• 제목/요약/키워드: TAC temperature

검색결과 24건 처리시간 0.026초

청과물 저온저장고의 설계에 관한 연구 (1) -자연환기를 이용한 제주산밀감저장고의 설계- (On the Design of Cold Storage for Fruits and Vegetables (1) -Design of Natural Ventilating Type Store for Citrus Furits in Jejudo-)

  • 허종화;김효경
    • 대한설비공학회지:설비저널
    • /
    • 제5권4호
    • /
    • pp.272-280
    • /
    • 1976
  • A natural ventilating type store was designed for the economic and effective storage of citrus fruits in Jejudo. The material used for the wall is scoria, widely distributed in Jejudo and known for high strength and insulation. Design condition was chosen for the period till March of a year and the dry bulb temperature was taken from TAC $5\%$ base. The temperature of the store can be maintained below the limiting temperature of $8^{\circ}C$ for the time length of $7\frac{1}{2}$ hours under the condition of the atmospheric temp, $15.3^{\circ}C$ and the solar insolation. The limiting temperature can he recovered to the initial temperature $(7^{\circ}C)$ by the natural ventilation for 8 hours in the night.

  • PDF

A Study on Weather Data for Air Conditioning Equipment Design Report I - Weather Data in Busan from 1970 through 2003

  • Kim Jong-Ryeol;Kum Jong-Soo;Choi Kwang-Hwan
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제14권1호
    • /
    • pp.1-6
    • /
    • 2006
  • For the purpose of processing weather data for air conditioning equipment de sign in Busan area Korea, this study collected weather observations made by Busan weather Administration from 1970 to 2003, and then established external conditions for heating and air-conditioning design. For changes of temperature in external conditions for design, the highest temperature had little changed, whereas the lowest had been on the rise as the years went by through the 1970s, 1980s, 1990s, and 2000s, but insolation has a little lessened. Absolute humidity does not show a significant change but an incessant rise.

음향구동 냉동 온도차의 주파수 및 위치 의존 특성 (Frequency and Position Dependences of Acoustically Driven Refrigerating Temperature Differences)

  • 김용태;서상준;정성수;조문재
    • 한국음향학회지
    • /
    • 제18권4호
    • /
    • pp.3-10
    • /
    • 1999
  • '음향열 기울기 온도 측정장치'[1]를 길이 68cm인 직관 내에서 위치를 변화시키면서 음파의 열수송 온도차를 조사하였다. 확성기 구동 전력을 50W로 고정하고 주파수를 150Hz에서 300Hz까지 10Hz 간격으로 변화시키면서 실험하여 이론값과 비교하였다. 수치 시뮬레이션을 통해 Q-값에 따른 열음향 냉동 온도차의 주파수-위치 분포를 살펴보았다. 이 분포를 이용하여 최적 구동 주파수와 열음향 교환기의 최적 위치를 결정할 수 있다.

  • PDF

기상 데이터 산정 기간에 따른 국내의 설계용 외기온도 분석 (Analysis of South Korea Outdoor Design Temperature with respect to Assigned Period of the Weather Data)

  • 남아영;김영일;정광섭
    • 한국지열·수열에너지학회논문집
    • /
    • 제13권2호
    • /
    • pp.1-8
    • /
    • 2017
  • Outdoor design temperature is important for selecting proper capacity of heating and cooling systems of a building to implement indoor thermal comfort and save energy consumption. The purpose of this study is to investigate the change of South Korea outdoor design temperature according to the assigned period. When outdoor design temperature of 8 locations calculated with the latest weather data during 2008~2015 years using ASHRAE Bin method are compared to the standard temperature of Ministry of Land, Infrastructure and Transport which is widely used for designing South Korea air-conditioning system at present, the maximum temperature difference becomes $0.97^{\circ}C$ for cooling, and $1.94^{\circ}C$ for heating. Due to wide outdoor temperature variation, update of outdoor design temperature based on recent weather data is recommended.

플로팅 해상호텔의 부하계산에 관한 연구 (A Study on Load Estimation of Floating Hotel)

  • 도근영;송화철;원종민;김구상;김주연
    • 한국항해항만학회지
    • /
    • 제35권5호
    • /
    • pp.401-406
    • /
    • 2011
  • 경제적 여유와 함께 사람들의 요구가 다양화 되면서 해양 레저에 대한 관심이 증가하고 있다. 삼면이 바다인 우리나라는 바다를 이용한 해양 레저의 잠재력이 매우 높기 때문에 해양 리조트 개발이 증가할 것으로 예상된다. 그러나 이미 포화상태에 이르렀으며 또한 환경문제를 내포하고 있는 매립에 의한 개발은 상당한 어려움이 따를 것으로 예상된다. 이에 대한 대안으로 플로팅 건축에 의한 개발이 확대될 것으로 기대되지만 플로팅에 의한 해상호텔에 대한 연구는 아직 초보적인 단계에 있으며 이용객의 쾌적성에 직접적인 영향을 미치는 공조 설비 용량을 선정하기 위한 부하계산에 대한 연구는 전무하다고 할 수 있다. 본 연구에서는 육상의 일반적인 호텔과 선박의 공조부하 계산법을 비교 분석함으로써 해상호텔의 공조부하계산방법에 대해 검토한다.

온실의 냉난방시스템 설계용 외부기상조건 분석 (Analysis of the Outdoor Design Conditions for Greenhouse Heating and Cooling Systems in Korea)

  • 남상운;신현호
    • 생물환경조절학회지
    • /
    • 제25권4호
    • /
    • pp.308-319
    • /
    • 2016
  • 온실의 냉난방시스템 설계 기준에 적용하기 위한 외부기상조건을 설정하기 위하여 난방 설계용 외기온, 난방 degree-hour, 냉방 설계용 건구온도, 습구온도, 일사량을 분석하여 제시하였다. 우리나라 전 지역을 대상으로 현재 기상청에서 제공하는 기후평년값 기준인 1981~2010년까지 30년간의 매 시각 기상자료를 분석에 사용하였다. 표준기상데이터의 이용이 제한적이기 때문에 30년간의 전체 기상자료를 이용하여 설계용 기상조건을 구하고, 전체 자료기간의 평균값을 설계기준으로 제시하였다. TAC 방식으로 위험률 1, 2.5, 5%에 대한 설계용 기상자료를 분석하고, 설계기준에서 추천하고 있는 난방용은 위험률 1%, 냉방용은 위험률 2.5%의 기상조건 분포도를 제시하였다. 지역별, 위험률별 및 설정온도별로 최대난방부하, 기간난방부하 및 최대냉방부하의 변화를 고찰하였다. 제시된 각종 설계용 기상조건은 온실의 냉난방시스템 설계에 직접 이용할 수 있을 뿐만 아니라 냉난방 설비 보강이나 에너지 절감대책의 수립에 활용이 가능할 것으로 판단된다. 한편 기후변화로 인하여 최근 여름철 폭염이나 겨울철 이상고온 현상이 자주 발생하고 있으므로 주기적인 설계용 기상자료의 분석이 필요하고, 최소한 10년 주기로 설계기준을 개정할 필요가 있는 것으로 생각된다. 본 연구에서는 현재 기후평년값 기준인 1981~2010년까지의 기상자료를 분석하였으나 이 기준이 1991~2020년으로 바뀌는 2021년에는 즉시 이 기간의 기상자료를 분석하여 새로운 설계기준으로 제공해야 할 것으로 판단된다.

Isolation and Characterization of Transcriptional Elements from Corynebacterium glutamicum

  • Park, Soo-Dong;Lee, Sang-Nam;Park, Ik-Hyun;Choi, Jong-Su;Jeong, Wol-Kyu;Kim, Youn-Hee;Lee, Heung-Shick
    • Journal of Microbiology and Biotechnology
    • /
    • 제14권4호
    • /
    • pp.789-795
    • /
    • 2004
  • A promoter-probe shuttle vector pSK1Cat was constructed for the isolation of transcriptional signal sequences from Corynebacterium glutamicum. Besides conferring resistance to kanamycin in Escherichia coli and C. glutamicum, the vector carried a promoterless cat gene to confer resistance to chloramphenicol upon insertion of the appropriate transcriptional signals in the multiple cloning site. By utilizing the vector, a series of transcriptionally active fragments were isolated from the genome of C. glutamicum. The clones, ranging from 200 bp to 1 kb in size, were grouped into 3 classes of strong, medium, and weak, based on the chloramphenicol acetyltransferase (CAT) activity and sensitivity to the chloramphenicol of the clone-carrying C. glutamicum cells. C. glutamicum cells carrying the $P_{19}$ clone, a representative in the strong class, were able to grow on minimal agar plates containing over $40 mg/mell$ chloramphenicol, and showed CAT activity of 10 m㏖/mgㆍmin, performing slightly better than the cells carrying $P_{tac}$ , a strong E. coli promoter. Subcloning analysis of the $P_{19}$ clone identified a 180 bp intergenic fragment ($P_{180}$), which was located upstream of a gene encoding a hypothetical membrane protein. The expression conferred by $P_{180}$ was not affected by either the kinds of carbon sources or changes in temperature. These properties make the $P_{180}$ clone useful for the deregulated expression of biosynthetic genes in C. glutamicum during amino acid fermentation.

해수열원 스크류 히트펌프의 연간 난방운전 성능 모사 (A Simulation Study on the Annual Heating Performance of the Seawater-Source Screw Heat Pump)

  • 백영진;김민성;장기창;이영수;김현주
    • 한국태양에너지학회 논문집
    • /
    • 제32권3호
    • /
    • pp.88-95
    • /
    • 2012
  • In this study, in order to utilize the seawater as a heat source at Gangneung city near the East Sea in Korea, an annual heating performance of a screw heat pump was simulated. For a simulation, the maximum heating capacity of heat pump was assumed at 3.5 MW. An ambient temperature at Gangneung city was calculated from the TMY2 weather data, while the seawater temperature was calculated from the regression equation based on the measurement by the National Fisheries Research and Development Institute of Korea. The heating load was assumed linearly dependent on the ambient temperature, while the maximum heating load was assumed to appear when the ambient temperature is below $-2.4^{\circ}C$, which is the temperature of TAC 2.5% for heating at Gangneung city. A heat pump performance at full-load was calculated from the regression equation, which involves refrigerant's evaporating and condensing temperatures, based on a commercial screw compressor performance map. A heating supply temperature which determines refrigerant's condensing temperature was assumed linearly dependent on the heating load. A performance degradation due to the part-load operation of heat pump was also considered. Simulation results show that an annual heating coefficient of performance ($COP_H$) of a seawater-source screw heat pump is approximately 2.8 and that it is necessary to improve part-load performance to increase an annual performance of the heat pump.

해수열원 스크류 히트펌프의 연간 난방운전 성능 시뮬레이션 (A Simulation Study on the Annual Heating Performance of the Seawater-Source Screw Heat Pump)

  • 백영진;김민성;장기창;강병찬;라호상;김현주
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2012년도 춘계학술발표대회 논문집
    • /
    • pp.488-493
    • /
    • 2012
  • In this study, in order to utilize the seawater as a heat source at Gangneung city near the East Sea in Korea, an annual heating performance of a screw heat pump was simulated. For a simulation, the maximum heating capacity of heat pump was assumed at 3.5 MW. An ambient temperature at Gangneung city was calculated from the TMY2 weather data, while the seawater temperature was calculated from the regression equation based on the measurement by the National Fisheries Research and Development Institute of Korea. The heating load was assumed linearly dependent on the ambient temperature, while the maximum heating load was assumed to appear when the ambient temperature is below $-2.4^{\circ}C$, which is the temperature of TAC 2.5% for heating at Gangneung city. A heat pump performance at full-load was calculated from the regression equation, which involves refrigerant's evaporating and condensing temperatures, based on a commercial screw compressor performance map. A heating supply temperature which determines refrigerant's condensing temperature was assumed linearly dependent on the heating load. A performance degradation due to the part-load operation of heat pump was also considered. Simulation results show that an annual heating coefficient of performance ($COP_H$) of a seawater-source screw heat pump is approximately 2.8 and that it is necessary to improve part-load performance to increase an annual performance of the heat pump.

  • PDF

전자선 가교된 유리섬유 강화 나일론 12의 열적 거동 및 내마모 특성 (Thermal Behavior and Abrasion Properties of Glass Fiber Reinforced Nylon 12 Crosslinked by Electron Beam Irradiation)

  • 신범식;전준표;김현빈;강필현
    • 폴리머
    • /
    • 제35권1호
    • /
    • pp.30-34
    • /
    • 2011
  • 나일론 12의 열적 거동 및 내마모 특성을 확인하기 위해서 100~600 kGy로 조사선량을 달리 하여 전자선가교 반응을 진행하였다. 가교효과를 증대시키기 위해서 TAC, TAIC, TMPTMA의 가교제를 추가로 사용하였다. 나일론 12는 200 kGy 이상 전자선 가교가 진행되어야 높은 젤화율을 보이며, 조사선량이 증가할수록 결정성이 낮아져 $T_m$과 DSC 피크 면적이 서서히 감소되는 것을 확인하였고, 또한 열분해 온도가 상승하여 열적 안정성이 우수해짐을 확인하였다. 그리고 나일론 12의 내마모 특성도 향상되어 가교 전과 비교하였을 때 마모량, 마모계수가 감소하는 경향을 나타내었고, 마모 표변을 SEM 분석을 통해서 확인하였다. 나일론 12에 첨가된 가교제는 전자선 가교시 우수한 가교 효과를 나타내며, 열적, 내마모 특성을 향상시키는 것으로 확인되었다.