• Title/Summary/Keyword: T2-weighted image

Search Result 253, Processing Time 0.024 seconds

Biceps Femoris Tendon and Lateral Collateral Ligament: Analysis of Insertion Pattern Using MRI (대퇴이두건과 외측 측부인대: 자기공명영상을 이용한 부착형태 유형의 분석)

  • Shin, Yun Kyung;Ryu, Kyung Nam;Park, Ji Seon;Lee, Jung Eun;Jin, Wook;Park, So Young;Yoon, So Hee;Lee, Kyung Ryeol
    • Investigative Magnetic Resonance Imaging
    • /
    • v.18 no.3
    • /
    • pp.225-231
    • /
    • 2014
  • Purpose : The biceps femoris tendon (BFT) and lateral collateral ligament (LCL) in the knee were formerly known to form a conjoined tendon at the fibular attachment site. However, the BFT and LCL are attached into the fibular head in various patterns. We classified insertion patterns of the BFT and LCL using MR imaging, and analyzed whether the LCL attaches to the fibular head or not. Materials and Methods: A total of 494 consecutive knee MRIs of 470 patients taken between July 2012 and December 2012 were retrospectively reviewed. There were 224 males and 246 females, and patient age varied from 10 to 88 (mean, 48.6). The exclusion criteria were previous surgery and poor image quality. Using 3T fat-suppressed proton density-weighted axial images, the fibular insertion patterns of the BFT and LCL were classified into following types: type I (the LCL passes between the anterior arm and direct arm of the BFT's long head), type II (the LCL joins with anterior arm of the long head of the BFT), type III (the BFT and LCL join to form a conjoined tendon), type IV (the LCL passes laterally around the anterior margin of the BFT), and type V (the LCL passes posteriorly to the direct arm of the BFT's long head). Results: Among the 494 cases of the knee MRI, there were 433 (87.65%) type I cases, 21 (4.25%) type II cases, 2 (0.4%) type III cases, 16 (3.23%) type IV cases, and 22 (4.45%) type V cases. There were 26 cases (5.26%) in which the LCL and BFT were not attached into the fibular head. Conclusion: The fibular attachment pattern of the BFT and LCL shows diverse types in MR imaging. The LCL does not adhere to the head in some patients.

Impact of Deep-Learning Based Reconstruction on Single-Breath-Hold, Single-Shot Fast Spin-Echo in MR Enterography for Crohn's Disease (크론병에서 자기공명영상 장운동기록의 단일호흡 단발 고속 스핀 에코기법: 딥러닝 기반 재구성의 영향)

  • Eun Joo Park;Yedaun Lee;Joonsung Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.84 no.6
    • /
    • pp.1309-1323
    • /
    • 2023
  • Purpose To assess the quality of four images obtained using single-breath-hold (SBH), single-shot fast spin-echo (SSFSE) and multiple-breath-hold (MBH) SSFSE with and without deep-learning based reconstruction (DLR) in patients with Crohn's disease. Materials and Methods This study included 61 patients who underwent MR enterography (MRE) for Crohn's disease. The following images were compared: SBH-SSFSE with (SBH-DLR) and without (SBH-conventional reconstruction [CR]) DLR and MBH-SSFSE with (MBH-DLR) and without (MBH-CR) DLR. Two radiologists independently reviewed the overall image quality, artifacts, sharpness, and motion-related signal loss using a 5-point scale. Three inflammatory parameters were evaluated in the ileum, the terminal ileum, and the colon. Moreover, the presence of a spatial misalignment was evaluated. Signal-to-noise ratio (SNR) was calculated at two locations for each sequence. Results DLR significantly improved the image quality, artifacts, and sharpness of the SBH images. No significant differences in scores between MBH-CR and SBH-DLR were detected. SBH-DLR had the highest SNR (p < 0.001). The inter-reader agreement for inflammatory parameters was good to excellent (κ = 0.76-0.95) and the inter-sequence agreement was nearly perfect (κ = 0.92-0.94). Misalignment artifacts were observed more frequently in the MBH images than in the SBH images (p < 0.001). Conclusion SBH-DLR demonstrated equivalent quality and performance compared to MBH-CR. Furthermore, it can be acquired in less than half the time, without multiple BHs and reduce slice misalignments.

Recent updated diagnostic methods for esophageal motility disorders (식도의 운동장애에 관한 최신지견)

  • Yoon, Seok-Hwan
    • Journal of radiological science and technology
    • /
    • v.27 no.4
    • /
    • pp.11-16
    • /
    • 2004
  • Classification of esophageal motility disorders not yet finalized and is still ongoing as the new disorders are reported, and the existing classification is changed or removed. In terms of radiology, the primary peristalsis does not exist, and the lower end of the esophagus show the smooth, tapered, beak-like appearance. The esophageal motility disorder, which mostly occurs in the smooth muscle area, show the symptoms of reduction or loss (hypomotility) or abnormal increase (hypermotility) of peristalsis of the esophagus. It is important to understand the anatomy and physiology of the esophagus for the appropriate radiological method and diagnosis. Furthermore, the symptom of the patient and the manometry finding must be closely referred for the radiological diagnosis. The lower esophageal sphincter can be normally functioning and open completely as the food moves lower. Sperandio M et al. argues that the name diffuse esophageal spasm must be changed to distal esophageal spasm (DES) as most of the spasm occurs in the distal esophagus, composed of the smooth muscle. According to Ott et al., usefulness of barium method for diagnosing the esophageal motility disorder is Achalasia 95%, DES 71% and NEMD 46%, with the overall sensitivity of 56%. However, excluding the nutcracker esophagus or nonspecific disorder which cannot be diagnosed with the radiological methods, the sensitivity increases to 89%. Using videofluoroscopy and 5 time swallows, the average sensitivity was over 90%. In conclusion, the barium method is a simple primary testing method for esophageal motility test. Using not only the image but also the videofluoroscopy with good knowledge of the anatomy and physiology, it is believed that the method will yield the accurate diagnosis.

  • PDF