM/TC (물관리자동화시스템(TM/TC)을 위한 물관리프로그램 개발)

  • go, Gwang Don;Lim, Chang Young;Kwak, Yeong Cheol
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2004.05b
    • /
    • pp.790-793
    • /
    • 2004
  • TM/TC system is composed of control center, reservoirs, pumping stations and twelve canal systems. For this system we developed water management program which includes flood forecast program, drought reduction program, irrigation scheduling program and database program. With these program we expect that operators improve the irrigation efficiencies of the irrigation systems due to the timely irrigation on a right place, in a proper quantity and refute tile cost of maintenance and reduce flood and drought damages. In agricultural engineering respect, the databases including water level, rainfall, the amount of flowing can be useful to the researcher who make a study of hydrology and hydraulics in . rural area. Water management program records all of the TM/TC data to MDB format file per 10 minutes.

  • PDF

TIMBER AGE ESTIMATION OF COMMERCIAL TIMBERLAND IN TENNESSEE, USA USING REMOTELY SENSED DATA

  • Lee, Jung-Bin;Kim, Sung-Hoon;Jayakumar, S.;Heo, Joon
    • Proceedings of the KSRS Conference
    • /
    • 2007.10a
    • /
    • pp.449-451
    • /
    • 2007
  • In the commercially managed timber lands, the information such as height, age, stand density, canopy closure and leaf area index need to be collected periodically. Stand volume is the most fundamental information in the valuation of timber, however, stand age information is the primary element of forest inventory and these two are highly correlated. Conventional method of collecting stand age information by field surveys such as ring count method is accurate; however, it is expensive, labor-intensive and time consuming. In the present study it was aimed to collect stand age information using modem techniques in a commercially managed timberland situated in Tennessee, USA. The Landsat Thematic Mapper (TM), Enhanced Thematic Mapper (ETM+) of three different periods, Shuttle Radar Topography Mission (SRTM), National elevation dataset (NED) and field inventory data were used. Normalized difference vegetation index (NDVI) and Tasselled Cap (TC) transformation techniques were applied on the TM and ETM+ data. The regression analysis was carried out to identify the correlation between stand age and NDVI, TC. In the present study about 2,469 datasets were analyzed. The $R^{2}$ value for stand age estimation was 0.713. The NDVI, TC2 and TC3 were found to produce accurate timber age information.

  • PDF

A Practical Study of Unified Management System for Irrigation and Drainage Facilities (수리시설물 통합관리시스템 실용화 연구)

  • 김선주;박성삼
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.40 no.3
    • /
    • pp.42-53
    • /
    • 1998
  • About 50 percent of irrigation and drainage facilities in our country are deteriorated as they were constructed over 40 years ago. Worsening the problems in function might be caused by these facilities' constant exposure to the elements. With these reason, efficient maintenance and management of irrigation and drainage facili- ties are required. A computerized system is tailored on the basis of the each characteristics'data of irrigation and drainage facilities. The unified management system to be introduced in this study is a package program consisting of three subprograms. Facility Management(FM) system, the first component, is a relational database system for image processing and registering the characteristics of irrigation and drainage facilities. The objective of this program is to manage the ledger of each facilities and to scan the characteristics of facilities. Telemeter(TM) system, the second component, monitors and processes the data from the sensors statistically. This system is preprogramed for the complete design of TC/TM system. Hydrological Data Management(HDM) system, the third component, executes the hydrological analysis using meteorological data. The unified management system can provide the latest information, such as image data, lists and items of facilities, and items of reforming and rebuilding etc., of the facilities to the manager. At the same time, this system can manage hydrological and meteorological data in realtime.

  • PDF

Water Management Program for Hasa District (하사지구 물관리 프로그램 개발)

  • Go, Gwang-Don;Kwun, Soon-Kuk;Lim, Chang-Young;Kwak, Yeong-Cheol
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2002.10a
    • /
    • pp.17-20
    • /
    • 2002
  • Hasa TM/TC system is composed of one control center, two reservoirs, six pumping stations and twelve canal systems. For this system we developed water management program which includes flood forecast program, drought reduction program, irrigation scheduling program and database program. With these program we expect that operators can improve the irrigation efficiencies of the irrigation systems due to the timely irrigation on a right place, in a proper quantity and reduce the cost of maintenance and reduce flood and drought damages of the Hasa district. In agricultural engineering respect, the databases including water level, rainfall, the amount of flowing can be useful to the researcher who make a study of hydrology and hydraulics in rural area. Water management program records all of the TM/TC data to MOB format file per 10 minutes.

  • PDF

A Study of Quality Control of Nuclear Medicine Counting System and Gamma Camera (핵의학 계측기기 및 감마카메라의 정도관리 연구)

  • 손혜경;김희중;정해조;정하규;이종두;유형식
    • Progress in Medical Physics
    • /
    • v.12 no.2
    • /
    • pp.103-112
    • /
    • 2001
  • Purpose: The purpose of this study was to investigate the current status of performing nuclear medicine quality control in korea and to test selected protocols of quality control of nuclear medicine counting system and gamma camera. Materials and Methods: Fifty three hospitals were included to investigate the current status of nuclear medicine quality control in korea. The precision of dose calibrator and thyroid uptake system was measured with Tc-99m 35.52 MBq for 2 minuets and Tc-99m 5.14 MBq for 10 sec every one minute, respectively. The sensitivity of CeraSPECT$^{TM}$ with low energy high resolution parallel hole collimator was measured using two cylindrical phantoms with 15 cm in diameter and 12 cm and 30 cm in heights containing Tc-99m. The correction factor for sensitivity of CeraSPECT$^{TM}$ was calculated using phantom data. The system planar sensitivity, uniformity, count rate and spatial resolution were measured for Varicam gamma camera with low energy high resolution parallel hole collimator using 140 keV centered 20% energy window, 256$\times$256 or 512$\times$512 matrix sizes. Results: The quality control of dose calibrator and well counter were showed poor performance status. On the other hand, The quality control of gamma camera and other systems were showed relatively good performance status. The results of precision of dose calibrator and thyroid uptake system was $\pm$1.4%(<$\pm$5%) and chi^2=29.7(>16.92), respectively. It showed that the sensitivity of CeraSPECT$^{TM}$ was higher in center slices compared with the edge slices. After correction of nonuniform sensitivities for patient data, it showed better results compare with prior to correction. System planar sensitivity of Varicam gamma camera was 4.39 CPM/MBq. The observed count rate at 20% loss was 102,407 counts/sec (head 1), 113,427 counts/sec (head 2), when input count rate was 81,926 counts/sec (head 1), 90,741 counts/sec (head 2). The spatial resolution without scatter medium were 8.16 mm of FWHM and 14.85 mm of FWTM. The spatial resolution with scatter medium were 8.87 mm of FWHM and 18.87 mm of FWTM. Conclusion: It is necessary to understand the importance of quality control and to perform quality control of nuclear medicine devices.vices.

  • PDF

COMS System Bus Design and Analysis using MIL-STD-1553B (MIL-STD-1553B 버스를 이용한 통신해양기상위성의 시스템 버스 설계 및 분석)

  • Cho, Young-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.7
    • /
    • pp.1285-1289
    • /
    • 2008
  • In this paper, we design COMS system bus that the 1553 Data Bus is able to link all the units of the satellite managed by the SCU using one Prime Data Bus and on Redundant Data Bus. Also we analyze MIL-STD-1553B bus load and relevant exchange memory budgets in system bus of the COMS satellite. This data is used in the satellite mission and software design by system engineer.

Design, Implementation, and Tests of KOMPSAT-2 S/W simulator

  • Lee, Sang-Uk;Cho, Sung-Ki;Kim, Jae-Hoon
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.706-710
    • /
    • 2003
  • In this paper, we will present brief design feature, implementations, and tests for verification of KOMPSAT-2 simulator, which is a subsystem of KOMPSAT-2 MCE. SIM is implemented on PC server to minimize costs and troubles on embedding onboard flight software into SIM, OOA/OOD methodology is employed to maximized S/W reusability, and XML is used for S/C characteristics, TC, TM and Simulation data instead of commercial DB. Consequently, we can reduce costs for the system, efforts embedding flight software, and maximize software reusability. SIM subsystem test was performed successfully.

  • PDF

Effect of satellite link noise for satellite range measurement using tone method (Tone 방식을 사용한 위성 거리 측정에 대한 위성 링크 잡음의 영향)

  • Kim Young Wan
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.42 no.2 s.332
    • /
    • pp.9-16
    • /
    • 2005
  • The performance of satellite range measurement using tone method was analyzed in the presence of satellite link AWGN. The phase errors in range measurement are generated by AWGN of satellite up- and down-link and the degradations of satellite range measurement are dependent on the transmission mode and loop bandwidth of satellite measurement system. The analyzed effects for satellite measurement in presence of satellite link noise were also analyzed with the measured satellite range data via satellite range measurement system operating in satellite link AWGN. In RAU mode, the satellite range differences of 14.4 to 40.6 m were occurred according to the loop bandwidth of satellite range measurement system and the degradation of 0.3 dB compared with theoretical value was generated under condition of the signal-to-noise ratio of 43 dB. In RAU and TM mode, the performances of range measurement were approximately agreed to the that of RAU mode. In order to get the equal performance characteristics with RAU mode, the signal-to-noise ratio of satellite link for RAU and TM mode should be increased by signal power of 2.3 dB, which is a power loss due to transmission of telemetry signal.